0 |
Volume Flow |
1 |
Velocity of sound |
2 |
Mass Flow |
3 |
Flow speed |
4 |
Gain |
5 |
SNR |
6 |
Heat Flow |
7 |
Cold Flow |
8 |
Volume Flow 2 |
9 |
Volume Flow 12 |
10 |
Diag. Gain 1 |
11 |
Diag. SNR 1 |
12 |
Diag. Gain 2 |
13 |
Diag. SNR 2 |
14 |
Temperature A |
15 |
Temperature B |
16 |
Volume Totalizer 1 |
17 |
Mass Totalizer 1 |
18 |
Energy Totalizer 1 |
19 |
Volume 2 Totalizer 1 |
20 |
Volume Totalizer 2 |
21 |
Mass Totalizer 2 |
22 |
Volume 2 Totalizer 2 |
23 |
Volume 12 Totalizer 2 |
24 |
Volume Totalizer 3 |
25 |
Mass Totalizer 3 |
26 |
Energy Totalizer 3 |
27 |
Volume 12 Totalizer 3 |
28 |
Operating hours |
29 |
Snsr s/n |
30 |
Unit Volume Flow |
31 |
Unit for Volume Flow. |
32 |
Format Volume Flow |
33 |
Display format for Volume Flow.
Local for HART applications, no correlation with device's local display. |
34 |
#X.XX (default) |
35 |
#X. |
36 |
#X.X |
37 |
#X.XXX |
38 |
#X.XXXX |
39 |
#X.XXXXX |
40 |
#X.XXXXXX |
41 |
#X.XXXXXXX |
42 |
#X.XXXXXXXX |
43 |
exponential format |
44 |
auto format |
45 |
Volume Flow |
46 |
Volume Flow current measurement. |
47 |
.0f |
48 |
.1f |
49 |
.2f |
50 |
.3f |
51 |
.4f |
52 |
.5f |
53 |
.6f |
54 |
.7f |
55 |
.8f |
56 |
6e |
57 |
g |
58 |
Time constant |
59 |
Time constant for Volume Flow |
60 |
Upper Sensor Limit |
61 |
Lower Sensor Limit |
62 |
Minimum Span |
63 |
Class Volume Flow |
64 |
Device Variable Class.
Defines also the set of selectable physical units. |
65 |
Family |
66 |
Device Variable Family |
67 |
Data Quality |
68 |
Process Data Quality 'PDQ' |
69 |
Limit Status |
70 |
Limit Status 'LS' |
71 |
Family Status |
72 |
Family Status 'FS' |
73 |
More device family status available |
74 |
Update Time |
75 |
Update Time Period 'UTP'.
Indicates the maximum period between updates of the process variable. |
76 |
Properties |
77 |
Properties, indicate e.g. the simulation state. |
78 |
Computed extern |
79 |
Process Variable is not calculated by the field device. |
80 |
Simulated |
81 |
Current state of the process variable simulation.
If active, the process variable is simulated and doesn't show the actual process value. |
82 |
Unit Velocity of sound |
83 |
Unit for Velocity of sound. |
84 |
Format Velocity of sound |
85 |
Display format for Velocity of sound.
Local for HART applications, no correlation with device's local display. |
86 |
Velocity of sound |
87 |
Velocity of sound current measurement. |
88 |
Time constant for Velocity of sound |
89 |
Class Velocity of sound |
90 |
Unit Mass Flow |
91 |
Unit for Mass Flow. |
92 |
Format Mass Flow |
93 |
Display format for Mass Flow.
Local for HART applications, no correlation with device's local display. |
94 |
Mass Flow |
95 |
Mass Flow current measurement. |
96 |
Time constant for Mass Flow |
97 |
Class Mass Flow |
98 |
Unit Flow speed |
99 |
Unit for Flow speed. |
100 |
Format Flow speed |
101 |
Display format for Flow speed.
Local for HART applications, no correlation with device's local display. |
102 |
Flow speed |
103 |
Flow speed current measurement. |
104 |
Time constant for Flow speed |
105 |
Class Flow speed |
106 |
Unit Decibel |
107 |
Unit for Decibel. |
108 |
dB |
109 |
Decibel |
110 |
Format Gain |
111 |
Display format for Gain.
Local for HART applications, no correlation with device's local display. |
112 |
Gain |
113 |
Gain current measurement. |
114 |
Time constant for Gain |
115 |
Class Gain |
116 |
Format SNR |
117 |
Display format for SNR.
Local for HART applications, no correlation with device's local display. |
118 |
SNR |
119 |
SNR current measurement. |
120 |
Time constant for SNR |
121 |
Class SNR |
122 |
Unit Heat Flow |
123 |
Unit for Heat Flow. |
124 |
MW |
125 |
Mega Watt |
126 |
Mbtu/h |
127 |
Million British thermal units per hour |
128 |
Format Heat Flow |
129 |
Display format for Heat Flow.
Local for HART applications, no correlation with device's local display. |
130 |
Heat Flow |
131 |
Heat Flow current measurement. |
132 |
Time constant for Heat Flow |
133 |
Class Heat Flow |
134 |
power_classification |
135 |
Unit Cold Flow |
136 |
Unit for Cold Flow. |
137 |
Format Cold Flow |
138 |
Display format for Cold Flow.
Local for HART applications, no correlation with device's local display. |
139 |
Cold Flow |
140 |
Cold Flow current measurement. |
141 |
Time constant for Cold Flow |
142 |
Class Cold Flow |
143 |
Format Volume Flow 2 |
144 |
Display format for Volume Flow 2.
Local for HART applications, no correlation with device's local display. |
145 |
Volume Flow 2 |
146 |
Volume Flow 2 current measurement. |
147 |
Time constant for Volume Flow 2 |
148 |
Class Volume Flow 2 |
149 |
Format Volume Flow 12 |
150 |
Display format for Volume Flow 12.
Local for HART applications, no correlation with device's local display. |
151 |
Volume Flow 12 |
152 |
Volume Flow 12 current measurement. |
153 |
Time constant for Volume Flow 12 |
154 |
Class Volume Flow 12 |
155 |
Format Diag. Gain 1 |
156 |
Display format for Diag. Gain 1.
Local for HART applications, no correlation with device's local display. |
157 |
Diag. Gain 1 |
158 |
Diag. Gain 1 current measurement. |
159 |
Time constant for Diag. Gain 1 |
160 |
Class Diag. Gain 1 |
161 |
Format Diag. SNR 1 |
162 |
Display format for Diag. SNR 1.
Local for HART applications, no correlation with device's local display. |
163 |
Diag. SNR 1 |
164 |
Diag. SNR 1 current measurement. |
165 |
Time constant for Diag. SNR 1 |
166 |
Class Diag. SNR 1 |
167 |
Format Diag. Gain 2 |
168 |
Display format for Diag. Gain 2.
Local for HART applications, no correlation with device's local display. |
169 |
Diag. Gain 2 |
170 |
Diag. Gain 2 current measurement. |
171 |
Time constant for Diag. Gain 2 |
172 |
Class Diag. Gain 2 |
173 |
Format Diag. SNR 2 |
174 |
Display format for Diag. SNR 2.
Local for HART applications, no correlation with device's local display. |
175 |
Diag. SNR 2 |
176 |
Diag. SNR 2 current measurement. |
177 |
Time constant for Diag. SNR 2 |
178 |
Class Diag. SNR 2 |
179 |
Format Temperature A |
180 |
Display format for Temperature A.
Local for HART applications, no correlation with device's local display. |
181 |
Temperature A |
182 |
Temperature A current measurement. |
183 |
Time constant for Temperature A |
184 |
Class Temperature A |
185 |
Format Temperature B |
186 |
Display format for Temperature B.
Local for HART applications, no correlation with device's local display. |
187 |
Temperature B |
188 |
Temperature B current measurement. |
189 |
Time constant for Temperature B |
190 |
Class Temperature B |
191 |
Unit Volume Totalizer 1 |
192 |
Unit for Volume Totalizer 1. |
193 |
Format Volume Totalizer 1 |
194 |
Display format for Volume Totalizer 1.
Local for HART applications, no correlation with device's local display. |
195 |
Volume Totalizer 1 |
196 |
Volume Totalizer 1 current measurement. |
197 |
Time constant for Volume Totalizer 1 |
198 |
Class Volume Totalizer 1 |
199 |
Unit Mass Totalizer 1 |
200 |
Unit for Mass Totalizer 1. |
201 |
Format Mass Totalizer 1 |
202 |
Display format for Mass Totalizer 1.
Local for HART applications, no correlation with device's local display. |
203 |
Mass Totalizer 1 |
204 |
Mass Totalizer 1 current measurement. |
205 |
Time constant for Mass Totalizer 1 |
206 |
Class Mass Totalizer 1 |
207 |
Unit Energy Totalizer 1 |
208 |
Unit for Energy Totalizer 1. |
209 |
GJ |
210 |
Giga Joules |
211 |
GWh |
212 |
Giga Watts per hour |
213 |
Format Energy Totalizer 1 |
214 |
Display format for Energy Totalizer 1.
Local for HART applications, no correlation with device's local display. |
215 |
Energy Totalizer 1 |
216 |
Energy Totalizer 1 current measurement. |
217 |
Time constant for Energy Totalizer 1 |
218 |
Class Energy Totalizer 1 |
219 |
Format Volume 2 Totalizer 1 |
220 |
Display format for Volume 2 Totalizer 1.
Local for HART applications, no correlation with device's local display. |
221 |
Volume 2 Totalizer 1 |
222 |
Volume 2 Totalizer 1 current measurement. |
223 |
Time constant for Volume 2 Totalizer 1 |
224 |
Class Volume 2 Totalizer 1 |
225 |
Unit Volume Totalizer 2 |
226 |
Unit for Volume Totalizer 2. |
227 |
Format Volume Totalizer 2 |
228 |
Display format for Volume Totalizer 2.
Local for HART applications, no correlation with device's local display. |
229 |
Volume Totalizer 2 |
230 |
Volume Totalizer 2 current measurement. |
231 |
Time constant for Volume Totalizer 2 |
232 |
Class Volume Totalizer 2 |
233 |
Unit Mass Totalizer 2 |
234 |
Unit for Mass Totalizer 2. |
235 |
Format Mass Totalizer 2 |
236 |
Display format for Mass Totalizer 2.
Local for HART applications, no correlation with device's local display. |
237 |
Mass Totalizer 2 |
238 |
Mass Totalizer 2 current measurement. |
239 |
Time constant for Mass Totalizer 2 |
240 |
Class Mass Totalizer 2 |
241 |
Format Volume 2 Totalizer 2 |
242 |
Display format for Volume 2 Totalizer 2.
Local for HART applications, no correlation with device's local display. |
243 |
Volume 2 Totalizer 2 |
244 |
Volume 2 Totalizer 2 current measurement. |
245 |
Time constant for Volume 2 Totalizer 2 |
246 |
Class Volume 2 Totalizer 2 |
247 |
Format Volume 12 Totalizer 2 |
248 |
Display format for Volume 12 Totalizer 2.
Local for HART applications, no correlation with device's local display. |
249 |
Volume 12 Totalizer 2 |
250 |
Volume 12 Totalizer 2 current measurement. |
251 |
Time constant for Volume 12 Totalizer 2 |
252 |
Class Volume 12 Totalizer 2 |
253 |
Unit Volume Totalizer 3 |
254 |
Unit for Volume Totalizer 3. |
255 |
Format Volume Totalizer 3 |
256 |
Display format for Volume Totalizer 3.
Local for HART applications, no correlation with device's local display. |
257 |
Volume Totalizer 3 |
258 |
Volume Totalizer 3 current measurement. |
259 |
Time constant for Volume Totalizer 3 |
260 |
Class Volume Totalizer 3 |
261 |
Unit Mass Totalizer 3 |
262 |
Unit for Mass Totalizer 3. |
263 |
Format Mass Totalizer 3 |
264 |
Display format for Mass Totalizer 3.
