0 |
SLN700 |
1 |
Honeywell |
2 |
Critical |
3 |
EEProm Error |
4 |
Return to Factory |
5 |
PLL Error |
6 |
PLL Failed, RF circuit failure.
return unit to Factory |
7 |
Op Error |
8 |
Internal Operation Error.
return unit to Factory |
9 |
CmdCode Error |
10 |
Internal Command Error.
return unit to Factory |
11 |
Auth Failed |
12 |
System Busy |
13 |
Restart, if problems persist
return unit to Factory |
14 |
Low Power Error |
15 |
Low power supply. Check power supply |
16 |
Dsp Comm Error |
17 |
Communication error between
display and module.
Replace with new display module |
18 |
Cmd Parse Error |
19 |
Internal command parse error |
20 |
AD Error |
21 |
AD sampling error,
Return to Factory |
22 |
Calibration Flash Error |
23 |
RF Calibration Flash Error,
Return to Factory |
24 |
DspAuthError |
25 |
DSP Authentication Error.
Return to Factory. |
26 |
No Signal Error |
27 |
No signal back,will see no
reflective echo on echo curve.
Check antenna aiming.
Check if the application is
having excessive vapor/steam |
28 |
Lock/Unlock Device |
29 |
Distance Value |
30 |
.3f |
31 |
Distance Unit |
32 |
ft |
33 |
m |
34 |
in |
35 |
cm |
36 |
mm |
37 |
Distance Dev fmly |
38 |
Distance Class |
39 |
Minimum Span |
40 |
8.3f |
41 |
Distance Update Period |
42 |
|
43 |
7d |
44 |
Simulate |
45 |
Distance To Product |
46 |
Update Period |
47 |
Temperature Value |
48 |
Temperature Unit |
49 |
Temperature Class |
50 |
Temperature Update Period |
51 |
Temperature |
52 |
Distance |
53 |
CmdType |
54 |
GetData |
55 |
SetData |
56 |
simulationUnit |
57 |
Fast Level Change |
58 |
Empty Value |
59 |
Fixed Range |
60 |
Fixed Blind |
61 |
Low Adjuest Value |
62 |
High Adjuest Value |
63 |
Temperature |
64 |
InputVoltage |
65 |
Signal Strength |
66 |
Sensor Tag |
67 |
Measuring Medium Type |
68 |
Measuring Unit |
69 |
User Blind |
70 |
User Range |
71 |
Current Out Mode |
72 |
EFF Curve |
73 |
Echo Curve |
74 |
False Echo Curve |
75 |
Simualte |
76 |
False Echo Distance |
77 |
False Echo Status |
78 |
Failure Mode |
79 |
Reset Factory |
80 |
Distance Adjuest |
81 |
Echo Threshold |
82 |
Damping Factor |
83 |
Envelope Level |
84 |
Hart Poll Addr |
85 |
MultiDrop Option |
86 |
Damping Time |
87 |
Max Level Speed |
88 |
First Echo Option |
89 |
MultiWave |
90 |
IF Gain |
91 |
Tx Power |
92 |
Rx Gain |
93 |
4ma Adjust |
94 |
20mA Adjust |
95 |
Low Dk Option |
96 |
Empty Span |
97 |
Dust Or Agitation |
98 |
Device Type |
99 |
Device ID |
100 |
Data Of Manufacture |
101 |
MB Version |
102 |
DSP Version |
103 |
RF Version |
104 |
LCD Version |
105 |
DistanceTo Product |
106 |
Product Level |
107 |
method7 |
108 |
Product Level % |
109 |
% |
110 |
Fixed Range |
111 |
Fixed blind |
112 |
Distance URV |
113 |
Distance LRV |
114 |
degC |
115 |
Input Voltage |
116 |
V |
117 |
Signal Strength |
118 |
dB |
119 |
Sensor tag |
120 |
Medium |
121 |
is used to select liquid, solid to further determine some other properties of the material that affect the measurement |
122 |
Liquid |
123 |
Solid |
124 |
Distance Units |
125 |
Messaure unit |
126 |
Units of Measurement |
127 |
method2 |
128 |
Near Blanking |
129 |
When fixed obstacles interferes with the measurement near the sensor surface and the maximum material height does not reach the obstacle, the near blanking setting function can be used to avoid measurement errors.Entered value > Fixed blind and < User range |
130 |
User range |
131 |
Measuring Range (Entered value > Near Blanking and < Fixed range) |
132 |
Sel. Current Output |
133 |
4-20mA |
134 |
4-20mA Current out Mode |
