0 |
UltimaXEH |
1 |
MSA |
2 |
PV Out of Limit |
3 |
HELP - Bit 0 |
4 |
Non PV- Out of Limit |
5 |
HELP - Bit 1 |
6 |
PV Analog Out - Saturated |
7 |
HELP - Bit 2 |
8 |
PV Analog Out - Fixed |
9 |
HELP - Bit 3 |
10 |
More Staus Available |
11 |
HELP - Bit 4 |
12 |
Cold Start |
13 |
HELP - Bit 5 |
14 |
Config Changed |
15 |
HELP - Bit 6 |
16 |
Device Malfunction |
17 |
HELP - Bit 7 |
18 |
Configuration Reset |
19 |
Main ram fault |
20 |
Main flash fault |
21 |
EEprom write error |
22 |
Incompatible sensor |
23 |
Sensor quick underrange |
24 |
Sensor underrange |
25 |
Calibration fault |
26 |
Sensor Missing |
27 |
No sensor detected |
28 |
Sensor Overrange |
29 |
Sensor reading overrange! |
30 |
Sensor in Overrange Loc |
31 |
Combustible sensor in overrange lock! |
32 |
Sensor Parameter Fault |
33 |
Sensor Warm up |
34 |
Sensor Warming up |
35 |
Sensor Config Reset |
36 |
Sensor Configuration has been reset |
37 |
Sensor Power Fault |
38 |
Sensor Power Fault detected |
39 |
5V Power Fault |
40 |
Main board 5V Power Fault detected |
41 |
Zero Countdn |
42 |
Cal- 30sec Zero Countdn |
43 |
Apply Zero Gas |
44 |
Cal- Waiting for Zero Gas |
45 |
Span Countdn |
46 |
Cal- 30s Span Countdn |
47 |
Apply Span Gas |
48 |
Cal- Waiting for Span Gas |
49 |
Cal Aborted |
50 |
Calibration sequence aborted |
51 |
Zero Fault |
52 |
Sensor failed Zero Cal |
53 |
Span Fault |
54 |
Sensor failed Span Cal |
55 |
Cal OK |
56 |
Calibration Successful |
57 |
Change Snsr Warn |
58 |
Sensor End Of Life Warning |
59 |
Snsr Swap Delay |
60 |
Sensor missing error held off during 2 min sensor Swap Delay, |
61 |
Change Snsr Fault |
62 |
Sensor End of Life indication |
63 |
Snsr Pwr Fault |
64 |
Sensor input voltage out of 7-30 volt range |
65 |
Device Comm Fault |
66 |
Sensor internal communications fault detected |
67 |
Cal Signal Enable |
68 |
Sets output set to 3.75 ma during cal and for 1 min after cal |
69 |
Alert Option Enable |
70 |
Alert option on sets cal output to 21 ma when Cal sig enabled |
71 |
Relay Fault |
72 |
Relay Fault indication |
73 |
Alarm1 Set |
74 |
Alarm 1 limit exceeded! |
75 |
Alarm2 Set |
76 |
Alarm 2 limit exceeded! |
77 |
Alarm3 Set |
78 |
Not Used |
79 |
Not Used |
80 |
Sensor Value(PV) |
81 |
.2f |
82 |
Snsr Dev Fmly |
83 |
Snsr Class |
84 |
Snsr PDQ |
85 |
Snsr LS |
86 |
Snsr Fmly Stat |
87 |
Snsr Upper Limit |
88 |
Snsr Lower Limit |
89 |
Snsr Minimum Span |
90 |
Snsr Damping |
91 |
.3f |
92 |
8.3f |
93 |
Sensor Serial Number |
94 |
7d |
95 |
Snsr Lower Trim |
96 |
Snsr Upper Trim |
97 |
4.2f |
98 |
Snsr Trim Support |
99 |
Snsr Min Lower Trim |
100 |
Snsr Max Lower Trim |
101 |
Snsr Min Upper Trim |
102 |
Snsr Max Upper Trim |
103 |
Snsr Min Trim Diff |
104 |
Gas Snsr |
105 |
Input Voltage |
106 |
Input voltage monitor |
107 |
volts |
108 |
.1f |
109 |
Gas Table |
110 |
Gas specific calibration look up table |
