0 |
TMD832 |
1 |
Set to nearest possible value |
2 |
Invalid value selection |
3 |
.2f |
4 |
Error code |
5 |
Diagnostic Code that has Field Device status information relating to failure/warning. |
6 |
ERR./WARN.Nø000 - No error(s) or warning(s) detected |
7 |
ERR.Nø011 - Hardware error |
8 |
ERR.Nø012 - Alarm: overflow - Input signal too high |
9 |
ERR.Nø013 - Alarm: overflow - Input signal too low |
10 |
WARN.Nø201 - Alarm: overflow - Measured value too high |
11 |
WARN.Nø202 - Alarm: overflow - Measured value too low |
12 |
WARN.Nø203 - Up/Down-load active |
13 |
WARN.Nø204 - Default active |
14 |
deg.C |
15 |
deg.F |
16 |
mV |
17 |
ohm |
18 |
sec |
19 |
|
20 |
AO |
21 |
.3f |
22 |
Output value |
23 |
.1f |
24 |
Sensor input |
25 |
Lists the type of sensor supported. For user selection. |
26 |
80 mV FS |
27 |
400 ohms FS |
28 |
4000 ohms FS |
29 |
Pt 100 |
30 |
Ni 100 |
31 |
Pt 1000 |
32 |
Tc B |
33 |
Tc C |
34 |
Tc D |
35 |
Tc E |
36 |
Tc J |
37 |
Tc K |
38 |
Tc L |
39 |
Tc N |
40 |
Tc R |
41 |
Tc S |
42 |
Tc T |
43 |
Tc U |
44 |
Select mV |
45 |
Select 400 |
46 |
Select 4000 |
47 |
Select page |
48 |
PV Value |
49 |
Temp. compensation |
50 |
For TC only. Temperature Compensation Measured Value used for cold junction reference point compensation, if INTERNAL is selected. |
51 |
Input filter |
52 |
Filter Value - Damping time constant applied to both the Digital Value representetion and Analog Value of the respective Analog Output. The units of this variable are always in seconds. |
53 |
2.0f |
54 |
6.0f |
55 |
RJ mode |
56 |
For TC input only. Ambient temperature compensation existing at cold junction point is normally provided by an 'INTERNAL' measuring sensor. However the user may choose to set this temp. compensation value as an 'EXTERNAL'fixed parameters. |
57 |
INTERNAL |
58 |
EXTERNAL |
59 |
RJ external value |
60 |
If the has selected to choose the external compensation functionality, then a corresponding value must be inserted in this location. Value may range from -50 to +94. |
61 |
6.2f |
62 |
Bias input 1 |
63 |
Offset added to the input signal to compensate for installation where the sensor cannot be placed exactly where the measurementis needed, or to correct for drifts. Value may range from -10.0 to +10.0. |
64 |
Measuring unit |
65 |
Dir./rev. action |
66 |
The output signal can have a direct action (increases when the process variable increases) or reverse action (increases when the process variable decreases). For user selection. |
67 |
Dir. action |
68 |
Rev. action |
69 |
Value for 4 mA |
70 |
7.2f |
71 |
Value for 20 mA |
72 |
R/RTD connection |
73 |
For RTD input only. Lists the type of sensor connection supprted. For user selection. |
74 |
2 wire |
75 |
3 wire |
76 |
4 wire |
77 |
R/RTD 2 wire comp. |
78 |
For 2 wire R or RTD input only. The value to be inserted is the resistence of the connection wires, expressed in ohm. Value may range from 0 to 30. |
79 |
Sensor error |
80 |
When the transmitter detects a failure output signal is forced to a predefined value. For user selection: LOW=down_scale, HIGH=up_scale. |
81 |
Low |
82 |
High |
83 |
Last diagnostic |
84 |
Last detected diagnostic code. |
85 |
Default values |
86 |
Matrix parameters reset function default of transmitter data according to the manual. |
87 |
Tag number |
88 |
Software version |
89 |
Information related to the instrument software version, assigned by the Factory for traceability purposes. |
90 |
Modification n. |
91 |
Information related to the complete instrument - hardware and software - version, assigned by the Factory for traceability purposes. |
92 |
Serial number |
93 |
Instrument serial number assigned by the Factory for traceability purposes. |
94 |
Filter |
95 |
AO |
96 |
D/R |
97 |
Err |
98 |
fnctn |
99 |
20 |
100 |
4 |
101 |
span |
102 |
T. comp. |
103 |
RJ unit |
104 |
mode |
105 |
Ext val. |
106 |
PV variables |
107 |
PV sensor |
108 |
OFFLINE |
109 |
Matrix parameters |
110 |
Working parameters |
111 |
Calibration Chan.1 |
112 |
Output calibration |
113 |
Service |
114 |
|
115 |
FMU860 |
116 |
DT |
117 |
DVC |
118 |
FCX |
119 |
AS800 |
120 |
340T |
121 |
340C |
122 |
344 |
123 |
Siemens Micro K |
124 |
SITRANS L |
125 |
SIPAN PH |
126 |
SITRANS P |
127 |
75SMT |
128 |
UNIDELTA |
129 |
8320 |
130 |
SX5100 |
131 |
TSV175 |
132 |
DMU |
133 |
3780 |
134 |
BM70 |
135 |
8u |