Local for HART applications, no correlation with device's local display. |
265 |
Mass Totalizer 3 |
266 |
Mass Totalizer 3 current measurement. |
267 |
Time constant for Mass Totalizer 3 |
268 |
Class Mass Totalizer 3 |
269 |
Unit Energy Totalizer 3 |
270 |
Unit for Energy Totalizer 3. |
271 |
Format Energy Totalizer 3 |
272 |
Display format for Energy Totalizer 3.
Local for HART applications, no correlation with device's local display. |
273 |
Energy Totalizer 3 |
274 |
Energy Totalizer 3 current measurement. |
275 |
Time constant for Energy Totalizer 3 |
276 |
Class Energy Totalizer 3 |
277 |
Format Volume 12 Totalizer 3 |
278 |
Display format for Volume 12 Totalizer 3.
Local for HART applications, no correlation with device's local display. |
279 |
Volume 12 Totalizer 3 |
280 |
Volume 12 Totalizer 3 current measurement. |
281 |
Time constant for Volume 12 Totalizer 3 |
282 |
Class Volume 12 Totalizer 3 |
283 |
Unit Operating hours |
284 |
Unit for Operating hours. |
285 |
Format Operating hours |
286 |
Display format for Operating hours.
Local for HART applications, no correlation with device's local display. |
287 |
Operating hours |
288 |
Operating hours current measurement. |
289 |
Time constant for Operating hours |
290 |
Class Operating hours |
291 |
eSelectionAnalogOutput |
292 |
PV |
293 |
SV |
294 |
TV |
295 |
QV |
296 |
eSelectionCurrentOutput |
297 |
4.1f |
298 |
Upper Limit Value |
299 |
The maximum value of the analog signal. |
300 |
Lower Limit Value |
301 |
The minimum value of the analog signal. |
302 |
SV % range |
303 |
Percent of range of the HART Secondary Variable (SV); tracks the associated measured value with respect to the Lower Range Value and Upper Range Value. |
304 |
8.3f |
305 |
SV output value |
306 |
Analog input |
307 |
TV % range |
308 |
TV output value |
309 |
QV % range |
310 |
QV output value |
311 |
UFC300 V2 |
312 |
ms |
313 |
Milliseconds |
314 |
Pa*s |
315 |
Pascalsecond |
316 |
Failure |
317 |
Operational fault in device. No measurement possible.
(NE 107 status signal). |
318 |
Function Check |
319 |
Testing mode by invoking test or simulation functions.
(NE 107 status signal). |
320 |
Out of Specification |
321 |
Out of specification, measurement continues with less accuracy.
(NE 107 status signal). |
322 |
Device Status Simulation |
323 |
The displayed device status is simulated and does not show the actual state. |
324 |
Config: No Meas.Value |
325 |
Electr: Operation Info. |
326 |
Proc: Current Input |
327 |
Electr: IO Connection |
328 |
Proc: Empty Pipe |
329 |
Proc: Signal Lost |
330 |
Proc: Signal Unreliable |
331 |
Config: Totaliser |
332 |
Installation required |
333 |
Electr: Power Failure |
334 |
S Electronics |
335 |
S Configuration |
336 |
S Process |
337 |
M Sensor |
338 |
M Electronics |
339 |
M Configuration |
340 |
F Electronics |
341 |
F Configuration |
342 |
C Configuration |
343 |
Analog Input Channel |
344 |
Set Loop to manual |
345 |
Apply values |
346 |
Currently measured values will be taken as Upper Range Value and Lower Range Value for the PV current output. |
347 |
D/A trim PV |
348 |
Calibration of the PV current output with an external reference. |
349 |
Primary Index into the Dynamic Variables Array. Indicates which process value is mapped into the HART Primary Variable (PV). |
350 |
Secondary Index into the Dynamic Variables Array. Indicates which process value is mapped into the HART Secondary Variable (SV). |
351 |
Tertiary Index into the Dynamic Variables Array. Indicates which process value is mapped into the HART Tertiary Variable (TV). |
352 |
QV is |
353 |
Quaternary Index into the Dynamic Variables Array. Indicates which process value is mapped into the HART Quaternary Variable (QV). |
354 |
Fix analog output |
355 |
Manually manipulate a selected Analog Output to a selected constant output value. |
356 |
D/A trim Analog Output |
357 |
Calibration of a selected output with an external reference. |
358 |
Device's date setting |
359 |
Device's time setting |
360 |
%H:%M |
361 |
Online Mode? |
362 |
Can the Host Application currently communicate with the field device? |
363 |
yes |
364 |
no |
365 |
DD-Version |
366 |
Version number of the device description according to NAMUR recommendation.
You are currently working with version: 01.11 |
367 |
01.11 |
368 |
PreSetVersionDd |
369 |
Reset Configuration Changed Flag |
370 |
Reset of the HART 'Configuration Changed' flag. |
371 |
Device reset |
372 |
Perform a "cold start" (like power-on start). |
373 |
Set Date and Time |
374 |
Sets device's date & time setting. |
375 |
averaging |
376 |
averaging
(D1.6) |
377 |
window path 1 |
378 |
window path 1
(D1.1) |
379 |
detection path 1 |
380 |
detection path 1
(D1.2) |
381 |
window path 2 |
382 |
window path 2
(D1.3) |
383 |
detection path 2 |
384 |
detection path 2
(D1.4) |
385 |
transducer sets |
386 |
transducer sets
(X9, C3) |
387 |
signal data |
388 |
signal data
(D1) |
389 |
service calibration |
390 |
service calibration
(D2) |
391 |
zero instrument |
392 |
zero instrument
(D2.1) |
393 |
service info |
394 |
service info
(D4) |
395 |
DSP sets |
396 |
DSP sets
(D1.10) |
397 |
display |
398 |
1. meas. page |
399 |
2. meas. page |
400 |
graphic page |
401 |
Bar graph |
402 |
Bar graph menu.
Displays the process variable as a bar graph. |
403 |
Trend |
404 |
Trend menu.
Displays the trend of the process variable. |
405 |
Chart |
406 |
Chart menu.
Provides graphical display of the process variable. |
407 |
Volume Flow HART device variable |
408 |
Velocity of sound HART device variable |
409 |
Mass Flow HART device variable |
410 |
Flow speed HART device variable |
411 |
Gain HART device variable |
412 |
SNR HART device variable |
413 |
Heat Flow HART device variable |
414 |
Cold Flow HART device variable |
415 |
Volume Flow 2 HART device variable |
416 |
Volume Flow 12 HART device variable |
417 |
Diag. Gain 1 HART device variable |
418 |
Diag. SNR 1 HART device variable |
419 |
Diag. Gain 2 HART device variable |
420 |
Diag. SNR 2 HART device variable |
421 |
Temperature A HART device variable |
422 |
Temperature B HART device variable |
423 |
Volume Totalizer 1 HART device variable |
424 |
Mass Totalizer 1 HART device variable |
425 |
Energy Totalizer 1 HART device variable |
426 |
Volume 2 Totalizer 1 HART device variable |
427 |
Volume Totalizer 2 HART device variable |
428 |
Mass Totalizer 2 HART device variable |
429 |
Volume 2 Totalizer 2 HART device variable |
430 |
Volume 12 Totalizer 2 HART device variable |
431 |
Volume Totalizer 3 HART device variable |
432 |
Mass Totalizer 3 HART device variable |
433 |
Energy Totalizer 3 HART device variable |
434 |
Volume 12 Totalizer 3 HART device variable |
435 |
Operating hours HART device variable |
436 |
PV Output |
437 |
Bar graph menu.
Displays the analog signal as a bar graph. |
438 |
Trend menu.
Displays the trend of the analog signal. |
439 |
Chart menu.
Provides graphical display of the analog signal. |
440 |
PV Analog Channel |
441 |
HART analog channel setup menu.
Provides access to parameters and functions of the analog channel (e.g. current output) of a HART dynamic variable. |
442 |
Primary |
443 |
HART Primary Variable (PV), the first element of the Dynamic Variables Array.
Equivalent to the process value of the current output. |
444 |
SV Output |
445 |
SV Analog Channel |
446 |
Secondary |
447 |
HART Secondary Variable (SV), the second element of the Dynamic Variables Array.
Equivalent to the process value of the frequency output if available. |
448 |
TV Output |
449 |
TV Analog Channel |
450 |
Tertiary |
451 |
HART Tertiary Variable (TV), the third element of the Dynamic Variables Array.
Equivalent to the process value of the current input if available. |
452 |
QV Output |
453 |
QV Analog Channel |
454 |
Quaternary |
455 |
HART Quaternary Variable (QV), the fourth element of the Dynamic Variables Array.
Not related to any physical in-/output. |
456 |
Time and simulation |
457 |
Process Values |
458 |
Sensor Limits |
459 |
Totalizer |
460 |
Diagnosis Values |
461 |
In-/Outputs, HART Dynamic Variables |
462 |
In-/Outputs (Chart) |
463 |
In-/Output (Bar) |
464 |
In-/Output (Scope) |
465 |
Process Values (Chart) |
466 |
Process Values (Bar) |
467 |
Process Values (Scope) |
468 |
Diagnosis Values (Chart) |
469 |
Diagnosis Values (Bar) |
470 |
Diagnosis Values (Scope) |
471 |
HART |
472 |
I/O HART |
473 |
Mapping of Dynamic Variables |
474 |
Set the mapping of the HART Dynamic Variables PV, SV, TV and QV.
There is a direct relation between the HART Dynamic Variables and the process values of the device's in-/outputs. |
475 |
Preliminary content |
476 |
The content of this menu is only preliminary |
477 |
Off |
478 |
Function switched off |
479 |
|
480 |
No valid items |
481 |
This menu contains no valid items. |
482 |
Process Variables |
483 |
Diagnostics |
484 |
Device Settings |
485 |
Device Setup root menu.
Provides access to device setup (commissioning, calibration, configuration, parameterization etc.) |
486 |
Offline |
487 |
<Image> Manufacturer |
488 |
<Image> Device |
489 |
<Image> Process Input Orientation |
490 |
<Image> Sensor Orientation |
491 |
<Image> PI Calibration Orientation |
492 |
<Image> PI Filter Orientation |
493 |
<Image> PI Selftest Orientation |
494 |
<Image> Current Output Orientation |
495 |
<Image> Frequency Output Orientation |
496 |
<Image> Status Output Orientation |
497 |
<Image> Control Input Orientation |
498 |
<Image> Totalizer Orientation |
499 |
<Image> Selection IO Orientation |
500 |
<Image> Display Orientation |
501 |
<Image> HART Orientation |
502 |
<Image> Diagnosis Active |
503 |
<Image> Failure Status |
504 |
<Image> Maintenance Required Status |
505 |
<Image> Out Of Specification Status |
506 |
<Image> Function Check Status |
507 |
Identification |
508 |
Identification menu.
Allows access to various identification information. |
509 |
Operating Unit |
510 |
Operating Unit Identification menu.
Provides access to operating unit related identification information. |
511 |
Device |
512 |
Device Identification menu.
Provides access to device related identification information. |
513 |
HART Identification menu.
Provides access to HART related identification information. |
514 |
Simulation |
515 |
Quick Setup |
516 |
General |
517 |
Reset |
518 |
Detailed Setup |
519 |
Service |
520 |
service |
521 |
service
(D) |
522 |
Debug DD |
523 |
Test/Reset |
524 |
Test and reset menu.
Provides access to test and reset functions. |
525 |
HART analog channels |
526 |
HART analog channels simulation menu.
