0 |
FL3100H/FL3101H/FlameGard 5 UV/IR |
1 |
General Monitors |
2 |
.3f |
3 |
Pres Class |
4 |
Pres PDQ |
5 |
Pres LS |
6 |
Pres Fmly stat |
7 |
8.3f |
8 |
7d |
9 |
Pressure |
10 |
Device Setup Menu |
11 |
Basic Setup |
12 |
Detailed Setup |
13 |
Configuration Menu |
14 |
System Firmware |
15 |
System Firmware Revision |
16 |
Rev A |
17 |
Rev B |
18 |
Rev C |
19 |
Rev D |
20 |
Rev E |
21 |
Rev F |
22 |
Rev G |
23 |
Rev H |
24 |
Rev I |
25 |
Rev J |
26 |
Rev K |
27 |
Rev L |
28 |
Rev M |
29 |
Rev N |
30 |
Rev O |
31 |
Rev P |
32 |
Rev Q |
33 |
Rev R |
34 |
Rev S |
35 |
Rev T |
36 |
Rev U |
37 |
Rev V |
38 |
Rev W |
39 |
Rev X |
40 |
Rev Y |
41 |
Rev Z |
42 |
Analog Output(mA) |
43 |
Analog Output |
44 |
6.1f |
45 |
Product Type |
46 |
Type of Device |
47 |
FL3100H / FlameGard 5 UV/IR Standard |
48 |
FL3100H / FlameGard 5 UV/IR Long Range |
49 |
FL3100H / FlameGard 5 UV/IR Hydrogen |
50 |
FL3101H |
51 |
Warn PPM Level |
52 |
PPM Level to trigger a warning event |
53 |
Alarm PPM Level |
54 |
PPM Level to trigger an alarm event |
55 |
Mid Level |
56 |
PPM Level to trigger a mid level event |
57 |
Cal IO Type |
58 |
Calibrate I/O Type |
59 |
REMOTE CAL LINE |
60 |
MANUAL SOLENOID |
61 |
ARGC MODE |
62 |
Current Range |
63 |
Working current range |
64 |
3.5mA TO 20mA |
65 |
1.25mA TO 20mA |
66 |
Alarm Status High |
67 |
Alarm Status High Byte |
68 |
OFF |
69 |
ON |
70 |
ACCEPTED |
71 |
Alarm Status Low |
72 |
Alarm Status Low Byte |
73 |
Alarm Status Mid |
74 |
Alarm Status Middle Byte |
75 |
Measured Units |
76 |
Units of Measure of the Primary Variable |
77 |
Unit Sensitivity |
78 |
Unit Sensitivity in Hi or Med or Low |
79 |
High, 100% |
80 |
Mid, 75% |
81 |
Low, 50% |
82 |
Warn Latch |
83 |
Warning Relay: Latched or Unlatched |
84 |
UNLATCHED |
85 |
LATCHED |
86 |
Warn Ener/DE |
87 |
Warning Relay: Energized or De-Energized |
88 |
DE-ENERGIZED |
89 |
ENERGIZED |
90 |
Alarm Latch |
91 |
Alarm Relay: Latched or Unlatched |
92 |
Alarm Ener/DE |
93 |
Alarm Relay: Energized or De-Energized |
94 |
Sensor Life |
95 |
100% When Reseted |
96 |
RTClock: Date |
97 |
Real Time Clock Date |
98 |
RTClock: Hour |
99 |
Real Time Clock Hour |
100 |
RTClock: Minute |
101 |
Real Time Clock Minute |
102 |
RTClock: Seconds |
103 |
Real Time Clock Seconds |
104 |
Total Seconds |
105 |
Run Time Clock Seconds |
106 |
Mode |
107 |
Operating Mode Value |
108 |
START UP |
109 |
WARN NON-LATCHING |
110 |
WARN & ALARM NON-LATCHING |
111 |
WARN LATCHING |
112 |
ALARM LATCHING |
113 |
WARN & ALARM LATCHING |
114 |
READY STATE |
115 |
UV ONLY FIRE |
116 |
IR ONLY FIRE |
117 |
ALARM TEST |
118 |
COPM FAULT DETECTED |
119 |
Sub Mode |
120 |
|
121 |
APPLY GAS |
122 |
REMOVE GAS |
123 |
GAS BEING READ |
124 |
APPLY GAS |
125 |
SENSOR LIFE RESET |
126 |
Power Cycle |
127 |
Power Has Been Cycled |
128 |
NO CYCLE |
129 |
YES CYCLED |
130 |
Percent LEL |
131 |
Percent of LEL Detected |
132 |
Full Scale |
133 |
Full SCale Value |
134 |
PPM Detected |
135 |
Parts Per Million Detected |
136 |
Event Happened Flag |
137 |
At least one event happened |
138 |
Sensor Voltage(mV) |
139 |
Sensor Voltage in milivolt |
140 |
Alarm Delay |
141 |
Alarm Delay in Seconds |
142 |
4 sec |
143 |
8 sec |
144 |
2 sec |
145 |
10 sec |
146 |
Calibration Level |
147 |
Calibration Level in % of Full Scale |
148 |
Config Byte |
149 |
Configuration Byte |
150 |
|
151 |
DIP SW Override Status |
152 |
Status of DIP switch |
153 |
Disallow |
154 |
Allow |
155 |
Units Online |
156 |
Number of Units ONLINE |
157 |
Number of Votes Received |
158 |
Configuration Flags for the instrument |
159 |
Reset Alarm/Relay |
160 |
Reset Alarm/Relay Latching |
161 |
Abort Alarm Test |
162 |
Abort Alarm Test Operation |
163 |
