0 |
Model TA2 |
1 |
MAGNETROL |
2 |
Device ID |
3 |
Poll Address |
4 |
Error/Warnings |
5 |
Usr Params Reset |
6 |
User Parameters Reset - The application configuration information has been reset. Please reconfigure the instrument under Basic Set Up. |
7 |
Prb Params Reset |
8 |
Probe Parameters Reset - Re-enter the probe calibration data under Cal Factors using the probe password. |
9 |
Module Cal Req'd |
10 |
Module Calibration Required - The TA2 electronics require re-calibration by Magnetrol. The instrument will continue to operate at reduced accuracy. |
11 |
Total Data Lost |
12 |
Totalizer Data Lost - Data in the Totalizer has been lost. Reset the totalizer. |
13 |
No Probe Signals |
14 |
No Probe Signals - Check Probe condition under Diagnostics, Probe Status. Check probe wiring. |
15 |
Probe Hdwe Fault |
16 |
Probe Hardware Fault - Check Probe condition under Diagnostics, Probe Status. Check probe wiring. |
17 |
Initializing TA2 |
18 |
Initializing - The TA2 is going through initialization. Flow measurement will begin after completion of the initialization. |
19 |
Fixed Signl Mode |
20 |
Fixed Signal Mode Active - The TA2 is not providing a signal based upon PV. This will only occur if the local display is being utilized in diagnostic mode or if the TA2 is in Gas Calibrate Mode. |
21 |
PV is |
22 |
Adjust Loop Current |
23 |
Loop Test |
24 |
Velocity |
25 |
Units |
26 |
Loop |
27 |
Flow |
28 |
Mass |
29 |
Temperature |
30 |
Totalizer |
31 |
Mode |
32 |
Gas Temp |
33 |
Total |
34 |
Velocty |
35 |
Density |
36 |
Diameter |
37 |
Area |
38 |
Install Factor - |
39 |
A |
40 |
B |
41 |
C |
42 |
Cal Coeff - |
43 |
Gas Coeff - |
44 |
Ag |
45 |
Bg |
46 |
Cg |
47 |
Dg |
48 |
Eg |
49 |
Velocity - Mass velocity is corrected to STP conditions. |
50 |
SF/M |
51 |
Standard feet per minute. |
52 |
SF/S |
53 |
Standard feet per second. |
54 |
Nm/s |
55 |
Normal meters per second. |
56 |
Flow - Select the units of measurement for the mass volumetric flow rate. |
57 |
SCFM |
58 |
Standard cubic feet per minute. |
59 |
Nm3/h |
60 |
Normal cubic meters per hour. |
61 |
Nl/h |
62 |
Normal liters per hour. |
63 |
Mass - Select units of measurement. |
64 |
lbs/H |
65 |
lbs/M |
66 |
kg/h |
67 |
kg/m |
68 |
Temperature - Select units of measurement for temperature. |
69 |
F |
70 |
Totalized Flow |
71 |
Totalizer - Select units of measurements used by the Totalizer. |
72 |
SCF |
73 |
Standard cubic feet. |
74 |
Nm3 |
75 |
Normal cubic meters. |
76 |
Nl |
77 |
Normal liters. |
78 |
lbs |
79 |
kg |
80 |
Diameter - Select the desired units of measurement for measuring the inside diameter of a circular pipe or duct. |
81 |
inches |
82 |
feet |
83 |
mm |
84 |
meters |
85 |
Area - Select units of measurement used for the flow area of the pipe or duct. |
86 |
in2 |
87 |
Square inches. |
88 |
ft2 |
89 |
Square feet. |
90 |
m2 |
91 |
Square meters. |
92 |
mm2 |
93 |
Square milimeters. |
94 |
Density - Select units of measurement for density at STP or Normal conditions. |
95 |
lb/ft3 |
96 |
kg/m3 |
97 |
kg/l |
98 |
STP Pressure |
99 |
STP Pressure - Permit the user to modify STP conditions to application specific requirements. Select Standard Pressure of 1 atmosphere (14.7 psia) or 1 bar (14.5 psia). |
100 |
1 Atmosphere |
101 |
1 Bar |
102 |
Volume Flow |
103 |
.0f |
104 |
Mass Flow |
105 |
Gas Temperature |
106 |
.2f |
107 |
Total - Displays the total flow over the elapsed time since the totalizer was last re-set. |
108 |
Minimum Span |
109 |
Damping |
110 |
Damping - Adds additional time delay to the TA2. Enter value as a time constant from 0 to 15 seconds. |
111 |
4.1f |
112 |
Lower Xducer Limit |
113 |
Lower Xducer Limit - Probe calibration factor, flow rates less than this value are outside the original calibration range. |
114 |
Upper Xducer Limit |
115 |
Upper Xducer Limit - Probe calibration factor, flow rates exceeding this value are outside the original calibration range. |
116 |
Zero Flow Signal |
117 |
Zero Flow Signal - Probe calibration factor. |
118 |
mW |
119 |
PV Loop |
120 |
5.2f |
121 |
Fault State |
122 |
Fault State - Select how the Analog output of the TA2 will respond if a fault in the instrument is detected. |
123 |
3.6mA |
124 |
22mA |
125 |
Hold |
126 |
4mA Set Point |
127 |
4mA Set Point - Enter the 4 mA point using the units of measurement previously selected. |
128 |
20mA Set Point |
129 |
20mA Set Point - Enter the 20 mA point using the units of measurement previously selected. |
130 |
% Output |
131 |
% |
132 |
Pipe ID |
133 |
Pipe Inside Diameter - The flow area must be entered. This is done by either entering the inside diameter of a pipe or the cross sectional area of the pipe or duct. |
