0 |
EP1000/SPS2000 |
1 |
KOSO |
2 |
Linear |
3 |
Valve transfer function type is Linear(non convert). |
4 |
EqOpen |
5 |
Valve transfer function type is Equal percentage |
6 |
QuOpen |
7 |
Valve transfer function type is Quick opening |
8 |
Custom |
9 |
Valve transfer function type is Free adjustable |
10 |
Transmitter-Specific Status flags |
11 |
Status |
12 |
Device Failure |
13 |
....................... |
14 |
Mechanical Failure |
15 |
alarm occured. |
16 |
ADC failure |
17 |
Error in ADC unit |
18 |
EEPROM failure |
19 |
Error in non-volatile memory unit |
20 |
Pos sensor failure |
21 |
Error in Position sensor unit |
22 |
total_stroke alarm |
23 |
Total stroke alarm limt reached |
24 |
dirction change alarm |
25 |
Total change direction alarm limit |
26 |
temperature alarm |
27 |
Temperature reached thresold limits |
28 |
pressure alarm |
29 |
Pressure reached thresold limits |
30 |
position alarm |
31 |
Position reached threshold limits |
32 |
cutoff activated |
33 |
The output 1 is in alarm |
34 |
travel limt activated |
35 |
The output 2 is in alarm |
36 |
setpoint activated |
37 |
The device needs maintenace |
38 |
IP signal activated |
39 |
The device needs maintenance |
40 |
Out of service |
41 |
Device is set to out of service |
42 |
loop current |
43 |
Loop-current is Set point source |
44 |
hart-command |
45 |
Set point source is via HART-cmd |
46 |
Position |
47 |
Setpoint |
48 |
IP Current |
49 |
Pot Ang pos |
50 |
Pressure |
51 |
Temperature |
52 |
SensorSerialNo |
53 |
Sensor Serial NO: Serial NO of positioner's feedback sensor. |
54 |
.2f |
55 |
Pres units |
56 |
Hejelp |
57 |
Pres USL |
58 |
Pres LSL |
59 |
Pres min span |
60 |
|
61 |
Press |
62 |
Device Variable code |
63 |
pv PDQ |
64 |
SV PDQ |
65 |
|
66 |
TV PDQ |
67 |
FV PDQ |
68 |
Var Class |
69 |
The classification of the dynamic variable |
70 |
PV fmly |
71 |
SV fmly |
72 |
TV fmly |
73 |
FV fmly |
74 |
PV LS |
75 |
SV LS |
76 |
TV LS |
77 |
FV LS |
78 |
PV Fmly stat |
79 |
SV Fmly stat |
80 |
TV Fmly stat |
81 |
FV Fmly stat |
82 |
AN CH |
83 |
Number of analigue channels |
84 |
One Analog Ch |
85 |
One Out Channel. |
86 |
TempUnit |
87 |
Temperature USL |
88 |
Temperature LSL |
89 |
Temperature min span |
90 |
Temp |
91 |
Collection of Temperature (secondary) Variable Data Items |
92 |
Valve Position |
93 |
PositionUnit |
94 |
Position Class |
95 |
Position USL |
96 |
Position LSL |
97 |
Position min span |
98 |
Collection of position Variable Data Items |
99 |
min_span |
100 |
damping_value |
101 |
sensor_ser_nO |
102 |
CurrentUnit |
103 |
IP converter Class |
104 |
Current |
105 |
IPcurrent USL |
106 |
IPcurrent LSL |
107 |
IPcurrent min span |
108 |
IP Cur |
109 |
Collection of IP-Current Variable Data Items |
110 |
Angle |
111 |
AngleUnit |
112 |
Angle Class |
113 |
Angle USL |
114 |
Angle LSL |
115 |
Angle min span |
116 |
Collection of Angle Variable Data Items |
117 |
Ang_class |
118 |
Limit |
119 |
Ang_usl |
120 |
Ang_lsl |
121 |
Ang_min_span |
122 |
SetpointUnit |
123 |
Setpoint Class |
124 |
Set-Point |
125 |
Setpoint USL |
126 |
.1f |
127 |
Setpoint LSL |
128 |
setpoint_min_span |
129 |
Set Point |
130 |
Setpos |
131 |
Set point value between 0 and 100 % |
132 |
Autotune state |
133 |
Auto tune state indicating flag |
134 |
oper_mode |
135 |
Set point source... |
136 |
Out_of_service |
137 |
Out of Service |
138 |
Lp_current |
139 |
4-20 mA |
140 |
HART-Master |
141 |
HART r |
142 |
IPSource |
143 |
Normal |
144 |
Normal Source |
145 |