Provides access to simulation functions for the HART analog channels, e.g. current output. |
527 |
Provides access to general parameters |
528 |
HART units |
529 |
Identification & Info |
530 |
Connection |
531 |
Connection setup menu.
Provides access to connection related information and settings. |
532 |
Device info |
533 |
HART Revisions |
534 |
Preambles |
535 |
Information |
536 |
device |
537 |
device
(C7) |
538 |
device info |
539 |
device info
(C7.1) |
540 |
special functions |
541 |
special functions
(C7.6) |
542 |
Service Access |
543 |
service parameters |
544 |
service parameters
(D3) |
545 |
no content |
546 |
I/O |
547 |
simulation IO |
548 |
hardware |
549 |
off |
550 |
current out A |
551 |
frequency out A |
552 |
pulse output A |
553 |
status output A |
554 |
limit switch A |
555 |
control input A |
556 |
current in A |
557 |
current out B |
558 |
frequency out B |
559 |
pulse output B |
560 |
status output B |
561 |
limit switch B |
562 |
control input B |
563 |
current in B |
564 |
current out C |
565 |
status output C |
566 |
limit switch C |
567 |
frequency out D |
568 |
pulse output D |
569 |
status output D |
570 |
limit switch D |
571 |
Process Input |
572 |
process input 2 |
573 |
Actual Values |
574 |
pipe data |
575 |
transducer data |
576 |
calibration |
577 |
filter |
578 |
plausibility |
579 |
simulation |
580 |
information |
581 |
diagnosis |
582 |
diagnosis
(C2.10) |
583 |
Device Status |
584 |
Device Status menu.
Provides access to the current device status. |
585 |
Condensed Status (NE 107) |
586 |
Standard |
587 |
Failure ('F') |
588 |
|
589 |
Function Check ('C') |
590 |
Out of Specification ('S') |
591 |
Maintenance Required ('M') |
592 |
Device Specific |
593 |
Variable F/C/S/M |
594 |
Device status simulation menu.
Provides access to simulation functions for the device status. |
595 |
Simulation Values |
596 |
Select the Bits that should be simulated |
597 |
Current Device Status |
598 |
Shows the current Device Status |
599 |
Status Mapping |
600 |
Status mapping menu.
Provides access to the mapping of device status into the indicators of the HART condensed status according to NAMUR NE107. |
601 |
I/O Totalizer |
602 |
totalizer 1 |
603 |
totalizer 2 |
604 |
totalizer 3 |
605 |
units |
606 |
units
(C7.7) |
607 |
Auxiliary Units |
608 |
method |
609 |
method
(D1.3.1) |
610 |
automatic |
611 |
semi-automatic |
612 |
manual |
613 |
flow direction |
614 |
flow direction
(C2.6.2) |
615 |
normal direction |
616 |
reverse direction |
617 |
density |
618 |
(X5.11.1, C1.3.10.1) |
619 |
VoS fluid |
620 |
(X5.10.1, X7.5.1, C1.3.9.1) |
621 |
dynamic viscosity |
622 |
(X5.13.1, C1.3.12.1) |
623 |
LFC threshold |
624 |
(C1.6.4.1) |
625 |
LFC hysterese |
626 |
(C1.6.4.2) |
627 |
limitation max |
628 |
(C1.6.1.2) |
629 |
limitation min |
630 |
(C1.6.1.1) |
631 |
VoS liner material |
632 |
(X5.7.1, C1.3.6.1) |
633 |
numb. traverses 1 |
634 |
number of traverses
(X8) |
635 |
1 traverse |
636 |
2 traverses |
637 |
4 traverses |
638 |
diameter |
639 |
(X5.2.1, C1.3.1.1) |
640 |
VoS pipe material |
641 |
(X5.4.1, C1.3.3.1) |
642 |
wall thickness |
643 |
(X5.5.1, C1.3.4.1) |
644 |
Reynolds correction |
645 |
Reynolds correction
(C2.5.3) |
646 |
on |
647 |
dynamic |
648 |
actual distance 1 |
649 |
(X7.1, X7.6.1, B2.11.1, B2.11.1.1, C1.4.3.1) |
650 |
transducer set 1 |
651 |
transducer set
(X8) |
652 |
Ta |
653 |
Tb |
654 |
Tc |
655 |
none |
656 |
liner thickness |
657 |
(X5.8.1, C1.3.7.1) |
658 |
pipe material |
659 |
(X5.3, C1.3.2) |
660 |
carbon steel |
661 |
stainless steel |
662 |
cast iron |
663 |
aluminum |
664 |
asbestos cement |
665 |
concrete |
666 |
acrylics |
667 |
PP/PVC |
668 |
polyamide |
669 |
GRP/FRP |
670 |
other |
671 |
|
672 |
liner material |
673 |
(X5.6, C1.3.5) |
674 |
LDPE |
675 |
PTFE |
676 |
HDPE |
677 |
rubber |
678 |
epoxy |
679 |
cement |
680 |
fluid |
681 |
(X5.9, C1.3.8) |
682 |
water |
683 |
water/glycol |
684 |
alkanes |
685 |
oil |
686 |
acids |
687 |
CxHx refined |
688 |
CxHx light |
689 |
alcohols |
690 |
caustic soda |
691 |
refrigerant |
692 |
solvents |
693 |
dead time |
694 |
dead time
(D1.4.4) |
695 |
�s |
696 |
counter decrease |
697 |
counter decrease
(C2.7.2) |
698 |
counter limit |
699 |
counter limit
(C2.7.3) |
700 |
error limit |
701 |
error limit
(C2.7.1) |
702 |
window size |
703 |
window size
(D1.3.2) |
704 |
window weight |
705 |
window weight
(D1.3.3) |
706 |
window minimum |
707 |
window minimum
(D1.3.4) |
708 |
GK |
709 |
GK
(C2.5.2) |
710 |
window start |
711 |
window start
(D1.3.5) |
712 |
window end |
713 |
window end
(D1.3.6) |
714 |
trigger level |
715 |
trigger level
(D1.4.2) |
716 |
trigger margin |
717 |
trigger margin
(D1.4.3) |
718 |
path 1 |
719 |
path 1
(D2.1.1) |
720 |
ps |
721 |
linearization |
722 |
linearization
(C2.5.4) |
723 |
pulse form |
724 |
pulse form
(D1.5) |
725 |
sine |
726 |
double sine |
727 |
tracking |
728 |
tracking
(D1.7) |
729 |
normal |
730 |
fast |
731 |
SNR
(D1.8) |
732 |
raw |
733 |
filtered |
734 |
ping time |
735 |
ping time
(D1.9) |
736 |
DSP set 1 |
737 |
DSP set 1
(D1.10.1) |
738 |
DSP set 2 |
739 |
DSP set 2
(D1.10.2) |
740 |
DSP set 3 |
741 |
DSP set 3
(D1.10.3) |
742 |
number of paths |
743 |
number of paths
(X4) |
744 |
1 path |
745 |
2 paths |
746 |
pipe temperature |
747 |
(X5.14.1, C1.3.13.1) |
748 |
calibration number |
749 |
calibration number
(X7/8, X9.6, C3.6) |
750 |
required |
751 |
completed |
752 |
size |
753 |
size
(X3.1, X5.2.2, X5.5.2, X5.8.2, X6.2.2, X6.5.2, X6.8.2, X7.2, X7.6.2, X8.2, X8.6.2, B2.11.1.2, B2.11.2, B2.11.2.2, C1.3.1.2, C1.3.4.2, C1.3.7.2, C1.4.3.2, C1.4.6.2, C2.3.1.2, C2.3.4.2, C2.3.7.2, C2.4.3.2, C7.7.1) |
754 |
mm |
755 |
inch |
756 |
(X6.11.1, C2.3.10.1) |
757 |
(X6.10.1, X8.5.1, C2.3.9.1) |
758 |
(X6.13.1, C2.3.12.1) |
759 |
(C2.6.4.1) |
760 |
(C2.6.4.2) |
761 |
(C2.6.1.2) |
762 |
(C2.6.1.1) |
763 |
(X6.7.1, C2.3.6.1) |
764 |
numb. traverses 2 |
765 |
numb. traverses 2
(X8, C1.4.5, C2.4.2) |
766 |
(X6.2.1, C2.3.1.1) |
767 |
(X6.4.1, C2.3.3.1) |
768 |
(X6.5.1, C2.3.4.1) |
769 |
time constant |
770 |
time constant
(A4.5) |
771 |
actual distance 2 |
772 |
(X8.1, X8.6.1, B2.11.2.1, C1.4.6.1, C2.4.3.1) |
773 |
transducer set 2 |
774 |
transducer set 2
(X8, C1.4.4, C2.4.1) |
775 |
(X6.8.1, C2.3.7.1) |
776 |
(X6.3, C2.3.2) |
777 |
(X6.6, C2.3.5) |
778 |
(X6.9, C2.3.8) |
779 |
path 2 |
780 |
path 2
(B2.9.2) |
781 |
mode |
782 |
mode
(C4.2.1) |
783 |
min. stacking |
784 |
min. stacking
(D1.6.2) |
785 |
max. stacking |
786 |
max. stacking
(D1.6.3) |
787 |
diagnostics 1 |
788 |
diagnostics 1
(C1.17.1) |
789 |
gain 1 |
790 |
SNR 1 |
791 |
diagnostics 2 |
792 |
diagnostics 2
(C1.17.2, C2.10.1) |
793 |
gain 2 |
794 |
SNR 2 |
795 |
(X6.14.1, C2.3.13.1) |
796 |
volume flow sum |
797 |
volume flow sum
(C2.9) |
798 |
volume flow 1+2 |
799 |
volume flow 1-2 |
800 |
volume flow 2-1 |
801 |
specific heat |
802 |
specific heat
(C1.16) |
803 |
flow mode |
804 |
flow mode
(C1.10) |
805 |
standard |
806 |
heat |
807 |
cold |
808 |
temperature inputs |
809 |
temperature inputs
(C1.11) |
810 |
fixed |
811 |
supply temperature |
812 |
(C1.12.1) |
813 |
return temperature |
814 |
(C1.13.1) |
815 |
current inputs |
816 |
current inputs
(C1.14) |
817 |
A: supply B:return |
818 |
A:return B:supply |
819 |
flow sensor |
820 |
flow sensor
(C1.15) |
821 |
At supply side |
822 |
At return side |
823 |
glycol % vol. |
824 |
glycol % vol.
(X6.12, C2.3.11) |
825 |
number of pipes |
826 |
number of pipes
(X4, C1.1, C2.1) |
827 |
1 pipe |
828 |
2 pipes |
829 |
Ta serial no. |
830 |
Ta serial no.
(X9.1, C3.1) |
831 |
Tb serial no. |
832 |
Tb serial no.
(X9.3, C3.3) |
833 |
Tc serial no. |
834 |
Tc serial no.
