0 |
Millennium 2 Premium |
1 |
JB-MPHF Series |
2 |
2721 Hopewell PL NE., Calgary, AB. Canada, PH: 403-219-0688 FX: 403-219-0694 |
3 |
Net Safety Monitoring Inc |
4 |
.1f |
5 |
4.1f |
6 |
.2f |
7 |
3.2f |
8 |
Reset |
9 |
gas value |
10 |
digital value gas help |
11 |
gas value unit |
12 |
%LEL,ppb,ppm or %Vol |
13 |
ppb |
14 |
parts per billion |
15 |
%Vol |
16 |
Percent Volume |
17 |
Gas Dev fmly |
18 |
Gas Class |
19 |
Gas PDQ |
20 |
Gas LS |
21 |
Gas Fmly stat |
22 |
gas upper sensor limit |
23 |
upper sensor limit gas help |
24 |
gas lower sensor limit |
25 |
Always 0 %LEL or ppm |
26 |
gas minimum span |
27 |
ALways 1 %LEL or ppm |
28 |
gas_damping_value |
29 |
We don't have damping value |
30 |
gas sensor serial number |
31 |
This is controller serial number |
32 |
7d |
33 |
Pres Lower trim |
34 |
Pres Upper trim |
35 |
Pres Trim support |
36 |
Pres Min lower trim |
37 |
Pres Max lower trim |
38 |
Pres Min upper trim |
39 |
Pres Max upper trim |
40 |
Pres Min trim diff |
41 |
Ml2 Controller |
42 |
Ml2 Controller only with MiniIR or Solid State |
43 |
Snsr temp unit |
44 |
Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. |
45 |
Temp Class |
46 |
Temp PDQ |
47 |
|
48 |
Temp LS |
49 |
Temp Dev Stat |
50 |
Temp USL |
51 |
Temp LSL |
52 |
Temp min span |
53 |
Temp snsr s/n |
54 |
Secondary Variable - Temperature Compensation |
55 |
Date and time |
56 |
MVI Test |
57 |
Events Log |
58 |
Sensor trim points |
59 |
Flame Unit Information |
60 |
Temperature sensor |
61 |
Analog Output |
62 |
Start MVI |
63 |
Stop MVI |
64 |
This will stop MVI test |
65 |
Next Log |
66 |
Previous Log |
67 |
Most Recent |
68 |
This will let user see the most recent calibration event log |
69 |
GasValue |
70 |
Gas Tracking |
71 |
CurrentLoopValue |
72 |
Current Loop Tracking |
73 |
Current Loop Value |
74 |
Gas Chart |
75 |
Flame Unit Type |
76 |
This is the flame unit type: IR3S, UVS, UV/IRS |
77 |
IR3S-AD |
78 |
UVS-A |
79 |
UV/IRS-A |
80 |
IR3S-A |
81 |
HART JB ID |
82 |
This is the Device ID for HART JB, after change this number, host need re-connect to device |
83 |
Date |
84 |
This is the Real Time CLock Date |
85 |
Time (HHMM) |
86 |
This is the Real Time Clock Time, Hour:Min as HHMM ( 10:30 as 1030 ) |
87 |
Status |
88 |
This is the Status of Flame Unit |
89 |
Unit No Power |
90 |
Power Fault |
91 |
VI Test Fault |
92 |
Power Up |
93 |
Normal |
94 |
Background UV |
95 |
Background IR |
96 |
MVI Adequate |
97 |
MVI Good |
98 |
MVI Excellent |
99 |
Instantaneous Fire |
100 |
Fire Confirmed |
101 |
CLP Fix at 4mA |
102 |
CLP Fix Current |
103 |
Unit Fault |
104 |
CLP Input Overflow |
105 |
CLP/MODBUS Output |
106 |
This is the flame unit Output condition |
107 |
Good |
108 |
CLP and MODBUS Mismatch |
109 |
MODBUS Fault |
110 |
Current Loop Drift |
111 |
Both CLP and MODBUS Fault |
112 |
Current Loop Fault |
113 |
DipSwitch Setting |
114 |
Dipswitch Conflict |
115 |
Event Date |
116 |
This is the date when a event happened |
117 |
Event Time |
118 |
This is the time when a event happened |
119 |
Event Type |
120 |
This is the event type and result |
121 |
No More Event |
122 |
Auto / MVI Fault |
123 |
UV Source |
124 |
IR Source |
125 |
Fire |
126 |
Unknown Event |
127 |
Dipswitch Not Match |
128 |
Other Fault |
129 |
Current Overflow |
130 |
CLP/MODBUS Mismatch |
131 |
CLP/MODBUS Fault |
132 |
Serial Number |
133 |
This is the serial number for Flame Unit |
134 |
Part Number |
135 |
This is the flame Unit Part Number |
136 |
manufactured Date |
137 |
This is the date when Flame unit was built |
138 |
Unit version |
139 |
This is the version for Flame unit |
140 |
8u |
141 |
8.3f |
142 |
.3f |
143 |
Output Status |
144 |
Output Status Byte |
145 |
Uninitialized |
146 |
Normal - one sensor |
147 |
Normal - two sensors |
148 |
Normal - three sensors |
149 |
Shorted |
150 |
Shorted- shorted field wiring. |
151 |
Limited high |
152 |
Limited high- block can not respond to upward movement of value. |
153 |
Open |
154 |
Open- open field wiring. |
155 |
Limited low |
156 |
Limited low- block can not respond to upward movement of target. |
157 |
Initialization done |
158 |
Initialization done- block initialization is complete. |
159 |
Not selected |
160 |
Not selected- target value provided by block was not selected. |
161 |
No path |
162 |
No path- there is no path to the process. |
163 |
Fail |
164 |
Fail- hardware failure. |
165 |
Bad |
166 |
Bad- block is out of service or has bad input. |
167 |
Not from process |
168 |
Not from process- value is not directly affected by any process information. |
169 |
Local override |
170 |
Local override- block has LO mode. |
171 |
Not Cascade Mode |
172 |
Not RCas Mode |
173 |
Not ROut Mode |
174 |
No communication |
175 |
No communication- (NO_COM). |
176 |
uint16_var_blk_char |
177 |
uint32_var_blk_char |
178 |
uint8_var_blk_char |
179 |
int8_var_blk_char |
180 |
new itest redef1 label |