0 |
Device status |
1 |
OK |
2 |
Klay Instruments |
3 |
Klay 2000 Pressure/Level |
4 |
8u |
5 |
mH2O |
6 |
Pressure |
7 |
.1f |
8 |
.2f |
9 |
.f |
10 |
.3f |
11 |
Current span |
12 |
6.1f |
13 |
6.2f |
14 |
4.f |
15 |
6.3f |
16 |
6.f |
17 |
4.1f |
18 |
An.Output |
19 |
% rnge |
20 |
7d |
21 |
Temperature unit |
22 |
Temperature of sensor |
23 |
Proces temperature |
24 |
5.1f |
25 |
Temperature of electronics in housing |
26 |
Housing temperature |
27 |
Local Write protect |
28 |
Cancel mounting position |
29 |
Not Defined |
30 |
Reset |
31 |
Reset mounting position correction |
32 |
Set |
33 |
Set mounting position correction |
34 |
Display Readout |
35 |
Kind of readout on the display of device |
36 |
4-20 mA |
37 |
4-20 mA readout on display |
38 |
Units |
39 |
Digital units readout on display |
40 |
Percent |
41 |
Percent of range readout on display |
42 |
Proces Temperature |
43 |
Proces temperature readout on display |
44 |
Hectoliter |
45 |
Hectoliter readout on display, only when tanklineairisation is active |
46 |
Cubic Meter |
47 |
Cubic meter readout on display, only when tanklineairisation is active |
48 |
Reverse output |
49 |
Set output to 20-4 mA instead of 4-20 mA |
50 |
4-20 mA output |
51 |
20-4 mA |
52 |
20-4 mA output |
53 |
Height of tank |
54 |
Height of the tank, for horizontal tank enter diameter |
55 |
7.3f |
56 |
Lenght of tank |
57 |
Lenght of the tank, for vertikal tank with cone enter diameter |
58 |
Height of cone |
59 |
Height of the cone, if there's no cone enter 0 |
60 |
Height of device |
61 |
Height of the device, this is the height of the bottom of the tank to de device |
62 |
Height of straight part |
63 |
|
64 |
Maximum Span |
65 |
Density factor |
66 |
Density factor |
67 |
Sensortype |
68 |
2000 Range 1 |
69 |
2000 Range 2 |
70 |
2000 Range 3 |
71 |
2000 (SAN) Range 4 |
72 |
CER 2000 Range 4 |
73 |
2000 Special |
74 |
CER 2000 Range 5 |
75 |
Pr Temp |
76 |
Amb Temp |
77 |
Set pressure units |
78 |
Change units of Pressure Value |
79 |
Set temp units |
80 |
Change units of Temperature Value |
81 |
Density Factor |
82 |
The Klay Series 2000 has various readouts for the display. |
83 |
Percentage used of tankheight |
84 |
Percentage of tankheight |
85 |
Normal 4-20 mA |
86 |
No lineairisations |
87 |
Cylindrical tank |
88 |
Lineairization for horizontal tank, hectoliter readout is possibleLinearisation für zylindrischer Tank, Hectoliter Anzeige ist möglich |
89 |
V. tank (cone) |
90 |
Lineairization for vertical tank (with cone), hectoliter readout is possible |
91 |
V. tank (sphere) |
92 |
Lineairization for vertical tank (with spherical cone), hectoliter readout is possible |
93 |
Load Mode |
94 |
Write variables |
95 |
Monitoring |
96 |
Configuration |
97 |
Information |
98 |
Revision Numbers |
99 |
Range Values |
100 |
With Reference |
101 |
Without Reference |
102 |
Xmtr config |
103 |
Set units |
104 |
Read variables |
105 |
Change write prot |
106 |
Set damping value |
107 |
Set damping value.
0 <= Damping <= 25 |
108 |
Lineairisations |
109 |
There are 4 kinds of lineairisations, no lineairisation, cilindrical tank and vertical tank with (spherical) cone. |
110 |
Set reverse output |
111 |
Reverse output (20-4 mA). Not possible when polling address is not equal zero |
112 |
Zero |
113 |
Applied values- Perform a device rerange by applying the desired Span(URV-LRV) and Zero(LRV) to the device input. |
114 |
Span |
115 |
Adjust Zero (4 mA) without testpressure |
116 |
Adjust Span(URV-LRV) without testpressure |
117 |
Mounting position |
118 |
All Klay transmitters are calibrated vertically. When a transmitter of the Series 2000 is installed horizontally, there will be a small mounting effect on the zero (4 mA). For example the transmitter shows 4.03 mA instead of 4.00 mA. This can be easily canceled with this correction |
119 |
Enter new units: |
120 |
Not possible, old software revision!! |
121 |
Enter new density factor: |
122 |
Not supported by this software-revision |
123 |
Choose display readout |
124 |
This readout is not possible, there's no lineairisation. Choose an other readout |
125 |
Cubic meter readout is not possible in this revsision. Choose an other readout |
126 |
Select write prot for device %{0}: |
127 |
Write prot;Local write prot;Send;Leave without send |
128 |
Write protection for communication? |
129 |
Write protection for local indicator? |
130 |
Damping value:
%{0} sec
0 <= Damping <= 25 |
131 |
Enter new damping val: |
132 |
Choose Linearisation: |
133 |
None;Cilindrical tank;Vert tank (cone);Vert tank (spher); |
134 |
None;Cilindrical tank;Vert tank (cone); |
135 |
Enter new height: |
136 |
Enter new length: |
137 |
Enter perc of height: |
138 |
Enter new height(H1): |
139 |
Enter new height(H2): |
140 |
Enter new device height(H3): |
141 |
Enter new straight height(H4): |
142 |
Enter new height: |
143 |
Enter new diameter: |
144 |
Enter new cone height: |
145 |
Enter new device height: |
146 |
Enter new cone height: |
147 |
Reverse output is not possible, device in multi drop mode |
148 |
Choose Output mode: |
149 |
Min. Zero:
%{3} %{0}
Min. Span:
%{1} %{0}
Max. Span:
%{2} %{0} |
150 |
Current Span:
%{4} %{0}
Span will
remain the same! |
151 |
Enter new Zero Value: |
152 |
Min. Span:
%{1} %{0}
Max. Span:
%{2} %{0}
Current Span:
%{4} %{0} |
153 |
Enter new Span Value (Units: %{0}): |
154 |
URV
%{5} %{0}
|
155 |
BE SURE NO PRESSURE IS APPLIED!!!! |
156 |
Sure to continue? |
157 |
Yes;Reset;Leave now.. |
158 |
Resetting mounting position correction |
159 |
Performing mounting position correction |