(X9.5, C3.5) |
835 |
pulse value unit |
836 |
pulse value unit
(A5.2, A5.3.2, C4.2.5.2, C4.3.5.2, C4.5.5.2) |
837 |
MJ |
838 |
GJ |
839 |
kWh |
840 |
GWh |
841 |
BTU |
842 |
MMBTU |
843 |
free unit |
844 |
[J]*factor |
845 |
[J]*factor
(C7.7.20) |
846 |
Text free unit |
847 |
Text free unit
(C7.7.6) |
848 |
heat
(C5.1.5.2, C5.1.7.2, C5.3.5.2, C5.3.7.2, C7.7.18) |
849 |
[W]*factor |
850 |
[W]*factor
(C7.7.10) |
851 |
heat flow |
852 |
kW |
853 |
MW |
854 |
BTU/h |
855 |
MMBTU/h |
856 |
Output B |
857 |
Output B
(C4.5.2) |
858 |
status off |
859 |
polarity |
860 |
over range |
861 |
range change B |
862 |
same Signal |
863 |
range change C |
864 |
Output A |
865 |
Output A
(C4.5.2) |
866 |
range change A |
867 |
(A4.3.3, C4.2.2.3, C4.2.5.3, C4.2.6.3, C4.3.2.3, C4.3.5.3, C4.3.6.3, C4.4.2.3, C4.4.6.3, C4.5.2.3, C4.5.5.3, C7.3.3.3, C7.4.3.3) |
868 |
dB |
869 |
HART
(C7.8) |
870 |
HART off |
871 |
HART on |
872 |
select range |
873 |
select range
(C7.5.1) |
874 |
manual |
875 |
automatic |
876 |
range |
877 |
(C7.5.2.1) |
878 |
range +/- |
879 |
(C7.5.2.2) |
880 |
time scale |
881 |
time scale
(C7.5.3) |
882 |
format 1.line |
883 |
format 1.line
(C7.4.2/7) |
884 |
#X. |
885 |
#X.X |
886 |
#X.XX |
887 |
#X.XXX |
888 |
#X.XXXX |
889 |
#X.XXXXX |
890 |
#X.XXXXXX |
891 |
#X.XXXXXXX |
892 |
#X.XXXXXXXX |
893 |
range 0% |
894 |
(C4.2.1.1) |
895 |
range 100% |
896 |
(C4.2.1.2) |
897 |
extended range min |
898 |
(C4.2.2.1) |
899 |
extended range max |
900 |
(C4.2.2.2) |
901 |
measurement |
902 |
measurement
(A5.1) |
903 |
temperature |
904 |
current input |
905 |
(B1.4.1, C4.2.7.1) |
906 |
(C4.3.1.1) |
907 |
(C4.3.1.2) |
908 |
(C4.3.2.1) |
909 |
(C4.3.2.2) |
910 |
(B1.5.1, C4.3.7.1) |
911 |
[m³]*factor |
912 |
[m³]*factor
(C7.7.14) |
913 |
[kg]*factor |
914 |
[kg]*factor
(C7.7.17) |
915 |
[m³/s]*factor |
916 |
[m³/s]*factor
(X3.4, C7.7.4) |
917 |
[kg/s]*factor |
918 |
[kg/s]*factor
(C7.7.7) |
919 |
device serial no. |
920 |
device serial no.
(C7.1.3, D4.2) |
921 |
serial no. sensor |
922 |
serial no. sensor
(C1.9.5, D4.3) |
923 |
electronic serial no. |
924 |
electronic serial no.
(C7.1.4) |
925 |
C number |
926 |
C number
(B3.3, C7.1.2) |
927 |
detected C-No. |
928 |
detected C-No.
(D4.1) |
929 |
Proc: Current Input
(C1.17.9) |
930 |
Maintenance Required |
931 |
checks in progress |
932 |
Out Of Specification |
933 |
application error |
934 |
V no. sensor |
935 |
V no. sensor
(C1.9.6, D4.4) |
936 |
limitation max |
937 |
(C4.2.7.2, C4.2.8.2) |
938 |
limitation min |
939 |
(C4.2.7.1, C4.2.8.1) |
940 |
(A4.4.1, C4.2.8.1, C4.2.9.1) |
941 |
LFC hysteresis |
942 |
(A4.4.2, C4.2.8.2, C4.2.9.2) |
943 |
threshold |
944 |
threshold
(C4.3.12) |
945 |
hysteresis |
946 |
(C4.2.12.2) |
947 |
polarity |
948 |
polarity
(C4.5.3/6) |
949 |
both polarities |
950 |
positive polarity |
951 |
negative polarity |
952 |
absolute value |
953 |
special function |
954 |
special function
(C4.3.10/11) |
955 |
automatic range |
956 |
external range |
957 |
error current |
958 |
error current
(C4.3.3) |
959 |
error condition |
960 |
error condition
(C4.3.4) |
961 |
(C4.4.8.2) |
962 |
(C4.4.8.1) |
963 |
(A4.4.1, C4.4.9.1) |
964 |
(A4.4.2, C4.4.9.2) |
965 |
(C4.4.12.2) |
966 |
pulse width |
967 |
pulse width
(C4.5.2) |
968 |
pulse shape |
969 |
pulse shape
(C4.5.1) |
970 |
symmetric |
971 |
100% pulse rate |
972 |
100% pulse rate
(C4.5.3) |
973 |
max. pulse rate |
974 |
max. pulse rate
(C4.5.3) |
975 |
(C4.4.1.2) |
976 |
(C4.4.2.2) |
977 |
(C4.4.1.1) |
978 |
funct. of totalizer |
979 |
funct. of totalizer
(C5.2.1) |
980 |
sum totalizer |
981 |
+ totalizer |
982 |
- totalizer |
983 |
invert signal |
984 |
invert signal
(C4.3.2) |
985 |
(C4.3.7.2, C4.3.8.2) |
986 |
(C4.3.7.1, C4.3.8.1) |
987 |
(C4.3.8.1, C4.3.9.1) |
988 |
(C4.3.8.2, C4.3.9.2) |
989 |
(C4.3.12.2) |
990 |
(C4.5.7.2) |
991 |
(C4.5.7.1) |
992 |
(C4.5.8.1) |
993 |
(C4.5.8.2) |
994 |
phase shift w.r.t. D |
995 |
phase shift w.r.t. B |
996 |
phase shift w.r.t. B
(C4.5.10/11) |
997 |
0° phase shift |
998 |
90° phase shift |
999 |
180° phase shift |
1000 |
pulse output |
1001 |
current output |
1002 |
status output |
1003 |
control input |
1004 |
frequency output |
1005 |
terminals A |
1006 |
terminals A
(C4.1.1) |
1007 |
limit switch |
1008 |
terminals B |
1009 |
terminals B
(C4.1.2) |
1010 |
terminals C |
1011 |
terminals C
(C4.1.3) |
1012 |
terminals D |
1013 |
terminals D
(C4.1.4) |
1014 |
(B1.4.2, B1.5.2, C4.2.7.2, C4.3.7.2) |
1015 |
mA |
1016 |
g |
1017 |
kg |
1018 |
t |
1019 |
oz |
1020 |
lb |
1021 |
ST |
1022 |
LT |
1023 |
ml |
1024 |
L |
1025 |
hl |
1026 |
m³ |
1027 |
in³ |
1028 |
ft³ |
1029 |
yd³ |
1030 |
gal |
1031 |
IG |
1032 |
bbl |
1033 |
density
(X3.6, X5.11.2, X6.11.2, C1.3.10.2, C2.3.10.2, C7.7.21) |
1034 |
kg/m³ |
1035 |
kg/L |
1036 |
lb/cf |
1037 |
lb/gal |
1038 |
volume |
1039 |
volume
(C5.1.5.2, C5.1.7.2, C5.2.5.2, C5.2.7.2, C5.3.5.2, C5.3.7.2, C7.7.12) |
1040 |
mass |
1041 |
mass
(C5.1.5.2, C5.1.7.2, C5.2.5.2, C5.2.7.2, C5.3.5.2, C5.3.7.2, C7.7.15) |
1042 |
velocity |
1043 |
velocity
(X3.5, X5.4.2, X5.7.2, X5.10.2, X6.4.2, X6.7.2, X6.10.2, X7.3.2, X7.5.2, X8.3.2, X8.5.2, A4.2, A4.3.3, B1.3.2, B2.4.2, B2.7.1.2, B2.7.2, B2.7.2.2, C1.3.3.2, C1.3.6.2, C1.3.9.2, C1.6.1.3, C1.6.4.3, C1.8.2.2, C2.3.3.2, C2.3.6.2, C2.3.9.2, C2.6.1.3, C2.6.4.3, C4.2.2.3, C4.2.5.3, C4.2.6.3, C4.3.2.3, C4.3.5.3, C4.3.6.3, C4.4.2.3, C4.4.6.3, C4.5.2.3, C4.5.5.3, C7.3.3.3, C7.4.3.3, C7.7.11) |
1044 |
m/s |
1045 |
ft/s |
1046 |
volume flow |
1047 |
volume flow
(X3.2, X7.2, X8.2, A4.2, A4.3.3, A5.4.3, B1.1.2, B1.2.2, B2.1.2, B2.2.2, C1.8.1.2, C2.8.1.2, C4.2.2.3, C4.2.5.3, C4.2.6.3, C4.2.7.3, C4.3.2.3, C4.3.5.3, C4.3.6.3, C4.3.7.3, C4.4.2.3, C4.4.6.3, C4.5.2.3, C4.5.5.3, C4.5.7.3, C5.1.3.3, C5.2.3.3, C5.3.3.3, C7.3.3.3, C7.4.3.3, C7.7.2) |
1048 |
L/s |
1049 |
L/min |
1050 |
L/h |
1051 |
m³/s |
1052 |
m³/min |
1053 |
m³/h |
1054 |
m³/d |
1055 |
cf/s |
1056 |
cf/min |
1057 |
cf/h |
1058 |
gal/s |
1059 |
gal/min |
1060 |
gal/h |
1061 |
gal/d |
1062 |
IG/s |
1063 |
IG/min |
1064 |
IG/h |
1065 |
IG/d |
1066 |
bbl/h |
1067 |
bbl/d |
1068 |
mass flow |
1069 |
g/s |
1070 |
g/min |
1071 |
g/h |
1072 |
kg/s |
1073 |
kg/min |
1074 |
kg/h |
1075 |
t/min |
1076 |
t/h |
1077 |
t/d |
1078 |
lb/s |
1079 |
lb/min |
1080 |
lb/h |
1081 |
ST/min |
1082 |
ST/h |
1083 |
ST/d |
1084 |
LT/h |
1085 |
LT/d |
1086 |
temperature
(X3.7, X5.14.2, X6.14.2, B1.4.2, B1.5.2, B2.12.2, B2.13.2, C1.3.13.2, C1.12.2, C1.13.2, C2.3.13.2, C4.2.4.3, C4.2.7.2, C4.3.4.3, C4.3.7.2, C7.3.3.3, C7.4.3.3, C7.7.22) |
1087 |
K |
1088 |
°C |
1089 |
°F |
1090 |
(C7.3.4.2) |
1091 |
(C7.3.4.1) |
1092 |
(C7.3.5.1) |
1093 |
(C7.3.5.2) |
1094 |
function |
1095 |
function
(C7.4.1) |
1096 |
one line |
1097 |
two lines |
1098 |
three lines |
1099 |
format 2.line |
1100 |
format 2.line
(C7.4.4/9) |
1101 |
format 3.line |
1102 |
format 3.line
(C7.4.6/11) |
1103 |
(C7.4.4.2) |
1104 |
(C7.4.4.1) |
1105 |
(C7.4.5.1) |
1106 |
(C7.4.5.2) |
1107 |
Empty Pipe 1 |
1108 |
Empty Pipe 2 |
1109 |
Flow Polarity |
1110 |
Flow Polarity 2 |
1111 |
Flow Polarity sum |
1112 |
Power Polarity |
1113 |
Flow Over Range |
1114 |
Flow Over Range Pipe 2 |
1115 |
Totalizer 1 Preset |
1116 |
Totalizer 2 Preset |
1117 |
Totalizer 3 Preset |
1118 |
Output D |
1119 |
Output C |
1120 |
(B1.4, C4.2.14) |
1121 |
(B1.7, C4.5.13) |
1122 |
(B1.5, C4.3.14) |
1123 |
(B1.6, C4.4.14) |
1124 |
(B1.4, C4.2.13) |
1125 |
(B1.5, C4.3.13) |
1126 |
default display |
1127 |
default display
(C7.2.3) |
1128 |
status page |
1129 |
Optical Keys |
1130 |
Optical Keys
(C7.2.4) |
1131 |
hold all outputs |
1132 |
hold output A |
1133 |
hold output C |
1134 |
hold output D |
1135 |
all outputs to zero |
1136 |
output A to zero |
1137 |
output C to zero |
1138 |
output D to zero |
1139 |
reset all totalizers |
1140 |
reset totalizer 1 |
1141 |
reset totalizer 2 |
1142 |
stop all totalizers |
1143 |
stop totalizer 1 |
1144 |
stop totalizer 2 |
1145 |
zero outp.+stop total. |
1146 |
error reset |
1147 |
hold output B |
1148 |
output B to zero |
1149 |
IO2 |
1150 |
Display IO |
1151 |
Profibus |
1152 |
FF |
1153 |
Basic IO |
1154 |
Mod./Exi IO |
1155 |
Profi.DP |
1156 |
Profi.PA |
1157 |
Foundation H1 |
1158 |
Modbus |
1159 |
velocity of sound |
1160 |
flow speed |
1161 |
gain |
1162 |
cold flow |
1163 |
volume flow 2 |
1164 |
diag. gain 1 |
1165 |
diag. SNR 1 |
1166 |
diag. gain 2 |
1167 |
diag. SNR 2 |
1168 |
range min |
1169 |
range max |
1170 |
threshold |
1171 |
value p. pulse |
1172 |
preset value |
1173 |
measurement 1.line |
1174 |
measurement 1.line
(C7.4.2) |
1175 |
temperature A |
1176 |
temperature B |
1177 |
measurement 2.line |
1178 |
measurement 2.line
(C7.4.8) |
1179 |
Totaliser 1 Volume |
1180 |
Totaliser 1 Mass |
1181 |
Totaliser 1 Energy |
1182 |
Totaliser 1 Volume 2 |
1183 |
Totaliser 2 Volume |
1184 |
Totaliser 2 Mass |
1185 |
Totaliser 2 Volume 2 |
1186 |
Tot. 2 Volume sum |
1187 |
Totaliser 3 Volume |
1188 |
Totaliser 3 Mass |
1189 |
Totaliser 3 Energy |
1190 |
Tot. 3 Volume sum |
1191 |
operating hours |
1192 |
bargraph |
1193 |
measurement 3.line |
1194 |
measurement 3.line
(C7.4.10) |
1195 |
HART dynamic var. |
1196 |
HART dynamic var.