135 |
20-4mA |
136 |
20-4mA Current out Mode |
137 |
Simulation Status |
138 |
Shows the status of Simulation mode ON/OFF |
139 |
OFF |
140 |
open simulate |
141 |
ON |
142 |
close simulate |
143 |
Simualte Value |
144 |
Simualte Loop Current Value |
145 |
Simulate Value |
146 |
Simulate Distance Value |
147 |
.6f |
148 |
Simulate type |
149 |
Current Simulate |
150 |
Empty High Simulate |
151 |
False echo distance |
152 |
False echo status |
153 |
Shows False echo status |
154 |
Busy |
155 |
Idle |
156 |
Burnout Direction |
157 |
Set burnout Current |
158 |
NO Change |
159 |
21.5mA |
160 |
3.6mA |
161 |
Distance Offset |
162 |
Set offset of distance output value |
163 |
Echo Threshold |
164 |
Threshold setting is used to set the threshold size of the effective echo |
165 |
Damping Factor |
166 |
Change percent from One value jump to other value. |
167 |
Envelope Level |
168 |
Set the level of Envelope |
169 |
Poll Address |
170 |
MultiDrop Option |
171 |
Set the fixed current in multidrop mode |
172 |
Normal |
173 |
4mA |
174 |
8mA |
175 |
Damping Time |
176 |
Take average of measurement value as output in this time |
177 |
Max_Level_Speed_Unit |
178 |
ft/s |
179 |
m/s |
180 |
in/s |
181 |
cm/s |
182 |
mm/s |
183 |
Max Level Rate |
184 |
Set max level rate |
185 |
First Echo Option |
186 |
Change the weight of first echo |
187 |
Small |
188 |
Big |
189 |
Bigger |
190 |
Biggest |
191 |
MultiWave |
192 |
Enable multiwave algorithm to get the correct echo |
193 |
No |
194 |
Yes |
195 |
IF Gain |
196 |
Tx Power |
197 |
Weak |
198 |
Rx Gain |
199 |
4ma Adjust |
200 |
20ma Adjust |
201 |
Low Dk Option |
202 |
For Low DK use.To enable low DK bottom algorithm |
203 |
Empty Span |
204 |
If low DK option is yes, Input the bottom distance.Entered value > zero and < Fixed Range |
205 |
Dust Or Agitation |
206 |
Set degree of dust or agitation |
207 |
Mild |
208 |
Strong |
209 |
Model Type |
210 |
Serial Number |
211 |
Date Of Manufacture |
212 |
YYYYMMDD |
213 |
MB Version |
214 |
DSP Version |
215 |
RF Version |
216 |
LCD Version |
217 |
Reset command |
218 |
basic reset |
219 |
factory reset |
220 |
Max. Distance |
221 |
Max. distance after boot up |
222 |
Min. Distance |
223 |
Min. distance after boot up |
224 |
Max. Voltage |
225 |
Max. voltage after boot up |
226 |
Min. Voltage |
227 |
Min. voltage after boot up |
228 |
Hour |
229 |
2.0f |
230 |
8.0f |
231 |
Minute |
232 |
Second |
233 |
.0f |
234 |
h |
235 |
min |
236 |
Echo Lost Timeout |
237 |
Timeout for echo error not found |
238 |
s |
239 |
Calibrate Date |
240 |
Calibrate Date in YYYYMMDD |
241 |
Latching Mode |
242 |
Any error will be latched if enable this mode. |
243 |
Non-Latching |
244 |
Latching |
245 |
Device state |
246 |
StateOk |
247 |
CommErr |
248 |
EEPRom |
249 |
OpErr |
250 |
CmdParseError |
251 |
Auth Err |
252 |
SysBusy |
253 |
LowPower Err |
254 |
DspCommErr |
255 |
AD Err |
256 |
CalibFlashErr |
257 |
CalibFlashErr |
258 |
DspAuth |
259 |
NoSignal Err |
260 |
Write Protect |
261 |
Set to Write Protect Password |
262 |
Measure unit false echo |
263 |
Internal DD Revision |
264 |
DD Rev |
265 |
1.1.0A |
266 |
Locked |
267 |
min. volt time |
268 |
This method shows the min. volt time in HH::MM:SS |
269 |
Service Time |
270 |
This method shows Service Time in HH:MM:SS |
271 |
Show User Range Limits |
272 |
This method shows the user range limits |
273 |
Show Near blanking Limits |
274 |
This method shows the Near blanking limits |
275 |
Show URV Limits |
276 |
This method shows distance URV limits |
