0 |
FLUXUS |
1 |
FLEXIM |
2 |
Upper transducer limit |
3 |
Lower transducer limit |
4 |
Minimum span |
5 |
Sensor serial number |
6 |
dummy var |
7 |
|
8 |
Damping Value |
9 |
Damping Value for all device variables |
10 |
.3f |
11 |
8.3f |
12 |
Fixed Current |
13 |
Fixed Current - Used to hold the current output to a fixed value. Use a value of 0,0mA to exit fixed current mode. |
14 |
5.2f |
15 |
Error Value Delay |
16 |
Fluxus serial no |
17 |
Fluxus serial number |
18 |
Fluxus firmware version |
19 |
HART-Gateway serial no |
20 |
HART-Gateway serial number |
21 |
HART-Gateway major firmware version |
22 |
HART-Gateway sub firmware version |
23 |
Device Variable Code |
24 |
ChA Temp Fluid |
25 |
Classification |
26 |
Temp Fluid PDQ |
27 |
Temp Fluid LS |
28 |
7d |
29 |
ChA Temperature Fluid |
30 |
Channel A Temperature Fluid |
31 |
ChA Temp Inlet |
32 |
Temp Inlet PDQ |
33 |
ChA Temperature Inlet |
34 |
Channel A Temperature Inlet |
35 |
ChA Pres Fluid |
36 |
Pres Fluid PDQ |
37 |
ChA Pressure Fluid |
38 |
Channel A Pressure Fluid |
39 |
ChA Pres Inlet |
40 |
Pres Inlet PDQ |
41 |
ChA Pressure Inlet |
42 |
Channel A Pressure Inlet |
43 |
ChA Signal Amplitude |
44 |
Signal Amplitude unit |
45 |
Signal Ampl PDQ |
46 |
Channel A Signal Amplitude |
47 |
ChA Sound Velocity |
48 |
Sound Velocity PDQ |
49 |
Channel A Sound Velocity |
50 |
ChA Flow Velocity |
51 |
Flow Velocity PDQ |
52 |
Channel A Flow Velocity |
53 |
ChA Volume Flow |
54 |
Volume Flow Unit |
55 |
Volume Flow PDQ |
56 |
Channel A Volume Flow |
57 |
ChA Vol Flow Pos Tot |
58 |
Volume Flow Pos Tot PDQ |
59 |
ChA Volume Flow Pos Tot |
60 |
Channel A Volume Flow Positive Totalizer |
61 |
ChA Vol Flow Neg Tot |
62 |
Volume Flow Neg Tot PDQ |
63 |
ChA Volume Flow Neg Tot |
64 |
Channel A Volume Flow Negative Totalizer |
65 |
ChA Std Vol Flow |
66 |
Standardized Volume Flow PDQ |
67 |
ChA Std Volume Flow |
68 |
Channel A Standardized Volume Flow |
69 |
ChA Std Vol Flow Pos Tot |
70 |
Standardized Volume Flow Pos Tot PDQ |
71 |
ChA Std Volume Flow Pos Tot |
72 |
Channel A Standardized Volume Flow Positive Totalizer |
73 |
ChA Std Vol Flow Neg Tot |
74 |
Standardized Volume Flow Neg Tot PDQ |
75 |
ChA Std Volume Flow Neg Tot |
76 |
Channel A Standardized Volume Flow Negative Totalizer |
77 |
ChA Mass Flow |
78 |
Mass Flow Pos Tot PDQ |
79 |
Channel A Mass Flow |
80 |
ChA Mass Flow Pos Tot |
81 |
Channel A Mass Flow Positive Totalizer |
82 |
ChA Mass Flow Neg Tot |
83 |
Mass Flow Neg Tot PDQ |
84 |
Channel A Mass Flow Negative Totalizer |
85 |
ChA Heat Flow |
86 |
Heat Flow unit |
87 |
Mega british thermal unit per hour (MBTU) |
88 |
Heat Flow PDQ |
89 |
Channel A Heat Flow |
90 |
ChA Heat Flow Pos Tot |
91 |
Heat Flow Tot unit |
92 |
MWh |
93 |
Mega watt hours. |
94 |
MBTU |
95 |
Mega british thermal unit |
96 |
Heat Flow Pos Tot PDQ |
97 |
Channel A Heat Flow Positive Totalizer |
98 |
ChA Heat Flow Neg Tot |
99 |
Heat Flow Neg Tot PDQ |
100 |
Channel A Heat Flow Negative Totalizer |
101 |
ChA Concentration |
102 |
Concentration PDQ |
103 |
Channel A Concentration |
104 |
ChA SNR |
105 |
SNR unit |
106 |
dB |
107 |
Decibel |
108 |
SNR PDQ |
109 |
Channel A SNR |
110 |
ChA SCNR |
111 |
SCNR unit |
112 |
SCNR PDQ |
113 |
Channel A SCNR |
114 |
ChB Temp Fluid |
115 |
ChB Temperature Fluid |
116 |
Channel B Temperature Fluid |
117 |
ChB Temp Inlet |
118 |
ChB Temperature Inlet |
119 |
Channel B Temperature Inlet |
120 |
ChB Pres Fluid |
121 |
ChB Pressure Fluid |
122 |
Channel B Pressure Fluid |