Hart source |
146 |
Set By Hart |
147 |
IP Converter |
148 |
IP Converter value between 0 and 100 % |
149 |
Pot crosspoint |
150 |
Seting of Potentiometer crosspoint value |
151 |
Act pot relation |
152 |
Actuator Potentiometer Relation Value |
153 |
CW |
154 |
Clock-wise |
155 |
CCW |
156 |
Counter-Clock-wise |
157 |
Actuator type |
158 |
Actuator type: Double/Single acting Rotary/Linear |
159 |
DARot |
160 |
Double acting Rotary actuator |
161 |
SARot |
162 |
Singel acting Rotary actuator |
163 |
DALin |
164 |
Double acting Linear actuator |
165 |
SALin |
166 |
Singel acting Linear actuator |
167 |
Actuator dir |
168 |
Direct/Reverse acting: Set the controller for a direct or reverse acting actuator. |
169 |
Direct |
170 |
Direct acting: Increase in signal rotates anti-clockwise,decrease clockwise. |
171 |
Reverse |
172 |
Reverse acting: Increase in signal rotates clockwise,decrease anti-clockwise. |
173 |
ValveDir |
174 |
Step Direction. |
175 |
Down |
176 |
Step downward |
177 |
Up |
178 |
Step Upwards: |
179 |
step_granularity |
180 |
Step Granularity |
181 |
Super_Fine |
182 |
Up to 5 % steps |
183 |
Fine |
184 |
Up to 10 % steps |
185 |
Medium |
186 |
Up to 20 % steps |
187 |
Large |
188 |
Up to 25 % steps |
189 |
Very_Large |
190 |
Up to 30 % steps |
191 |
Time to open |
192 |
The time measure during autotune required to open the valve |
193 |
Time to close |
194 |
The time required to close the valve. Measured during autotune. |
195 |
Start position |
196 |
Target position |
197 |
Target time |
198 |
Split range |
199 |
The split range facility allows two positioners to work together controlled by a single 4-20mA source.When you select Enbl,you can use this function. |
200 |
Dsbl |
201 |
Disable: You cannot use split range function. |
202 |
Enbl |
203 |
Enable: You can use split range function. |
204 |
SplitrangeUnits |
205 |
Split Range Lower Units |
206 |
Splitrangelwr |
207 |
Low position: You can input low position of split range from -20.0% to 80.0%.But you must set the value (High-Low>40.0%). |
208 |
Splitrangeupr |
209 |
High position: You can input high position of split range from 20.0% to 120.0%.But you must set the value (High-Low>40.0%). |
210 |
Coil Current range |
211 |
% |
212 |
Write protection |
213 |
Enable/Disable Write Protection |
214 |
OFF |
215 |
Disable: Write not protected |
216 |
ON |
217 |
Enable: Write Protected |
218 |
Valve pot relation |
219 |
Relation between the Potentiometer & Valve |
220 |
DeadBand |
221 |
Dead band adjustment region = 0.1% to 10.0% |
222 |
Proportional |
223 |
Proportional gain of PID. |
224 |
Integral |
225 |
Integral gain of PID. |
226 |
Derivative |
227 |
Derivative gain of PID |
228 |
Upr cutoff |
229 |
Cut Off Parameters |
230 |
Lwr cutoff |
231 |
Upr limit |
232 |
Limit Parameters |
233 |
Lwr limit |
234 |
Index |
235 |
X_value |
236 |
Custom Curve X-Value |
237 |
Y_value |
238 |
Custom Curve Y-Value |
239 |
LoSetPoint |
240 |
Lower Set point calibration point. |
241 |
UpSetPoint |
242 |
Upper Set-point Calibration Point. |
243 |
LoPrespoint |
244 |
Lower Pressure Calibration Point |
245 |
UpPrespoint |
246 |
Upper Pressure Point |
247 |
TCalPoint |
248 |
Temperature Calibration Point |
249 |
StrokeAlarmFlag |
250 |
Enable/Disable Stroke Alarm |
251 |
Disable: Alarm OFF |
252 |
Enable: Alarm ON |
253 |
Stroke Alarm |
254 |
Total Stroke Alarm Value. |
255 |
Stroke DeadBand |
256 |
Deadband for stroke alarmvalue given in % of stroke. |
257 |
T dir ch AlarmFlag |
258 |