134 |
.4f |
135 |
Flow Area |
136 |
Flow Area - The flow area must be entered. This is done by either entering the inside diameter of a pipe or the cross sectional area of the pipe or duct. |
137 |
Mode - Enable or Disable the totalizer operation. |
138 |
Disabled |
139 |
Enabled |
140 |
Elapsed Time |
141 |
Elapsed Time - Displays the elapsed time in hours since the totalizer was last re-set. |
142 |
.1f |
143 |
hours |
144 |
Low Flow Cutoff |
145 |
Low Flow Cutoff - velocity values less than the entered values will not be detected. This is useful if flow is detected when a no flow condition exists. |
146 |
Date/Time/Initials |
147 |
Date/Time/Initials - When and by whom calibration was performed. |
148 |
Magnetrol S/N |
149 |
Magnetrol S/N - Serial number of this unit. |
150 |
Signal |
151 |
Signal/PV - Displays the signal and the corresponding value of the PV. May be useful for diagnostics. |
152 |
Firmware Version |
153 |
Firmware Version - Provides the version of the Firmware and the date used by the TA2. |
154 |
4mA Trim Value |
155 |
4mA Trim Value - Factory parameter, displayed for diagnostic purposes only. |
156 |
4u |
157 |
20mA Trim Value |
158 |
20mA Trim Value - Factory parameter, displayed for diagnostic purposes only. |
159 |
Change Password |
160 |
User password required to change parameter settings from keypad. |
161 |
Delta T |
162 |
Delta T - Displays the set point temperature which the TA2 is controlling. Useful for diagnostics information. |
163 |
Temp Sensor |
164 |
Temp Sensor - Provides status of the Temperature sensor in the TA2. Will display either OK, Shorted, or Open. |
165 |
OK |
166 |
Shorted |
167 |
Open |
168 |
Unknown |
169 |
Flow Sensor |
170 |
Flow Sensor - Provides status of the Flow sensor in the TA2. Will display either OK, Shorted, or Open. |
171 |
Probe Heater |
172 |
Probe Heater - Provides status of the Probe Heater in the TA2. Will display either OK, Shorted, or Open. |
173 |
Heater Setting |
174 |
Heater Setting - Displays a value for the heater setting. Useful for diagnostics information. |
175 |
5u |
176 |
Install Factors - A, B, C; Install Factors are utilized in situations when the measured flow rate may need to be adjusted due to variations in flow profile or other installation factors. The Install Factors are the coefficients of the polynomial equation: Corrected Flow = A + Bv + Cv^2 where v is the velocity measured by the TA2. |
177 |
.6f |
178 |
A - Probe calibration factor. |
179 |
.5f |
180 |
B - Probe calibration factor. |
181 |
C - Probe calibration factor. |
182 |
STP Temperature |
183 |
STP Temperature - permit the user to modify STP conditions to application specific requirements. Enter temperature used for Standard Temperature. |
184 |
Ro |
185 |
Ro - Probe calibration factor. |
186 |
Fo |
187 |
Fo - Probe calibration factor. |
188 |
TCC-A |
189 |
TCC-A - Calibration factor. |
190 |
TCC-B |
191 |
TCC-B - Calibration factor. |
192 |
Density - Gas density at user STP conditions. |
193 |
Gas Calibrate Mode |
194 |
Gas Calibration Mode - Factory calibration mode. This mode should only be enabled after direction from Magnetrol. |
195 |
Ag - Calibration factor. |
196 |
Bg - Calibration factor. |
197 |
Cg - Calibration factor. |
198 |
Dg - Calibration factor. |
199 |
Eg - Calibration factor. |
200 |
Coeff Ratio |
201 |
Coeff Ratio - Factory calibration parameter. |
202 |
Set Point |
203 |
Set Point - Factory calibration parameter. |
204 |
Slope |
205 |
Slope - Factory calibration parameter. |
206 |
Power Predictor |
207 |
Power Predictor - Factory calibration parameter. |
208 |
Exception Code |
209 |
Exception Code - Factory parameter, displayed for diagnostic purposes only. |
210 |
3u |
211 |
Enter Password |
212 |
Password is required to change calibration factors, refer to calibration certificate. |
213 |
Main Menu |
214 |
Device Setup |
215 |
Basic Setup |
216 |
System Units |
217 |
Variable Selection |
218 |
Advanced Setup |
219 |
Install Factors |
220 |
STP Conditions |
221 |
Diagnostics |
222 |
Signal/PV |
223 |
Probe Status |
224 |
Cal Factors |
225 |
Probe Parameters |
226 |
Calibration Coeff |
227 |
Gas Parameters |
228 |
Gas Coefficients |
229 |
Control Parameters |
230 |
Device Description |
231 |
Review |
232 |
Reset Total |
233 |
Reset Total - Resets the totalizer and elapsed time to 0. |
234 |
FMU860 |
235 |
DT |
236 |
DVC |
237 |
FCX |
238 |
AS800 |
239 |
340T |
240 |
340C |
241 |
344 |
242 |
Siemens Micro K |
243 |
SITRANS L |
244 |
SIPAN PH |
245 |
SITRANS P |
246 |
75SMT |
247 |
UNIDELTA |
248 |
8320 |
249 |
SX5100 |
250 |
TSV175 |
251 |
DMU |
252 |
3780 |
253 |
BM70 |
254 |
8u |
255 |
Are You Sure? |
256 |
No;Yes |