123 |
ChB Pres Inlet |
124 |
ChB Pressure Inlet |
125 |
Channel B Pressure Inlet |
126 |
ChB Signal Amplitude |
127 |
Channel B Signal Amplitude |
128 |
ChB Sound Velocity |
129 |
Channel B Sound Velocity |
130 |
ChB Flow Velocity |
131 |
Channel B Flow Velocity |
132 |
ChB Volume Flow |
133 |
Channel B Volume Flow |
134 |
ChB Vol Flow Pos Tot |
135 |
ChB Volume Flow Pos Tot |
136 |
Channel B Volume Flow Positive Totalizer |
137 |
ChB Vol Flow Neg Tot |
138 |
ChB Volume Flow Neg Tot |
139 |
Channel B Volume Flow Negative Totalizer |
140 |
ChB Std Vol Flow |
141 |
ChB Std Volume Flow |
142 |
Channel B Standardized Volume Flow |
143 |
ChB Std Vol Flow Pos Tot |
144 |
ChB Std Volume Flow Pos Tot |
145 |
Channel B Standardized Volume Flow Positive Totalizer |
146 |
ChB Std Vol Flow Neg Tot |
147 |
ChB Std Volume Flow Neg Tot |
148 |
Channel B Standardized Volume Flow Negative Totalizer |
149 |
ChB Mass Flow |
150 |
Channel B Mass Flow |
151 |
ChB Mass Flow Pos Tot |
152 |
Channel B Mass Flow Positive Totalizer |
153 |
ChB Mass Flow Neg Tot |
154 |
Channel B Mass Flow Negative Totalizer |
155 |
ChB Heat Flow |
156 |
Channel B Heat Flow |
157 |
ChB Heat Flow Pos Tot |
158 |
Channel B Heat Flow Positive Totalizer |
159 |
ChB Heat Flow Neg Tot |
160 |
Channel B Heat Flow Negative Totalizer |
161 |
ChB Concentration |
162 |
Channel B Concentration |
163 |
ChB SNR |
164 |
Channel B SNR |
165 |
ChB SCNR |
166 |
Channel B SCNR |
167 |
ChZ Temp Fluid |
168 |
ChZ Temperature Fluid |
169 |
Channel Z Temperature Fluid |
170 |
ChZ Temp Inlet |
171 |
ChZ Temperature Inlet |
172 |
Channel Z Temperature Inlet |
173 |
ChZ Pres Fluid |
174 |
ChZ Pressure Fluid |
175 |
Channel Z Pressure Fluid |
176 |
ChZ Pres Inlet |
177 |
ChZ Pressure Inlet |
178 |
Channel Z Pressure Inlet |
179 |
ChZ Signal Amplitude |
180 |
Channel Z Signal Amplitude |
181 |
ChZ Sound Velocity |
182 |
Channel Z Sound Velocity |
183 |
ChZ Flow Velocity |
184 |
Channel Z Flow Velocity |
185 |
ChZ Volume Flow |
186 |
Channel Z Volume Flow |
187 |
ChZ Vol Flow Pos Tot |
188 |
ChZ Volume Flow Pos Tot |
189 |
Channel Z Volume Flow Positive Totalizer |
190 |
ChZ Vol Flow Neg Tot |
191 |
ChZ Volume Flow Neg Tot |
192 |
Channel Z Volume Flow Negative Totalizer |
193 |
ChZ Std Vol Flow |
194 |
ChZ Std Volume Flow |
195 |
Channel Z Standardized Volume Flow |
196 |
ChZ Std Vol Flow Pos Tot |
197 |
ChZ Std Volume Flow Pos Tot |
198 |
Channel Z Standardized Volume Flow Positive Totalizer |
199 |
ChZ Std Vol Flow Neg Tot |
200 |
ChZ Std Volume Flow Neg Tot |
201 |
Channel Z Standardized Volume Flow Negative Totalizer |
202 |
ChZ Mass Flow |
203 |
Channel Z Mass Flow |
204 |
ChZ Mass Flow Pos Tot |
205 |
Channel Z Mass Flow Positive Totalizer |
206 |
ChZ Mass Flow Neg Tot |
207 |
Channel Z Mass Flow Negative Totalizer |
208 |
ChZ Heat Flow |
209 |
Channel Z Heat Flow |
210 |
ChZ Heat Flow Pos Tot |
211 |
Channel Z Heat Flow Positive Totalizer |
212 |
ChZ Heat Flow Neg Tot |
213 |
Channel Z Heat Flow Negative Totalizer |
214 |
ChZ Concentration |
215 |
Channel Z Concentration |
216 |
ChY Temp Fluid |
217 |
ChY Temperature Fluid |
218 |
Channel Y Temperature Fluid |
219 |
ChY Temp Inlet |
220 |
ChY Temperature Inlet |
221 |
Channel Y Temperature Inlet |
222 |
ChY Pres Fluid |
223 |
ChY Pressure Fluid |
224 |
Channel Y Pressure Fluid |
225 |
ChY Pres Inlet |
226 |
ChY Pressure Inlet |
227 |
Channel Y Pressure Inlet |
228 |
ChY Signal Amplitude |
229 |
Channel Y Signal Amplitude |
230 |
ChY Sound Velocity |
231 |
