Status summary |
5 |
Status summary- Data that has Field Device status information relating to: failures / warnings / status of process's. |
6 |
Sensor break |
7 |
Hardw/Firmw fail |
8 |
Reserved No Error |
9 |
Sensor Temp |
10 |
Oval flange |
11 |
Pres min span |
12 |
Pres USL |
13 |
Pres LSL |
14 |
316 SST/CF-8M SST |
15 |
Turcon-Variseal HF |
16 |
Copper |
17 |
Analog (spec scale) |
18 |
Analog (% linear) |
19 |
Digital |
20 |
Dig & analog (% lin) |
21 |
Dig & anl spec scale |
22 |
Lower Sensor Trim Point- Applied process pressureat which the last lower sensor trim was performed. |
23 |
Upper Sensor Trim Point- Applied process pressureat which the last upper sensor trim was performed. |
24 |
DrainVent/plug mat |
25 |
DrainVent/VentPlug Material- Construction material of the vent plug or a removable plug that exists on the flange type. |
26 |
Hast-C4 |
27 |
Silicone oil |
28 |
Silicone oil M50 |
29 |
High temp oil |
30 |
Inert |
31 |
Vegetable oil |
32 |
Halo Carbon oil |
33 |
Silicone oil gre free |
34 |
Hast-C276/SST |
35 |
Goldplated SST |
36 |
Diff (DP) PN 160 |
37 |
Gauge (GP) |
38 |
Diff (HP) PN 420 |
39 |
Draft rnge (DR) PN 32 |
40 |
Diff (DP) PN 320 |
41 |
Absolute |
42 |
Diff (DP) PN 240 |
43 |
Diff (DP) PN 315 |
44 |
Sq Rt, lin to Strtpt |
45 |
Sq Rt, 4mA to Strtpt |
46 |
Sq Rt, 2steps lin to Strtpt |
47 |
Extension length |
48 |
Extension length- Tube length of the Remote Seal. |
49 |
0 mm |
50 |
50 mm |
51 |
100 mm |
52 |
150 mm |
53 |
200 mm |
54 |
Enabled |
55 |
Disabled |
56 |
Zero only enabled |
57 |
Zero + span enabled |
58 |
316...SST |
59 |
431 SST |
60 |
Conn shank G1/2 A |
61 |
1/2-14NPTF |
62 |
1/4-18NPT, M12 |
63 |
1/4-18NPT,7/16-20UNF |
64 |
1/4-18NPT, M10 |
65 |
Han 7D plug compl |
66 |
Han 7D plug single |
67 |
Intrinsically safe
EEx ia IIC T4/T5/T6 |
68 |
Flame proof
EEx d IIC T5/T6 |
69 |
BASEEFA Ex N |
70 |
FM intrinsically safe |
71 |
FM explosion proof |
72 |
CSA intrinsically safe |
73 |
CSA explosion proof |
74 |
Ex-tested zone 2 |
75 |
FM intrinsically safe
+ explosion proof |
76 |
CSA intrinsically safe
+ explosion proof |
77 |
FM + CSA intrinsically safe
+ explosion proof |
78 |
Ex zone 2 (TÜV) |
79 |
Intrinsically safe
EEx ia + explosion proof EEx d (PTB) |
80 |
Startpoint square root- Determines the transition from linear resp. 4mA_constant to square root (Transfer Function). |
81 |
50000 kPa |
82 |
100000 kPa |
83 |
.4f |
84 |
.5f |
85 |
.2f |
86 |
.3f |
87 |
.6f |
88 |
.1f |
89 |
.7f |
90 |
.f |
91 |
.4g |
92 |
6.4f |
93 |
7.5f |
94 |
6.2f |
95 |
6.3f |
96 |
8.6f |
97 |
6.1f |
98 |
9.7f |
99 |
7.3f |
100 |
5.f |
101 |
7.1f |
102 |
7.4f |
103 |
7.2f |
104 |
10.4g |
105 |
5.3f |
106 |
7.f |
107 |
6.f |
108 |
°C |
109 |
Restore all defaults |
110 |
Restore DAC |
111 |
Restore Position Corr |
112 |
Restore Sensor Cal |
113 |
Execute Position Correction |
114 |
Execute write protection |
115 |
Span out of limits |
116 |
Master reset- Commands the SITRANS P electronics to reset. |
117 |
Status |
118 |
Upper AO limit- Defines the upper AO limit - from 20 mA to 22.0 mA. |
119 |
Upper AO limit |
120 |
4.1f |
121 |
5.2f |
122 |
Drain vent position- Position of the drain vent (opposite to process connection or at the side of process flange). |
123 |
Drain vent posit |
124 |
Opposite process con |
125 |
Side process flange |
