0 |
Flow Velocity |
1 |
Volume Flow |
2 |
Mass Flow |
3 |
Temperature |
4 |
Density |
5 |
Sensor Average |
6 |
Sensor Deviation |
7 |
Drive Level |
8 |
Tube Frequency |
9 |
Strain 1 |
10 |
Strain 2 |
11 |
2 Phase Signal |
12 |
Concentration 1 |
13 |
Concentration 2 |
14 |
Mass Flow Concentration 1 |
15 |
Volume Flow Concentration 1 |
16 |
Mass Flow Concentration 2 |
17 |
Volume Flow Concentration 2 |
18 |
Mass Totaliser 1 |
19 |
Volume Totaliser 1 |
20 |
Mass Totaliser 2 |
21 |
Volume Totaliser 2 |
22 |
Mass Totaliser 3 |
23 |
Volume Totaliser 3 |
24 |
Snsr s/n |
25 |
Flow Velocity |
26 |
Flow Velocity Unit |
27 |
Unit for flow velocity.
For HART interface only, no correlation with device's local display. |
28 |
Flow Velocity Format |
29 |
Display format for flow velocity.
Local for HART applications, no correlation with device's local display. |
30 |
#X.XX (default) |
31 |
#X. |
32 |
#X.X |
33 |
#X.XXX |
34 |
#X.XXXX |
35 |
#X.XXXXX |
36 |
#X.XXXXXX |
37 |
#X.XXXXXXX |
38 |
#X.XXXXXXXX |
39 |
exponential format |
40 |
auto format |
41 |
Time constant |
42 |
Time constant of process input |
43 |
Flow Velocity |
44 |
Flow velocity |
45 |
.0f |
46 |
.1f |
47 |
.2f |
48 |
.3f |
49 |
.4f |
50 |
.5f |
51 |
.6f |
52 |
.7f |
53 |
.8f |
54 |
6e |
55 |
g |
56 |
Upper Sensor Limit |
57 |
Lower Sensor Limit |
58 |
Minimum Span |
59 |
Class |
60 |
Device Variable Class |
61 |
Family |
62 |
Device Variable Family |
63 |
Data Quality |
64 |
Process Data Quality 'PDQ' |
65 |
Limit Status |
66 |
Limit Status 'LS' |
67 |
Family Status |
68 |
Family Status 'FS' |
69 |
More device family status available |
70 |
Update Time |
71 |
Update Time Period 'UTP' |
72 |
Volume Flow Unit |
73 |
Unit for volume flow.
For HART interface only, no correlation with device's local display. |
74 |
Free Unit |
75 |
Volume Flow Format |
76 |
Format for volume flow.
Local for HART applications, no correlation with device's local display. |
77 |
Volume Flow |
78 |
Mass Flow Unit |
79 |
Unit for mass flow.
For HART interface only, no correlation with device's local display. |
80 |
Mass Flow Format |
81 |
Display format for mass flow.
Local for HART applications, no correlation with device's local display. |
82 |
Mass Flow |
83 |
Mass flow |
84 |
Temperature Unit |
85 |
Unit for Temperature.
For HART interface only, no correlation with device's local display. |
86 |
Temperature Format |
87 |
Display format for temperature.
Local for HART applications, no correlation with device's local display. |
88 |
Temperature |
89 |
Tube temperature |
90 |
Density Unit |
91 |
Unit for density.
For HART interface only, no correlation with device's local display. |
92 |
Density Format |
93 |
Display format for density.
Local for HART applications, no correlation with device's local display. |
94 |
Density |
95 |
Sensor Average Unit |
96 |
Unit for sensor average.
For HART interface only, no correlation with device's local display. |
97 |
Sensor Average Format |
98 |
Display format for sensor average.
Local for HART applications, no correlation with device's local display. |
99 |
Sensor Average |
100 |
Sensor Deviation Unit |
101 |
Unit for sensor deviation.
For HART interface only, no correlation with device's local display. |
102 |
Sensor Deviation Format |
103 |
Display format for sensor deviation.
Local for HART applications, no correlation with device's local display. |
104 |
Sensor Deviation |
105 |
Drive Level Unit |
106 |
Unit for drive level.
For HART interface only, no correlation with device's local display. |
107 |
Drive Level Format |
108 |
Display format for drive level.
Local for HART applications, no correlation with device's local display. |
109 |
Tube Frequency Unit |
110 |
Unit for tube frequency.
For HART interface only, no correlation with device's local display. |
111 |
Tube Frequency Format |
112 |
Display format for tube frequency.
Local for HART applications, no correlation with device's local display. |
113 |
Tube Frequency |
114 |
Tube Frequency |
115 |
Strain 1 Unit |
116 |
Unit for strain 1.
For HART interface only, no correlation with device's local display. |
117 |
Strain 1 Format |
118 |
Display format for strain 1.
Local for HART applications, no correlation with device's local display. |
119 |
Strain 2 Unit |
120 |
Unit for strain 2.
For HART interface only, no correlation with device's local display. |
121 |
Strain 2 Format |
122 |
Display format for strain 2.
Local for HART applications, no correlation with device's local display. |
123 |
2 Phase Signal Unit |
124 |
Unit for 2 phase signal.
For HART interface only, no correlation with device's local display. |
125 |
|
126 |
2 Phase Signal Format |
127 |
Display format for 2 phase signal.
Local for HART applications, no correlation with device's local display. |
128 |
Concentration 1 Unit |
129 |
Unit for concentration 1.
For HART interface only, no correlation with device's local display. |
130 |
°Bx |
131 |
°Bm |
132 |
Pto |
133 |
API |
134 |
Concentration 1 Format |
135 |
Display format for concentration 1.
Local for HART applications, no correlation with device's local display. |
136 |
Concentration 1 |
137 |
Concentration 2 Unit |
138 |
Unit for concentration 2.
For HART interface only, no correlation with device's local display. |
139 |
Concentration 2 Format |
140 |
Display format for concentration 2.
Local for HART applications, no correlation with device's local display. |
141 |
Concentration 2 |
142 |
Mass Flow Concentration 1 Unit |
143 |
Unit for mass flow concentration 1.
For HART interface only, no correlation with device's local display. |
144 |
Mass Flow Concentration 1 Format |
145 |
Display format for mass flow concentration 1.
Local for HART applications, no correlation with device's local display. |
146 |
Mass Flow Concentration 1 |
147 |
Mass flow concentration 1 |
148 |
Volume Flow Concentration 1 Unit |
149 |
Unit for volume flow concentration 1.
For HART interface only, no correlation with device's local display. |
150 |
Volume Flow Concentration 1 Format |
151 |
Display format for volume flow concentration 1.
Local for HART applications, no correlation with device's local display. |
152 |
Volume Flow Concentration 1 |
153 |
Volume flow concentration 1 |
154 |
Mass Flow Concentration 2 Unit |
155 |
Unit for mass flow concentration 2.
For HART interface only, no correlation with device's local display. |
156 |
Mass Flow Concentration 2 Format |
157 |
Display format for mass flow concentration 2.
Local for HART applications, no correlation with device's local display. |
158 |
Mass Flow Concentration 2 |
159 |
Mass flow concentration 2 |
160 |
Volume Flow Concentration 2 Unit |
161 |
Unit for volume flow concentration 2.
For HART interface only, no correlation with device's local display. |
162 |
Volume Flow Concentration 2 Format |
163 |
Display format for volume flow concentration 2.
Local for HART applications, no correlation with device's local display. |
164 |
Volume Flow Concentration 2 |
165 |
Volume flow concentration 2 |
166 |
Mass Totaliser 1 Unit |
167 |
Unit for mass totaliser 1.
For HART interface only, no correlation with device's local display. |
168 |
mg |
169 |
Milligrams |
170 |
Mass Totaliser 1 Format |
171 |
Display format for mass totaliser 1.
Local for HART applications, no correlation with device's local display. |
172 |
Mass Totaliser 1 |
173 |
Volume Totaliser 1 Unit |
174 |
Unit for volume totaliser 1.
For HART interface only, no correlation with device's local display. |
175 |
mL |
176 |
Milliliters |
177 |
Volume Totaliser 1 Format |
178 |
Display format for volume totaliser 1.
Local for HART applications, no correlation with device's local display. |
179 |
Volume Totaliser 1 |
180 |
Mass Totaliser 2 Unit |
181 |
Unit for mass totaliser 2.
For HART interface only, no correlation with device's local display. |
182 |
Mass Totaliser 2 Format |
183 |
Display format for mass totaliser 2.
Local for HART applications, no correlation with device's local display. |
184 |
Mass Totaliser 2 |
185 |
Volume Totaliser 2 Unit |
186 |
Unit for volume totaliser 2.
For HART interface only, no correlation with device's local display. |
187 |
Volume Totaliser 2 Format |
188 |
Display format for volume totaliser 2.
Local for HART applications, no correlation with device's local display. |
189 |
Volume Totaliser 2 |
190 |
Mass Totaliser 3 Unit |
191 |
Unit for mass totaliser 3.
For HART interface only, no correlation with device's local display. |
192 |
Mass Totaliser 3 Format |
193 |
Display format for mass totaliser 3.
Local for HART applications, no correlation with device's local display. |
194 |
Mass Totaliser 3 |
195 |
Volume Totaliser 3 Unit |
196 |
Unit for volume totaliser 3.
For HART interface only, no correlation with device's local display. |
197 |
Volume Totaliser 3 Format |
198 |
Display format for volume totaliser 3.
Local for HART applications, no correlation with device's local display. |
199 |
Volume Totaliser 3 |
200 |
eSelectionAnalogOutput |
201 |
A |
202 |
D |
203 |
B |
204 |
C |
205 |
eSelectionCurrentOutput |
206 |
4.1f |
207 |
SV % range |
208 |
Percent of range; tracks the associated measured value with respect to the range defined by the Lower Range Value and Upper Range Value. Frequency output D if available. |
209 |
8.3f |
210 |
SV Output Value |
211 |
Analog output value that tracks the associated measured value. Frequency output D if available. |
212 |
TV % range |
213 |
Percent of range; tracks the associated measured value with respect to the range defined by the Lower Range Value and Upper Range Value. Current/frequency output A if available (Modular IO / Exi IO). |
214 |
TV Output Value |
215 |
Analog output value that tracks the associated measured value. Current/frequency output A. |
216 |
QV % range |
217 |
Percent of range; tracks the associated measured value with respect to the range defined by the Lower Range Value and Upper Range Value. Current/frequency output B if available (Modular IO / Exi IO). |
218 |
QV Output Value |
219 |
Analog output value that tracks the associated measured value. Current/frequency output B. |
220 |
MthUpdateInterModuleDvac |
221 |
MthOflAlignInterModuleDvac |
222 |
MthAlignInterModuleDyvCdDevIo |
223 |
MthOflAlignInterModuleDyvDiagnosis |
224 |
MthOflAlignInterModuleDyvConcentration |
225 |
MthOflAlignInterModuleDyvTotalizer |
226 |
Align HART Units |
227 |
Align 'HART units' (for measured values) to 'display units' (for configuration parameters) or to default.
(Fct. C5.5) |
228 |
start |
229 |
Measured Values |
230 |
Concentration Values |
231 |
Totaliser |
232 |
Diagnosis Values |
233 |
Output, HART Dynamic Vars |
234 |
Primary |
235 |
Secondary |
236 |
Tertiary |
237 |
Quaternary |
238 |
Output (Chart) |
239 |
Output (Bar) |
240 |
Output (Scope) |
241 |
PV Measured Value |
242 |
PV Output |
243 |
SV Measured Value |
244 |
SV Output |
245 |
TV Measured Value |
246 |
TV Output |
247 |
QV Measured Value |
248 |
QV Output |
249 |
Measured Values (Chart) |
250 |
Measured Values (Bar) |
251 |
Measured Values (Scope) |
252 |
Concentration Values (Chart) |
253 |
Concentration Values (Bar) |
254 |
Concentration Values (Scope) |
255 |
Diagnosis Values (Chart) |
256 |
Diagnosis Values (Bar) |
257 |
Diagnosis Values (Scope) |
258 |
HART |
259 |
Totalizer |
260 |
MFC 400 |
261 |
Write Protect |
262 |
Failure |
263 |
Operational fault in device. No measurement possible.
(NE 107 status signal). |
264 |
Function check |
265 |
Testing mode by invoking test or simulation functions.
(NE 107 status signal). |
266 |
Out of specification |
267 |
Out of specification, measurement continues with less accuracy.
(NE 107 status signal). |
268 |
Maintenance required |
269 |
Maintenance required, function will soon be restricted.
(NE 107 status signal). |
270 |
Status Simulation Active |
271 |
Discrete Variable Simulation Active |
272 |
Event Notification Overflow |
273 |
Tag |
274 |
Tag: Text that is associated with the Field Device installation. It is also used as a type of data link layer address handle.