111 |
Methane |
112 |
Uses methane analyte curve |
113 |
Propane |
114 |
Uses propane analyte curve |
115 |
Ethane |
116 |
Uses ethane analyte curve |
117 |
n-Butane |
118 |
Uses n-butane analyte curve |
119 |
n-Pentane |
120 |
Uses n-pentane analyte curve |
121 |
n-Hexane |
122 |
Uses n-hexane analyte curve |
123 |
Cyclopentane |
124 |
Uses cyclopentane analyte curve |
125 |
Ethylene |
126 |
Uses ethylene analyte curve |
127 |
Acetylene |
128 |
Uses acetylene analyte curve |
129 |
5000 PPM CO2 |
130 |
Uses 5000PPM CO2 analyte curve |
131 |
5% CO2 |
132 |
Uses 5% CO2 analyte curve |
133 |
2% CO2 |
134 |
Uses 2% CO2 analyte curve |
135 |
Custom |
136 |
Uses custom analyte curve |
137 |
Unused |
138 |
Gas tables unused |
139 |
RTC Hrs |
140 |
Real time clock - hours |
141 |
hrs |
142 |
2d |
143 |
3d |
144 |
RTC Minutes |
145 |
Real time clock - minutes |
146 |
mins |
147 |
Min Value |
148 |
Minimum gas value reading recorded during average interval. |
149 |
Max Value |
150 |
Maximum gas reading recorded during average interval. |
151 |
Avg Value |
152 |
Average gas reading recorded during the average interval |
153 |
Avg Interval |
154 |
Time interval in hours(1,8, or 24) for which the min, max and average values are accumulated. |
155 |
hr |
156 |
Alm1 Setpoint |
157 |
Gas level at which alarm 1 will be set |
158 |
Alm2 Setpoint |
159 |
Gas level at which alarm 2 will be set |
160 |
Alm3 Setpoint |
161 |
Gas level at which alarm 3 will be set |
162 |
Setpoint Edit Val |
163 |
|
164 |
Alm Edit Num |
165 |
number of the alarm to be edited(1,2 or 3) |
166 |
Alarm Actions |
167 |
Defines the direction, latch and enable modes of the setpoint alarm |
168 |
Alarm enable |
169 |
Alarm - enabled = 1 |
170 |
Alarm increasing |
171 |
Alarm - increasing = 1, decreasing = 0 |
172 |
Alarm latching |
173 |
Alarm - latching = 1 |
174 |
Alm1 Actions |
175 |
Setpoint alarm 1 control actions |
176 |
Alm 1 enable |
177 |
Alarm 1 - enabled = 1 |
178 |
Alm 1 inc |
179 |
Alarm 1 - increasing = 1, decreasing = 0 |
180 |
Alm 1 latch |
181 |
Alarm 1 - latching = 1 |
182 |
Alm2 Actions |
183 |
Setpoint alarm 2 control actions |
184 |
Alm 2 enable |
185 |
Alarm 2 - enabled = 1 |
186 |
Alm 2 inc |
187 |
Alarm 2 - increasing = 1, decreasing = 0 |
188 |
Alm 2 latch |
189 |
Alarm 2 - latching = 1 |
190 |
Alm3 Actions |
191 |
Setpoint alarm 3 control actions |
192 |
Alm 3 enable |
193 |
Alarm 3 - enabled = 1 |
194 |
Alm 3 inc |
195 |
Alarm 3 - increasing = 1, decreasing = 0 |
196 |
Alm 3 latch |
197 |
Alarm 3 - latching = 1 |
198 |
Cal Mode |
199 |
Calibration mode selection variable |
200 |
Sensor Zero |
201 |
Initiates sensor Zero sequence |
202 |
Standard Cal |
203 |
Iniiates a Standard Zero and Span sequence |
204 |
Initial Cal |
205 |
Initiates an Initial Zero and Span sequence |
206 |
User Cal |
207 |
Initiates a manual User controlled cal sequence |
