0 |
PROMAG-39 |
1 |
Positive zero return active |
2 |
Current output simulation |
3 |
Frequency output simulation |
4 |
Low voltage detected |
5 |
Sensor DAT failure |
6 |
Sensor EEPROM failure |
7 |
Sensor ROM/RAM failure |
8 |
Sensor gain failure |
9 |
Low voltage detected |
10 |
Low reference detected |
11 |
Value not accepted |
12 |
EPD calibration not ok |
13 |
EPD calibration values out of limit |
14 |
EPD calibration values equal |
15 |
EPD calibration values reversed |
16 |
Flow too high |
17 |
Current output overflow |
18 |
Frequency output overflow |
19 |
Batch time exceeded |
20 |
EPD adjust running |
21 |
Batch running |
22 |
.5g |
23 |
Flow Unit |
24 |
Flow Unit - Engineering unit to be displayed with all flow values. |
25 |
hl/min |
26 |
hl/h |
27 |
cc/min |
28 |
Vol Unit |
29 |
Volume Unit - Engineering unit to be displayed with all volumes. |
30 |
* 1000 gal |
31 |
Low Flow Cutoff - Set point that determines when the process variable will indicate 0 rather than some nominally small value. |
32 |
Pulse Scaling Factor - Magnitude of volume per pulse. |
33 |
6u |
34 |
.2f |
35 |
5.2f |
36 |
Status: normal |
37 |
Status: errors |
38 |
FO1 |
39 |
FO1 - actual value of output frequency. |
40 |
Tot |
41 |
Tot > |
42 |
Tot - Totalized Flow (Totalizer), '>' means overflow of totalizer has occurred. |
43 |
.7g |
44 |
*1000 gal |
45 |
Size Unit |
46 |
Size Unit - Unit of the nominal diameter parameter. |
47 |
gal/bbl |
48 |
Gallons/barrel - Defines the gallons (US or Imperial) and the amount of gallons per barrel. |
49 |
US: 31.0 |
50 |
US: 31.5 |
51 |
US: 42.0 |
52 |
US: 55.0 |
53 |
IMP: 36.0 |
54 |
IMP: 42.0 |
55 |
Range 1 |
56 |
Range 1 Value - Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. |
57 |
Range 2 |
58 |
Range 2 Value - Defines the operational endpoint for the second range in the dual range mode. |
59 |
Dual Range |
60 |
Dual Range - This controls the dual range mode which affects the analog output. |
61 |
Active Range |
62 |
Range Status - Indicates the active range if in dual range mode. |
63 |
Rng 1 |
64 |
Rng 2 |
65 |
Current Span |
66 |
Current Span - always 4-20 mA with HART, max. output current can be either 25 mA or 20.5 mA. |
67 |
4-20 mA (25 mA) |
68 |
4-20 mA |
69 |
Alarm Type |
70 |
Analog Output Alarm Type - Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE - The Digital Value representation may not be determinate. |
71 |
Low |
72 |
High |
73 |
Analog Sim |
74 |
Analog Simulation - Simulates the specified analog output current. |
75 |
2 mA |
76 |
4 mA |
77 |
12 mA |
78 |
20 mA |
79 |
22 mA |
80 |
25 mA |
81 |
Freq/Pulse |
82 |
Frequency/Pulse - Controls the operation mode of the frequency and pulse output. Freq: Flow / frequency. Pulse: Volume / pulse. |
83 |
Freq |
84 |
Pulse |
85 |
Pulse width - Maximum width of each pulse of the pulse output. |
86 |
s |
87 |
4.2f |
88 |
Max Freq |
89 |
Maximum Frequency - Full scale frequency for the upper range limit flow. |
90 |
5u |
91 |
URV |
92 |
Upper Range Value - Flow value at maximum frequency. |
93 |
Output |
94 |
Output - The frequency/pulse output can generate positive or negative pulses in active (push-pull) or passive (open-collector) mode. |
95 |
passiv/pos |
96 |
passiv/neg |
97 |
activ/pos |
98 |
activ/neg |
99 |
FO Alarm Type |
100 |
Frequency output alarm type - Status of frequency/pulse output in error condition. |
101 |
Freq Sim |
102 |
Frequency Simulation - Simulation of the specified frequency for test. |
103 |
0 Hz |
104 |
2 Hz |
105 |
10 Hz |
106 |
1 kHz |
107 |
10 kHz |
108 |
Rel1 fct |
109 |
Relay 1 Function - Which signal affects relay 1. |