(Fct. A2, C6.1.1) |
275 |
Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1).
(Fct. C6.8.2) |
276 |
Text that is associated with the Field Device. This text can be used by the user in any way.
(Fct. C6.8.3) |
277 |
Text that is associated with the Field Device. This text can be used by the user in any way.
(Fct. C6.8.4) |
278 |
Config: No Meas.Value |
279 |
|
280 |
Electr: Operation Info. |
281 |
Proc: Current Input |
282 |
Electr: IO Connection |
283 |
Proc: Signal Search |
284 |
Proc: 2 Phase Flow |
285 |
Proc: Signal Low |
286 |
Config: Totaliser |
287 |
Proc: System Control |
288 |
Electr: Power Failure |
289 |
Sensor |
290 |
Electronics |
291 |
Configuration |
292 |
Process |
293 |
PV Output Value |
294 |
Loop current value of the output that tracks the associated measured value. Current output A (basic IO) or C (modular IO / Exi IO) respectively. |
295 |
PV % range |
296 |
Percent of range; tracks the associated measured value with respect to the range defined by the Lower Range Value and Upper Range Value. Current output A (basic IO) or C (modular IO / Exi IO) respectively. |
297 |
Apply values |
298 |
Currently measured values will be taken as Upper Range Value and Lower Range Value for the PV current output (A or C respectively). |
299 |
Loop test |
300 |
Manually manipulate the current output A/C to a selected constant output value. |
301 |
Function of Current Output A/C must be set to 'Mass Flow' |
302 |
Automatic zero calibration |
303 |
Measures flow in the pipeline for automatic zero adjust. (Function of current output A/C must be 'Mass Flow'!). |
304 |
D/A trim PV |
305 |
Calibration of the PV current output (A or C respectively) with an external reference. |
306 |
Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable.
Equivalent to measurement of current output A (basic IO) or C (modular IO / Exi IO) respectively.
(Fct. C5.1) |
307 |
Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable.
Equivalent to measurement of frequency output D if available.
(Fct. C5.2) |
308 |
Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable.
Equivalent to measurement of current/frequency output A if available (Modular IO / Exi IO).
(Fct. C5.3) |
309 |
QV is |
310 |
Fourth Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Fourth Variable dynamic variable.
Equivalent to measurement of current/frequency output B if available (Modular IO / Exi IO).
(Fct. C5.4) |
311 |
Fix analog output |
312 |
Manually manipulate a selected Analog Output to a selected constant output value. |
313 |
D/A trim Analog Output |
314 |
Calibration of a selected output with an external reference. |
315 |
Set Date |
316 |
Set Time |
317 |
Date |
318 |
Displays device date & time setting yyyy-mm-dd hh:mm
(Fct. B2.2) |
319 |
Time |
320 |
%H:%M |
321 |
Invalid date code |
322 |
Online Mode? |
323 |
Can the Host Application currently communicate with the field device? |
324 |
yes |
325 |
no |
326 |
DD-Version |
327 |
Version number of the device description according to NAMUR recommendation.
You are currently working with version: 01.11 |
328 |
01.11 |
329 |
PreSetVersionDd |
330 |
Reset Configuration Changed Flag |
331 |
Reset of the HART 'Configuration Changed' flag. |
332 |
Device reset |
333 |
Perform a "cold start" (like power-on start). |
334 |
Value |
335 |
Test values current output |
336 |
4 mA |
337 |
5 mA |
338 |
10 mA |
339 |
12 mA |
340 |
20 mA |
341 |
Test values frequency output |
342 |
1 puls/s |
343 |
10 puls/s |
344 |
100 puls/s |
345 |
1000 puls/s |
346 |
10000 puls/s |
347 |
AbmLeaveFixedMode |
348 |
Simulation A/C |
349 |
Simulation of current output A (basic IO) or C (modular IO / Exi IO). |
350 |
Simulation D |
351 |
Simulation of frequency output D. |
352 |
Simulation A |
353 |
Simulation of current/frequency output A (modular IO / Exi IO). |
354 |
Simulation B |
355 |
Simulation of current/frequency output B (modular IO / Exi IO). |
356 |
Set Date and Time |
357 |
Sets device date & time setting yyyy-mm-dd hh:mm
(Fct. C6.6.6) |
358 |
HART analog channels |
359 |
I/O HART |
360 |
Mapping of Variables |
361 |
PV Analog Channel |
362 |
SV Analog Channel |
363 |
TV Analog Channel |
364 |
QV Analog Channel |
365 |
Identification |
366 |
Device info |
367 |
HART Revisions |
368 |
Preambles |
369 |
Reserved |
370 |
Mapping to condensed status signal (NE 107). |
371 |
Failure ('F') |
372 |
Function Check ('C') |
373 |
Out of Specification ('S') |
374 |
Maintenance Required ('M') |
375 |
No Effect |
376 |
Not Defined |
377 |
State to be simulated. |
378 |
Reset |
379 |
Set |
380 |
Zero Calibr. Running |
381 |
PROFIBUS No Data |
382 |
PROFIBUS Baudrate |
383 |
PROFIBUS Passivated |
384 |
PROFIBUS Clear Data |
385 |
PROFIBUS Sync Mode |
386 |
PROFIBUS Freeze Mode |
387 |
Tot 1 Stopped |
388 |
If totaliser to continue counting, activate yes in Fct. C4.y.9 (start totaliser). |
389 |
Tot 2 Stopped |
390 |
Tot 3 Stopped |
391 |
Tot 1 FB4 Threshold |
392 |
Tot 2 FB5 Threshold |
393 |
Tot 3 FB6 Threshold |
394 |
Control In A Active |
395 |
Control In B Active |
396 |
Status Out A Active |
397 |
Status Out B Active |
398 |
Status Out C Active |
399 |
Status Out D Active |
400 |
Disp. 1 Overrange |
401 |
Check configuration settings of display line 1. |
402 |
Disp. 2 Overrange |
403 |
Check configuration settings of display line 2. |
404 |
Optical Interf. Active |
405 |
The keys are ready for operation again
approx. 60 sec. after the end of the data
transfer/removal of the optical interface. |
406 |
IO A No Meas. Values |
407 |
Select another measuement for IO A in menu C3.2 or activate the measurement in C5.1 for diagnostic values or in menu C2 for concentration values |
408 |
IO B No Meas. Values |
409 |
Select another measuement for IO B in menu C3.3 or activate the measurement in C5.1 for diagnostic values or in menu C2 for concentration values |
410 |
IO C No Meas. Values |
411 |
Select another measuement for IO C in menu C3.4 or activate the measurement in C5.1 for diagnostic values or in menu C2 for concentration values |
412 |
IO D No Meas. Values |
413 |
Select another measuement for IO D in menu C3.5 or activate the measurement in C1.5 for diagnostic values or in menu C2 for concentration values |
414 |
Tot 1 No Meas. Values |
415 |
Select another measuement for totaliser 1 in menu C4.1 or activate the measurement in C1.5 for diagnostic values or in menu C2 for concentration values |
416 |
Tot 2 No Meas. Values |
417 |
Select another measuement for totaliser 2 in menu C4.2 or activate the measurement in C1.5 for diagnostic values or in menu C2 for concentration values |
418 |
Tot 3 No Meas. Values |
419 |
Select another measuement for totaliser 3 in menu C4.3 or activate the measurement in C1.5 for diagnostic values or in menu C2 for concentration values |
420 |
Disp. 1 no measure values |
421 |
Select another measuement fo measure page 1 or activate the measurement in C1.5 for diagnostic values or in menu C2 for concentration values |
422 |
Disp. 2 no measure values |
423 |
Select another measuement fo measure page 2 or activate the measurement in C1.5 for diagnostic values or in menu C2 for concentration values |
424 |
Change NE107 status signal for status group "Electr: Power Failure"
(Fct. C1.5.13) |
425 |
Tot 1 Power Failure |
426 |
Check Totaliser value. |
427 |
Tot 2 Power Failure |
428 |
Tot 3 Power Failure |
429 |
Tot 1 FB4 Power Failure |
430 |
Tot 2 FB5 Power Failure |
431 |
Tot 3 FB6 Power Failure |
432 |
Power Failure Detected |
433 |
Change NE107 status signal for status group " Proc: System Ctrl."
(Fct. C1.5.11) |
434 |
System Control Active |
435 |
Change NE107 status signal for status group "Config: Totaliser"
(Fct. C1.5.12) |
436 |
Tot 1 FB4 Overflow |
437 |
Check totaliser format. |
438 |
Tot 2 FB5 Overflow |
439 |
Tot 3 FB6 Overflow |
440 |
Tot 1 Overflow |
441 |
Tot 2 Overflow |
442 |
Tot 3 Overflow |
443 |
Change NE107 status signal for status group "Proc: Signal Low"
(Fct. C1.5.7) |
444 |
Sensor Signal Low |
445 |
Check for entrained gas or viscosity of product. |
446 |
Change NE107 status signal for status group "Proc: 2 Phase Flow"
(Fct. C1.5.10) |
447 |
2 Phase Flow Detected |
448 |
Check process for entrained gas. |
449 |
Change NE107 status signal for status group "Proc: Signal Search"
(Fct. C1.5.8) |
450 |
Sensor Signal Search |
451 |
Check process conditions (entrained gas, viscosity). In case of remote sensor check sensor cabling. Check internal sensor connections. |
452 |
Change NE107 status signal for status group "Electr: IO Connection"
(Fct. C1.5.14) |
453 |
IO A Connection |
454 |
Check cable and connection at terminal A, reduce load. |
455 |
IO B Connection |
456 |
Check cable and connection at terminal B, reduce load. |
457 |
IO C Open Connector |
458 |
Check cable and connection at terminal C, reduce load. |
459 |
Change NE107 status signal for status group "Proc: Current Input"
(Fct. C1.5.9) |
460 |
IO A Error Current |
461 |
Check device connected to current input A. This devices submits an error current. |
462 |
IO B Error Current |
463 |
Check device connected to current input B. This devices submits an error current. |
464 |
Backup 1 Data Faulty |
465 |
Use the menu setup > device > special function > save settings to the save the related data set.
If this does not help, please contact the factory. |
466 |
Backup 2 Data Faulty |
467 |
Backplane Data Faulty |
468 |
Make sure, that the converter is correctly mounted and fixed into the housing.
Change one parameter. The status should disappear within 1 minute.
If this does not help, please contact the factory. |
469 |
Factory Data Faulty |
470 |
Please contact the factory. |
471 |
Backplane Difference |
472 |
Change one parameter. The status should disappear within 1 minute.
If this does not help, please contact the factory |
473 |
Mem. Life Exceeded |
474 |
Exchange electronics assembly |
475 |
Proc.Temp.Out of Range |
476 |
Check process conditions. |
477 |
Flow Out of Range |
478 |
Vol. Flow Out of Range |
479 |
Prod.Density Out of Range |
480 |
Check process conditions and density calibration. |
481 |
Velocity Out of Range |
482 |
Check process conditions or pipe diameter setting. |
483 |
PROFIBUS Uncertain |
484 |
IO A Overrange |
485 |
If the input value is already limited, see the measures listed there.