Channel Y Sound Velocity |
232 |
ChY Flow Velocity |
233 |
Channel Y Flow Velocity |
234 |
ChY Volume Flow |
235 |
Channel Y Volume Flow |
236 |
ChY Vol Flow Pos Tot |
237 |
ChY Volume Flow Pos Tot |
238 |
Channel Y Volume Flow Positive Totalizer |
239 |
ChY Vol Flow Neg Tot |
240 |
ChY Volume Flow Neg Tot |
241 |
Channel Y Volume Flow Negative Totalizer |
242 |
ChY Std Vol Flow |
243 |
ChY Std Volume Flow |
244 |
Channel Y Standardized Volume Flow |
245 |
ChY Std Vol Flow Pos Tot |
246 |
ChY Std Volume Flow Pos Tot |
247 |
Channel Y Standardized Volume Flow Positive Totalizer |
248 |
ChY Std Vol Flow Neg Tot |
249 |
ChY Std Volume Flow Neg Tot |
250 |
Channel Y Standardized Volume Flow Negative Totalizer |
251 |
ChY Mass Flow |
252 |
Channel Y Mass Flow |
253 |
ChY Mass Flow Pos Tot |
254 |
Channel Y Mass Flow Positive Totalizer |
255 |
ChY Mass Flow Neg Tot |
256 |
Channel Y Mass Flow Negative Totalizer |
257 |
ChY Heat Flow |
258 |
Channel Y Heat Flow |
259 |
ChY Heat Flow Pos Tot |
260 |
Channel Y Heat Flow Positive Totalizer |
261 |
ChY Heat Flow Neg Tot |
262 |
Channel Y Heat Flow Negative Totalizer |
263 |
ChY Concentration |
264 |
Channel Y Concentration |
265 |
Totalizer Reset - Channel ID |
266 |
It is possible to choose the totalizer of a physical (A, B, C, D), virtual (Z, Y). It has to be written the ASCII value of the channel ID (example: channel A = 65 = 0x41). |
267 |
Choose Channel |
268 |
Channel A |
269 |
Channel B |
270 |
Channel Z |
271 |
Channel Y |
272 |
Totalizer Reset - Totalizer ID |
273 |
It is possible to reset only positive ('+'), only negative ('-') or both ('*') totalizers. As at the channel ID it is necessary to specify the ASCII value of '+' (43 = 0x2B), '-' (45 = 0x2D) or '*' (42 = 0x2A). |
274 |
Choose Totalizer |
275 |
Positive Totalizer |
276 |
Negative Totalizer |
277 |
All Totalizer |
278 |
ChA Fluid Temperature |
279 |
ChA Inlet Temperature |
280 |
ChA Fluid Pressure |
281 |
ChA Inlet Pressure |
282 |
ChA Standardized Volume Flow |
283 |
ChB Fluid Temperature |
284 |
ChB Inlet Temperature |
285 |
ChB Fluid Pressure |
286 |
ChB Inlet Pressure |
287 |
ChB Standardized Volume Flow |
288 |
ChZ Fluid Temperature |
289 |
ChZ Inlet Temperature |
290 |
ChZ Fluid Pressure |
291 |
ChZ Inlet Pressure |
292 |
ChZ Standardized Volume Flow |
293 |
ChY Fluid Temperature |
294 |
ChY Inlet Temperature |
295 |
ChY Fluid Pressure |
296 |
ChY Inlet Pressure |
297 |
ChY Standardized Volume Flow |
298 |
ChA Positive Volume Flow Totalizer |
299 |
ChA Negative Volume Flow Totalizer |
300 |
ChA Positive Standardized Volume Flow Totalizer |
301 |
ChA Negative Standardized Volume Flow Totalizer |
302 |
ChA Positive Mass Flow Totalizer |
303 |
ChA Negative Mass Flow Totalizer |
304 |
ChA Positive Heat Flow Totalizer |
305 |
ChB Positive Volume Flow Totalizer |
306 |
ChB Negative Volume Flow Totalizer |
307 |
ChB Positive Standardized Volume Flow Totalizer |
308 |
ChB Negative Standardized Volume Flow Totalizer |
309 |
ChB Positive Mass Flow Totalizer |
310 |
ChB Negative Mass Flow Totalizer |
311 |
ChB Positive Heat Flow Totalizer |
312 |
ChZ Positive Volume Flow Totalizer |
313 |
ChZ Negative Volume Flow Totalizer |
314 |
ChZ Positive Standardized Volume Flow Totalizer |
315 |
ChZ Negative Standardized Volume Flow Totalizer |
316 |
ChZ Positive Mass Flow Totalizer |
317 |
ChZ Negative Mass Flow Totalizer |
318 |
ChZ Positive Heat Flow Totalizer |
319 |
ChY Positive Volume Flow Totalizer |
320 |
ChY Negative Volume Flow Totalizer |
321 |