110 |
Failure |
111 |
EPD |
112 |
Failure+EPD |
113 |
Range |
114 |
Batch precontact |
115 |
Flow-Dir |
116 |
Limit 1 |
117 |
Switch on R1 |
118 |
Switch on R1 - Switch on point for relay 1. |
119 |
Switch off R1 |
120 |
Switch off R1 - Switch off point for relay 1. |
121 |
Rel2 fct |
122 |
Relay 2 Function - Which signal affects relay 2. |
123 |
Batch contact |
124 |
Limit 2 |
125 |
Switch on R2 |
126 |
Switch on R2 - Switch on point for relay 2. |
127 |
Switch off R2 |
128 |
Switch off R2 - Switch off point for relay 2. |
129 |
Batch Variable |
130 |
Batch Variable - Activates the batching functions. |
131 |
Volume |
132 |
Batch Preset |
133 |
Batch Preset - Preset quantity of one batch. |
134 |
Batch Prewarn |
135 |
Batch Prewarn - Coarse quantity used for two-stage batching cycles. |
136 |
Compens.Quantity |
137 |
Compensation Quantity - used to compensate an over-/underfilling. |
138 |
+.5g |
139 |
Batching |
140 |
Batching - Starting or stopping of a batch cycle. |
141 |
Cancel |
142 |
Start |
143 |
Stop |
144 |
Max. Batch Time |
145 |
Max. Batch Time - max. allowed filling interval. This safety control function is disabled when the batch time value is set to zero. |
146 |
Batch Cycle |
147 |
Batch Cycle - number of batching cycles completed. |
148 |
7.0f |
149 |
Tot ovfl |
150 |
Totalizer overflow - Number of overflows of the totalizer. |
151 |
5d |
152 |
Display Damping |
153 |
Display Damping - time constant of the displayed flow value. |
154 |
2u |
155 |
Display Format |
156 |
Display Format - number of significant digits of the flow value showed on the field device's local display. |
157 |
x.xxxx |
158 |
x.xxx |
159 |
x.xx |
160 |
LCD Contrast |
161 |
LCD Contrast - Contrast of local Display (0 - 100%). |
162 |
% |
163 |
3u |
164 |
Language |
165 |
Language - Language of local control. |
166 |
Dutch |
167 |
Danish |
168 |
Norwegian |
169 |
Swedish |
170 |
Finnish |
171 |
Bahasa Indonesia |
172 |
Japanese |
173 |
Aux.Input |
174 |
Aux.Input - Function assigned to the auxiliary input. |
175 |
Reset Totalizer |
176 |
PZR |
177 |
Start Pulse Width |
178 |
Start Pulse Width - Min. time of the pulse applied to the auxiliary input to activate the selected function. |
179 |
ms |
180 |
Positive Zero Return - all flow values are suppressed. |
181 |
Customer Code |
182 |
Customer Code - Safety code for local control and write protect for HART. Entering correct code disables write protection. |
183 |
4u |
184 |
Code Entry |
185 |
Code Entry - Safety code for local control and write protect for HART. Entering correct code disables write protection, entering -1 enables write protection. |
186 |
4d |
187 |
Self check |
188 |
Self checking - Controls self check function of the measuring amplifier. |
189 |
SW AMP |
190 |
Software Amplifier - Software version of amplifier module. |
191 |
SW COM |
192 |
Software Communication - Software version of communication module. |
193 |
Noise sup |
194 |
Noise sup - Noise suppression is a software filter to reduce the sensitivity against transient flows and interference peaks. |
195 |
Low |
196 |
Medium |
197 |
High |
198 |
EPD - Empty pipe detection control and calibration. |
199 |
Adj empty pipe |
200 |
Adj full pipe |
201 |
EPD Delay |
202 |
EPD Delay - Delay off empty pipe detection. |
203 |
1 s |
204 |
2 s |
205 |
5 s |
206 |
10 s |
207 |
30 s |
208 |
60 s |
209 |
Meas Mode |
210 |
Meas Mode - Bidirectional or unidirectional flow measurement. |
211 |
unidirect |
212 |
bidirect |
213 |
Flow dir |
214 |
Flow dir - Flow direction is forward or reverse. |
215 |
forward |
