0 |
Model 705 2.x |
1 |
MAGNETROL |
2 |
Loop Test |
3 |
Units |
4 |
6.1f |
5 |
Level of material in vessel |
6 |
5.1f |
7 |
% |
8 |
% Output |
9 |
Minimum Span |
10 |
Upper Range Limit |
11 |
Lower Range Limit |
12 |
4.1f |
13 |
Damping |
14 |
5.2f |
15 |
Loop |
16 |
Analog output loop current |
17 |
Alarms |
18 |
7xA_x |
19 |
7xA: Coaxial Probe (dielectric range >= 1.7) |
20 |
7xB_x |
21 |
7xB: Rigid Twin Rod Probe (dielectric range >= 2.0) |
22 |
7xD_x |
23 |
7xD: High Temperature-High Pressure Coaxial Probe (dielectric range >= 2.0) |
24 |
7xP_x |
25 |
7xP: High Pressure Coaxial Probe (dielectric range >= 1.7) |
26 |
7xR_x |
27 |
7xR: Coaxial Probe for flooding applications (dielectric range >= 1.7) |
28 |
7xS_x |
29 |
7xS: High Temperature-High Pressure Coaxial Probe for steam |
30 |
7xU_J |
31 |
7xU_J: Coaxial Probe for cryogenic liquids (dielectric range >= 1.7) |
32 |
7x7_x |
33 |
7x7: Flexible Twin Rod Probe (dielectric range >= 2.0) |
34 |
Type 9 |
35 |
Type 10 |
36 |
Type 11 |
37 |
Type 12 |
38 |
Type 13 |
39 |
Type 14 |
40 |
Type 15 |
41 |
Type of probe connected to transmitter |
42 |
Probe Type |
43 |
NPT |
44 |
US National tapered Pipe Thread |
45 |
BSP |
46 |
British Straight Pipe Thread |
47 |
Flange |
48 |
Welded ANSI or DIN Flange |
49 |
Mounting style of probe fitting |
50 |
Probe Mount |
51 |
Distance from face of process seal to end of probe |
52 |
Probe Length |
53 |
Probe Offset |
54 |
Desired level reading when liquid surface is at end of probe |
55 |
1.7 - 3 |
56 |
Dielectric constant of material lies between 1.7 and 3 |
57 |
3 - 10 |
58 |
Dielectric constant of material lies between 3 and 10 |
59 |
10 - 100 |
60 |
Dielectric constant of material lies between 10 and 100 |
61 |
1.4 - 1.7 |
62 |
Dielectric constant of material lies between 1.4 and 1.7 |
63 |
Dielectric |
64 |
Dielectric constant of material in vessel |
65 |
4mA Set Point |
66 |
20mA Set Point |
67 |
3.6mA |
68 |
22mA |
69 |
Hold |
70 |
Fault State |
71 |
Date/Time/Initials |
72 |
When and by whom calibration was performed |
73 |
3u |
74 |
Enter Password |
75 |
Password is required for adjusting Advanced Setup parameters Magnetrol S/N and Device id, and Diagnostic-Digital Settings parameters Window, Range, Gain, Conversion Factor and Scale Offset |
76 |
Magnetrol S/N |
77 |
Factory parameter, displayed for diagnostic purposes only |
78 |
8u |
79 |
New User Password |
80 |
User password required to change parameter settings from keypad |
81 |
02x |
82 |
h |
83 |
Error Codes |
84 |
Factory parameter, displayed for diagnostic purposes only. Refer to I & O Manual for interpretation |
85 |
4u |
86 |
Ticks |
87 |
Fiducial Ticks |
88 |
<Window> |
89 |
Range |
90 |
Gain |
91 |
Conversion Factor |
92 |
4i |
93 |
Scale Offset |
94 |
CFD |
95 |
Fixed |
96 |
Threshold |
97 |
Use 'CFD' except in situation with low dielectric (< 3) material over higher dielectric (> 10) material, e.g., oil over water, in which case use 'Fixed'. |
98 |
# of Ticks |
99 |
Damped time of flight. Factory parameter, displayed for diagnostic purposes only |
100 |
4mA Trim Value |
101 |
20mA Trim Value |
102 |
Firmware Version |
103 |
Main Menu |
104 |
Device Setup |
105 |
Basic Setup |
106 |
Advanced Setup |
107 |
Diagnostics |
108 |
Digital Settings |
109 |
Review |
110 |
Trim 4mA Point |
111 |
Trim 20mA Point |
112 |
|
113 |
% Out |
114 |
|
115 |
FMU860 |
116 |
DT |
117 |
DVC |
118 |
FCX |
119 |
AS800 |
120 |
340T |
121 |
340C |
122 |
344 |
123 |
Siemens Micro K |
124 |
SITRANS L |
125 |
SIPAN PH |
126 |
SITRANS P |
127 |
75SMT |
128 |
UNIDELTA |
129 |
8320 |
130 |
SX5100 |
131 |
TSV175 |
132 |
DMU |
133 |
3780 |
134 |
BM70 |
135 |
3.6mA;4.0mA;20mA;22mA;Other;End |