Check the range settings of the related output |
486 |
IO B Overrange |
487 |
IO C Overrange |
488 |
IO D Overrange |
489 |
Electr.Temp.A Out of Spec |
490 |
Move electronics away from process influences. Protect the electronics against direct sunlight. |
491 |
Electr.Temp.C Out of Spec |
492 |
Electr.Temp.Out of Spec |
493 |
Temp. Or Strain Res. Def. |
494 |
Check cabling in case of remote device or replace sensor. |
495 |
Sensor in Stop Mode |
496 |
For normal operation change operation mode to measurement mode |
497 |
Sensor in Standby Mode |
498 |
Sensor Simulation Active |
499 |
Turn off simulation mode |
500 |
Sensor Starting up |
501 |
Fieldbus Sim. Active |
502 |
Check Fieldbus configuration. |
503 |
PROFIBUS Sim/Man Active |
504 |
Check PROFIBUS configuration. |
505 |
Tot 1 FB4 Sim. Active |
506 |
Tot 2 FB5 Sim. Active |
507 |
Tot 3 FB6 Sim. Active |
508 |
Tot 1 FB4 Man. Active |
509 |
Tot 2 FB5 Man. Active |
510 |
Tot 3 FB6 Man. Active |
511 |
IO A Simulation Active |
512 |
Turn off simulation |
513 |
IO B Simulation Active |
514 |
IO C Simulation Active |
515 |
IO D Simulation Active |
516 |
BM Configuration |
517 |
Check the configuration of the related function. Reset the configuration to the factory settings. If error does not disappear, contact service. |
518 |
DM Configuration |
519 |
Check the configuration of the related function. Reset the configuration to the factory settings. If error does not disappear, contact service. |
520 |
Process Input Config. |
521 |
Check process input configuration or reset to factory configuration. |
522 |
Density Calibration |
523 |
Restart density calibration, check product and operation mode or reset to factory settings |
524 |
Fieldbus Config. |
525 |
Check fieldbus configuration or reset to factory configuration. |
526 |
PROFIBUS Config. |
527 |
Check PROFIBUS configuration or reset to factory configuration. |
528 |
Tot 1 FB4 Unit Error |
529 |
Check unit in Totaliser 1 FB2 or reset to factory settings. |
530 |
Tot 2 FB5 Unit Error |
531 |
Check unit in Totaliser 2 FB3 or reset to factory settings. |
532 |
Tot 3 FB6 Unit Error |
533 |
Check unit in Totaliser 3 FB4 or reset to factory settings. |
534 |
Modbus Config. |
535 |
Check Modbus settings or reset to factory settings. |
536 |
Display Config. |
537 |
Check display configuration or reset to factory configuration. |
538 |
IO1 Configuration |
539 |
Check IO 1 configuration or reset to factory configuration. |
540 |
IO2 Configuration |
541 |
Check IO 2 configuration or reset to factory configuration. |
542 |
Tot 1 Configuration |
543 |
Check Totaliser 1 configuration or reset to factory configuration. |
544 |
Tot 2 Configuration |
545 |
Check Totaliser 2 configuration or reset to factory configuration. |
546 |
Tot 3 Configuration |
547 |
Check Totaliser 3 configuration or reset to factory configuration. |
548 |
IO A Configuration |
549 |
Check IO A configuration or reset to factory configuration. |
550 |
IO B Configuration |
551 |
Check IO B configuration or reset to factory configuration. |
552 |
IO C Configuration |
553 |
Check IO C configuration or reset to factory configuration. |
554 |
IO D Configuration |
555 |
Check IO D configuration or reset to factory configuration. |
556 |
System Error |
557 |
Perform a power reset. If the status returns, contact the factory. |
558 |
System Error A |
559 |
System Error C |
560 |
HW Combination Error |
561 |
BM Failure |
562 |
DM Failure |
563 |
Process Input Failure |
564 |
Fieldbus Failure |
565 |
PROFIBUS Failure |
566 |
Modbus Failure |
567 |
IO 1 Failure |
568 |
IO 2 Failure |
569 |
Tot 1 Failure |
570 |
Tot 2 Failure |
571 |
Tot 3 Failure |
572 |
IO A Failure |
573 |
IO B Failure |
574 |
IO C Failure |
575 |
Sensor Containment Dam. |
576 |
Replace sensor |
577 |
Sensor Error |
578 |
Status Simulation |
579 |
Enables or disables the Status Simulation Mode. |
580 |
disabled |
581 |
enabled |
582 |
GDC timeout |
583 |
GDC error |
584 |
GDC delayed response |
585 |
Starting Status Map Index must be even value. |
586 |
Reset to default |
587 |
Reset the mappings to the Condensed Status to default values. |
588 |
Enable/disable Status Simulation |
589 |
Enable/disable status simulation. |
590 |
Status Display |
591 |
Condensed Status (NE 107) |
592 |
Standard |
593 |
Detail |
594 |
Additional |
595 |
Simulation Values |
596 |
Status Mapping |
597 |
Velocity |
598 |
Displays current unfiltered Flow Velocity
(Fct. B2.5) |
599 |
Displays current unfiltered Volume Flow
(Fct. B2.4) |
600 |
Displays current unfiltered Temperature
(Fct. B2.7) |
601 |
Displays current unfiltered Density
(Fct. B2.6) |
602 |
Sets simulated value for Mass Flow
(Fct. B1.1, C1.9.1) |
603 |
Sets simulated value for Density
(Fct. B1.3, C1.9.3) |
604 |
Sets simulated value for Temperature
(Fct. B1.4, C1.9.4) |
605 |
Displays current unfiltered Mass Flow
(Fct. B2.3) |
606 |
Displays current value for the measuring strain 1
(Fct. B2.8) |
607 |
Displays current value for the measuring strain 2
(Fct. B2.9) |
608 |
Tube Frequency |
609 |
Displays current vibration frequency of the measuring tube
(Fct. B2.10) |
610 |
Drive Level |
611 |
Displays current drive level to activate vibration
(Fct. B2.11) |
612 |
Sensor A Level |
613 |
Displays current vibration amplitude of Sensor A
(Fct. B2.12) |
614 |
Sensor B Level |
615 |
Displays current vibration amplitude of Sensor B
(Fct. B2.13) |
616 |
Displays current 2-phase indication value
(Fct. B2.14) |
617 |
SE PCB Temperature |
618 |
Displays current temperature of the SE PCB
(Fct. B2.15) |
619 |
Max. Rec. Temp. |
620 |
Displays the maximum recorded sensor temperature whilst powered
(Fct. C1.5.1) |
621 |
Min. Rec. Temp. |
622 |
Displays the minimum sensor temperature whilst powered
(Fct. C1.5.2) |
623 |
Time Shift |
624 |
Displays the actual time shift measured by the device
(Fct. D1.3.1) |
625 |
.4e |
626 |
Zero Flow Offset |
627 |
Displays the stored zero offset in ns
(Fct. D1.3.2) |
628 |
.3e |
629 |
Flow Temp. Comp. |
630 |
Displays the actual flow temperature compensation
(Fct. D1.3.3) |
631 |
Beta Correction |
632 |
Displays the actual beta flow compensation
(Fct. D1.3.4) |
633 |
Density Temp. Comp. |
634 |
Displays the actual density temperature compensation
(Fct. D1.3.5) |
635 |
Density Flow Comp. |
636 |
Displays the actual density flow compensation
(Fct. D1.3.6) |
637 |
CF9 |
638 |
Displays the CF9 value used for density measurement
(Fct. D1.3.7) |
639 |
CF10 |
640 |
Displays the CF10 value used for density measurement
(Fct. D1.3.8) |
641 |
Min. Tube Amplitude |
642 |
Sets the minimum amplitude of vibration of the measuring tube(s) for startup condition
(Fct. D1.4.2) |
643 |
Nominal Mass Flow |
644 |
Displays the nominal mass flow of the sensor
(Fct. C1.6.3) |
645 |
6.1f |
646 |
Sets simulated value for Volume Flow
(Fct. B1.2, C1.9.2) |
647 |
Sensor ID |
648 |
Displays the idenfication number of the sensor
(Fct. C1.6.2) |
649 |
Concentration 1 function |
650 |
Concentration 1 function.
In online mode the setting should be changed with the corresponding online-method only,
as dependent units need to be updated.
(Fct. C2.2.1) |
651 |
Off |
652 |
Brix |
653 |
% Mass |
654 |
% Volume |
655 |
Baume 144 |
656 |
Baume 145 |
657 |
% NaOH |
658 |
Plato |
659 |
API |
660 |
% Alcohol by mass |
661 |
% Alcohol by volume |
662 |
Concentration 2 function |
663 |
Concentration 2 function.
In online mode the setting should be changed with the corresponding online-method only,
as dependent units need to be updated.
(Fct. C2.3.1) |
664 |
Concentration |
665 |
Concentration measurement enabled |
666 |
On |
667 |
Diagnosis 1 |
668 |
Diagnosis 1.
In online mode the setting should be changed with the corresponding online-method only,
as dependent units need to be updated.
(Fct. C1.5.4) |
669 |
Diagnosis 2 |
670 |
Diagnosis 2.
In online mode the setting should be changed with the corresponding online-method only,
as dependent units need to be updated.
(Fct. C1.5.5) |
671 |
Diagnosis 3 |
672 |
Diagnosis 3.
In online mode the setting should be changed with the corresponding online-method only,
as dependent units need to be updated.
(Fct. C1.5.6) |
673 |
Act. Operat. Mode |
674 |
Displays the current operating mode
(Fct. B2.16) |
675 |
Stop |
676 |
Startup |
677 |
Measuring |
678 |
Standby |
679 |
Calibrate Zero |
680 |
Calibration Date |
681 |
Displays the date of calibration of the sensor
(Fct. C1.6.6) |
682 |
Operation Mode |
683 |
Sets the operating mode
(Fct. A9) |
684 |
Zero Add. Offset |
685 |
Manual setting of additional zero offset
(Fct. C1.1.2) |
686 |
Zero Calibration |
687 |
Zero Calibration % |
688 |
Displays the stored zero offset in %
(Fct. D1.3.9) |
689 |
Temp. At Zero Cal. |
690 |
Displays the temperature at which the stored zero was made
(Fct. D1.3.10) |
691 |
DCF1 |
692 |
Displays the sensor density calibration coefficient DCF1
(Fct. C1.8.1) |
693 |
0 |
694 |
1 |
695 |
2 |
696 |
3 |
697 |
DCF2 |
698 |
Displays the sensor density calibration coefficient DCF2
(Fct. C1.8.2) |
699 |
DCF3 |
700 |
Displays the sensor density calibration coefficient DCF3
(Fct. C1.8.3) |
701 |
DCF4 |
702 |
Displays the sensor density calibration coefficient DCF4
(Fct. C1.8.4) |
703 |
DCF5 |
704 |
Displays the sensor density calibration coefficient DCF5
(Fct. C1.8.5) |
705 |
DCF6 |
706 |
Displays the sensor density calibration coefficient DCF6
(Fct. C1.8.6) |
707 |
DCF7 |
708 |
Displays the sensor density calibration coefficient DCF7
(Fct. C1.8.7) |
709 |
DCF8 |
710 |
Displays the sensor density calibration coefficient DCF8
(Fct. C1.8.8) |
711 |
Density Calibration? |
712 |
Start Density Calibration
(Fct. C1.2.1) |
713 |
1 Point Calibration |
714 |
2nd Calibration Point |
715 |
Factory Calib. |
716 |
Break |
717 |
Density Calib. Product |
718 |
Density Calib. Product
(Fct. C1.2.1) |
719 |
Empty |
720 |
Pure Water |
721 |
Town Water |
722 |
Other |
723 |
Product Density Value |
724 |
Last Density Cal. |
725 |
Displays date last density calibration yyyy-mm-dd
(Fct. C1.2.9) |
726 |
Standard Density k0 |
727 |
Sets k0 value for Standard density
(Fct. C1.2.6) |
728 |
Standard Density k1 |
729 |
Sets k1 value for Standard density
(Fct. C1.2.7) |
730 |
Standard Density k2 |
731 |
Sets k2 value for Standard density
(Fct. C1.2.8) |
732 |
Fixed Density Value |
733 |
Density Ref. Temp. |
734 |
Pipe Diameter |
735 |
Density Mode Sel. |
736 |
Set Density Mode
(Fct. C1.2.2) |
737 |
Actual |
738 |
Fixed |
739 |
Referred |
740 |
Standard |
741 |
Set Density value for Fixed Density
(Fct. C1.2.1/3) |
742 |
Reference Temperature |
743 |
Reference Temperature for referred density or standard density.