(C6.4.1) |
1197 |
(X5.13.2, X6.13.2, C1.3.12.2, C2.3.12.2) |
1198 |
cP |
1199 |
(C4.2.4.2) |
1200 |
(C4.2.4.1) |
1201 |
(C4.3.4.2) |
1202 |
(C4.3.4.1) |
1203 |
VoS fluid
(X6.10, X8.5, C2.3.9) |
1204 |
VoS liner material
(X6.7, C2.3.6) |
1205 |
VoS pipe material
(X6.4, C2.3.3) |
1206 |
pipe temperature
(X6.14, C2.3.13) |
1207 |
diameter
(X6.2, C2.3.1) |
1208 |
wall thickness
(X6.5, C2.3.4) |
1209 |
density
(X6.11, C2.3.10) |
1210 |
dynamic viscosity
(X6.13, C2.3.12) |
1211 |
liner thickness
(X6.8, C2.3.7) |
1212 |
actual distance |
1213 |
actual distance
(X8, C1.4.6, C2.4.3) |
1214 |
limitation |
1215 |
limitation
(C7.4.4) |
1216 |
low flow cutoff |
1217 |
low flow cutoff
(A5.4) |
1218 |
supply temperature
(C1.12) |
1219 |
return temperature
(C1.13) |
1220 |
range
(A4.3) |
1221 |
value p. pulse
(A5.3) |
1222 |
threshold
(C4.2.2) |
1223 |
preset value
(C5.3.4) |
1224 |
range 0%...100% |
1225 |
range 0%...100%
(C4.2.1) |
1226 |
extended range |
1227 |
extended range
(C4.3.2) |
1228 |
(B1.4, C4.2.7) |
1229 |
(B1.5, C4.3.7) |
1230 |
language |
1231 |
language
(X1, A1, C7.2.1) |
1232 |
English |
1233 |
Deutsch |
1234 |
Français |
1235 |
Nederlands |
1236 |
Align HART Units |
1237 |
Align 'HART units' (for measured values) to 'display units' (for configuration parameters) or to default.
(Fct. C6.5) |
1238 |
J/gK |
1239 |
unit % |
1240 |
Auxiliary variable |
1241 |
unit Hz |
1242 |
unit mA |
1243 |
unit s |
1244 |
unit h |
1245 |
Sensor CPU |
1246 |
Sensor CPU
(B3.4.1, C1.9.1) |
1247 |
Sensor DSP |
1248 |
Sensor DSP
(B3.4.2, C1.9.2) |
1249 |
information
(C1.9) |
1250 |
RS485/Modbus |
1251 |
RS485/Modbus
(C7.8) |
1252 |
Foundation Fieldb |
1253 |
Foundation Fieldb
(C7.8) |
1254 |
SW.REV. MS |
1255 |
SW.REV. MS
(B3.5, C4.3.3/4/6, C4.4.4/6, C4.5.4/6/11/12, C5.1.10, C5.2.10, C7.1.5) |
1256 |
SW.REV. UIS |
1257 |
SW.REV. UIS
(B3.6) |
1258 |
Electronic Revision |
1259 |
Electronic Revision
(B3.8, C7.1.6) |
1260 |
calibration date |
1261 |
calibration date
(C1.9.4) |
1262 |
Sensor Driver |
1263 |
Sensor Driver
(B3.4.3, C1.9.3) |
1264 |
Profibus
(B3.7, C5.1.7, C5.2.7, C5.3.7, C7.8.7) |
1265 |
Custody transfer |
1266 |
Access Level HART |
1267 |
Authorization level for data access via the HART interface. |
1268 |
Standard (1) |
1269 |
Extended (2) |
1270 |
Service (3) |
1271 |
Password |
1272 |
Password for changing the authorization level for data access via the HART interface. |
1273 |
4u |
1274 |
Custody Lock |
1275 |
If Custody Lock is activated, all configuration parameters are write protected. |
1276 |
on |
1277 |
operating hours
(B2.16) |
1278 |
uiCNumberDetectedDigit01 |
1279 |
uiCNumberDetectedDigit02 |
1280 |
uiCNumberDetectedDigit03 |
1281 |
uiCNumberDetectedDigit04 |
1282 |
uiCNumberDetectedDigit05 |
1283 |
uiCNumberDetectedDigit06 |
1284 |
uiCNumberDetectedDigit07 |
1285 |
C-Number (8th Position) |
1286 |
8th position of the C-number |
1287 |
0 |
1288 |
1 |
1289 |
2 |
1290 |
3 |
1291 |
4 |
1292 |
5 |
1293 |
6 |
1294 |
7 |
1295 |
8 |
1296 |
9 |
1297 |
A |
1298 |
B |
1299 |
C |
1300 |
D |
1301 |
E |
1302 |
F |
1303 |
uiCNumberDetectedDigit09 |
1304 |
uiCNumberDetectedDigit10 |
1305 |
Circuit Board Info |
1306 |
Displays circuit board information. I.e. Identnumber, Hardware ID, Software Version, Production Date, Calibration Date, Board Serial Number. |
1307 |
reset errors |
1308 |
reset errors
(A3.1, C7.6.1) |
1309 |
Warmstart |
1310 |
Perform a "warm start". |
1311 |
Enable Service Access |
1312 |
Enabling service parameter access via HART for 20 min.
I.e. Setting the authorization level to Service (3). |
1313 |
Disable Service Access |
1314 |
Disabling service parameter access via HART.
I.e. Resetting the authorization level to Standard (1). |
1315 |
Simulation current input A |
1316 |
Simulation current input B |
1317 |
Simulation frequency output B |
1318 |
Simulation frequency output A |
1319 |
Simulation frequency output D |
1320 |
Simulation current output B |
1321 |
Simulation current output C |
1322 |
Simulation current output A |
1323 |
Simulation control input B |
1324 |
Simulation control input A |
1325 |
Simulation status output D |
1326 |
Simulation status output B |
1327 |
Simulation status output C |
1328 |
Simulation status output A |
1329 |
Simulation limit switch D |
1330 |
Simulation limit switch C |
1331 |
Simulation limit switch B |
1332 |
Simulation limit switch A |
1333 |
Simulation pulse output D |
1334 |
Simulation pulse output A |
1335 |
Simulation pulse output B |
1336 |
act. vel. of sound path 1 |
1337 |
act. vel. of sound path 1
(X.X) |
1338 |
act. vel. of sound path 2 |
1339 |
act. vel. of sound path 2
(X.X) |
1340 |
act. flow speed |
1341 |
act. flow speed
(B2.4) |
1342 |
act. mass flow |
1343 |
act. mass flow
(B2.3) |
1344 |
act. Reynolds no. 1 |
1345 |
act. Reynolds no. 1
(B2.5) |
1346 |
act. SNR path 2 |
1347 |
act. SNR path 2
(X.X) |
1348 |
act. volume flow |
1349 |
act. volume flow
(B2.1) |
1350 |
act. volume flow 2 |
1351 |
act. volume flow 2
(B2.2) |
1352 |
current in A
(C4.2) |
1353 |
current in B
(C4.3) |
1354 |
act. signal quality path 2 |
1355 |
act. signal quality path 2
(X.X) |
1356 |
act. signal quality path 1 |
1357 |
act. signal quality path 1
(X.X) |
1358 |
act. temperature B |
1359 |
act. temperature B
(B2.13) |
1360 |
act. temperature A |
1361 |
act. temperature A
(B2.12) |
1362 |
act. SNR path 1 |
1363 |
act. SNR path 1
(X.X) |
1364 |
act. gain path 2 |
1365 |
act. gain path 2
(X.X) |
1366 |
act. gain path 1 |
1367 |
act. gain path 1
(X.X) |
1368 |
act. Reynolds no. 2 |
1369 |
act. Reynolds no. 2
(B2.6) |
1370 |
opt. transd. distance path 1 |
1371 |
opt. transd. distance path 1
(X.X) |
1372 |
opt. transd. distance path 2 |
1373 |
opt. transd. distance path 2
(X.X) |
1374 |
velocity of sound
(B1.3, C1.8.2) |
1375 |
volume flow
(B1.1, C1.8.1) |
1376 |
volume flow 2
(B1.2, C2.8.1) |
1377 |
zero calibration |
1378 |
zero calibration
(C2.5.1) |
1379 |
set pipe material |
1380 |
set liner material |
1381 |
set fluid |
1382 |
FDI Health Status |
1383 |
Indeterminate |
1384 |
Good |
1385 |
FDI Health Status |
1386 |
Displays the 'Health Status' according to FDI standard. |
1387 |
GetHealthStatus |
1388 |
Status Bit Not Supported |
1389 |
No Effect |
1390 |
disabled |
1391 |
enabled |
1392 |
Reset |
1393 |
Set |
1394 |
Used to map a status condition to a severity level. |
1395 |
PV Analog Channel Saturated |
1396 |
PV Analog Channel Fixed |
1397 |
Critical Power Failure |
1398 |
Failure |
1399 |
Out of Specification |
1400 |
Function Check |
1401 |
Simulation active |
1402 |
Non-Volatile memory failure |
1403 |
Volatile memory error |
1404 |
Watchdog reset executed |
1405 |
Power supply conditions out of range |
1406 |
Environmental conditions out of range |
1407 |
Electronic failure |
1408 |
Device configuration locked |
1409 |
Status simulation active |
1410 |
Discrete Variable Simulation active |
1411 |
Event Notification Overflow |
1412 |
Secondary Analog Channel Saturated |
1413 |
Tertiary Analog Channel Saturated |
1414 |
Quaternary Analog Channel Saturated |
1415 |
Quinary Analog Channel Saturated |
1416 |
Subdevice list changed |
1417 |
Duplicate master detected |
1418 |
Sub-device mismatch |
1419 |
Sub-devices with duplicate IDs found |
1420 |
Stale data notice |
1421 |
Capacity Denied |
1422 |
Bandwidth allocation pending |
1423 |
Block transfer pending |
1424 |
Radio failure |
1425 |
Secondary Analog Channel Fixed |
1426 |
Tertiary Analog Channel Fixed |
1427 |
Quaternary Analog Channel Fixed |
1428 |
Quinary Analog Channel Fixed |
1429 |
Condensed status simulation |
1430 |
Allows simulation of different status conditions. |
1431 |
Condensed status value |
1432 |
Starting Status Map Index must be even value. |
1433 |
Bit Index |
1434 |
Reset Condensed Status Map |
1435 |
Show single events |
1436 |
On occurence |
1437 |
Always |
1438 |
Never |
1439 |
Optical Interf. Active |
1440 |
Disp. 2 Overrange |
1441 |
Status Out C Active |
1442 |
Status Out B Active |
1443 |
Status Out A Active |
1444 |
Control In B Active |
1445 |
Control In A Active |
1446 |
Tot 3 FB5 Threshold |
1447 |
Tot 2 FB4 Threshold |
1448 |
Tot 1 FB3 Threshold |
1449 |
Disp. 1 Overrange |
1450 |
Tot 3 Stopped |
1451 |
Tot 2 Stopped |
1452 |
Tot 1 Stopped |
1453 |
PROFIBUS Freeze Mode |
1454 |
PROFIBUS Sync Mode |
1455 |
PROFIBUS Clear Data |
1456 |
PROFIBUS Passivated |
1457 |
PROFIBUS Baudrate |
1458 |
PROFIBUS No Data |
1459 |
Sensor Starting up |
1460 |
Zero Calibr. Running |
1461 |
Zero Cal. running pipe 2 |
1462 |
RB is set to OOS |