ChY Positive Standardized Volume Flow Totalizer |
322 |
ChY Negative Standardized Volume Flow Totalizer |
323 |
ChY Positive Mass Flow Totalizer |
324 |
ChY Negative Mass Flow Totalizer |
325 |
ChY Positive Heat Flow Totalizer |
326 |
Mainmenue |
327 |
Device Information |
328 |
Serial Numbers / Firmware Versions |
329 |
This page shows serial numbers and firmware versions of Fluxus and HART-Gateway. |
330 |
Fluxus serial number (16 ASCII chars) |
331 |
Fluxus firmware version (16 ASCII chars) |
332 |
Fluxus firmware version (15 ASCII chars) |
333 |
HART-Gateway firmware version |
334 |
Dynamic Variables |
335 |
Dynamic Variables (PV, SV, TV & QV) |
336 |
Primary Variable (PV) |
337 |
Secondary Variable (SV) |
338 |
Tertiary Variable (TV) |
339 |
Quaternary Variable (QV) |
340 |
All Dynamic Variables |
341 |
All Dynamic Variables At One View |
342 |
PV & Loop |
343 |
Primary Value & Loop |
344 |
PV Range Values |
345 |
PV range values |
346 |
This changes the PV upper & lower range value inside the device |
347 |
Totalizer Reset |
348 |
Reset Totalizer |
349 |
To reset a totalizer, please select a channel and the desired totalizer and then press this 'Reset Totalizer' Button. |
350 |
DynVar Mapping |
351 |
Dynamic Variable Mapping |
352 |
Primary Variable (PV) Mapping |
353 |
Secondary Variable (SV) Mapping |
354 |
Tertiary Variable (TV) Mapping |
355 |
Quaternary Variable (QV) Mapping |
356 |
DynVar Units |
357 |
Dynamic Variable Units |
358 |
PV unit change |
359 |
PV unit change. |
360 |
SV unit change |
361 |
SV unit change. |
362 |
TV unit change |
363 |
TV unit change. |
364 |
QV unit change |
365 |
QV unit change. |
366 |
Other Device Settings |
367 |
Reset the configuration changed flag |
368 |
This resets the configuration changed flag. |
369 |
Apply |
370 |
Press the button to reset the configuration changed flag. |
371 |
Change Message |
372 |
This changes the Message inside the device. |
373 |
Change Tag, Descriptor and Date |
374 |
This changes the Tag, Descriptor & Date inside the device. |
375 |
Change Long-Tag |
376 |
This changes the long-tag inside the device. |
377 |
Change Final Assembly Number |
378 |
Fixed Current Mode |
379 |
This places the Device in Fixed Current Mode. |
380 |
Press the button to place the device in Fixed Current Mode. |
381 |
This sets the Error Value Delay. |
382 |
Number of response preambles |
383 |
This is the count of preambles which is send in every respond. |
384 |
Address config |
385 |
Address Config |
386 |
Set HART specifics to factory default |
387 |
This resets all HART specific settings to factory default |
388 |
Press the button to reset all HART specific settings to fatory default. |
389 |
Common Tables |
390 |
Interoperable * |
391 |
Universal |
392 |
Common Practice |
393 |
Pressure Universal |
394 |
Pressure Common |
395 |
Menu |
396 |
Rosemount Magflow |
397 |
Rosemount Pressure |
398 |
Moore Products |
399 |
Siemens Pressure |
400 |
P2 Common |
401 |
PV |
402 |
Wireless |
403 |
Munge |
404 |
Analytical Oxygen/Combustion/Methane/CO |
405 |
Flow Totalizer - Rate Indicator |
406 |
Flow Variable Area |
407 |
Flow Coriolis Mass |
408 |
Flow Ultrasonic - Gas |
409 |
Flow Ultrasonic - Liquid |
410 |
Level Ultrasonic |
411 |
Level Radar - Microwave |
412 |
Pressure Absolute |
413 |
Level Capacitance |
414 |
Pressure Differential |
415 |
Level Hydrostatic |
416 |
Level |
417 |
Pressure Absolute/Relative |
418 |
Level Microwave |
419 |
Level Radar |
420 |
Level Density - Nuclear |
421 |