(Fct. C1.2.3/5) |
744 |
Ref. Density Slope |
745 |
Set Density slope for Referred density
(Fct. C1.2.4) |
746 |
Low Flow Cutoff |
747 |
Low Flow Cutoff
(Fct. C1.3.4) |
748 |
Conc. Offset |
749 |
Sets an additional offset for the 1st concentration measurement
(Fct. C2.2.2) |
750 |
CCF01 |
751 |
Sets concentration coefficient CCF1 used in Concentration Data 1
(Fct. C2.4.1) |
752 |
Linear |
753 |
Non Linear |
754 |
Max. Dens. |
755 |
Max. Temp. |
756 |
Conc. Product |
757 |
Sets which 1st concentration product is displayed
(Fct. C2.2.3) |
758 |
% Of Product A |
759 |
% Of Product B |
760 |
Min. Dens. |
761 |
Min. Temp. |
762 |
CCF02 |
763 |
Sets concentration coefficient CCF2 used in Concentration Data 1
(Fct. C2.4.2) |
764 |
CCF03 |
765 |
Sets concentration coefficient CCF3 used in Concentration Data 1
(Fct. C2.4.3) |
766 |
CCF04 |
767 |
Sets concentration coefficient CCF4 used in Concentration Data 1
(Fct. C2.4.4) |
768 |
CCF05 |
769 |
Sets concentration coefficient CCF5 used in Concentration Data 1
(Fct. C2.4.5) |
770 |
CCF06 |
771 |
Sets concentration coefficient CCF6 used in Concentration Data 1
(Fct. C2.4.6) |
772 |
CCF07 |
773 |
Sets concentration coefficient CCF7 used in Concentration Data 1
(Fct. C2.4.7) |
774 |
CCF08 |
775 |
Sets concentration coefficient CCF8 used in Concentration Data 1
(Fct. C2.4.8) |
776 |
CCF09 |
777 |
Sets concentration coefficient CCF9 used in Concentration Data 1
(Fct. C2.4.9) |
778 |
CCF10 |
779 |
Sets concentration coefficient CCF10 used in Concentration Data 1
(Fct. C2.4.10) |
780 |
CCF11 |
781 |
Sets concentration coefficient CCF11 used in Concentration Data 1
(Fct. C2.4.11) |
782 |
CCF12 |
783 |
Sets concentration coefficient CCF12 used in Concentration Data 1
(Fct. C2.4.12) |
784 |
Sets an additional offset for the 2nd concentration measurement
(Fct. C2.3.2) |
785 |
Sets concentration coefficient CCF1 used in Concentration Data 2
(Fct. C2.5.1) |
786 |
Sets which 2nd concentration product is displayed
(Fct. C2.3.3) |
787 |
Sets concentration coefficient CCF2 used in Concentration Data 2
(Fct. C2.5.2) |
788 |
Sets concentration coefficient CCF3 used in Concentration Data 2
(Fct. C2.5.3) |
789 |
Sets concentration coefficient CCF4 used in Concentration Data 2
(Fct. C2.5.4) |
790 |
Sets concentration coefficient CCF5 used in Concentration Data 2
(Fct. C2.5.5) |
791 |
Sets concentration coefficient CCF6 used in Concentration Data 2
(Fct. C2.5.6) |
792 |
Sets concentration coefficient CCF7 used in Concentration Data 2
(Fct. C2.5.7) |
793 |
Sets concentration coefficient CCF8 used in Concentration Data 2
(Fct. C2.5.8) |
794 |
Sets concentration coefficient CCF9 used in Concentration Data 2
(Fct. C2.5.9) |
795 |
Sets concentration coefficient CCF10 used in Concentration Data 2
(Fct. C2.5.10) |
796 |
Sets concentration coefficient CCF11 used in Concentration Data 2
(Fct. C2.5.11) |
797 |
Sets concentration coefficient CCF12 used in Concentration Data 2
(Fct. C2.5.12) |
798 |
Conc. Data Sel. |
799 |
Concentration Selector
(Fct. C2.1) |
800 |
Conc. Data 1 |
801 |
Conc. Data 2 |
802 |
Sets pipe diameter in mm used to calculate flow velocity
(Fct. C1.1.3) |
803 |
Flow Correction |
804 |
Sets additional correction for mass flow
(Fct. C1.1.4) |
805 |
Flow Direction |
806 |
Sets polarity of flow direction
(Fct. A7, C1.3.1) |
807 |
Forwards |
808 |
Backwards |
809 |
Press. Supp. Time |
810 |
Sets the time that pressure suppression is active
(Fct. C1.3.2) |
811 |
Press. Supp. Cutoff |
812 |
Sets the additional cutoff used during pressure suppression
(Fct. C1.3.3) |
813 |
Function |
814 |
Sets the function of system control
(Fct. C1.4.1) |
815 |
No Action |
816 |
Flow = 0 |
817 |
Condition |
818 |
Sets the condition for activating the system control
(Fct. C1.4.2) |
819 |
Sets the upper limit for condition selected by C1.4.2
(Fct. C1.4.3) |
820 |
Sets the lower limit for condition selected by C1.4.2
(Fct. C1.4.4) |
821 |
Empty Density |
822 |
Density configuration enabled |
823 |
Max. Allowed Temp. |
824 |
Displays the maximum permitted temperature for the sensor
(Fct. C1.6.4) |
825 |
Min. Allowed Temp. |
826 |
Displays the minimum permitted temperature for the sensor
(Fct. C1.6.5) |
827 |
CF1 |
828 |
Displays the sensor flow calibration coefficient CF1
(Fct. C1.7.1) |
829 |
CF2 |
830 |
Displays the sensor flow calibration coefficient CF2
(Fct. C1.7.2) |
831 |
CF3 |
832 |
Displays the sensor flow calibration coefficient CF3
(Fct. C1.7.3) |
833 |
CF4 |
834 |
Displays the sensor flow calibration coefficient CF4
(Fct. C1.7.4) |
835 |
CF5 |
836 |
Displays the sensor flow calibration coefficient CF5
(Fct. C1.7.5) |
837 |
CF6 |
838 |
Displays the sensor flow calibration coefficient CF6
(Fct. C1.7.6) |
839 |
CF7 |
840 |
Displays the sensor flow calibration coefficient CF7
(Fct. C1.7.7) |
841 |
CF8 |
842 |
Displays the sensor flow calibration coefficient CF8
(Fct. C1.7.8) |
843 |
CF11 |
844 |
Displays the sensor flow calibration coefficient CF11
(Fct. C1.7.9) |
845 |
CF12 |
846 |
Displays the sensor flow calibration coefficient CF12
(Fct. C1.7.10) |
847 |
CF13 |
848 |
Displays the sensor flow calibration coefficient CF13
(Fct. C1.7.11) |
849 |
CF14 |
850 |
Displays the sensor flow calibration coefficient CF14
(Fct. C1.7.12) |
851 |
CF15 |
852 |
Displays the sensor flow calibration coefficient CF15
(Fct. C1.7.13) |
853 |
CF16 |
854 |
Displays the sensor flow calibration coefficient CF16
(Fct. C1.7.14) |
855 |
CF17 |
856 |
Displays the sensor flow calibration coefficient CF17
(Fct. C1.7.15) |
857 |
CF18 |
858 |
Displays the sensor flow calibration coefficient CF18
(Fct. C1.7.16) |
859 |
CF19 |
860 |
Displays the sensor flow calibration coefficient CF19
(Fct. C1.7.17) |
861 |
CF20 |
862 |
Displays the sensor flow calibration coefficient CF20
(Fct. C1.7.18) |
863 |
CF21 |
864 |
Displays the sensor flow calibration coefficient CF21
(Fct. C1.7.19) |
865 |
CF22 |
866 |
Displays the sensor flow calibration coefficient CF22
(Fct. C1.7.20) |
867 |
CF23 |
868 |
Displays the sensor flow calibration coefficient CF23
(Fct. C1.7.21) |
869 |
CF24 |
870 |
Displays the sensor flow calibration coefficient CF24
(Fct. C1.7.22) |
871 |
CF25 |
872 |
Displays the sensor flow calibration coefficient CF25
(Fct. C1.7.23) |
873 |
CF26 |
874 |
Displays the sensor flow calibration coefficient CF26
(Fct. C1.7.24) |
875 |
CF27 |
876 |
Displays the sensor flow calibration coefficient CF27
(Fct. C1.7.25) |
877 |
Tube Amplitude |
878 |
Sets the desired amplitude of vibration of the measuring tube(s)
(Fct. D1.4.1) |
879 |
Internal Cutoff |
880 |
Sets the internal low flow cutoff
(Fct. D1.4.3) |
881 |
CF5 Error |
882 |
Sets the internal mass flow correction
(Fct. D1.4.4) |
883 |
Sets the empty density used for density calibration
(Fct. D1.4.5) |
884 |
Time Constant |
885 |
Sets the LP filter duration of the SE board
(Fct. D1.4.6) |
886 |
Min. Freq. |
887 |
Sets the minimum frequency of vibration of the measuring tube(s)
(Fct. D1.4.7) |
888 |
Start Freq. |
889 |
Sets the initial frequency of vibration of the measuring tube(s)
(Fct. D1.4.8) |
890 |
Max. Freq. |
891 |
Sets the maximum frequency of vibration of the measuring tube(s)
(Fct. D1.4.9) |
892 |
Zero Calib. Duration |
893 |
Sets the sample duration used for zero calibration
(Fct. D1.4.10) |
894 |
2 Ph. Threshold |
895 |
Sets the threshold for activation of the 2-phase signal error message
(Fct. C1.5.3) |
896 |
2 Ph. Ref. Level |
897 |
Sets the reference scaling factor for 2-phase flow indication
(Fct. D1.4.11) |
898 |
MthPrepareDownloadToDeviceSpi |
899 |
Select Concentration 1 Function |
900 |
Select Concentration 1 Function.
(Fct. C2.2.1) |
901 |
Select Concentration 2 Function |
902 |
Select Concentration 2 Function.
(Fct. C2.3.1) |
903 |
Select Diagnosis 1 |
904 |
Select diagnosis 1 value
(Fct. C1.5.4) |
905 |
Select Diagnosis 2 |
906 |
Select diagnosis 2 value
(Fct. C1.5.5) |
907 |
Select Diagnosis 3 |
908 |
Select diagnosis 3 value
(Fct. C1.16.3) |
909 |
|
910 |
Passed |
911 |
Failed - not meas. |
912 |
Failed - zero too high |
913 |
AbmLeaveZeroCalibration |
914 |
Performs Zero calibration/Displays current zero calibration value
(Fct. A8, C1.1.1) |
915 |
Calibrate Density |
916 |
Failed - points close |
917 |
Failed - plausibility |
918 |
AbmLeaveDensityCalibration |
919 |
Rec. Temp. Passwd |
920 |
Resets the minimum/maximum recorded temperature values
(Fct. D1.4.12) |
921 |
Process Input |
922 |
Actual Values |
923 |
Zero and Offset |
924 |
Filters |
925 |
System Control |
926 |
Diagnostics |
927 |
Information |
928 |
Flow Calibration |
929 |
Density Calibration |
930 |
Simulation |
931 |
General |
932 |
Configuration |
933 |
Hardware Platform |
934 |
hardware platform
1: Basic IO
2: Modular IO / Exi IO
3: Exi IO + Exi option
4: Fieldbus IO
5: Modular IO + Modular carrier
6: Fieldbus IO + Modular carrier
7: Modular IO + Modular carrier + Current output A
8: Fieldbus IO + Modular carrier + Current output A
9: Modular IO + Modular carrier + Current output B
10: Fieldbus IO + Modular carrier + Current output B
11: Modular IO + Modular carrier + Current output A + Current output B
12: Fieldbus IO + Modular carrier + Current output A + Current output B
13: Fieldbus IO + Exi option |
935 |
1: basic IO |
936 |
2: modular / Exi IO |
937 |
3: ExiIO + Exi opt. |
938 |
4: fieldbus IO |
939 |
5: mod.IO+mod.carr. |
940 |
6: fldb.IO+mod.car. |
941 |
7: mod.IO+mod.c.+A |
942 |
8: fb.IO+mod.C.+A |
943 |
9: mod.IO+mod.c.+B |
944 |
10: fb.IO+mod.c.+B |
945 |
11: mod.IO+mod.c.+A+B |
946 |
12: fb.IO+mod.c.+A+B |
947 |
13: fldb.IO+Exi opt. |
948 |
Communication select |
949 |
Basic IO |
950 |
Mod./Exi IO |
951 |
Profi.DP |
952 |
Profi.PA |
953 |
Foundation H1 |
954 |
Modbus |
955 |
Totalizer select |
956 |
IO2 |
957 |
Display IO |
958 |
Profibus |