1463 |
Fieldbus No Connection |
1464 |
Status Out D Active |
1465 |
Disp. 2 no measure values |
1466 |
Disp. 1 no measure values |
1467 |
Tot 2 No Meas. Values |
1468 |
Tot 1 No Meas. Values |
1469 |
IO D No Meas. Values |
1470 |
IO C No Meas. Values |
1471 |
IO B No Meas. Values |
1472 |
IO A No Meas. Values |
1473 |
Power Failure Detected |
1474 |
Tot 3 FB5 Power Failure |
1475 |
Tot 2 FB4 Power Failure |
1476 |
Tot 2 Power Failure |
1477 |
Tot 1 FB3 Power Failure |
1478 |
Tot 1 Power Failure |
1479 |
Tot 2 Overflow |
1480 |
Tot 3 FB5 Overflow |
1481 |
Tot 1 Overflow |
1482 |
Tot 2 FB4 Overflow |
1483 |
Tot 1 FB3 Overflow |
1484 |
Unreliable pipe 2 |
1485 |
Time of Flight |
1486 |
Unreliable pipe 1, path 2 |
1487 |
Unreliable pipe 1, path 1 |
1488 |
Signal lost pipe 2 |
1489 |
Signal lost pipe 1, path 2 |
1490 |
Signal lost pipe 1, path 1 |
1491 |
IO C Open Conn. |
1492 |
IO B Connection |
1493 |
IO A Connection |
1494 |
IO B Error Current |
1495 |
IO A Error Current |
1496 |
Backup 2 Data Faulty |
1497 |
Backup 1 Data Faulty |
1498 |
Backplane Difference |
1499 |
Mem. Life Exceeded |
1500 |
Factory Data Faulty |
1501 |
Backplane Data Faulty |
1502 |
Crossed Cabling |
1503 |
Vel Out of Range pipe 2 |
1504 |
Velocity Out of Range |
1505 |
IO D Overrange |
1506 |
IO C Overrange |
1507 |
IO B Overrange |
1508 |
VoS Difference |
1509 |
IO A Overrange |
1510 |
Electr.Temp.Out of Spec |
1511 |
Conv. Zero too large |
1512 |
IO D Simulation Active |
1513 |
IO A Simulation Active |
1514 |
Tot 3 FB5 Man. Active |
1515 |
Tot 2 FB4 Man. Active |
1516 |
Tot 1 FB3 Man. Active |
1517 |
Tot 3 FB5 Sim. Active |
1518 |
Tot 2 FB4 Sim. Active |
1519 |
Tot 1 FB3 Sim. Active |
1520 |
PROFIBUS Sim/Man Active |
1521 |
Fieldbus Sim. Active |
1522 |
Flow simulation pipe 2 |
1523 |
VoS Simulation pipe 2 on |
1524 |
IO C Simulation Active |
1525 |
VoS Simulation Active |
1526 |
Flow Simulation Active |
1527 |
IO B Simulation Active |
1528 |
IO D Configuration |
1529 |
IO C Configuration |
1530 |
IO2 Configuration |
1531 |
IO1 Configuration |
1532 |
Display Config. |
1533 |
Modbus Config. |
1534 |
Tot 3 FB5 Unit Error |
1535 |
Tot 2 FB4 Unit Error |
1536 |
Tot 1 FB3 Unit Error |
1537 |
IO B Configuration |
1538 |
PROFIBUS Config. |
1539 |
Fieldbus Config. |
1540 |
Process Input Config. |
1541 |
DM Configuration |
1542 |
BM Configuration |
1543 |
IO A Configuration |
1544 |
Tot 2 Configuration |
1545 |
Tot 1 Configuration |
1546 |
IO C Failure |
1547 |
IO B Failure |
1548 |
Modbus Failure |
1549 |
PROFIBUS Failure |
1550 |
Fieldbus Failure |
1551 |
Sensor Driver Failure |
1552 |
DSP Failure |
1553 |
IO A Failure |
1554 |
uProc. Failure |
1555 |
FrontEnd Failure |
1556 |
DM Failure |
1557 |
BM Failure |
1558 |
HW Combination Error |
1559 |
System Error C |
1560 |
Tot 3 Failure |
1561 |
System Error A |
1562 |
System Error |
1563 |
Tot 2 Failure |
1564 |
Tot 1 Failure |
1565 |
IO 2 Failure |
1566 |
IO 1 Failure |
1567 |
Reset to default |
1568 |
Reset the mappings to the Condensed Status to default values. |
1569 |
Set Simulation Bits |
1570 |
(De)activates the selected Simulation bits |
1571 |
Enable/disable Status Simulation |
1572 |
Enable/disable status simulation. |
1573 |
set totalizer |
1574 |
set totalizer
(C5.3.7) |
1575 |
start totalizer |
1576 |
start totalizer
(C5.3.9) |
1577 |
stop totalizer |
1578 |
stop totalizer
(C5.3.8) |
1579 |
reset totalizer 3 |
1580 |
units |
1581 |
No Unit |
1582 |
Unit classification |
1583 |
Unit Temperature |
1584 |
Unit for Temperature. |
1585 |
ui16ObjectNumberGdcDelayed |
1586 |
ui16ObjectNumberGdcGeneric |
1587 |
uiSubNumberGdcDelayed |
1588 |
uiSubNumberGdcGeneric |
1589 |
flResponseTimeGdcDelayed |
1590 |
uniPlaceholderGdc |
1591 |
uiCountBytesGdcTg |
1592 |
uiSubNumberGdcTg |
1593 |
ui16ObjectNumberGdcTg |
1594 |
uiControlStatusGdcTg |
1595 |
GDC timeout |
1596 |
GDC error |
1597 |
GDC delayed response |
1598 |
C number undefined |
1599 |
Waiting for GDC delayed response |
1600 |
uiGdcDelayed1 |
1601 |
uiGdcDelayed2 |
1602 |
uiGdcDelayed3 |
1603 |
uiGdcDelayed4 |
1604 |
uiGdcDelayed5 |
1605 |
uiGdcDelayed6 |
1606 |
uiGdcDelayed7 |
1607 |
uiGdcDelayed8 |
1608 |
uiGdcDelayed9 |
1609 |
uiGdcDelayed10 |
1610 |
uiGdcDelayed11 |
1611 |
uiGdcDelayed12 |
1612 |
uiGdcDelayed13 |
1613 |
uiGdcDelayed14 |
1614 |
uiGdcDelayed15 |
1615 |
uiGdcDelayed16 |
1616 |
uiGdcDelayed17 |
1617 |
uiGdcDelayed18 |
1618 |
uiGdcDelayed19 |
1619 |
uiGdcDelayed20 |
1620 |
ui16GdcDelayedWord1 |
1621 |
ui16GdcDelayedWord2 |
1622 |
ui16GdcDelayedWord3 |
1623 |
ui16GdcDelayedWord4 |
1624 |
ui16GdcDelayedWord5 |
1625 |
ui16GdcDelayedWord6 |
1626 |
ui16GdcDelayedWord7 |
1627 |
ui16GdcDelayedWord8 |
1628 |
ui16GdcDelayedWord9 |
1629 |
ui16GdcDelayedWord10 |
1630 |
flGdcDelayed1 |
1631 |
flGdcDelayed2 |
1632 |
flGdcDelayed3 |
1633 |
flGdcDelayed4 |
1634 |
flGdcDelayed5 |
1635 |
uiGdcByteGenericRead1 |
1636 |
uiGdcByteGenericRead2 |
1637 |
uiGdcByteGenericRead3 |
1638 |
uiGdcByteGenericRead4 |
1639 |
uiGdcByteGenericRead5 |
1640 |
uiGdcByteGenericRead6 |
1641 |
uiGdcByteGenericRead7 |
1642 |
uiGdcByteGenericRead8 |
1643 |
uiGdcByteGenericRead9 |
1644 |
uiGdcByteGenericRead10 |
1645 |
uiGdcByteGenericRead11 |
1646 |
uiGdcByteGenericRead12 |
1647 |
uiGdcByteGenericRead13 |
1648 |
uiGdcByteGenericRead14 |
1649 |
uiGdcByteGenericRead15 |
1650 |
uiGdcByteGenericRead16 |
1651 |
uiGdcByteGenericRead17 |
1652 |
uiGdcByteGenericRead18 |
1653 |
uiGdcByteGenericRead19 |
1654 |
uiGdcByteGenericRead20 |
1655 |
uiGdcByteGenericRead21 |
1656 |
uiGdcByteGenericRead22 |
1657 |
uiGdcByteGenericRead23 |
1658 |
uiGdcByteGenericRead24 |
1659 |
uiGdcByteGenericRead25 |
1660 |
uiGdcByteGenericRead26 |
1661 |
uiGdcByteGenericRead27 |
1662 |
uiGdcByteGenericRead28 |
1663 |
uiGdcByteGenericRead29 |
1664 |
uiGdcByteGenericRead30 |
1665 |
uiGdcByteGenericWrite1 |
1666 |
uiGdcByteGenericWrite2 |
1667 |
uiGdcByteGenericWrite3 |
1668 |
uiGdcByteGenericWrite4 |
1669 |
uiGdcByteGenericWrite5 |
1670 |
uiGdcByteGenericWrite6 |
1671 |
uiGdcByteGenericWrite7 |
1672 |
uiGdcByteGenericWrite8 |
1673 |
uiGdcByteGenericWrite9 |
1674 |
uiGdcByteGenericWrite10 |
1675 |
uiGdcByteGenericWrite11 |
1676 |
uiGdcByteGenericWrite12 |
1677 |
uiGdcByteGenericWrite13 |
1678 |
uiGdcByteGenericWrite14 |
1679 |
uiGdcByteGenericWrite15 |
1680 |
uiGdcByteGenericWrite16 |
1681 |
uiGdcByteGenericWrite17 |
1682 |
uiGdcByteGenericWrite18 |
1683 |
uiGdcByteGenericWrite19 |
1684 |
uiGdcByteGenericWrite20 |
1685 |
uiGdcByteGenericWrite21 |
1686 |
uiGdcByteGenericWrite22 |
1687 |
uiGdcByteGenericWrite23 |
1688 |
uiGdcByteGenericWrite24 |
1689 |
uiGdcByteGenericWrite25 |
1690 |
uiGdcByteGenericWrite26 |
1691 |
uiGdcByteGenericWrite27 |
1692 |
uiGdcByteGenericWrite28 |
1693 |
uiGdcByteGenericWrite29 |
1694 |
uiGdcByteGenericWrite30 |
1695 |
ui16GdcWordGenericRead1 |
1696 |
ui16GdcWordGenericRead2 |
1697 |
ui16GdcWordGenericRead3 |
1698 |
ui16GdcWordGenericRead4 |
1699 |
ui16GdcWordGenericRead5 |
1700 |
ui16GdcWordGenericRead6 |
1701 |
ui16GdcWordGenericRead7 |
1702 |
ui16GdcWordGenericRead8 |
1703 |
ui16GdcWordGenericRead9 |
1704 |
ui16GdcWordGenericRead10 |
1705 |
ui16GdcWordGenericWrite1 |
1706 |
ui16GdcWordGenericWrite2 |
1707 |
ui16GdcWordGenericWrite3 |
1708 |
ui16GdcWordGenericWrite4 |
1709 |
ui16GdcWordGenericWrite5 |
1710 |
ui16GdcWordGenericWrite6 |
1711 |
ui16GdcWordGenericWrite7 |
1712 |
ui16GdcWordGenericWrite8 |
1713 |
ui16GdcWordGenericWrite9 |
1714 |
flGdcFloatGenericRead1 |
1715 |
flGdcFloatGenericRead2 |
1716 |
flGdcFloatGenericRead3 |
1717 |
flGdcFloatGenericRead4 |
1718 |
flGdcFloatGenericRead5 |
1719 |
flGdcFloatGenericWrite1 |
1720 |
flGdcFloatGenericWrite2 |
1721 |
flGdcFloatGenericWrite3 |
1722 |
flGdcFloatGenericWrite4 |
1723 |
ui32GdcUlongGenericRead1 |
1724 |
ui32GdcUlongGenericRead2 |
1725 |
ui32GdcUlongGenericRead3 |
1726 |
ui32GdcUlongGenericRead4 |
1727 |
ui32GdcUlongGenericRead5 |
1728 |
ui32GdcUlongGenericWrite1 |
1729 |
ui32GdcUlongGenericWrite2 |
1730 |
ui32GdcUlongGenericWrite3 |
1731 |
ui32GdcUlongGenericWrite4 |
1732 |
Data type |
1733 |
Byte |
1734 |
Word |
1735 |
Float |
1736 |
Unsigned Long |
1737 |
Invalid object number |
1738 |
Invalid password |
1739 |
Select module |
1740 |
Current output A |
1741 |
Current output B |
1742 |
Current output C |
1743 |
IO 2 |
1744 |
Ident no. |
1745 |
Hardware id |
1746 |
Software version |
1747 |
Production date |
1748 |
Calibration date |
1749 |
Board ser.no. |
1750 |
Show parameters |
1751 |
Select: Show always all parameters or only those actually valid.