Flow Electromagnetic |
422 |
Flow Vortex |
423 |
Flow Magmeter - Rack Version |
424 |
Flow High Performance Magmeter |
425 |
Flow Mass |
426 |
Flow Ultrasonic |
427 |
Flow Magnetic |
428 |
Flow Magnetic - Custody Transfer |
429 |
Flow 2-wire Magnetic |
430 |
Flow Coriolis Mass - Custody Transfer |
431 |
Flow 2-wire Vortex |
432 |
Flow Thermal |
433 |
Temperature Head Mounted |
434 |
Temperature Compact |
435 |
Temperature DIN Rail Mounted |
436 |
Analytical pH |
437 |
Analytical Conductivity - Conductive |
438 |
Analytical Conductivity - Inductive |
439 |
Temperature Sensor |
440 |
Level Servo |
441 |
Temperature DIN Rail |
442 |
Temperature |
443 |
Analytical ORP |
444 |
Analytical pION |
445 |
Analytical IConc |
446 |
Analytical Electrode Conductivity |
447 |
Analytical Toroidal Conductivity |
448 |
Valve Positioner |
449 |
Valve Controller |
450 |
Pressure |
451 |
Pressure Multivariable |
452 |
Analytical pH/ORP |
453 |
Flow Coriolis |
454 |
Analytical Conductivity |
455 |
Valve Positioner/Pneumatic |
456 |
Valve Actuator - Electrical |
457 |
Temperature Dual Input |
458 |
Valve Actuator |
459 |
Analytical Corrosion |
460 |
Analytical Density - Nuclear |
461 |
Level Continuous Gamma |
462 |
Level Laser Ranging |
463 |
Pressure Safety |
464 |
Flow Vortex/Swirl |
465 |
Flow |
466 |
Analytical 4 Electrode Conductivity |
467 |
Analytical 2 Electrode Conductivity |
468 |
Analytical Troidal Conductivity |
469 |
Analytical pH/ORP/pIon/Ion Conc |
470 |
Analytical Oxygen |
471 |
Pressure P, dP + Multivariable |
472 |
Temperature 2-wire |
473 |
Pressure w/ PID |
474 |
Pressure Saturated Steam |
475 |
Analytical Density - Gamma Ray |
476 |
Level Gamma Ray |
477 |
Analytical Weight - Gamma Ray |
478 |
Level w/ Density - Gamma Ray |
479 |
Analytical Motorized Density |
480 |
Flow Multivariable Mass |
481 |
Temperature Multivariable |
482 |
Specialty HART-to-Analog Signal Conv |
483 |
Flow dP |
484 |
Pressure Low Power |
485 |
Pressure Certified SIL2 |
486 |
Interoperable |
487 |
Analytical Density |
488 |
Valve Positioner/Electropneumatic |
489 |
Flow Magnetic Inductive |
490 |
Analytical |
491 |
Analytical Opacity Monitor |
492 |
Analytical Oxygen/Combustion |
493 |
Analytical 2-wire Conductivity |
494 |
Analytical 2-wire Conductivity w/ pure H20 |
495 |
Analytical 2-wire Conductivity w/ % conc |
496 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
497 |
Analytical 2-wire pH/ORP |
498 |
Analytical 2-wire Contacting/Toroidal |
499 |
Analytical Oxygen - High Temperature |
500 |
Analytical Conductivity w/ % conc |
501 |
Analytical pH/ORP/ISE |
502 |
Analytical Amperometric Analyzer |
503 |
Analytical Dual Input Analyzer |
504 |
Pressure Pressure/Level |
505 |
Analytical Consistency |
506 |
Analytical Microwave-Pulp Consistency |
507 |
Analytical Microwave Consistency |
508 |
Valve Digital Positioner |
509 |
Valve Smart Valve Positioner |
510 |
Temperature Differential |
511 |
Analytical Dissolved Oxygen |
512 |
Analytical pH Controller |
513 |
Analytical Conductivity/Resistivity Controller |
514 |
Analytical Conductivity/Resistivity |
515 |
Level Displacement |
516 |
Temperature w/ PID |
517 |
Valve Universal Positioner |
518 |
Level Radar - Reflex |
519 |
Pressure Gauge |
520 |
Pressure Sealed Gauge |
521 |
Valve Digital Positioner w/ PID |
522 |
Valve Intelligent Positioner |
523 |
Analytical Gas Detector |
524 |
Analytical Infrared Gas Detector |
525 |
Analytical Electrochemical Gas Detector |
526 |
Analytical Measuring Instruments |
527 |
Level Magnostrictive |