126 |
Elect housing matl |
127 |
CF-8M SST |
128 |
Local Display unit |
129 |
0 |
130 |
50 |
131 |
100 |
132 |
150 |
133 |
200 |
134 |
Explos protection |
135 |
Explosion protection- Indicates the certification of the Field Device for the use in a hazardous area. |
136 |
Flameproof
EEx d IIC T5/T6 |
137 |
FM Intrinsically safe |
138 |
FM Explosionproof |
139 |
CSA Intrinsically safe |
140 |
CSA Explosionproof |
141 |
Process connection |
142 |
Process connection- Female thread and fastening screw thread (flange type). |
143 |
1/4-18NPT, 7/16-20UNF |
144 |
Electr connection |
145 |
Electr connection- Cable inlet. |
146 |
Pg 13.5 srew gland |
147 |
Fem thr M20 x 1.5 |
148 |
1/2-14 NPTF |
149 |
Han 7D plug |
150 |
Process flnge bolt |
151 |
Process flange bolts- Materials. |
152 |
Alrm LRV |
153 |
Alarm LRV- Low analog output alarm value (mA). |
154 |
Alrm URV |
155 |
Alarm URV- High analog output alarm value (mA). |
156 |
Startpoint sq root |
157 |
Startpoint square root- Determines the transition from linear to square root (Transfer Function). |
158 |
% |
159 |
factory trim values |
160 |
Restore Defaults |
161 |
Not Used |
162 |
RS fill fluid |
163 |
Remote Seal Fill Fluid- Fluid material in the device remote seal. |
164 |
Silicone oil M5 |
165 |
Vegetable oil |
166 |
Module rnge |
167 |
Module range- Measurement range of the module (unit kPa). |
168 |
|
169 |
2 kPa |
170 |
6 kPa |
171 |
25 kPa |
172 |
60 kPa |
173 |
100 kPa |
174 |
130 kPa |
175 |
160 kPa |
176 |
400 kPa |
177 |
500 kPa |
178 |
1600 kPa |
179 |
3000 kPa |
180 |
6300 kPa |
181 |
16000 kPa |
182 |
40000 kPa |
183 |
Temp |
184 |
Temp unit |
185 |
|
186 |
Index into Table 26 |
187 |
Index into Table 29 |
188 |
Model |
189 |
SITRANS P |
190 |
Num req preams |
191 |
Dev id |
192 |
Tag |
193 |
Date |
194 |
Write protect |
195 |
Final asmbly num |
196 |
Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device. |
197 |
8u |
198 |
Num resp preams |
199 |
Pressure unit |
200 |
Pres % rnge |
201 |
3.2f |
202 |
Pres USL |
203 |
Pres LSL |
204 |
Pres min span |
205 |
Pres xfer fnctn |
206 |
Sq root |
207 |
Pres URV |
208 |
Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. |
209 |
Pres LRV |
210 |
Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. |
211 |
Pres damp |
212 |
s |
213 |
4.2f |
214 |
Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. |
215 |
O ring matl |
216 |
O Ring Material- Construction material of a seal that exists between the module and flange. |
217 |
Local meter |
218 |
Local meter- Defines whether there is a meter installed or not and possibly what information the meter will display. |
219 |
Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. |
220 |
Flnge construction |
221 |
Flange + extension |
222 |
Cell construction |
223 |
Flange without ext |
224 |
Fill fluid |
225 |
Fill Fluid- Fluid material in the module. |
226 |
Num remote seal |
227 |
Number of Remote Seals- Physical quantity of installed Remote Seals. |
228 |
AO |
229 |
AO alrm typ |
230 |
Hi |
231 |
Lo |
232 |
Pres snsr s/n |
233 |
Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. 0 indicates, that there is currently no Sensor Serial Number determined, because the sensor is uniquely defined by the Device ID. |
234 |
Meas typ |
235 |