959 |
FF |
960 |
Terminals A |
961 |
equipment terminals A
1: current output
4: control input
5: output off
6: pulse-/ frequency-/ status output / limit switch |
962 |
universal |
963 |
1: current output |
964 |
4: control input |
965 |
5: off |
966 |
6: puls/frq/sta /lim |
967 |
Terminals B |
968 |
equipment terminals B
1: current output
3: status output / limit switch + control input
4: control input
5: output off
6: pulse-/ frequency-/ status output / limit switch
7: pulse-/ frequency-/ status output / limit switch + control input |
969 |
3: stat./lim./ctrl |
970 |
7: pu/fr/st/lim+ctrl |
971 |
Terminals C |
972 |
equipment terminals C
1: current output
2: status output / limit switch
5: output off |
973 |
2: status/limit Sw. |
974 |
Terminals D |
975 |
equipment terminals D
5: output off
6: pulse-/ frequency-/ status output / limit switch |
976 |
Sets the output associated with Terminal A
(Fct. C3.1.1) |
977 |
Off |
978 |
Current output |
979 |
Control input |
980 |
Frequency output |
981 |
Pulse output |
982 |
Status output |
983 |
Limit switch |
984 |
Sets the output associated with Terminal B
(Fct. C3.1.2) |
985 |
Sets the output associated with Terminal C
(Fct. C3.1.3) |
986 |
Sets the output associated with Terminal D
(Fct. C3.1.4) |
987 |
Simulation Value |
988 |
6.0f |
989 |
MthPrepareDownloadToDeviceSio |
990 |
MthUpdateInterModuleSio |
991 |
MthOflAlignInterModuleSio |
992 |
Sets simulated output of output A
(Fct. B1.5) |
993 |
Sets simulated output of output B
(Fct. B1.6) |
994 |
Simulation C |
995 |
Sets simulated output of output C
(Fct. B1.7) |
996 |
Sets simulated output of output D
(Fct. B1.8) |
997 |
Information A |
998 |
Displays information of I/O board
(Fct. C3.2.3/4/6/12/13) |
999 |
Information B |
1000 |
Displays information of I/O board
(Fct. C3.3.3/4/6/12/13) |
1001 |
Information C |
1002 |
Displays information of I/O board
(Fct. C3.4.4/6/13) |
1003 |
Information D |
1004 |
Displays information of I/O board
(Fct. C3.5.4/6/12) |
1005 |
Input/Output |
1006 |
I/O |
1007 |
Hardware |
1008 |
I/O Totalisers |
1009 |
Limitation |
1010 |
Range 0%...100% |
1011 |
Extended Range |
1012 |
Error Current |
1013 |
Range |
1014 |
Threshold |
1015 |
Current Test HW |
1016 |
Pulse Width |
1017 |
100% Pulse Rate |
1018 |
Max. Pulse Rate |
1019 |
Value Per Pulse |
1020 |
Status Test |
1021 |
Status A Test |
1022 |
Threshold |
1023 |
Control Test |
1024 |
Control A Test |
1025 |
Limitation Min |
1026 |
Limitation before applying the time constant
(Fct. C3.2.7/8) |
1027 |
4.0f |
1028 |
Limitation Max |
1029 |
Low Flow Cutoff Threshold |
1030 |
Low flow cutoff for current output A
Low flow cutoff for frequency output A
(Fct. C3.2.8/9) |
1031 |
Low Flow Cutoff Hysteresis |
1032 |
Range 0% |
1033 |
Range setting for current output A
(Fct. C3.2.1) |
1034 |
Range 100% |
1035 |
Extended Range Min |
1036 |
Min/Max setting for current output A
(Fct. C3.2.2) |
1037 |
Extended Range Max |
1038 |
Error current setting for current output A
(Fct. C3.2.3) |
1039 |
Range Min |
1040 |
Measurement value range for current output A
Measurement value range for frequency output A
(Fct. C3.2.5/6) |
1041 |
5.1f |
1042 |
Range Max |
1043 |
Time Constant for current output A
(Fct. C3.2.10) |
1044 |
Threshold Range Change |
1045 |
Threshold value for range change setting for current output A
(Fct. C3.2.12) |
1046 |
Hysteresis Range Change |
1047 |
Current A Test HW |
1048 |
ms |
1049 |
Pulse width of frequency output A
(Fct. C3.2.2) |
1050 |
7.2f |
1051 |
Hz |
1052 |
Pulse rate for 100% of measuring range for frequency output A
(Fct. C3.2.3) |
1053 |
6.2f |
1054 |
Time Constant for frequency output A
Time Constant for pulse output A
Time Constant for limit switch A
(Fct. C3.2.4/9) |
1055 |
7.1f |
1056 |
Pulse rate for 100% of measuring range for pulse output A
(Fct. C3.2.3) |
1057 |
Value setting for pulse output A
(Fct. C3.2.6) |
1058 |
Low flow cutoff for pulse output A
(Fct. C3.2.8) |
1059 |
Limit Switch Threshold |
1060 |
Threshold value for limit switch A
(Fct. C3.2.2) |
1061 |
Limit Switch Hysteresis |
1062 |
Error Condition |
1063 |
Sets condition for error current in output A
(Fct. C3.2.4) |
1064 |
Out Of Specification |
1065 |
Measurement |
1066 |
Measurement value for current output A
Measurement value for frequency output A
Measurement for limit switch A
(Fct. C3.2.1/4/5) |
1067 |
Conc. mass flow 1 |
1068 |
Conc. volume flow 1 |
1069 |
Conc. mass flow 2 |
1070 |
Conc. volume flow 2 |
1071 |
Polarity |
1072 |
Sets response of current output A to measurement polarity
Sets response of frequency output A to measurement polarity
Sets response of pulse output A to measurement polarity
Sets response of limit switch A to measurement polarity
(Fct. C3.2.3/6/7) |
1073 |
Both Polarities |
1074 |
Positive Polarity |
1075 |
Negative Polarity |
1076 |
Absolute Value |
1077 |
Special Function |
1078 |
Range change setting for current output A
(Fct. C3.2.11) |
1079 |
Automatic Range |
1080 |
External Range |
1081 |
Pulse Shape |
1082 |
Pulse shape of frequency output A
(Fct. C3.2.1) |
1083 |
Symmetric |
1084 |
Automatic |
1085 |
Invert Signal |
1086 |
Inverts signal at frequency output A
Inverts signal at pulse output A
Inverts signal at status output A
(Fct. C3.2.3/10) |
1087 |
Phase Shift w.r.t. B |
1088 |
Phase shift relative to frequency output B
Phase shift relative to pulse output B
(Fct. C3.2.11) |
1089 |
0° Phase Shift |
1090 |
90° Phase Shift |
1091 |
180° Phase Shift |
1092 |
Measurement for pulse output A
(Fct. C3.2.4) |
1093 |
Mode |
1094 |
Measurement for status output A
(Fct. C3.2.1) |
1095 |
Flow Polarity |
1096 |
Flow Over Range |
1097 |
Totaliser 1 Preset |
1098 |
Totaliser 2 Preset |
1099 |
Output B |
1100 |
Output C |
1101 |
Output D |
1102 |
Totaliser 3 Preset |
1103 |
Function Statusoutput |
1104 |
Condition to activate status output A
(Fct. C3.2.2) |
1105 |
Status Off |
1106 |
Polarity |
1107 |
Over Range |
1108 |
Range Change B |
1109 |
Same Signal |
1110 |
Range Change C |
1111 |
Inverts signal at limit switch A
(Fct. C3.2.5) |
1112 |
Action for control input A
(Fct. C3.2.1) |
1113 |
Hold All Outputs |
1114 |
Hold Output B |
1115 |
Hold Output C |
1116 |
Hold Output D |
1117 |
All Outputs To Zero |
1118 |
Output B To Zero |
1119 |
Output C To Zero |
1120 |
Output D To Zero |
1121 |
Reset All Totalisers |
1122 |
Reset Totaliser 1 |
1123 |
Reset Totaliser 2 |
1124 |
Stop All Totalisers |
1125 |
Stop Totaliser 1 |
1126 |
Stop Totaliser 2 |
1127 |
Zero Outp.+Stop Tot. |
1128 |
Error Reset |
1129 |
Inverts signal at control input A
(Fct. C3.2.2) |
1130 |
Range units A |
1131 |
m/s |
1132 |
ft/s |
1133 |
L/s |
1134 |
L/min |
1135 |
L/h |
1136 |
m³/s |
1137 |
m³/min |
1138 |
m³/h |
1139 |
cf/s |
1140 |
cf/min |
1141 |
cf/h |
1142 |
gal/s |
1143 |
gal/min |
1144 |
gal/h |
1145 |
IG/s |
1146 |
IG/min |
1147 |
IG/h |
1148 |
barrel/h |
1149 |
barrel/day |
1150 |
g/s |
1151 |
g/min |
1152 |
g/h |
1153 |
kg/s |
1154 |
kg/min |
1155 |
kg/h |
1156 |
t/min |
1157 |
t/h |
1158 |
lb/s |
1159 |
lb/min |
1160 |
lb/h |
1161 |
ST/min |
1162 |
ST/h |
1163 |
LT/h |
1164 |
°C |
1165 |
°F |
1166 |
K |
1167 |
kg/m³ |
1168 |
kg/L |
1169 |
lb/cf |
1170 |
lb/gal |
1171 |
SG |
1172 |
Pulse Value Unit A |
1173 |
Unit for pulse output
Unit for pulse output A
(Fct. A5.2, C3.2.5, C3.3.5, C3.5.5) |
1174 |
ml |
1175 |
L |
1176 |
hl |
1177 |
m³ |
1178 |
in³ |
1179 |
cf |
1180 |
yd³ |
1181 |
gal |
1182 |
IG |
1183 |
barrel |
1184 |
g |
1185 |
kg |
1186 |
t |
1187 |
oz |
1188 |
lb |
1189 |
ST |
1190 |
LT |
1191 |
LFC Pulse Units A |
1192 |
Unit Limit Switch |
1193 |
MthUpdateRangeIoX |
1194 |
MthOflAlignUnitsRangeIoX |
1195 |
MthUpdatePulseVauleX |
1196 |
MthOflAlignUnitsPulseValueX |
1197 |
MthUpdateLfcAbsoluteIoX |
1198 |
MthOflAlignUnitsLfcAbsoluteIoX |
1199 |
MthUpdateThresholdLimitSwitchX |
1200 |
MthOflAlignUnitsThresholdLimitSwitchX |
1201 |
Sets simulated output of current output A
(Fct. C3.2.14) |
1202 |
Sets simulated output of frequency output A
(Fct. C3.2.13) |
1203 |
Sets simulated output of pulse output A
(Fct. C3.2.13) |
1204 |
Sets simulated output of status output A
(Fct. C3.2.5) |
1205 |
Sets simulated output of status output A
Sets simulated output of limit switch A
(Fct. C3.2.5/7) |
1206 |
Sets simulated output of control input A
(Fct. C3.2.4) |
1207 |
A (off) |
1208 |
A |
1209 |
Current Output A |
1210 |
Frequency Output A |
1211 |
Pulse Output A |
1212 |
Status Output A |
1213 |
Limit Switch A |
1214 |
Control Input A |
1215 |
Status B Test |
1216 |
Control B Test |
1217 |
Limitation before applying the time constant
(Fct. C3.3.7/8) |
1218 |
Low flow cutoff for current output B
Low flow cutoff for frequency output B
(Fct. C3.3.8/9) |
1219 |
Range setting for current output B
(Fct. C3.3.1) |
1220 |
Min/Max setting for current output B
(Fct. C3.3.2) |
1221 |
Error current setting for current output B
(Fct. C3.3.3) |
1222 |
Measurement value range for current output B
Measurement value range for frequency output B
(Fct. C3.3.5/6) |
1223 |
Time Constant for current output B
(Fct. C3.3.10) |
1224 |
Threshold value for range change setting for current output B
(Fct. C3.3.12) |
1225 |
Current B Test HW |
1226 |
Pulse width of frequency output B
(Fct. C3.3.2) |
1227 |
Pulse rate for 100% of measuring range for frequency output B
(Fct. C3.3.3) |
1228 |
Time Constant for frequency output B
Time Constant for pulse output B
Time Constant for limit switch B
(Fct. C3.3.4/9) |
1229 |
Pulse rate for 100% of measuring range for pulse output B
(Fct. C3.3.3) |
1230 |
Value setting for pulse output B
(Fct. C3.3.6) |
1231 |
Low flow cutoff for pulse output B
(Fct. C3.3.8) |
1232 |
Threshold value for limit switch B
(Fct. C3.3.2) |
1233 |
Sets condition for error current in output B
(Fct. C3.3.4) |