528 |
Valve On/Off Valve Controller |
529 |
Level Radar - Pulse |
530 |
Level Continuous Capactive |
531 |
Valve Damper Actuator |
532 |
Valve Electric Damper Actuator |
533 |
Flow Electronic |
534 |
Flow Vortex - Multiparameter Mass |
535 |
Analytical UV Flame Detector |
536 |
Analytical UVIR Flame Detector |
537 |
Analytical IR Flame Detector |
538 |
Analytical Fire Detector |
539 |
Analytical Gas Detector Display Interface |
540 |
Analytical Toxic Gas Detector |
541 |
Analytical Flame Detector |
542 |
Level Nuclear |
543 |
Analytical Microwave |
544 |
Analytical Density - Radiometric |
545 |
Level Radiometric |
546 |
Analytical Gas/Steam |
547 |
Level Nucleonic |
548 |
Analytical Blade Consistency |
549 |
Analytical Rotary Consistency |
550 |
Pressure Absolute/Differential |
551 |
Positioner |
552 |
Analytical Combustible Gas Detector |
553 |
Analytical Point Infrared Gas Detector |
554 |
Analytical Multi-Detector Monitor System |
555 |
Valve Positioner/Electro-hydraulic |
556 |
Valve Monitor |
557 |
Enable on token-passing data link layer only |
558 |
Enable on TDMA data link layer only |
559 |
Enable on both TDMA and token-passing data link layer |
560 |
WirelessHART Device |
561 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
562 |
Primary |
563 |
Primary Analog Channel |
564 |
Secondary |
565 |
Secondary Analog Channel |
566 |
Tertiary |
567 |
Tertiary Analog Channel |
568 |
Quaternary |
569 |
Quaternary Analog Channel |
570 |
Quinary |
571 |
Quinary Analog Channel |
572 |
Critical Power Failure |
573 |
Lock all |
574 |
Trim not supported |
575 |
Configuration cannot be changed |
576 |
Locked by gateway |
577 |
Analog Input Channel |
578 |
Analog Output Channel |
579 |
Secondary Analog Channel Saturated |
580 |
Tertiary Analog Channel Saturated |
581 |
Quaternary Analog Channel Saturated |
582 |
Quinary Analog Channel Saturated |
583 |
Secondary Analog Channel Fixed |
584 |
Tertiary Analog Channel Fixed |
585 |
Quaternary Analog Channel Fixed |
586 |
Quinary Analog Channel Fixed |
587 |
Simulation active |
588 |
The device is in simulation mode and the level output is not representative of the process. |
589 |
Non-Volatile memory failure |
590 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
591 |
Volatile memory error |
592 |
The RAM memory check is invalid or maybe corrupt |
593 |
Watchdog reset executed |
594 |
A watchdog reset has been performed |
595 |
Voltage conditions out of range |
596 |
A voltage condition is outside its allowable range |
597 |
Environmental conditions out of range |
598 |
An internal or environmental condition is beyond acceptable limits. |
599 |
Electronic failure |
600 |
A hardware problem not related to the sensor has been detected. |
601 |
Subdevice list changed |
602 |
Duplicate master detected |
603 |
Capacity Denied |
604 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
605 |
Bandwidth allocation pending |
606 |
Block transfer pending |
607 |
Continuous |
608 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
609 |
Window |
610 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
611 |
Rising |
612 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
613 |
Falling |
614 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
615 |
On-change |
616 |
The Burst Message is triggered when any value in the message changes. |
617 |
Battery life |
618 |
Percent range |
619 |
Loop current |
620 |
Primary variable |
621 |
Secondary variable |
622 |
Tertiary variable |
623 |
Quaternary variable |