Measurement Type- Type of measurement application this Field Device is intended to be used with (Diff, Gauge, Absolute, Liquid-lvl). |
236 |
Draft rnge (DR) PN 32 |
237 |
Lower sensor trim point |
238 |
Lower Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. |
239 |
Upper sensor trim point |
240 |
Upper Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. |
241 |
Flnge matl |
242 |
Flange Material- Construction material of flange type. |
243 |
RS isoltr matl |
244 |
Remote Seal Isolator Material- Construction material of a part of the remote seal type that comes in contact with the process material. This is only unambiguous if 1 remote seal is installed. |
245 |
316Ti SST |
246 |
Zirconium |
247 |
Gold/SST |
248 |
Isoltr matl |
249 |
Sensor Isolator Material- Construction material of a part of the module type that comes in contact with the process material. |
250 |
Version RS |
251 |
Locl keys ctrl mod |
252 |
Local Keys Control Mode- Controls the mode of the User Interface keys on the Field Device. |
253 |
Drain vent matl |
254 |
Drain Vent Material- Construction material of a removable plug that exists on the flange type that can be opened temporarily to remove unwanted process from the sensor area. |
255 |
Device order num |
256 |
Device order num- Device Order number. Respects to the current configuration |
257 |
Selftest- Commands the SITRANS P electronics to perform a selftest. Reports any errors that occured. |
258 |
Device maybe stuck in selftest. |
259 |
Self test OK |
260 |
Master reset |
261 |
Master reset OK |
262 |
Restore mfgr trims |
263 |
Restore mfgr trims- User trims (Sensor, DAC) will be erased. Factory trims will be restored. |
264 |
Not restore;Restore, yes |
265 |
MFGR trims restored |
266 |
Apply values |
267 |
Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input. |
268 |
Loop test |
269 |
D/A trim |
270 |
Scaled D/A trim |
271 |
low |
272 |
high |
273 |
tmp_av |
274 |
Zero trim |
275 |
Zero trim- Make the sensor input the new zero input reference. The resulting offset must be within the defined limits. |
276 |
Send warning |
277 |
Send Warning- Yields a units code notice to the User. |
278 |
Variables which use this as the units code will be in the previous units until this value is sent to the device. |
279 |
Lower sensor trim |
280 |
Pressure Sensor Lower Trim- Calibrate the pressure sensor. |
281 |
Apply low pressure |
282 |
Press OK when pressure is stable |
283 |
Enter applied pressure value |
284 |
trim_point |
285 |
Remove pressure |
286 |
Upper sensor trim |
287 |
Pressure Sensor Upper Trim- Calibrate the pressure sensor. |
288 |
Apply hi pressure |
289 |
Exit Trim Mode- Notifies the User that the trim is finished. |
290 |
Trim was not done |
291 |
Write variables |
292 |
Device setup |
293 |
Basic setup |
294 |
Test/Status |
295 |
Sensors |
296 |
Signal condition |
297 |
Output condition |
298 |
Zero/Span set |
299 |
Temp sensor |
300 |
Sensor info |
301 |
Alarms |
302 |
Trim analog output |
303 |
Sensor trim points |
304 |
Hot key |
305 |
Construction matls |
306 |
Snsr |
307 |
Unit |
308 |
% rnge |
309 |
Min span |
310 |
Xfer fnctn |
311 |
USL |
312 |
LSL |
313 |
URV |
314 |
LRV |
315 |
Damp |
316 |
No specific error |
317 |
Update fail |
318 |
Device maybe stuck in selftest. |
319 |
Master Reset in
progress please wait |
320 |
Master reset OK |