For debugging purposes only. |
1752 |
only valid |
1753 |
all |
1754 |
Prepare Parameter Download |
1755 |
Must be performed prior to a complete parameter download to the device.
Writes some basic parameters to the device and performs a warm start. |
1756 |
finish parameter download |
1757 |
Should be performed after a complete parameter download to the device.
Performs a warm start. |
1758 |
Upload Variables |
1759 |
Download Variables |
1760 |
Common Tables |
1761 |
Interoperable * |
1762 |
Universal |
1763 |
Common Practice |
1764 |
Pressure Universal |
1765 |
Pressure Common |
1766 |
Menu |
1767 |
Rosemount Magflow |
1768 |
Rosemount Pressure |
1769 |
Moore Products |
1770 |
Siemens Pressure |
1771 |
P2 Common |
1772 |
Wireless |
1773 |
Munge |
1774 |
Analytical Oxygen/Combustion/Methane/CO |
1775 |
Flow Totalizer - Rate Indicator |
1776 |
Flow Variable Area |
1777 |
Flow Coriolis Mass |
1778 |
Flow Ultrasonic - Gas |
1779 |
Flow Ultrasonic - Liquid |
1780 |
Level Ultrasonic |
1781 |
Level Radar - Microwave |
1782 |
Pressure Absolute |
1783 |
Level Capacitance |
1784 |
Pressure Differential |
1785 |
Level Hydrostatic |
1786 |
Level |
1787 |
Pressure Absolute/Relative |
1788 |
Level Microwave |
1789 |
Level Radar |
1790 |
Level Density - Nuclear |
1791 |
Flow Electromagnetic |
1792 |
Flow Vortex |
1793 |
Flow Magmeter - Rack Version |
1794 |
Flow High Performance Magmeter |
1795 |
Flow Mass |
1796 |
Flow Ultrasonic |
1797 |
Flow Magnetic |
1798 |
Flow Magnetic - Custody Transfer |
1799 |
Flow 2-wire Magnetic |
1800 |
Flow Coriolis Mass - Custody Transfer |
1801 |
Flow 2-wire Vortex |
1802 |
Flow Thermal |
1803 |
Temperature Head Mounted |
1804 |
Temperature Compact |
1805 |
Temperature DIN Rail Mounted |
1806 |
Analytical pH |
1807 |
Analytical Conductivity - Conductive |
1808 |
Analytical Conductivity - Inductive |
1809 |
Temperature Sensor |
1810 |
Level Servo |
1811 |
Temperature DIN Rail |
1812 |
Temperature |
1813 |
Analytical ORP |
1814 |
Analytical pION |
1815 |
Analytical IConc |
1816 |
Analytical Electrode Conductivity |
1817 |
Analytical Toroidal Conductivity |
1818 |
Valve Positioner |
1819 |
Valve Controller |
1820 |
Pressure |
1821 |
Pressure Multivariable |
1822 |
Analytical pH/ORP |
1823 |
Flow Coriolis |
1824 |
Analytical Conductivity |
1825 |
Valve Positioner/Pneumatic |
1826 |
Valve Actuator - Electrical |
1827 |
Temperature Dual Input |
1828 |
Valve Actuator |
1829 |
Analytical Corrosion |
1830 |
Analytical Density - Nuclear |
1831 |
Level Continuous Gamma |
1832 |
Level Laser Ranging |
1833 |
Pressure Safety |
1834 |
Flow Vortex/Swirl |
1835 |
Flow |
1836 |
Analytical 4 Electrode Conductivity |
1837 |
Analytical 2 Electrode Conductivity |
1838 |
Analytical Troidal Conductivity |
1839 |
Analytical pH/ORP/pIon/Ion Conc |
1840 |
Analytical Oxygen |
1841 |
Pressure P, dP + Multivariable |
1842 |
Temperature 2-wire |
1843 |
Pressure w/ PID |
1844 |
Pressure Saturated Steam |
1845 |
Analytical Density - Gamma Ray |
1846 |
Level Gamma Ray |
1847 |
Analytical Weight - Gamma Ray |
1848 |
Level w/ Density - Gamma Ray |
1849 |
Analytical Motorized Density |
1850 |
Flow Multivariable Mass |
1851 |
Temperature Multivariable |
1852 |
Specialty HART-to-Analog Signal Conv |
1853 |
Flow dP |
1854 |
Pressure Low Power |
1855 |
Pressure Certified SIL2 |
1856 |
Interoperable |
1857 |
Analytical Density |
1858 |
Valve Positioner/Electropneumatic |
1859 |
Flow Magnetic Inductive |
1860 |
Analytical |
1861 |
Analytical Opacity Monitor |
1862 |
Analytical Oxygen/Combustion |
1863 |
Analytical 2-wire Conductivity |
1864 |
Analytical 2-wire Conductivity w/ pure H20 |
1865 |
Analytical 2-wire Conductivity w/ % conc |
1866 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
1867 |
Analytical 2-wire pH/ORP |
1868 |
Analytical 2-wire Contacting/Toroidal |
1869 |
Analytical Oxygen - High Temperature |
1870 |
Analytical Conductivity w/ % conc |
1871 |
Analytical pH/ORP/ISE |
1872 |
Analytical Amperometric Analyzer |
1873 |
Analytical Dual Input Analyzer |
1874 |
Pressure Pressure/Level |
1875 |
Analytical Consistency |
1876 |
Analytical Microwave-Pulp Consistency |
1877 |
Analytical Microwave Consistency |
1878 |
Valve Digital Positioner |
1879 |
Valve Smart Valve Positioner |
1880 |
Temperature Differential |
1881 |
Analytical Dissolved Oxygen |
1882 |
Analytical pH Controller |
1883 |
Analytical Conductivity/Resistivity Controller |
1884 |
Analytical Conductivity/Resistivity |
1885 |
Level Displacement |
1886 |
Temperature w/ PID |
1887 |
Valve Universal Positioner |
1888 |
Level Radar - Reflex |
1889 |
Pressure Gauge |
1890 |
Pressure Sealed Gauge |
1891 |
Valve Digital Positioner w/ PID |
1892 |
Valve Intelligent Positioner |
1893 |
Analytical Gas Detector |
1894 |
Analytical Infrared Gas Detector |
1895 |
Analytical Electrochemical Gas Detector |
1896 |
Analytical Measuring Instruments |
1897 |
Level Magnostrictive |
1898 |
Valve On/Off Valve Controller |
1899 |
Level Radar - Pulse |
1900 |
Level Continuous Capactive |
1901 |
Valve Damper Actuator |
1902 |
Valve Electric Damper Actuator |
1903 |
Flow Electronic |
1904 |
Flow Vortex - Multiparameter Mass |
1905 |
Analytical UV Flame Detector |
1906 |
Analytical UVIR Flame Detector |
1907 |
Analytical IR Flame Detector |
1908 |
Analytical Fire Detector |
1909 |
Analytical Gas Detector Display Interface |
1910 |
Analytical Toxic Gas Detector |
1911 |
Analytical Flame Detector |
1912 |
Level Nuclear |
1913 |
Analytical Microwave |
1914 |
Analytical Density - Radiometric |
1915 |
Level Radiometric |
1916 |
Analytical Gas/Steam |
1917 |
Level Nucleonic |
1918 |
Analytical Blade Consistency |
1919 |
Analytical Rotary Consistency |
1920 |
Pressure Absolute/Differential |
1921 |
Positioner |
1922 |
Analytical Combustible Gas Detector |
1923 |
Analytical Point Infrared Gas Detector |
1924 |
Analytical Multi-Detector Monitor System |
1925 |
Valve Positioner/Electro-hydraulic |
1926 |
Valve Monitor |
1927 |
Enable on token-passing data link layer only |
1928 |
Enable on TDMA data link layer only |
1929 |
Enable on both TDMA and token-passing data link layer |
1930 |
WirelessHART Device |
1931 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
1932 |
Primary |
1933 |
Primary Analog Channel |
1934 |
Secondary |
1935 |
Secondary Analog Channel |
1936 |
Tertiary |
1937 |
Tertiary Analog Channel |
1938 |
Quaternary |
1939 |
Quaternary Analog Channel |
1940 |
Quinary |
1941 |
Quinary Analog Channel |
1942 |
Lock all |
1943 |
Trim not supported |
1944 |
Configuration cannot be changed |
1945 |
Locked by gateway |
1946 |
Analog Output Channel |
1947 |
The device is in simulation mode and the level output is not representative of the process. |
1948 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
1949 |
The RAM memory check is invalid or maybe corrupt |
1950 |
A watchdog reset has been performed |
1951 |
Voltage conditions out of range |
1952 |
A voltage condition is outside its allowable range |
1953 |
An internal or environmental condition is beyond acceptable limits. |
1954 |
A hardware problem not related to the sensor has been detected. |
1955 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
1956 |
Continuous |
1957 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
1958 |
Window |
1959 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
1960 |
Rising |
1961 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
1962 |
Falling |
1963 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
1964 |
On-change |
1965 |
The Burst Message is triggered when any value in the message changes. |
1966 |
Battery life |
1967 |
Percent range |
1968 |
Loop current |
1969 |
Primary variable |
1970 |
Secondary variable |
1971 |
Tertiary variable |
1972 |
Quaternary variable |
1973 |
Off |
1974 |
Enable event notification on token-passing data link layer |
1975 |
Enable event notification on TDMA data link layer |
1976 |
Enable event notification on TDMA and token-passing data link layer |
1977 |
Configuration changed event pending |
1978 |
Device status event pending |
1979 |
More status available event pending |
1980 |
Disable |
1981 |
Enable single data point trending |
1982 |
Enable filtered trending |
1983 |
The sample is filtered using a time constant equal to one-third the trend sample period |
1984 |
Enable average trending |
1985 |
The value obtained by dividing the sum of all samples in the period by the total number of samples |
1986 |
Read receive time |
1987 |
Write date and time |
1988 |
Non-Volatile Clock |
1989 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
1990 |
Clock Uninitialized |
1991 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
1992 |
Line Power |
1993 |
Device is powered via a hardwired connection to a plant power source. |
1994 |
Battery Power |
1995 |