208 |
Cal Abort |
209 |
Calibration abort command byte |
210 |
Step Cal |
211 |
Calibration step command byte |
212 |
Alm Ack |
213 |
Alarm acknowledge command byte |
214 |
Auto Zero Comp |
215 |
Indicates the amount of automatic zero compensation added since last calibration |
216 |
Last Cal Date |
217 |
Indicates the date the sensor module was last calibrated |
218 |
Cal Signal |
219 |
When enabled, causes the 4-20 ma to be set to 3.75 ma during calibration |
220 |
Disabled |
221 |
Causes the output 4-20 ma signal to follow the gas reading during Cal |
222 |
Enabled |
223 |
Causes the output 4-20 ma to be set to 3.75 ma during Cal( 21 ma for Oxygen) |
224 |
Swap Delay |
225 |
Enables a 1 min hold off on sensor missing status bit and output current fault during sensor exchange |
226 |
Enables immediate Sensor Missing status bit on loss of sensor communication |
227 |
Enables a 1 min hold off on sensor missing status bit and output current fault during sensor exchange |
228 |
dataResetCmd |
229 |
Sensor data sheet reset command byte |
230 |
Sensor Status |
231 |
Status message from sensor module to transmitter |
232 |
SNSR Flash Flt |
233 |
help |
234 |
SNSR RAM Flt |
235 |
SNSR Pellement Flt |
236 |
SNSR TEDS Chksum Flt |
237 |
SNSR Pwr Flt |
238 |
SNSR IR Factory Mode |
239 |
SNSR IR Lamp Flt |
240 |
SNSR EEPROM R/W Flt |
241 |
SNSR EEPROM Chksum Flt |
242 |
SNSR Missing Flt |
243 |
SNSR Neg Pwr Flt |
244 |
SNSR IR Ref Flt |
245 |
SNSR Temp Flt |
246 |
SNSR IR Analyt Flt |
247 |
SNSR IR Low Sig Flt |
248 |
SNSR IR Param Flt |
249 |
SNSR Cal Flt |
250 |
SNSR Zero Mode |
251 |
SNSR Span Mode |
252 |
SNSR Sleep Mode |
253 |
SNSR Warm Up Mode |
254 |
SNSR POR Mode |
255 |
SNSR OK |
256 |
Snsr Temp |
257 |
Temperature reading from sensor module |
258 |
C |
259 |
Alert Option |
260 |
Sets output to 3.75 ma during cal of an Oxygen sensor if Cal sig is also enabled) |
261 |
Causes the output 4-20 ma to be set to 3.75 ma during Cal of an Oxygen sensor if Cal signal is enabled) |
262 |
Write Protect Mode |
263 |
Write protects device preventing variables or calibration from being changed |
264 |
Device write protection is disabled |
265 |
Device write protection is enabled |
266 |
Relay Settings |
267 |
Relay setting normally energized/de-energized. |
268 |
Relay 1 |
269 |
Relay 1 - Engergized = 1, De-Energized = 0 |
270 |
Relay 2 |
271 |
Relay 2 - Energized = 1, De-Energized = 0 |
272 |
Relay 3 |
273 |
Relay 3 - Energized = 1, De-Energized = 0 |
274 |
DR_Initiate |
275 |
DR_Running |
276 |
DR_Conflict |
277 |
Sensor Calibration |
278 |
Abort Cal |
279 |
aborts device calibration sequence |
280 |
cal fault |
281 |
Alarm Function Edit |
282 |
Changes the alarm function controls |
283 |
Setpoint Edit |
284 |
Changes the device alarm level settings |
285 |
Clear Config Flag |
286 |
Clears device configuration flag |