1234 |
Measurement value for current output B
Measurement value for frequency output B
Measurement for limit switch B
(Fct. C3.3.1/4/5) |
1235 |
Sets response of current output B to measurement polarity
Sets response of frequency output B to measurement polarity
Sets response of pulse output B to measurement polarity
Sets response of limit switch B to measurement polarity
(Fct. C3.3.3/6/7) |
1236 |
Range change setting for current output B
(Fct. C3.3.11) |
1237 |
Pulse shape of frequency output B
(Fct. C3.3.1) |
1238 |
Inverts signal at frequency output B
Inverts signal at pulse output B
Inverts signal at status output B
(Fct. C3.3.3/10) |
1239 |
Measurement for pulse output B
(Fct. C3.3.4) |
1240 |
Measurement for status output B
(Fct. C3.3.1) |
1241 |
Output A |
1242 |
Condition to activate status output B
(Fct. C3.3.2) |
1243 |
Range Change A |
1244 |
Inverts signal at limit switch B
(Fct. C3.3.5) |
1245 |
Action for control input B
(Fct. C3.3.1) |
1246 |
Hold Output A |
1247 |
Output A To Zero |
1248 |
Inverts signal at control input B
(Fct. C3.3.2) |
1249 |
Phase shift relative to frequency output A or D
Phase shift relative to pulse output A or D
(Fct. C3.3.11) |
1250 |
Phase Shift w.r.t. D |
1251 |
Phase Shift w.r.t. A |
1252 |
Range units B |
1253 |
Pulse Value Unit B |
1254 |
Unit for pulse output
Unit for pulse output B
Unit for pulse output D
(Fct. A5.2, C3.2.5, C3.3.5, C3.5.5) |
1255 |
LFC Pulse Units B |
1256 |
Sets simulated output of current output B
(Fct. C3.3.14) |
1257 |
Sets simulated output of frequency output B
(Fct. C3.3.13) |
1258 |
Sets simulated output of pulse output B
(Fct. C3.3.13) |
1259 |
Sets simulated output of status output B
Sets simulated output of limit switch B
(Fct. C3.3.5/7) |
1260 |
Sets simulated output of control input B
(Fct. C3.3.4) |
1261 |
B (off) |
1262 |
B |
1263 |
Current Output B |
1264 |
Frequency Output B |
1265 |
Pulse Output B |
1266 |
Status Output B |
1267 |
Limit Switch B |
1268 |
Control Input B |
1269 |
Status C Test |
1270 |
Limitation before applying the time constant
(Fct. C3.4.8) |
1271 |
Low flow cutoff for current output C
(Fct. C3.4.9) |
1272 |
Range setting for current output C
(Fct. C3.4.1) |
1273 |
Extended Range
(Fct. C3.4.2) |
1274 |
Error current setting for current output C
(Fct. C3.4.3) |
1275 |
Measurement value range for current output C
(Fct. C3.4.6) |
1276 |
Time Constant for current output C
(Fct. C3.4.10) |
1277 |
Threshold value for range change setting for current output C
(Fct. C3.4.12) |
1278 |
Current C Test HW |
1279 |
Time Constant for limit switch C
(Fct. C3.4.4) |
1280 |
Threshold value for limit switch C
(Fct. C3.4.2) |
1281 |
Sets condition for error current in output C
(Fct. C3.4.4) |
1282 |
Measurement value for current output C
Measurement for limit switch C
(Fct. C3.4.1/5) |
1283 |
Sets response of current output C to measurement polarity
Sets response of limit switch C to measurement polarity
(Fct. C3.4.3/7) |
1284 |
Range change setting for current output C
(Fct. C3.4.11) |
1285 |
Inverts signal at status output C
(Fct. C3.4.3) |
1286 |
Measurement for status output C
(Fct. C3.4.1) |
1287 |
Condition to activate status output C
(Fct. C3.4.2) |
1288 |
Inverts signal at limit switch C
(Fct. C3.4.5) |
1289 |
Range units C |
1290 |
Sets simulated output of current output C
(Fct. C3.4.14) |
1291 |
Sets simulated output of status output C
Sets simulated output of limit switch C
(Fct. C3.4.5/7) |
1292 |
C (off) |
1293 |
C |
1294 |
Current Output C |
1295 |
Status Output C |
1296 |
Limit Switch C |
1297 |
Status D Test |
1298 |
Limitation before applying the time constant
(Fct. C3.5.7) |
1299 |
Low flow cutoff for frequency output D
(Fct. C3.5.8) |
1300 |
Measurement value range for frequency output D
(Fct. C3.5.5) |
1301 |
Pulse width of frequency output D
(Fct. C3.5.2) |
1302 |
Pulse rate for 100% of measuring range for frequency output D
(Fct. C3.5.3) |
1303 |
Time Constant for frequency output D
Time Constant for pulse output D
Time Constant for limit switch D
(Fct. C3.5.4/9) |
1304 |
Pulse rate for 100% of measuring range for pulse output D
(Fct. C3.5.3) |
1305 |
Value setting for pulse output D
(Fct. C3.5.6) |
1306 |
Low flow cutoff for pulse output D
(Fct. C3.5.8) |
1307 |
Threshold value for limit switch D
(Fct. C3.5.2) |
1308 |
Measurement value for frequency output D
Measurement for limit switch D
(Fct. C3.5.1/4) |
1309 |
Sets response of frequency output D to measurement polarity
Sets response of pulse output D to measurement polarity
Sets response of limit switch D to measurement polarity
(Fct. C3.5.3/6/7) |
1310 |
Pulse shape of frequency output D
(Fct. C3.5.1) |
1311 |
Inverts signal at frequency output D
Inverts signal at pulse output B
Inverts signal at status output D
(Fct. C3.5.3/10) |
1312 |
Phase shift relative to frequency output D
Phase shift relative to pulse output D
(Fct. C3.5.11) |
1313 |
Measurement for pulse output D
(Fct. C3.5.4) |
1314 |
Measurement for status output D
(Fct. C3.5.1) |
1315 |
Condition to activate status output D
(Fct. C3.5.2) |
1316 |
Inverts signal at limit switch D
(Fct. C3.5.5) |
1317 |
Range units D |
1318 |
Pulse Value Unit D |
1319 |
LFC Pulse Units D |
1320 |
Sets simulated output of frequency output D
(Fct. C3.5.13) |
1321 |
Sets simulated output of pulse output D
(Fct. C3.5.13) |
1322 |
Sets simulated output of status output D
Sets simulated output of limit switch D
(Fct. C3.5.5/7) |
1323 |
D (off) |
1324 |
D |
1325 |
Frequency Output D |
1326 |
Pulse Output D |
1327 |
Status Output D |
1328 |
Limit Switch D |
1329 |
Preset Value |
1330 |
Totaliser 1 |
1331 |
Totlaiser 1 |
1332 |
Low Flow Cutoff Threshold |
1333 |
Low flow cutoff for totaliser 1
(Fct. C4.1.3) |
1334 |
Low Flow Cutoff Hysteresis |
1335 |
Time Constant for totaliser 1
(Fct. C4.1.4) |
1336 |
Preset value for totaliser 1
(Fct. C4.1.5) |
1337 |
Totaliser Function |
1338 |
Function for totaliser 1
(Fct. C4.1.1) |
1339 |
Absolute Total |
1340 |
Incremental Total |
1341 |
Decremental Total |
1342 |
Measurement.
The setting should be changed with the corresponding online-method only, as dependent units need to be updated.
(Fct. C4.1.2) |
1343 |
LFC Totaliser Unit 1 |
1344 |
Preset Value Unit 1 |
1345 |
uniTotalizerResetX |
1346 |
MthUpdateLFCTotalizerX |
1347 |
MthOflAlignUnitsLFCTotalizerX |
1348 |
MthUpdatePresetValueTotalizerX |
1349 |
MthOflAlignUnitsPresetValueTotalizerX |
1350 |
Reset Totaliser 1 |
1351 |
Resets totaliser 1
(Fct. C4.1.6) |
1352 |
Set Totaliser |
1353 |
Sets totaliser 1 to desired value
(Fct. C4.1.7) |
1354 |
Stop Totaliser |
1355 |
Stops totaliser 1 and holds current value
(Fct. C4.1.8) |
1356 |
Start Totaliser |
1357 |
Starts totaliser 1 after it has been stopped
(Fct. C4.1.9) |
1358 |
Set Measurement |
1359 |
Measurement for totaliser 1
(Fct. C4.1.2) |
1360 |
Displays information of totaliser 1
(Fct. C4.1.10) |
1361 |
Totlaiser 2 |
1362 |
Low flow cutoff for totaliser 2
(Fct. C4.2.3) |
1363 |
Time Constant for totaliser 2
(Fct. C4.2.4) |
1364 |
Preset value for totaliser 2
(Fct. C4.2.5) |
1365 |
Function for totaliser 2
(Fct. C4.2.1) |
1366 |
Measurement.
The setting should be changed with the corresponding online-method only, as dependent units need to be updated.
(Fct. C4.2.2) |
1367 |
LFC Totaliser Unit 2 |
1368 |
Preset Value Unit 2 |
1369 |
Reset Totaliser 2 |
1370 |
Resets totaliser 2
(Fct. C4.2.6) |
1371 |
Sets totaliser 2 to desired value
(Fct. C4.2.7) |
1372 |
Stops totaliser 2 and holds current value
(Fct. C4.2.8) |
1373 |
Starts totaliser 2 after it has been stopped
(Fct. C4.2.9) |
1374 |
Measurement for totaliser 2
(Fct. C4.2.2) |
1375 |
Displays information of totaliser 2
(Fct. C4.2.10) |
1376 |
Totaliser 2 |
1377 |
Totlaiser 3 |
1378 |
Low flow cutoff for totaliser 3
(Fct. C4.3.3) |
1379 |
Time Constant for totaliser 3
(Fct. C4.3.4) |
1380 |
Preset value for totaliser 3
(Fct. C4.3.5) |
1381 |
Function for totaliser 3
(Fct. C4.3.1) |
1382 |
Measurement.
The setting should be changed with the corresponding online-method only, as dependent units need to be updated.
(Fct. C4.3.2) |
1383 |
LFC Totaliser Unit 3 |
1384 |
Preset Value Unit 3 |
1385 |
Reset Totaliser 3 |
1386 |
Resets totaliser 3
(Fct. C4.3.6) |
1387 |
Sets totaliser 3 to desired value
(Fct. C4.3.7) |
1388 |
Stops totaliser 3 and holds current value
(Fct. C4.3.8) |
1389 |
Starts totaliser 3 after it has been stopped
(Fct. C4.3.9) |
1390 |
Measurement for totaliser 3
(Fct. C4.3.2) |
1391 |
Displays information of totaliser 3
(Fct. C4.3.10) |
1392 |
Totaliser 3 |
1393 |
Service Calibration |
1394 |
units |
1395 |
Custody transfer |
1396 |
Access Level HART |
1397 |
Authorization level for data access via the HART interface. |
1398 |
Standard (1) |
1399 |
Extended (2) |
1400 |
Service (3) |
1401 |
Password |
1402 |
Password for changing the authorization level for data access via the HART interface. |
1403 |
4u |
1404 |
Custody Lock |
1405 |
If Custody Lock is activated, certain configuration parameters are write protected. |
1406 |
off |
1407 |
on |
1408 |
Sensor Type |
1409 |
Displays the sensor type
(Fct. C1.6.1) |
1410 |
1st Line Format |
1411 |
No. of decimal places for 1st line of 1st Measuring page
(Fct. C6.3.7) |
1412 |
#X. |
1413 |
#X.X |
1414 |
#X.XX |
1415 |
#X.XXX |
1416 |
#X.XXXX |
1417 |
#X.XXXXX |
1418 |
#X.XXXXXX |
1419 |
#X.XXXXXXX |
1420 |
#X.XXXXXXXX |
1421 |
No. of decimal places for 1st line of 2nd Measuring page
(Fct. C6.4.7) |
1422 |
Time Scale |
1423 |
unit % |
1424 |
Auxiliary variable |
1425 |
unit Hz |
1426 |
unit ohm |
1427 |
unit mA |
1428 |
unit min |
1429 |
unit ms |
1430 |
HART
(Fct. C6.8.1) |
1431 |
HART Off |
1432 |
HART On |
1433 |
Unit not used |
1434 |
Unit s |
1435 |
Language |
1436 |
Language selection depends on the device version.
