0 |
6u |
1 |
PROWIRL77 |
2 |
ERROR 101: Sensor defective |
3 |
ERROR 102: EE-Prom Hardware Error |
4 |
ERROR 102: EE-Prom Checksum Error |
5 |
ERROR 103: Com. Error - Communication Error with Pre-amplifier |
6 |
WARNING 205: Current output simulation active |
7 |
WARNING 203: Current out of range |
8 |
.7g |
9 |
8.7g |
10 |
.2f |
11 |
Flow unit |
12 |
m3/s |
13 |
m3/min |
14 |
m3/h |
15 |
ACF/s |
16 |
ACF/min |
17 |
ACF/h |
18 |
usg/s |
19 |
usg/min |
20 |
usg/h |
21 |
user |
22 |
Tot. unit |
23 |
Totalizer Unit- Engineering units that the totalizer will be displayed with. |
24 |
m3 |
25 |
ACF |
26 |
usg |
27 |
PV Damping |
28 |
.1f |
29 |
5.1f |
30 |
Status: normal |
31 |
Status: err/warn |
32 |
Frequency unit |
33 |
|
34 |
unit_0 |
35 |
VF |
36 |
Vortex Frequency - Vortex frequency measured with sensor |
37 |
Tot |
38 |
Totalizer - Totalized Flow |
39 |
Flow user unit |
40 |
Flow user unit - User defined conversion factor to convert flow values from dm3/s into another unit |
41 |
.4g |
42 |
8.4g |
43 |
Tot. user unit |
44 |
Tot. user unit - User defined conversion factor to convert volume values from dm3 into another unit |
45 |
AO Alarm type |
46 |
Display mode |
47 |
Display mode - Defines the parameter which will be displayed on the local LC-display |
48 |
Percent |
49 |
Flow rate |
50 |
Totalizer |
51 |
Totalizer ovl |
52 |
Customer Code |
53 |
Customer Code - Safety code for local access and write protect for HART. |
54 |
4d |
55 |
Code entry |
56 |
Safety code entry field for local access and write protect for HART. Entering correct code disables write protection, entering -1 enables write protection. |
57 |
Software Version |
58 |
SW mainboard - Software version of mainboard |
59 |
Hardware Version |
60 |
HV mainboard - Hardware version of mainboard |
61 |
Fluid |
62 |
Define application: gas/steam or liquid |
63 |
Liquid |
64 |
Gas/Steam |
65 |
DN |
66 |
DN - Defines the nominal diameter of the pipe |
67 |
15 (.5 in) |
68 |
25 (1 in) |
69 |
40 (1.5 in) |
70 |
50 (2 in) |
71 |
80 (3 in) |
72 |
100 (4 in) |
73 |
150 (6 in) |
74 |
200 (8 in) |
75 |
250 (10 in) |
76 |
300 (12 in) |
77 |
K-factor |
78 |
K-factor - Calibration factor |
79 |
Body expan. coeff |
80 |
e-5/K |
81 |
Body expan. coeff. - Coefficient is used in conjunction with the average process temperature to correct thermal expansion effects of the meter body |
82 |
.3f |
83 |
5.3f |
84 |
Ave. process temp |
85 |
Ave. process temp - Defines the average process temperature |
86 |
K |
87 |
.0f |
88 |
3.0f |
89 |
Ampl. Gain |
90 |
Ampl. Gain - Amplifier gain |
91 |
very low |
92 |
low |
93 |
normal |
94 |
high |
95 |
Var. Number |
96 |
Flow Sensor- Hardware that measures flow rate. |
97 |
Flow Sensor - Hardware that measures flow rate. |
98 |
Note to the operator that this information must be sent before further editing. |
99 |
Edit Notice |
100 |
Code entry |
101 |
Safety code entry field for write protect for HART. Entering correct code disables write protection, entering -1 enables write protection. |
102 |
Reset Totalizer |
103 |
Reset Totalizer - Resets the totalizer and the overflow counter for totalizer. |
104 |
Offline |
105 |
Matrix group sel. |
106 |
System Units |
107 |
Analog Output |
108 |
Display |
109 |
System Parameters |
110 |
Sensor Data |
111 |
Device Data |
112 |
Review |
113 |
write variables |
114 |
FMU860 |
115 |
DT |
116 |
DVC |
117 |
FCX |
118 |
AS800 |
119 |
340T |
120 |
340C |
121 |
344 |
122 |
Siemens Micro K |
123 |
SITRANS L |
124 |
SIPAN PH |
125 |
SITRANS P |
126 |
75SMT |
127 |
UNIDELTA |
128 |
8320 |
129 |
SX5100 |
130 |
TSV175 |
131 |
DMU |
132 |
3780 |
133 |
BM70 |
134 |
8u |
135 |
Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. |
136 |
6.2f |
137 |
4.2f |
138 |
7d |
139 |
HART Output |
140 |
Status |
141 |
Revision #'s |
142 |
NOTICE - This information must be sent to the transmitter to update dependent parameters. |
143 |
About to perform Totalizer Reset! |
144 |
Totalizer reset performed |