Device operates solely of its (internal) battery. |
1996 |
Recharg.B./Power Sc. |
1997 |
Rechargeable battery power or power scavenging. The device has a short-term supply of energy (must be at least one hour) that is continuously being replenished. The device's power is being replenished by harvesting and converting energy from the environment surrounding the device (e.g. solar, vibration, heat). |
1998 |
Idle |
1999 |
Active search |
2000 |
Looking for neighbors. |
2001 |
Negotiating |
2002 |
Quarantined |
2003 |
Operational |
2004 |
Suspended |
2005 |
Deep sleep |
2006 |
Ultra-low power |
2007 |
Wireless Signal Found |
2008 |
Network packets have been recognized |
2009 |
Wireless Signal Identified |
2010 |
Wireless Time Synchronized |
2011 |
WirelessHart Signal Identified |
2012 |
Network Admission Requested |
2013 |
Set on transmission of first join request |
2014 |
Join Retrying |
2015 |
Set after the first join request retry (i.e. when number of join requests > 2). Cleared when device is authenticated or when Active Search started. |
2016 |
Join Failed |
2017 |
Set on transition from Active Search mode to Deep Sleep mode. Cleared on transition from Deep Sleep to Active Search. |
2018 |
Network Security Clearance Granted |
2019 |
Network Manager Session Established |
2020 |
Network Joined |
2021 |
Network Joined. Normal superframe and links obtained. |
2022 |
Network Bandwidth Requested |
2023 |
Negotiating Network Properties. Gateway session obtained. |
2024 |
Join Complete |
2025 |
Normal operating mode. |
2026 |
None |
2027 |
No restrictions |
2028 |
SI Only |
2029 |
Restricted to SI Unit codes only |
2030 |
Open - accept all devices |
2031 |
Use Whitelist for access |
2032 |
Use Blacklist |
2033 |
Use Whitelist and Blacklist |
2034 |
Lockdown - disable join links |
2035 |
Process automation device |
2036 |
Discrete device |
2037 |
Hybrid:Process automation+discrete |
2038 |
I/O System |
2039 |
WirelessHART Process automation device |
2040 |
WirelessHART Discrete device |
2041 |
WirelessHART Process automation+discrete |
2042 |
WirelessHART Gateway |
2043 |
WirelessHART Access point |
2044 |
WirelessHART Process adapter |
2045 |
WirelessHART Discrete adapter |
2046 |
WirelessHART enabled handheld/portable maintenance tool |
2047 |
Don't attempt to join |
2048 |
Join now |
2049 |
Attempt to join immediately on powerup or reset |
2050 |
US |
2051 |
United States of America |
2052 |
JP |
2053 |
Japan |
2054 |
DE |
2055 |
Germany |
2056 |
FR |
2057 |
France |
2058 |
ES |
2059 |
Spain |
2060 |
RU |
2061 |
Russian Federation |
2062 |
CN |
2063 |
People's Republic of China |
2064 |
Nominal |
2065 |
Device Power Status is nominal |
2066 |
Low |
2067 |
Device Power Status is low |
2068 |
Critically Low |
2069 |
Device Power Status is critically low |
2070 |
Recharging - Low |
2071 |
Recharging - High |
2072 |
Secondary Master |
2073 |
Primary Master |
2074 |
Device Profile |
2075 |
Device Diagnostic Status 0 |
2076 |
Device Diagnostic Status 1 |
2077 |
I/O and Subdevice Status |
2078 |
WirelessHART Status |
2079 |
Time Set Option |
2080 |
Real Time Clock Flags |
2081 |
Country |
2082 |
Country of intended device installation |
2083 |
SI Unit Control |
2084 |
Indicates if device should only display SI unit codes |
2085 |
Burst Trigger Units |
2086 |
Burst Trigger Class |
2087 |
Wired HART Enabled |
2088 |
Enabled on Wired HART device connection only |
2089 |
Wireless HART Enabled |
2090 |
Enabled on WirelessHART device connection only |
2091 |
Both Wired and WirelessHart Enabled |
2092 |
Enabled on both Wired and WirelessHART connections |
2093 |
Burst Msg Trigger Mode |
2094 |
Event Status |
2095 |
Event Notification Control |
2096 |
Operate mode Mask |
2097 |
Not Defined |
2098 |
Power Source |
2099 |
Power source of the device |
2100 |
Wireless Mode |
2101 |
Join Status |
2102 |
The current location in the joining sequence of operations. |
2103 |
Network Access Mode |
2104 |
Join Mode |
2105 |
Power Status |
2106 |
Power status of the device |
2107 |
Master Mode |
2108 |
This sets the I/O System's Data Link Layer operation on all channels as either primary or secondary master mode. |
2109 |
Trend Units |
2110 |
Trend Device Variable Unit Code |
2111 |
Trend Classification |
2112 |
Trend Device Variable Classification |
2113 |
Trend Control |
2114 |
Device Status Mask |
2115 |
Ext dev status Mask |
2116 |
Device Diagnostic Status 0 Mask |
2117 |
Device Diagnostic Status 1 Mask |
2118 |
Device Diagnostic Status 2 Mask |
2119 |
Device Diagnostic Status 3 Mask |
2120 |
AO saturated Mask |
2121 |
AO fixed Mask |
2122 |
Latched Device Status |
2123 |
Latched Ext dev status |
2124 |
Latched Operate Mode |
2125 |
Latched Device Diagnostic Status 0 |
2126 |
Latched Device Diagnostic Status 1 |
2127 |
Latched Device Diagnostic Status 2 |
2128 |
Latched Device Diagnostic Status 3 |
2129 |
Latched AO saturated |
2130 |
Latched AO fixed |
2131 |
Wireless Module Device Type |
2132 |
Device type of the Wireless Radio |
2133 |
Wireless Module Manufacturer ID |
2134 |
Manufacturer of the Wireless Radio contained in this device |
2135 |
Subdevice Device Type |
2136 |
Device type of the subdevice attached to this system. |
2137 |
Subdevice Manufacturer Id |
2138 |
Manufacturer of the subdevice attached to this system. |
2139 |
Time Stamp |
2140 |
Relative time value on network |
2141 |
8u |
2142 |
Dynamic Variables Returned for Device Variables |
2143 |
Command Response Truncated |
2144 |
Configuration Change Counter Mismatch |
2145 |
Status bytes mismatch |
2146 |
Device Variable |
2147 |
Analog Channel Number |
2148 |
Analog Channel Number- Index into an array of Analog Channels. |
2149 |
Index 1 into Analog Channel Array |
2150 |
Index into Analog Channel Array- Is the first of an array of addresses, whose value is identified by the Analog Channel Code. |
2151 |
Index 2 into Analog Channel Array |
2152 |
Index into Analog Channel Array- Is the second of an array of addresses, whose value is identified by the Analog Channel Code. |
2153 |
Index 3 into Analog Channel Array |
2154 |
Index into Analog Channel Array- Is the third of an array of addresses, whose value is identified by the Analog Channel Code. |
2155 |
Index 4 into Analog Channel Array |
2156 |
Index into Analog Channel Array- Is the fourth of an array of addresses, whose value is identified by the Analog Channel Code. |
2157 |
Current Date |
2158 |
Current Date based upon the real-time clock in the field device |
2159 |
Current Time |
2160 |
Current Time based upon the real-time clock in the field device |
2161 |
Set Clock Date |
2162 |
Date to set the real-time clock in the field device to, or date that the real-time clock was last set |
2163 |
Set Clock Time |
2164 |
Time to set the real time clock in the field device to, or time that the real-time clock was last set |
2165 |
Are you sure? |
2166 |
No;Yes |
2167 |
Cold start is being executed,
Wait... |
2168 |
Enter Date: |
2169 |
Enter Time: |
2170 |
Clock set to: %{0} %{1} |
2171 |
Select alignment: |
2172 |
Break;Display -> HART;Load Defaults |
2173 |
default |
2174 |
Write new settings to the device? |
2175 |
Identnumber:
%{0}
Software Version:
%{2}
Production Date:
%{3} |
2176 |
Select Module |
2177 |
Identnumber:
%{0}
Hardware ID:
%{1}
Software Version:
%{2} |
2178 |
Production Date:
%{3}
Calibration Date:
%{4}
Board Serial No.:
%{5} |
2179 |
Errors have been reset. |
2180 |
Warm start is being executed,
Wait... |
2181 |
Enter password: |
2182 |
Service access enabled for 20 min. |
2183 |
Failed to enable service access. |
2184 |
Access level reset to %{0}. |
2185 |
Failed to reset access level. |
2186 |
Simulation finished |
2187 |
Simulation still running. |
2188 |
Enter Value in %{0} : |
2189 |
Error setting simulation value |
2190 |
Simulated value: %{1} %{0} |
2191 |
Enter value: |
2192 |
Simulated value: %{0} |
2193 |
Set No. Of pulses: |
2194 |
%{0} pulses sent. |
2195 |
Simulation still running. |
2196 |
Calibration finished |
2197 |
Calibrate zero? |
2198 |
Cancel;Default;Automatic |
2199 |
Default values set |
2200 |
Calibration takes %[.0f]{0}s.
Please wait ... |
2201 |
Calibration passed |
2202 |
Calibration failed |
2203 |
Invalid option |
2204 |
select pipe material |
2205 |
select liner materiall |
2206 |
select fluid |
2207 |
FDI Health Status: %{eFdiHealthStatus} |
2208 |
Mappings have been reset. |
2209 |
Set status simulation to |
2210 |
Failed to enable status simulation. |
2211 |
Status simulation disabled. |
2212 |
Status simulation enabled. |
2213 |
Failed to disable status simulation. |
2214 |
Totaliser has been reset. |
2215 |
Enter preset value in %{0} |
2216 |
Totaliser has been set. |
2217 |
Totaliser has been started. |
2218 |
Totaliser has been stopped. |
2219 |
Select analog output |
2220 |
Please wait ... |