Languauge selection
(Fct. A1, C6.2.1) |
1437 |
English |
1438 |
Slovenian |
1439 |
reserved |
1440 |
Dansk |
1441 |
Polski |
1442 |
Deutsch |
1443 |
Français |
1444 |
chinese |
1445 |
japanese |
1446 |
¨ðÈ¡ ðÀÀÀà¼ÀðÂÀÈà ´ÀüþðÇÁ Ìø |
1447 |
Español |
1448 |
Svenska |
1449 |
Português |
1450 |
Nederlands |
1451 |
italiano |
1452 |
Select Range |
1453 |
Range setting for graphic page
(Fct. C6.5.1) |
1454 |
Manual |
1455 |
Automatic |
1456 |
Scaling for graphic page Y-axis
(Fct. C6.5.2) |
1457 |
3.0f |
1458 |
Range +/- |
1459 |
Time scale for graphic page X-axis
(Fct. C6.5.3) |
1460 |
Operating Hours |
1461 |
Displays device operating hours
(Fct. B2.1) |
1462 |
[m³]*Factor |
1463 |
Sets free unit factor for Volume
(Fct. C6.7.12) |
1464 |
Text Free Unit |
1465 |
Sets free unit text for Volume
(Fct. C6.7.11) |
1466 |
hl |
1467 |
[kg]*Factor |
1468 |
Sets free unit factor for Mass
(Fct. C6.7.15) |
1469 |
Sets free unit text for Mass
(Fct. C6.7.14) |
1470 |
kg |
1471 |
[m³/s]*Factor |
1472 |
Sets free unit factor for Volume Flow
(Fct. C6.7.3) |
1473 |
Sets free unit text for Volume Flow
(Fct. C6.7.2) |
1474 |
hl / s |
1475 |
[kg/s]*Factor |
1476 |
Sets free unit factor for Mass Flow
(Fct. C6.7.6) |
1477 |
Sets free unit text for Mass Flow
(Fct. C6.7.5) |
1478 |
kg / s |
1479 |
[kg/m³]*Factor |
1480 |
Sets free unit factor for Density
(Fct. C6.7.18) |
1481 |
Sets free unit text for Density
(Fct. C6.7.17) |
1482 |
kg / m³ |
1483 |
Sensor Serial No. |
1484 |
Displays the serial number of the measuring sensor
(Fct. C1.6.8, C6.1.3) |
1485 |
Converter Serial No. |
1486 |
Displays the serial number of the converter
(Fct. C6.1.6) |
1487 |
Electronics Serial No. |
1488 |
Displays the serial number of the electronics
(Fct. C6.1.8) |
1489 |
C Number |
1490 |
Displays the C number of the installed electronics
Displays the CG number of the installed electronics
(Fct. B3.3, C6.1.7) |
1491 |
Detected C-No. |
1492 |
Automatically detected C-number
(Fct. D2.3.1) |
1493 |
uiCNumberDetectedDigit01 |
1494 |
uiCNumberDetectedDigit02 |
1495 |
uiCNumberDetectedDigit03 |
1496 |
uiCNumberDetectedDigit04 |
1497 |
uiCNumberDetectedDigit05 |
1498 |
uiCNumberDetectedDigit06 |
1499 |
uiCNumberDetectedDigit07 |
1500 |
C-Number (8th Position) |
1501 |
8th position of the C-number |
1502 |
0 |
1503 |
1 |
1504 |
2 |
1505 |
3 |
1506 |
4 |
1507 |
5 |
1508 |
6 |
1509 |
7 |
1510 |
8 |
1511 |
9 |
1512 |
E |
1513 |
F |
1514 |
uiCNumberDetectedDigit09 |
1515 |
uiCNumberDetectedDigit10 |
1516 |
V No. Sensor |
1517 |
Displays the order number of the measuring sensor
(Fct. C1.6.7, C6.1.2) |
1518 |
V No. Converter |
1519 |
Displays the order number of the converter
(Fct. C1.6.9, C6.1.5) |
1520 |
Sensor Revision |
1521 |
Displays information of the Sensor Revision
Displays the revision number of the measuring sensor
(Fct. B3.7, C6.1.4) |
1522 |
unit h |
1523 |
Pulse Value Unit (Mass) |
1524 |
A5.2, C3.2.5, C3.3.5, C3.5.5 |
1525 |
Pulse Value Unit (Volume) |
1526 |
Sets displayed units for Density
(Fct. C6.7.16) |
1527 |
Volume |
1528 |
Sets displayed units for Volume
(Fct. C6.7.10) |
1529 |
Mass |
1530 |
Sets displayed units for Mass
(Fct. C6.7.13) |
1531 |
Sets displayed units for Flow Velocity
(Fct. C6.7.7) |
1532 |
Sets displayed units for Volume Flow
(Fct. C6.7.1) |
1533 |
Sets displayed units for Mass Flow
(Fct. C6.7.4) |
1534 |
Sets displayed units for Temperature
(Fct. C6.7.9) |
1535 |
Min/Max setting for 1st line of 1st Measuring page
(Fct. C6.3.4) |
1536 |
Time Constant for 1st line of 1st Measuring page
(Fct. C6.3.6) |
1537 |
Low flow cutoff for 1st line of 1st Measuring page
(Fct. C6.3.5) |
1538 |
Sets number of lines of display on 1st Measuring page
(Fct. C6.3.1) |
1539 |
One Line |
1540 |
Two Lines |
1541 |
Three Lines |
1542 |
2nd Line Format |
1543 |
No. of decimal places for 2nd line of 1st Measuring page
No. of decimal places for 2nd line of 2ndMeasuring page
(Fct. C6.3.9, C6.4.9) |
1544 |
3rd Line Format |
1545 |
No. of decimal places for 3rd line of 1st Measuring page
(Fct. C6.3.11) |
1546 |
Min/Max setting for 1st line of 2nd Measuring page
(Fct. C6.4.4) |
1547 |
Time Constant for 1st line of 2nd Measuring page
(Fct. C6.4.6) |
1548 |
Low flow cutoff for 1st line of 2nd Measuring page
(Fct. C6.4.5) |
1549 |
Sets number of lines of display on 2nd Measuring page
(Fct. C6.4.1) |
1550 |
No. of decimal places for 2nd line of 2ndMeasuring page
(Fct. C6.4.4/9) |
1551 |
No. of decimal places for 3rd line of 2nd Measuring page
(Fct. C6.4.6/11) |
1552 |
Default Display |
1553 |
Sets default page of display on reset
(Fct. C6.2.3) |
1554 |
None |
1555 |
1st Meas. Page |
1556 |
2nd Meas. Page |
1557 |
Status Page |
1558 |
Graphic Page |
1559 |
Optical Keys |
1560 |
Turns optical keys on/off
(Fct. C6.2.4) |
1561 |
Language group select |
1562 |
Eastern Europe |
1563 |
Northern Europe |
1564 |
Southern Europe |
1565 |
Far East |
1566 |
Graphical |
1567 |
OEM |
1568 |
unit mm |
1569 |
mm |
1570 |
1st Line Variable |
1571 |
Measurement for 1st line of 1st Measuring page
(Fct. C6.3.2) |
1572 |
Range unit page 1 |
1573 |
Range unit measurement page 1 |
1574 |
Range 100% |
1575 |
Range setting for 1st line of 1st Measuring page
(Fct. C6.3.3) |
1576 |
Range 0% |
1577 |
2nd Line Variable |
1578 |
Measurement for 2nd line of 1st Measuring page
(Fct. C6.3.8) |
1579 |
Totaliser 1 Mass |
1580 |
Totaliser 1 Volume |
1581 |
Totaliser 2 Mass |
1582 |
Totaliser 2 Volume |
1583 |
Bargraph |
1584 |
Totaliser 3 Mass |
1585 |
Totaliser 3 Volume |
1586 |
3rd Line Variable |
1587 |
Measurement for 3rd line of 1st Measuring page
(Fct. C6.3.10) |
1588 |
MthUpdateUnitsAndRangesDisplayPageX |
1589 |
MthOflAlignUnitsDisplayPageX |
1590 |
Measurement for 1st line of 2nd Measuring page
(Fct. C6.4.2) |
1591 |
Range unit page 2 |
1592 |
Range unit measurement page 2 |
1593 |
Range setting for 1st line of 2nd Measuring page
(Fct. C6.4.3) |
1594 |
Measurement for 2nd line of 2nd Measuring page
(Fct. C6.4.8) |
1595 |
Measurement for 3rd line of 2nd Measuring page
(Fct. C6.4.10) |
1596 |
MthUpdateInterModuleSdev |
1597 |
MthOflAlignInterModuleSdev |
1598 |
Circuit Board Info |
1599 |
Displays circuit board information. I.e. Identnumber, Hardware ID, Software Version, Production Date, Calibration Date, Board Serial Number. |
1600 |
Main SW Version |
1601 |
Displays main SW version of electronics
(Fct. D2.3.3) |
1602 |
UI SW Version |
1603 |
Displays UI SW version of electronics
(Fct. D2.3.4) |
1604 |
Sensor Electronics |
1605 |
Displays information of the sensor electronics PCB
Displays the serial number of the converter
(Fct. B3.4, C1.6.10) |
1606 |
Electronic Revision |
1607 |
Displays information of the Electronics Revision
Displays the Electronics Revision of the electronics
(Fct. B3.6, C6.1.9) |
1608 |
Reset Errors |
1609 |
Reset Errors
Resets errors
(Fct. A3.1, C6.6.1) |
1610 |
Warmstart |
1611 |
Perform a "warm start". |
1612 |
Read GDC Object |
1613 |
Generic method for reading a GDC object |
1614 |
Write GDC Object |
1615 |
Generic method for writing a GDC object |
1616 |
Enable Service Access |
1617 |
Enabling service parameter access via HART for 20 min.
I.e. Setting the authorization level to Service (3). |
1618 |
Disable Service Access |
1619 |
Disabling service parameter access via HART.
I.e. Resetting the authorization level to Standard (1). |
1620 |
Test/Reset |
1621 |
Device |
1622 |
Device Info |
1623 |
Device Information
(Fct. C6.1) |
1624 |
Display |
1625 |
Display
(Fct. C6.2) |
1626 |
1st Measure Page
(Fct. C6.3) |
1627 |
1. Measurement Page |
1628 |
2nd Measure Page
2nd Measure Page (Profibus)
(Fct. C6.4) |
1629 |
2. Measurement Page |
1630 |
Graphic Page
(Fct. C6.5) |
1631 |
Graphic Page |
1632 |
Special Functions |
1633 |
Special Functions
(Fct. C6.6) |
1634 |
Units |
1635 |
Units
(Fct. C6.7) |
1636 |
Auxiliary Units |
1637 |
Service Access |
1638 |
Service Param. |
1639 |
Service Info |
1640 |
ui16ObjectNumberGdcDelayed |
1641 |
ui16ObjectNumberGdcGeneric |
1642 |
uiSubNumberGdcDelayed |
1643 |
uiSubNumberGdcGeneric |
1644 |
flResponseTimeGdcDelayed |
1645 |
uniPlaceholderGdc |
1646 |
uiCountBytesGdcTg |
1647 |
uiSubNumberGdcTg |
1648 |
ui16ObjectNumberGdcTg |
1649 |
uiControlStatusGdcTg |
1650 |
C number undefined |
1651 |
Waiting for GDC delayed response |
1652 |
uiGdcDelayed1 |
1653 |
uiGdcDelayed2 |
1654 |
uiGdcDelayed3 |
1655 |
uiGdcDelayed4 |
1656 |
uiGdcDelayed5 |
1657 |
uiGdcDelayed6 |
1658 |
uiGdcDelayed7 |
1659 |
uiGdcDelayed8 |
1660 |
uiGdcDelayed9 |
1661 |
uiGdcDelayed10 |
1662 |
uiGdcDelayed11 |
1663 |
uiGdcDelayed12 |
1664 |
uiGdcDelayed13 |
1665 |
uiGdcDelayed14 |
1666 |
uiGdcDelayed15 |
1667 |
uiGdcDelayed16 |
1668 |
uiGdcDelayed17 |
1669 |
uiGdcDelayed18 |
1670 |
uiGdcDelayed19 |
1671 |
uiGdcDelayed20 |
1672 |
ui16GdcDelayedWord1 |
1673 |
ui16GdcDelayedWord2 |
1674 |
ui16GdcDelayedWord3 |
1675 |
ui16GdcDelayedWord4 |
1676 |
ui16GdcDelayedWord5 |
1677 |
ui16GdcDelayedWord6 |
1678 |
ui16GdcDelayedWord7 |
1679 |
ui16GdcDelayedWord8 |
1680 |
ui16GdcDelayedWord9 |
1681 |
ui16GdcDelayedWord10 |
1682 |
flGdcDelayed1 |
1683 |
flGdcDelayed2 |
1684 |
flGdcDelayed3 |
1685 |
flGdcDelayed4 |
1686 |
flGdcDelayed5 |
1687 |
uiGdcByteGenericRead1 |
1688 |
uiGdcByteGenericRead2 |
1689 |
uiGdcByteGenericRead3 |
1690 |
uiGdcByteGenericRead4 |
1691 |
uiGdcByteGenericRead5 |
1692 |
uiGdcByteGenericRead6 |
1693 |
uiGdcByteGenericRead7 |
1694 |
uiGdcByteGenericRead8 |
1695 |
uiGdcByteGenericRead9 |
1696 |
uiGdcByteGenericRead10 |
1697 |
uiGdcByteGenericRead11 |
1698 |
uiGdcByteGenericRead12 |
1699 |
uiGdcByteGenericRead13 |
1700 |
uiGdcByteGenericRead14 |
1701 |
uiGdcByteGenericRead15 |
1702 |
uiGdcByteGenericRead16 |
1703 |
uiGdcByteGenericRead17 |
1704 |
uiGdcByteGenericRead18 |
1705 |
uiGdcByteGenericRead19 |
1706 |
uiGdcByteGenericRead20 |
1707 |
uiGdcByteGenericRead21 |
1708 |
uiGdcByteGenericRead22 |
1709 |
uiGdcByteGenericRead23 |
1710 |
uiGdcByteGenericRead24 |
1711 |
uiGdcByteGenericRead25 |
1712 |
uiGdcByteGenericRead26 |
1713 |
uiGdcByteGenericRead27 |
1714 |
uiGdcByteGenericRead28 |
1715 |
uiGdcByteGenericRead29 |
1716 |
uiGdcByteGenericRead30 |
1717 |
uiGdcByteGenericWrite1 |
1718 |
uiGdcByteGenericWrite2 |
1719 |
uiGdcByteGenericWrite3 |
1720 |
uiGdcByteGenericWrite4 |
1721 |
uiGdcByteGenericWrite5 |
1722 |
uiGdcByteGenericWrite6 |
1723 |
uiGdcByteGenericWrite7 |
1724 |
uiGdcByteGenericWrite8 |
1725 |
uiGdcByteGenericWrite9 |
1726 |
uiGdcByteGenericWrite10 |
1727 |
uiGdcByteGenericWrite11 |
1728 |
uiGdcByteGenericWrite12 |
1729 |
uiGdcByteGenericWrite13 |
1730 |
uiGdcByteGenericWrite14 |
1731 |
uiGdcByteGenericWrite15 |
1732 |
uiGdcByteGenericWrite16 |
1733 |
uiGdcByteGenericWrite17 |
1734 |