624 |
Off |
625 |
Enable event notification on token-passing data link layer |
626 |
Enable event notification on TDMA data link layer |
627 |
Enable event notification on TDMA and token-passing data link layer |
628 |
Configuration changed event pending |
629 |
Device status event pending |
630 |
More status available event pending |
631 |
Disable |
632 |
Enable single data point trending |
633 |
Enable filtered trending |
634 |
The sample is filtered using a time constant equal to one-third the trend sample period |
635 |
Enable average trending |
636 |
The value obtained by dividing the sum of all samples in the period by the total number of samples |
637 |
Read receive time |
638 |
Write date and time |
639 |
Non-Volatile Clock |
640 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
641 |
Clock Uninitialized |
642 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
643 |
Line Power |
644 |
Device is powered via a hardwired connection to a plant power source. |
645 |
Battery Power |
646 |
Device operates solely of its (internal) battery. |
647 |
Recharg.B./Power Sc. |
648 |
Rechargeable battery power or power scavenging. The device has a short-term supply of energy (must be at least one hour) that is continuously being replenished. The device's power is being replenished by harvesting and converting energy from the environment surrounding the device (e.g. solar, vibration, heat). |
649 |
Idle |
650 |
Active search |
651 |
Looking for neighbors. |
652 |
Negotiating |
653 |
Quarantined |
654 |
Operational |
655 |
Suspended |
656 |
Deep sleep |
657 |
Ultra-low power |
658 |
Wireless Signal Found |
659 |
Network packets have been recognized |
660 |
Wireless Signal Identified |
661 |
Wireless Time Synchronized |
662 |
WirelessHart Signal Identified |
663 |
Network Admission Requested |
664 |
Set on transmission of first join request |
665 |
Join Retrying |
666 |
Set after the first join request retry (i.e. when number of join requests > 2). Cleared when device is authenticated or when Active Search started. |
667 |
Join Failed |
668 |
Set on transition from Active Search mode to Deep Sleep mode. Cleared on transition from Deep Sleep to Active Search. |
669 |
Network Security Clearance Granted |
670 |
Network Manager Session Established |
671 |
Network Joined |
672 |
Network Joined. Normal superframe and links obtained. |
673 |
Network Bandwidth Requested |
674 |
Negotiating Network Properties. Gateway session obtained. |
675 |
Join Complete |
676 |
Normal operating mode. |
677 |
None |
678 |
No restrictions |
679 |
SI Only |
680 |
Restricted to SI Unit codes only |
681 |
Open - accept all devices |
682 |
Use Whitelist for access |
683 |
Use Blacklist |
684 |
Use Whitelist and Blacklist |
685 |
Lockdown - disable join links |
686 |
Process automation device |
687 |
Discrete device |
688 |
Hybrid:Process automation+discrete |
689 |
I/O System |
690 |
WirelessHART Process automation device |
691 |
WirelessHART Discrete device |
692 |
WirelessHART Process automation+discrete |
693 |
WirelessHART Gateway |
694 |
WirelessHART Access point |
695 |
WirelessHART Process adapter |
696 |
WirelessHART Discrete adapter |
697 |
WirelessHART enabled handheld/portable maintenance tool |
698 |
Don't attempt to join |
699 |
Join now |
700 |
Attempt to join immediately on powerup or reset |
701 |
US |
702 |
United States of America |
703 |
JP |
704 |
Japan |
705 |
DE |
706 |
Germany |
707 |
FR |
708 |
France |
709 |
ES |
710 |
Spain |
711 |
RU |
712 |