Enable/Disable Total change dir alarm flag |
259 |
TDirCh Alarm |
260 |
Total Change dir Alarm Value. |
261 |
TDirCh deadband |
262 |
Deadband for total direction change alarmvalue given in % of total stroke. |
263 |
TempAlarm |
264 |
Enable/Disable Temperature level limits. |
265 |
TempUnits |
266 |
Supported Temperature units for alarm are dec C and deg F. |
267 |
TAlarmLimit |
268 |
Alarm Limit for Temperature. |
269 |
Pres Alarm |
270 |
Enable/Disable Pressure level limits. |
271 |
PresUnits |
272 |
Supported pressure units are psi, bar and kPA. |
273 |
PAlarmLimit |
274 |
Alarm Limit for Pressure. |
275 |
TotNoStroke |
276 |
Total number of strokes. |
277 |
TotDirChg |
278 |
Total number of change of direction. |
279 |
Max temperature |
280 |
Maximum Temperature value. |
281 |
Min temperature |
282 |
Minimum Temperature value. |
283 |
Pressure |
284 |
Pressure. |
285 |
DevAlarmflg |
286 |
Enable/Disable Deviation level limits. |
287 |
Devthreshold |
288 |
Deviation Threshold given in Percent %. |
289 |
DevWtime |
290 |
Deviation Wait Time 0 - 5 seconds. |
291 |
sec |
292 |
PosAlarmflg |
293 |
Enable/Disable Position level limits. |
294 |
PosLthreshold |
295 |
Positionn Low Threshold given in Percent %. |
296 |
PosHthreshold |
297 |
Positionn high Threshold given in Percent %. |
298 |
PosWtime |
299 |
Position Threshold Wait Time Time 0 - 5 seconds. |
300 |
MfrDate MM/DD/YY |
301 |
Device date Of Manufacture: The date that positioner was manufactured is indicated.(MM/DD/YY) |
302 |
DeviceName |
303 |
Device Name: Device name is indicated. |
304 |
AccOprTime |
305 |
Total operating time(hour): The time since last maintenance date is set. |
306 |
h |
307 |
total_operate |
308 |
Total number of operations: The number of operations since last maintenance date is set. |
309 |
cycles |
310 |
DeviceSerialNo |
311 |
Device serial number: Serial No of the positioner. |
312 |
Calibration of setpoint |
313 |
counts |
314 |
Device setup |
315 |
Process variables |
316 |
Diagnostics and service |
317 |
Basic setup |
318 |
Dynamic var |
319 |
Detailed setup |
320 |
Device info |
321 |
Rev numbers |
322 |
Diagnosis data |
323 |
Device service |
324 |
Set alarms |
325 |
Calibration |
326 |
Open/Close times |
327 |
Actuator setting |
328 |
Cutoff |
329 |
Limits |
330 |
PID parameters |
331 |
Custom curve |
332 |
Device operating mode |
333 |
Manual control |
334 |
Total stroke |
335 |
Total dir change |
336 |
Temperature alarm |
337 |
Pressure alarm |
338 |
Position alarm |
339 |
Deviation alarm |
340 |
Reset menu |
341 |
Ramp data |
342 |
Autotune |
343 |
Start the Autotuning of the device. |
344 |
CalSetpoint |
345 |
Analog to digital convert calibration |
346 |
Pressure calib |
347 |
Pressure channel - two point Calibration. You will need an external pressure source. |
348 |
temp_chan |
349 |
Temperature One point Calibration. Enter Calibartion value. |
350 |
Resetconfigflag |
351 |
Reset configuration change flag |
352 |
EEPROM |
353 |
Master reset |
354 |
Perform_Master_Reset |
355 |
Reset diag |
356 |
Reset diagnosis parameters |
357 |
Set Total stroke |
358 |
Set/Reset total stroke |
359 |
Set Total dirchange |
360 |
Set/Reset total dir change |
361 |
Used to read/write user defined transfer function. The curve can have 20 data points. |
362 |
Step valve |
363 |
Position cotrol using 5 different step resolutions |
364 |
Rerange |
365 |
FMU860 |
366 |
DT |
367 |
DVC |
368 |
FCX |
369 |
AS800 |
370 |
340T |
371 |
340C |
372 |
344 |
373 |