216 |
reverse |
217 |
Ampl. Mode |
218 |
Ampl. Mode - Amplifier in normal mode (auto-gain) or in fixed gain mode 1 to 4. |
219 |
Normal |
220 |
Mode 1 |
221 |
Mode 2 |
222 |
Mode 3 |
223 |
Mode 4 |
224 |
Ampl. Delay |
225 |
Ampl. Delay - Amplifier in normal mode (auto-gain) waits a certain number of measuring samples before increasing its gain. |
226 |
Calf pos |
227 |
Calf pos - Sensor calibration factor in forward flow direction. |
228 |
.4f |
229 |
6.4f |
230 |
Calf neg |
231 |
Calf neg - Sensor calibration factor in reverse flow direction. |
232 |
Zero point |
233 |
Pipe zero - Deviation of the sensor tube's zero point. |
234 |
Line size |
235 |
Line size - Nominal diameter of the sensor tube. |
236 |
.0f |
237 |
4.0f |
238 |
7.4f |
239 |
max SAPS |
240 |
max SAPS - Maximum sampling rate of sensor. |
241 |
/ s |
242 |
.1f |
243 |
4.1f |
244 |
act SAPS |
245 |
actual SAPS - Actual sampling rate of sensor. |
246 |
EPD electrode |
247 |
EPD electrode - Empty pipe electrode in flow tube available. |
248 |
|
249 |
sec |
250 |
mA |
251 |
Hz |
252 |
Flow Sensor - Hardware that measures flow rate. |
253 |
Pulse output - scaled frequency output from 0-10000 Hz, linear with input. |
254 |
Flow Sensor - Hardware that measures flow rate. |
255 |
Pulse Output - Scaled frequency output from 0-10000 Hz, linear with input. |
256 |
Pulse output units - Engineering units displayed with the frequency and totalizer output values |
257 |
Pulse output value - scaled frequency output from 0-10000 Hz, linear with input |
258 |
Reset Totalizer - Reset the totalizer and the totalizer overflow counter. |
259 |
Reset Batch Cycles |
260 |
Reset Batch Cycles - Reset the batch cycle counter. |
261 |
Master reset |
262 |
Commands the electronics to reset and perform a selftest. Reports any errors occured. |
263 |
Edit Notice |
264 |
Notify the operator that this information must be sent before further editing. |
265 |
Offline |
266 |
Group Select |
267 |
System Units |
268 |
Current Output |
269 |
Puls/Freq. Output |
270 |
Relays |
271 |
Display |
272 |
Processing Para. |
273 |
System Parameter |
274 |
Sensor Data |
275 |
Device Data |
276 |
Review |
277 |
write variables |
278 |
FMU860 |
279 |
DT |
280 |
DVC |
281 |
FCX |
282 |
AS800 |
283 |
340T |
284 |
340C |
285 |
344 |
286 |
Siemens Micro K |
287 |
SITRANS L |
288 |
SIPAN PH |
289 |
SITRANS P |
290 |
75SMT |
291 |
UNIDELTA |
292 |
8320 |
293 |
SX5100 |
294 |
TSV175 |
295 |
DMU |
296 |
3780 |
297 |
BM70 |
298 |
8u |
299 |
Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. |
300 |
Low Flow Cutoff- Set point that determines when the process variable will indicate 0 rather than some nominally small value. |
301 |
6.2f |
302 |
7d |
303 |
Pulse Scaling Factor- Magnitude of process variable per pulse. |
304 |
7.5f |
305 |
.5f |
306 |
HART Output |
307 |
Status |
308 |
Revision #'s |
309 |
About to perform Totalizer Reset! |
310 |
Performing Totalizer reset now |
311 |
Totalizer reset performed |
312 |
About to perform batch cycle counter reset! |
313 |
Performing batch cycle counter reset now |
314 |
Batch cycle counter reset performed |
315 |
About to Exit Simulation Mode |
316 |
About to Enter Simulation Mode or Changing Value |
317 |
Simulation mode finished |
318 |
Simulation mode entered or Value changed |
319 |
About to reset the slave device NOTE-Loop should be removed from automatic control |
320 |
Reset in progress, please wait |
321 |
Device maybe stuck in selftest. |
322 |
Master Reset OK |
323 |
NOTICE - This information must be sent to the transmitter to update dependent parameters. |