277 |
Show LRV Limits |
278 |
This method shows distance LRV limits |
279 |
Show distance Limits |
280 |
This method shows the simulate distance limits |
281 |
Show Max. Level Rate Limits |
282 |
This method shows Max. Level Rate Limits |
283 |
Loop Current Simulation |
284 |
This method used to simulate Loop Current |
285 |
Distance Simulation |
286 |
This method used to simulate Distance |
287 |
Max/Min Distance Reset |
288 |
This method reset min/max distance value |
289 |
Max/Min Voltage Reset |
290 |
This method reset min/max Voltage value |
291 |
Set False Echo Distance |
292 |
This method will set false echo distance |
293 |
Master Reset |
294 |
Soft power reset to the device |
295 |
Factory Reset |
296 |
len1 |
297 |
Write Protect On/Off |
298 |
enter password to enable or disable Write Protect |
299 |
Echo curve data |
300 |
False echo curve data |
301 |
EFF echo |
302 |
curve data array |
303 |
Echo Curve(Curve) |
304 |
False Echo Curve |
305 |
EFF_Curve |
306 |
Echo Curve |
307 |
method6 |
308 |
EFF Echo |
309 |
Offline[Table View] |
310 |
Diagnostics |
311 |
Maintenance |
312 |
Process Monitoring |
313 |
Offline Configuration |
314 |
My Device |
315 |
Device Setup |
316 |
Basic Configuration |
317 |
General |
318 |
Process |
319 |
Loop Outputs |
320 |
Summary |
321 |
Advanced Configuration |
322 |
Echo Settings |
323 |
Services |
324 |
Monitor |
325 |
Dashboard |
326 |
Device Status |
327 |
Device Information |
328 |
EFF Echo Curve |
329 |
Full Echo Curve |
330 |
Adv Diagnostics |
331 |
Download to Device |
332 |
Upload from Device |
333 |
Upload Variables |
334 |
Device health |
335 |
Overall health of the transmitter |
336 |
Honeywell_Logo |
337 |
PV Analog Channel Saturated |
338 |
PV Analog Channel Fixed |
339 |
Wireless |
340 |
WirelessHART Device |
341 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
342 |
Primary |
343 |
Primary Analog Channel |
344 |
Secondary |
345 |
Secondary Analog Channel |
346 |
Tertiary |
347 |
Tertiary Analog Channel |
348 |
Quaternary |
349 |
Quaternary Analog Channel |
350 |
Quinary |
351 |
Quinary Analog Channel |
352 |
Critical Power Failure |
353 |
Lock all |
354 |
Trim not supported |
355 |
Configuration cannot be changed |
356 |
Locked by gateway |
357 |
Analog Input Channel |
358 |
Analog Output Channel |
359 |
Secondary Analog Channel Saturated |
360 |
Tertiary Analog Channel Saturated |
361 |
Quaternary Analog Channel Saturated |
362 |
Quinary Analog Channel Saturated |
363 |
Secondary Analog Channel Fixed |
364 |
Tertiary Analog Channel Fixed |
365 |
Quaternary Analog Channel Fixed |
366 |
Quinary Analog Channel Fixed |
367 |
Simulation active |
368 |
The device is in simulation mode and the level output is not representative of the process. |
369 |
Non-Volatile memory failure |
370 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
371 |
Volatile memory error |
372 |
The RAM memory check is invalid or maybe corrupt |
373 |
Watchdog reset executed |
374 |
A watchdog reset has been performed |
375 |
Voltage conditions out of range |
376 |
A voltage condition is outside its allowable range |
377 |
Environmental conditions out of range |
378 |
An internal or environmental condition is beyond acceptable limits. |
379 |
Electronic failure |
380 |
A hardware problem not related to the sensor has been detected. |
381 |
Subdevice list changed |
382 |
Duplicate master detected |
383 |
Capacity Denied |
384 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
385 |
Bandwidth allocation pending |
386 |
Block transfer pending |