Alarm Test |
164 |
Reset COPM Fault |
165 |
Warn: Total |
166 |
The total number of Warning Events currently logged in the system |
167 |
Alarm: Total |
168 |
The total number of Alarm Events currently logged in the system |
169 |
Fault: Total |
170 |
The total number of Fault Events currently logged in the system |
171 |
Maint: Total |
172 |
The total number of Maintenance Events currently logged in the system |
173 |
Calib: Total |
174 |
The total number of Calibrate Events currently logged in the system |
175 |
Event Logging Menu |
176 |
Warn Log Menu |
177 |
Alarm Log Menu |
178 |
Fault Log Menu |
179 |
Maintenance Log Menu |
180 |
Error/Status |
181 |
Prioritized Unit Faults |
182 |
INTERNAL ERROR |
183 |
IR COPM FAULT |
184 |
UV COPM FAULT |
185 |
IR/UV COPM FAULT |
186 |
LOW SUPPLY VOLTAGE |
187 |
RAM ERROR |
188 |
EEPROM ERROR |
189 |
FLASH ERROR |
190 |
Current ERROR |
191 |
UV 10 MINUTES |
192 |
RESET LINE SHORTED |
193 |
MULTIPLE FAULTS |
194 |
Error Bits |
195 |
Bit Mapped Unit Faults or Errors in Decimal |
196 |
Unit Temperature |
197 |
The internal temperature at the microprocessor chip |
198 |
Line Voltage(V) |
199 |
Supply Voltage |
200 |
Clear Events |
201 |
Clear the Event Counter |
202 |
Clear Config Changed Flag |
203 |
Clear the Config Changed Flag |
204 |
Running Time |
205 |
Number of Seconds that unit has been running |
206 |
Event Date |
207 |
Date of the Warning Event |
208 |
Event Hour |
209 |
Hour of the Warning Event |
210 |
Event Min |
211 |
Minute of the Warning Event |
212 |
Event Sec |
213 |
Second of the Warning Event |
214 |
Select Log Index |
215 |
The Event Log Item to be Displayed |
216 |
Date of the Alarm Event |
217 |
Hour of the Alarm Event |
218 |
Event Minute |
219 |
Minute of the Alarm Event |
220 |
Event Second |
221 |
Second of the Alarm Event |
222 |
Date of the Fault Event |
223 |
Hour of the Fault Event |
224 |
Minute of the Fault Event |
225 |
Second of the Fault Event |
226 |
Event Cause |
227 |
Cause of the Fault Event |
228 |
INTERNAL ERROR |
229 |
Current Fault |
230 |
Date of the Maintenance Event |
231 |
Hour of the Maintenance Event |
232 |
Minute of the Maintenance Event |
233 |
Second of the Maintenance Event |
234 |
Cause of the Maintenance Event |
235 |
ALARM TEST |
236 |
UV Counts |
237 |
UV Signal Counts |
238 |
UV COPM Fault |
239 |
UV COPM Counts |
240 |
IR Counts |
241 |
IR Signal Counts for FL3100H/FlameGard 5 UV/IR Only |
242 |
IR COPM Fault |
243 |
IR COPM Counts for FL3100H/FlameGard 5 UV/IR Only |
244 |
IR Signal Counts |
245 |
IR COPM Counts |
246 |
Reserved word for cmd 205 |
247 |
PV Analog Channel Saturated |
248 |
PV Analog Channel Fixed |
249 |
Enable on token-passing data link layer only |
250 |
Enable on TDMA data link layer only |
251 |
Enable on both TDMA and token-passing data link layer |
252 |
Wireless |
253 |
WirelessHART Device |
254 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
255 |
Primary |
256 |
Primary Analog Channel |
257 |
Secondary |
258 |
Secondary Analog Channel |
259 |
Tertiary |
260 |
Tertiary Analog Channel |
261 |
Quaternary |
262 |
Quaternary Analog Channel |
263 |
Quinary |
264 |
Quinary Analog Channel |
265 |
Critical Power Failure |
266 |
Lock all |
267 |
Trim not supported |
268 |
Configuration cannot be changed |
269 |
Locked by gateway |
270 |
Analog Input Channel |
271 |
Analog Output Channel |
272 |
Secondary Analog Channel Saturated |
273 |
Tertiary Analog Channel Saturated |
274 |
Quaternary Analog Channel Saturated |
275 |
Quinary Analog Channel Saturated |
276 |
Secondary Analog Channel Fixed |
277 |
Tertiary Analog Channel Fixed |
278 |
Quaternary Analog Channel Fixed |
279 |
Quinary Analog Channel Fixed |
280 |
8u |