287 |
Alarm Acknowledge |
288 |
Acknowledges latched alarms in the device |
289 |
Set Avg Interval |
290 |
Select a time collection interval for Min, Max and Average readings |
291 |
Sensor Reset |
292 |
Reset Sensor module to factory defaults |
293 |
Enable or disable device write protect mode |
294 |
Relay Edit |
295 |
Changes the relay state |
296 |
Re-range |
297 |
Sensor trim points |
298 |
Alarm Edit |
299 |
Clock edit |
300 |
Gas Sensor |
301 |
Edit Menu |
302 |
Cal Menu |
303 |
Swap Delay Edit |
304 |
Write Protect Edit |
305 |
8u |
306 |
count |
307 |
Select a Calibration Function: |
308 |
Sensor Zero;Zero/Span;Initial Cal;User Cal |
309 |
Initiating Calibration sequence.. %[5.2f]{value} %{0} %{1} |
310 |
Mode = Zero Sensor |
311 |
Mode = Standard Zero/Span Sensor |
312 |
Mode = Initial Cal Sensor |
313 |
Mode = User Cal Sensor |
314 |
Initiating Zero, 30 sec countdown...apply Zero Gas! %[5.2f]{value} %{0} %{1} |
315 |
Adjusting...Apply Zero Gas NOW! %[5.2f]{value} %{0} %{1} |
316 |
Select Refresh until Zero reading is stable, then STEP %[5.2f]{value} |
317 |
Step;Refresh |
318 |
Stepping...Please wait! %[5.2f]{value}%{0} %{1} |
319 |
Initiating Span, 30 sec countdown...apply Span Gas! %[5.2f]{value}%{0} %{1} |
320 |
Adjusting...apply Span Gas NOW! %[5.2f]{value}%{0} %{1} |
321 |
Select Refresh until Span reading is stable, then STEP %[5.2f]{value} |
322 |
ZERO fault! |
323 |
SPAN fault! |
324 |
Calibration Complete! %[5.2f]{value}%{0} %{1} |
325 |
Remove Calibration Gas NOW! %[5.2f]{value}%{0} %{1} |
326 |
Cal fault! %{result} |
327 |
Calibration Aborted! %[5.2f]{value}%{0} %{1} |
328 |
Remove Calibration Gas NOW! %[5.2f]{value}%{0} %{1} |
329 |
Calibration Error |
330 |
Select Alarm number to EDIT. |
331 |
Alarm1;Alarm2;Alarm3 |
332 |
Select function. |
333 |
Disable;Enable |
334 |
Select alarming direction. |
335 |
Decreasing;Increasing |
336 |
Select alarm latch function. |
337 |
Non-Latch;Latch |
338 |
Updating status... |
339 |
Alarm # %{almselection} Control status changed! |
340 |
Enter new Setpoint value for Alarm # %{almselection} . |
341 |
setpoint |
342 |
Setpoint value out of range! |
343 |
Alarm # %{almselection}, Setpoint Value %{setpoint} |
344 |
Configuration changed flag cleared |
345 |
Latched Alarms will be reset if gas level is below setpoint! |
346 |
Latched Alarms resetting, please wait! |
347 |
Latched Alarms have been acknowledged! |
348 |
Select an Average Interval: |
349 |
1 Hr;8 Hr;24 Hr |
350 |
New average interval is %{0} HR |
351 |
Sensor module RESET to defaults! |
352 |
Select Write Protection Mode. |
353 |
Write Protection has been disabled |
354 |
Write Protection has been enabled |
355 |
Selected state for Relay #1. |
356 |
Energized;De-Energized |
357 |
Selected state for Relay #2. |
358 |
Selected state for Relay #3. |
359 |
Relay state changed! |