Russian Federation |
713 |
CN |
714 |
People's Republic of China |
715 |
Nominal |
716 |
Device Power Status is nominal |
717 |
Low |
718 |
Device Power Status is low |
719 |
Critically Low |
720 |
Device Power Status is critically low |
721 |
Recharging - Low |
722 |
Recharging - High |
723 |
Secondary Master |
724 |
Primary Master |
725 |
PV Analog Channel Saturated |
726 |
PV Analog Channel Fixed |
727 |
Device Profile |
728 |
Device Diagnostic Status 0 |
729 |
Device Diagnostic Status 1 |
730 |
I/O and Subdevice Status |
731 |
WirelessHART Status |
732 |
Time Set Option |
733 |
Real Time Clock Flags |
734 |
Country |
735 |
Country of intended device installation |
736 |
SI Unit Control |
737 |
Indicates if device should only display SI unit codes |
738 |
Burst Trigger Units |
739 |
Burst Trigger Class |
740 |
Wired HART Enabled |
741 |
Enabled on Wired HART device connection only |
742 |
Wireless HART Enabled |
743 |
Enabled on WirelessHART device connection only |
744 |
Both Wired and WirelessHart Enabled |
745 |
Enabled on both Wired and WirelessHART connections |
746 |
Burst Msg Trigger Mode |
747 |
Event Status |
748 |
Event Notification Control |
749 |
Operate mode Mask |
750 |
Not Defined |
751 |
Power Source |
752 |
Power source of the device |
753 |
Wireless Mode |
754 |
Join Status |
755 |
The current location in the joining sequence of operations. |
756 |
Network Access Mode |
757 |
Join Mode |
758 |
Power Status |
759 |
Power status of the device |
760 |
Master Mode |
761 |
This sets the I/O System's Data Link Layer operation on all channels as either primary or secondary master mode. |
762 |
Trend Units |
763 |
Trend Device Variable Unit Code |
764 |
Trend Classification |
765 |
Trend Device Variable Classification |
766 |
Trend Control |
767 |
Device Status Mask |
768 |
Ext dev status Mask |
769 |
Device Diagnostic Status 0 Mask |
770 |
Device Diagnostic Status 1 Mask |
771 |
Device Diagnostic Status 2 Mask |
772 |
Device Diagnostic Status 3 Mask |
773 |
AO saturated Mask |
774 |
AO fixed Mask |
775 |
Latched Device Status |
776 |
Latched Ext dev status |
777 |
Latched Operate Mode |
778 |
Latched Device Diagnostic Status 0 |
779 |
Latched Device Diagnostic Status 1 |
780 |
Latched Device Diagnostic Status 2 |
781 |
Latched Device Diagnostic Status 3 |
782 |
Latched AO saturated |
783 |
Latched AO fixed |
784 |
Wireless Module Device Type |
785 |
Device type of the Wireless Radio |
786 |
Wireless Module Manufacturer ID |
787 |
Manufacturer of the Wireless Radio contained in this device |
788 |
Subdevice Device Type |
789 |
Device type of the subdevice attached to this system. |
790 |
Subdevice Manufacturer Id |
791 |
Manufacturer of the subdevice attached to this system. |
792 |
Time Stamp |
793 |
Relative time value on network |
794 |
8u |
795 |
Dynamic Variables Returned for Device Variables |
796 |
Command Response Truncated |
797 |
Configuration Change Counter Mismatch |
798 |
Status bytes mismatch |
799 |
Device Variable |
800 |
Variable to trim |
801 |
By pressing the "OK" button, you will reset the selected totalizer! |
802 |
Select Channel ID and Totalizer ID! |
803 |
By pressing the "OK" button, you will switch to the fixed current mode! |
804 |
Returning fld dev to original output |
805 |
NOTE-Loop returned to automatic control |
806 |
Reset HART specific settings to fatory default?
It could be necessary to restart the device description,
if the host system do not react or react unusually. |
807 |
Reset HART specific settings. |