Siemens Micro K |
374 |
SITRANS L |
375 |
SIPAN PH |
376 |
SITRANS P |
377 |
75SMT |
378 |
UNIDELTA |
379 |
8320 |
380 |
SX5100 |
381 |
TSV175 |
382 |
DMU |
383 |
3780 |
384 |
BM70 |
385 |
8u |
386 |
8.3f |
387 |
.3f |
388 |
You are to start autotuning. |
389 |
Aborting method due to last error |
390 |
Autotune process in Progress |
391 |
Tuning completed successfully. |
392 |
Device not tuned. |
393 |
Tuning on failed. |
394 |
You are starting to calibrate lower setpoint. Set loop current to 4 mA. |
395 |
Are you certain that loop current is 4.0 mA? |
396 |
Lower Setpoint Calibration completed. |
397 |
You are starting to calibrate upper setpoint. Set loop current to 20 mA. |
398 |
Are you certain that Loop-current is 20.0 mA? |
399 |
Upper Setpoint Calibration completed. |
400 |
You are to Calibrate lower pressure point. Set pressure to lower calibration point. |
401 |
Enter lower calib-point |
402 |
You are to Calibrate upper pressure point. Set pressure to upper calibration point. |
403 |
Enter upper calibration point |
404 |
Pressure sensor calibrated. |
405 |
You are to Calibrate Temperature sensor. |
406 |
Enter temperature calibration value |
407 |
Temperature sensor calibrated. |
408 |
Do you want to reset the configuration change flag? |
409 |
The Configuration change flag is reset. |
410 |
Do you want to run EEPROM control command? |
411 |
Do you want to Save or Restore? |
412 |
SAVE;RESTORE |
413 |
Latest modifications saved to EEPROM. |
414 |
You are to restore data from EEPROM. |
415 |
Parameters are restored from EEPROM. |
416 |
You are to Reset the device. |
417 |
Master Reset operation completed. |
418 |
You are to reset diagnosis data. |
419 |
Reset diagnosis is completed. |
420 |
You are to change Total stroke value. |
421 |
Enter total stroke |
422 |
Setting Total stroke is completed. |
423 |
You are to change Total dirchange value. |
424 |
Enter Total dirchange |
425 |
Setting of Total dirchange is completed. |
426 |
You are about to read/write the Valve Characteristic table data. |
427 |
Do you want to Read or Write? |
428 |
Read;Write |
429 |
Table Index is: %{0} |
430 |
Reading in progress |
431 |
Table Index number: %{0}
X_axis_point: %{1}
Y_axis_point: %{2} |
432 |
Reading completed |
433 |
You are to Write Valve Characteristic table data. |
434 |
Enter X-axis point: |
435 |
Enter Y-axis point: |
436 |
Aborting method due to last error |
437 |
Writing in progress |
438 |
Entered Index: %{0}
Entered X_data: %{1}
Entered Y_data: %{2} |
439 |
Writing completed |
440 |
You are to start Valve step & direction control. |
441 |
Do you want to run Valve control? |
442 |
YES;NO |
443 |
Select step direction. |
444 |
Down;Up |
445 |
Select step granularity. |
446 |
very_fine; fine; medium; large; very_large |
447 |
Direction of motion: %{0}
Step Granularity : %{1} |
448 |
Step command in progess |
449 |
Position value is: %{0}
Setpoint value is: %{1} |
450 |
Do you want to Continue? |
451 |
Do you want start again? |
452 |
Step control operation completed |
453 |
You are to set the device operation ranges. |
454 |
Select the calibration point |
455 |
Lower_range;Upper_range |
456 |
Lower range process value: %{0}
Process value unit : %{1} |
457 |
Is the applied process value to be the desired lower range? |
458 |
Lower range setting completed. |
459 |
Upper range process value: %{0}
Process value unit : %{1} |
460 |
Is the applied process value to be the desired upper range? |
461 |
Upper range setting completed. |