uiGdcByteGenericWrite18 |
1735 |
uiGdcByteGenericWrite19 |
1736 |
uiGdcByteGenericWrite20 |
1737 |
uiGdcByteGenericWrite21 |
1738 |
uiGdcByteGenericWrite22 |
1739 |
uiGdcByteGenericWrite23 |
1740 |
uiGdcByteGenericWrite24 |
1741 |
uiGdcByteGenericWrite25 |
1742 |
uiGdcByteGenericWrite26 |
1743 |
uiGdcByteGenericWrite27 |
1744 |
uiGdcByteGenericWrite28 |
1745 |
uiGdcByteGenericWrite29 |
1746 |
uiGdcByteGenericWrite30 |
1747 |
ui16GdcWordGenericRead1 |
1748 |
ui16GdcWordGenericRead2 |
1749 |
ui16GdcWordGenericRead3 |
1750 |
ui16GdcWordGenericRead4 |
1751 |
ui16GdcWordGenericRead5 |
1752 |
ui16GdcWordGenericRead6 |
1753 |
ui16GdcWordGenericRead7 |
1754 |
ui16GdcWordGenericRead8 |
1755 |
ui16GdcWordGenericRead9 |
1756 |
ui16GdcWordGenericRead10 |
1757 |
ui16GdcWordGenericWrite1 |
1758 |
ui16GdcWordGenericWrite2 |
1759 |
ui16GdcWordGenericWrite3 |
1760 |
ui16GdcWordGenericWrite4 |
1761 |
ui16GdcWordGenericWrite5 |
1762 |
ui16GdcWordGenericWrite6 |
1763 |
ui16GdcWordGenericWrite7 |
1764 |
ui16GdcWordGenericWrite8 |
1765 |
ui16GdcWordGenericWrite9 |
1766 |
flGdcFloatGenericRead1 |
1767 |
flGdcFloatGenericRead2 |
1768 |
flGdcFloatGenericRead3 |
1769 |
flGdcFloatGenericRead4 |
1770 |
flGdcFloatGenericRead5 |
1771 |
flGdcFloatGenericWrite1 |
1772 |
flGdcFloatGenericWrite2 |
1773 |
flGdcFloatGenericWrite3 |
1774 |
flGdcFloatGenericWrite4 |
1775 |
ui32GdcUlongGenericRead1 |
1776 |
ui32GdcUlongGenericRead2 |
1777 |
ui32GdcUlongGenericRead3 |
1778 |
ui32GdcUlongGenericRead4 |
1779 |
ui32GdcUlongGenericRead5 |
1780 |
ui32GdcUlongGenericWrite1 |
1781 |
ui32GdcUlongGenericWrite2 |
1782 |
ui32GdcUlongGenericWrite3 |
1783 |
ui32GdcUlongGenericWrite4 |
1784 |
Data type |
1785 |
Byte |
1786 |
Word |
1787 |
Float |
1788 |
Unsigned Long |
1789 |
Invalid password |
1790 |
Invalid object number |
1791 |
Select module |
1792 |
Current output A |
1793 |
Current output B |
1794 |
Current output C |
1795 |
IO 2 |
1796 |
Current input A |
1797 |
Current input B |
1798 |
Ident no. |
1799 |
Hardware id |
1800 |
Software version |
1801 |
Production date |
1802 |
Calibration date |
1803 |
Board ser.no. |
1804 |
Function switched off |
1805 |
No valid items |
1806 |
This menu contains no valid items. |
1807 |
<Image> Manufacturer |
1808 |
<Image> Device |
1809 |
<Image> Process Input Orientation |
1810 |
<Image> Sensor Orientation |
1811 |
<Image> PI Calibration Orientation |
1812 |
<Image> PI Filter Orientation |
1813 |
<Image> PI Selftest Orientation |
1814 |
<Image> Current Output Orientation |
1815 |
<Image> Frequency Output Orientation |
1816 |
<Image> Status Output Orientation |
1817 |
<Image> Control Input Orientation |
1818 |
<Image> Totalizer Orientation |
1819 |
<Image> Selection IO Orientation |
1820 |
<Image> Display Orientation |
1821 |
<Image> HART Orientation |
1822 |
<Image> Diagnosis Active |
1823 |
<Image> Failure Status |
1824 |
<Image> Maintenance Required Status |
1825 |
<Image> Out Of Specification Status |
1826 |
<Image> Function Check Status |
1827 |
Process Variables |
1828 |
Device Setup |
1829 |
Offline |
1830 |
Quick Setup |
1831 |
Reset |
1832 |
Detailed Setup |
1833 |
Service |
1834 |
System |
1835 |
Prepare Parameter Download |
1836 |
Must be performed prior to a complete parameter download to the device.
Writes some basic parameters to the device and performs a warm start. |
1837 |
finish parameter download |
1838 |
Should be performed after a complete parameter download to the device.
Performs a warm start. |
1839 |
Upload Variables |
1840 |
Download Variables |
1841 |
Enable on token-passing data link layer only |
1842 |
Enable on TDMA data link layer only |
1843 |
Enable on both TDMA and token-passing data link layer |
1844 |
Wireless |
1845 |
WirelessHART Device |
1846 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
1847 |
Primary |
1848 |
Primary Analog Channel |
1849 |
Secondary |
1850 |
Secondary Analog Channel |
1851 |
Tertiary |
1852 |
Tertiary Analog Channel |
1853 |
Quaternary |
1854 |
Quaternary Analog Channel |
1855 |
Quinary |
1856 |
Quinary Analog Channel |
1857 |
Critical Power Failure |
1858 |
Lock all |
1859 |
Trim not supported |
1860 |
Configuration cannot be changed |
1861 |
Locked by gateway |
1862 |
Analog Input Channel |
1863 |
Analog Output Channel |
1864 |
PV Analog Channel Saturated |
1865 |
PV Analog Channel Fixed |
1866 |
Device Profile |
1867 |
|
1868 |
Process automation device |
1869 |
Discrete device |
1870 |
Hybrid:Process automation+discrete |
1871 |
I/O System |
1872 |
WirelessHART Process automation device |
1873 |
WirelessHART Discrete device |
1874 |
WirelessHART Process automation+discrete |
1875 |
WirelessHART Gateway |
1876 |
WirelessHART Access point |
1877 |
WirelessHART Process adapter |
1878 |
WirelessHART Discrete adapter |
1879 |
WirelessHART enabled handheld/portable maintenance tool |
1880 |
Device Diagnostic Status 0 |
1881 |
Simulation active |
1882 |
The device is in simulation mode and the level output is not representative of the process. |
1883 |
Non-Volatile memory failure |
1884 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
1885 |
Volatile memory error |
1886 |
The RAM memory check is invalid or maybe corrupt |
1887 |
Watchdog reset executed |
1888 |
A watchdog reset has been performed |
1889 |
Voltage conditions out of range |
1890 |
A voltage condition is outside its allowable range |
1891 |
Environmental conditions out of range |
1892 |
An internal or environmental condition is beyond acceptable limits. |
1893 |
Electronic failure |
1894 |
A hardware problem not related to the sensor has been detected. |
1895 |
Device Diagnostic Status 1 |
1896 |
I/O and Subdevice Status |
1897 |
Subdevice list changed |
1898 |
Duplicate master detected |
1899 |
WirelessHART Status |
1900 |
Capacity Denied |
1901 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
1902 |
Bandwidth allocation pending |
1903 |
Block transfer pending |
1904 |
Secondary Analog Channel Saturated |
1905 |
Tertiary Analog Channel Saturated |
1906 |
Quaternary Analog Channel Saturated |
1907 |
Quinary Analog Channel Saturated |
1908 |
Secondary Analog Channel Fixed |
1909 |
Tertiary Analog Channel Fixed |
1910 |
Quaternary Analog Channel Fixed |
1911 |
Quinary Analog Channel Fixed |
1912 |
Read receive time |
1913 |
Write date and time |
1914 |
Time Set Option |
1915 |
Non-Volatile Clock |
1916 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
1917 |
Clock Uninitialized |
1918 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
1919 |
Real Time Clock Flags |
1920 |
Time Stamp |
1921 |
Relative time value on network |
1922 |
8u |
1923 |
Dynamic Variables Returned for Device Variables |
1924 |
Command Response Truncated |
1925 |
Configuration Change Counter Mismatch |
1926 |
Status bytes mismatch |
1927 |
Device Variable |
1928 |
Analog Channel Number |
1929 |
Analog Channel Number- Index into an array of Analog Channels. |
1930 |
Index 1 into Analog Channel Array |
1931 |
Index into Analog Channel Array- Is the first of an array of addresses, whose value is identified by the Analog Channel Code. |
1932 |
Index 2 into Analog Channel Array |
1933 |
Index into Analog Channel Array- Is the second of an array of addresses, whose value is identified by the Analog Channel Code. |
1934 |
Index 3 into Analog Channel Array |
1935 |
Index into Analog Channel Array- Is the third of an array of addresses, whose value is identified by the Analog Channel Code. |
1936 |
Index 4 into Analog Channel Array |
1937 |
Index into Analog Channel Array- Is the fourth of an array of addresses, whose value is identified by the Analog Channel Code. |
1938 |
Current Date |
1939 |
Current Date based upon the real-time clock in the field device |
1940 |
Current Time |
1941 |
Current Time based upon the real-time clock in the field device |
1942 |
Set Clock Date |
1943 |
Date to set the real-time clock in the field device to, or date that the real-time clock was last set |
1944 |
Set Clock Time |
1945 |
Time to set the real time clock in the field device to, or time that the real-time clock was last set |
1946 |
Select alignment: |
1947 |
Break;Display -> HART;Load Defaults |
1948 |
invalid option |
1949 |
Write new settings to the device? |
1950 |
No;Yes |
1951 |
Are you sure? |
1952 |
Cold start is being executed,
Wait... |
1953 |
Output is now in normal operating mode. |
1954 |
Output is still fixed. Retry the complete test. |
1955 |
Select fixed Level |
1956 |
Output is fixed to
%{1} %{0}. |
1957 |
Enter Date: |
1958 |
Enter Time: |
1959 |
Clock set to: %{0} %{1} |
1960 |
Mappings have been reset. |
1961 |
Enable status simulation? |
1962 |
Disable status simulation? |
1963 |
Failed to enable status simulation. |
1964 |
Status simulation disabled. |
1965 |
Status simulation enabled. |
1966 |
Failed to disable status simulation. |
1967 |
Select function |
1968 |
Warm start is being executed,
Wait... |
1969 |
Dependent units settings will be adjusted automatically.
Proceed anyway? |
1970 |
Select diagnosis |
1971 |
Simulation finished |
1972 |
Simulation still running. |
1973 |
Enter Value in %{0} : |
1974 |
Error setting simulation value |
1975 |
Simulated value: %{1} %{0} |
1976 |
Calibration finished |
1977 |
Select |
1978 |
Break;Manual;Factory Calib.;Automatic |
1979 |
Enter Value in percent: |
1980 |
Factory Calibration OK |
1981 |
Calibration takes %[.0f]{0}s.
Please wait ... |
1982 |
Calibrate Zero %{0}. |
1983 |
Calibrate Zero %{0}%. |
1984 |
Invalid option |
1985 |
Reading current settings.
Please wait ... |
1986 |
Enter Product Density Value in %{0} : |
1987 |
OK;Break |
1988 |
Density Calibration %{0}. |
1989 |
Identnumber:
%{0}
Software Version:
%{2}
Production Date:
%{3} |
1990 |
Value corrected to: %{1} %{0}
(minimum value for HART current output). |
1991 |
Set No. Of pulses: |
1992 |
%{0} pulses sent. |
1993 |
Enter value: |
1994 |
Simulated value: %{0} |
1995 |
Totaliser has been reset. |
1996 |
Enter preset value in %{0} |
1997 |
Totaliser has been set. |
1998 |
Totaliser has been stopped. |
1999 |
Totaliser has been started. |
2000 |
Select measurement |
2001 |
Select Module |
2002 |
Identnumber:
%{0}
Hardware ID:
%{1}
Software Version:
%{2} |
2003 |
Production Date:
%{3}
Calibration Date:
%{4}
Board Serial No.:
%{5} |
2004 |
Errors have been reset. |
2005 |
Enter object number: |
2006 |
Enter sub number: |
2007 |
Select data type |
2008 |
Object %{0}.%{1} is: %{2} |
2009 |
Object %{0}.%{1} set to: %{2} |
2010 |
Enter password: |
2011 |
Service access enabled for 20 min. |
2012 |
Failed to enable service access. |
2013 |
Access level reset to %{0}. |
2014 |
Failed to reset access level. |
2015 |
Please wait ... |