387 |
Battery life |
388 |
Percent range |
389 |
Loop current |
390 |
Primary variable |
391 |
Secondary variable |
392 |
Tertiary variable |
393 |
Quaternary variable |
394 |
Read receive time |
395 |
Write date and time |
396 |
Non-Volatile Clock |
397 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
398 |
Clock Uninitialized |
399 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
400 |
None |
401 |
No restrictions |
402 |
SI Only |
403 |
Restricted to SI Unit codes only |
404 |
Process automation device |
405 |
Discrete device |
406 |
Hybrid:Process automation+discrete |
407 |
I/O System |
408 |
WirelessHART Process automation device |
409 |
WirelessHART Discrete device |
410 |
WirelessHART Process automation+discrete |
411 |
WirelessHART Gateway |
412 |
WirelessHART Access point |
413 |
WirelessHART Process adapter |
414 |
WirelessHART Discrete adapter |
415 |
WirelessHART enabled handheld/portable maintenance tool |
416 |
Device Profile |
417 |
US |
418 |
United States of America |
419 |
JP |
420 |
Japan |
421 |
DE |
422 |
Germany |
423 |
FR |
424 |
France |
425 |
ES |
426 |
Spain |
427 |
RU |
428 |
Russian Federation |
429 |
CN |
430 |
People's Republic of China |
431 |
Secondary Master |
432 |
Primary Master |
433 |
Device Diagnostic Status 0 |
434 |
Device Diagnostic Status 1 |
435 |
I/O and Subdevice Status |
436 |
WirelessHART Status |
437 |
Time Set Option |
438 |
Real Time Clock Flags |
439 |
Country |
440 |
Country of intended device installation |
441 |
SI Unit Control |
442 |
Indicates if device should only display SI unit codes |
443 |
Time Stamp |
444 |
Relative time value on network |
445 |
8u |
446 |
Dynamic Variables Returned for Device Variables |
447 |
Command Response Truncated |
448 |
Configuration Change Counter Mismatch |
449 |
Status bytes mismatch |
450 |
min volt time |
451 |
min. volt time (HH:MM:SS): %{Voltage_Hour}:%{Voltage_Minu}:%{Voltage_Sec} |
452 |
Service Time (HH:MM:SS): %{Work_Hour}:%{Work_Minu}:%{Work_Sec} |
453 |
User Range in '%{Measure_unit_local}' : Min. Value : %{User_range.MIN_VALUE} , Max. Value : %{User_range.MAX_VALUE} |
454 |
Near blankig in '%{Measure_unit_local}' : Min. Value : %{User_binld.MIN_VALUE} , Max. Value : %{User_binld.MAX_VALUE} |
455 |
URV Limits in '%{Measure_unit_local}' : Min. Value : %{Low_Adjuest.MIN_VALUE} , Max. Value : %{Low_Adjuest.MAX_VALUE} |
456 |
LRV Limits in '%{Measure_unit_local}' : Min. Value : %{High_Adjuest.MIN_VALUE} , Max. Value : %{High_Adjuest.MAX_VALUE} |
457 |
Simulate distance Limits in '%{Measure_unit_local}' : Min. Value : %{Simulate_Value_Distance.MIN_VALUE} , Max. Value : %{Simulate_Value_Distance.MAX_VALUE} |
458 |
Max Level Rate Limits in '%{Measure_unit_local}' : Min. Value : %{Max_Level_Speed.MIN_VALUE} , Max. Value : %{Max_Level_Speed.MAX_VALUE} |
459 |
Current Simulation |
460 |
Start Simulation;Stop Simulation;Exit |
461 |
Input Value: |
462 |
Start Simulation |
463 |
Stop Simulation |
464 |
Input Value : %{Measure_unit_local} |
465 |
Would you like to do Reset? |
466 |
Succeeded Reset. |
467 |
Failed to Reset. |
468 |
False Echo |
469 |
Please wait,finding false echo operation states |
470 |
Master Reset done |
471 |
Would you like to do Factory Reset? |
472 |
Parameters restoring to factory default values |
473 |
Succeeded Factory Reset. |
474 |
Failed to Factory Reset. |
475 |
Password(6-digtal) |
476 |
Password is incorrect! |
477 |
Please ensure that the device is not in hardware/software write protect mode.
WARN-Loop should be removed from automatic control |