0 |
AT70 |
1 |
Endress+Hauser |
2 |
Low voltage detected |
3 |
Sensor DAT-failure |
4 |
Sensor EEPROM-failure |
5 |
Sensor PIC micro failure |
6 |
All inputs out of range |
7 |
Flow signal too high |
8 |
Flow signal too low |
9 |
Gas temp signal out of limits |
10 |
Room temp out of range |
11 |
Flow beyond calibration |
12 |
Pulse rate out of range |
13 |
Current output out of range |
14 |
AO1 |
15 |
This is the current output value |
16 |
mA |
17 |
Percent of Range |
18 |
Display of the percentage of full scale output |
19 |
% |
20 |
Linearisation |
21 |
Type of linearisation of the measured value |
22 |
Polynomial |
23 |
Special |
24 |
Flow unit |
25 |
SCuMtr_hr |
26 |
SCuMtr_min |
27 |
SCuMtr_s |
28 |
SL_hr |
29 |
SL_min |
30 |
SL_s |
31 |
LTon_min |
32 |
Ton_s |
33 |
Low Flow Cutoff- Set point that determines when the process variable will indicate 0 rather than some nominally small value. |
34 |
.2f |
35 |
4.2f |
36 |
PV URV |
37 |
6.2f |
38 |
PV USL |
39 |
Flow damping |
40 |
S |
41 |
.1f |
42 |
4.1f |
43 |
Flow |
44 |
Flow Min Span |
45 |
6.1f |
46 |
Alarm Selection |
47 |
Analog Output during Alarm condition |
48 |
Sensor serial |
49 |
6d |
50 |
O.Coll.func |
51 |
Function of the open collector output option |
52 |
OFF |
53 |
Pulse |
54 |
Pulse Scaling Factor- Magnitude of process variable per pulse. |
55 |
.3f |
56 |
7.3f |
57 |
mS |
58 |
Pulse Width- Width of the pulse output |
59 |
3d |
60 |
Tot. units |
61 |
Engineering units of the totaliser & pulse output |
62 |
SCuMtr |
63 |
SL |
64 |
Pulse simulation |
65 |
Allows the user to simulate a pulse output |
66 |
OFF |
67 |
0% |
68 |
50% |
69 |
100% |
70 |
Totaliser |
71 |
Totaliser - Totalised Flow |
72 |
Temp unit |
73 |
Temperature Unit- Engineering units that the temperature will be displayed with. |
74 |
Gas Temp |
75 |
Field Device Process Temperature. |
76 |
Peak Temp |
77 |
Peak Temperature measured - maximum temperature the user has reached |
78 |
Ambient temp |
79 |
Temperature of the electronics pcb |
80 |
Password |
81 |
Local control password entry |
82 |
4d |
83 |
Inst. factor |
84 |
Installation factor - scaling factor applied to the basic flow reading to allow for installation depth, etc. |
85 |
6.3f |
86 |
Proc. factor |
87 |
Process factor - use selected factor to allow for such things as damp gases |
88 |
Pipe Type |
89 |
Shows the type of duct the sensors are in |
90 |
Cell |
91 |
Circular |
92 |
Rectangular |
93 |
Pipe width |
94 |
Cell or Pipe width (diameter) if insertion probe |
95 |
5.1f |
96 |
Duct depth |
97 |
Cell or Pipe depth in a rectangular duct |
98 |
N. Density |
99 |
Gas Normal Density - actual value of gas density at 0øC and 1.013 bar conditions |
100 |
S. Density |
101 |
Gas Standard Density - actual value of gas density at 15øC and 1.013 bar conditions |
102 |
Cal. gas |
103 |
Type of gas the calibration was performed on |
104 |
User Gas |
105 |
Type of gas selected by the user |
106 |
TP 1 |
107 |
Test Point 1 - mV signal of the Vflow signal |
108 |
TP 2 |
109 |
Test Point 2 - mV signal of the Vtemp signal |
110 |
Totaliser Control |
111 |
Allows the user to change the totaliser mode |
112 |
ESC |
113 |
OFF |
114 |
ON |
115 |
RST |
116 |
Flow LRV |
117 |
Minimum flowrate is always 0 |
118 |
Error bits value |
119 |
Combined error bit flags |
120 |
Error Code |
121 |
Error Code for the highest priority error |
122 |
Assy Nr |
123 |
Assembly number of complete AT70 |
124 |
Linear range |
125 |
Range of linear curve fit near to zero flow |
126 |
Zero value |
127 |
Compensated input for zero flow at process conditions |
128 |
Software code |
129 |
Unique software code |
130 |
Flow MinmV |
131 |
Reading for zero flow at calibration |
132 |
Flow MaxmV |
133 |
Reading for max flow at calibration |
134 |
Zero Adjust |
135 |
Allows the user to set a local process zero |
136 |
Esc |
137 |
Off |
138 |
Set |
139 |
Ratio Offset |
140 |
Gas Ratio Offset |
141 |
Ratio Scale |
142 |
/øC |
143 |
Gas Ratio Gain |
144 |
Flow Sensor- Hardware that measures flow rate. |
145 |
Gas Temperature - approximate. |
146 |
rtemperature |
147 |
Room Temperature - approximate. |
148 |
Temperature - Hardware that measures the temperature within the Field Device. |
149 |
RTemperature - Hardware that measures the temperature within the Field Device. |
150 |
Var. Number |
151 |
unit_0 |
152 |
|
153 |
unit_1 |
154 |
ma |
155 |
unit_2 |
156 |
unit_3 |
157 |
sec |
158 |
unit_4 |
159 |
mm |
160 |
unit_5 |
161 |
kg_m3 |
162 |
unit_6 |
163 |
unit_7 |
164 |
mV |
165 |
Index |
166 |
Update Table |
167 |
HotKey |
168 |
Offline |
169 |
Matrix group sel. |
170 |
System Units |
171 |
Analog Output |
172 |
Open Collector |
173 |
System Parameter |
174 |
Errors/Warnings |
175 |
Sensor Data |
176 |
Device Data |
177 |
Diagnostics |
178 |
Conversion |
179 |
write variables |
180 |
FMU860 |
181 |
DT |
182 |
DVC |
183 |
FCX |
184 |
AS800 |
185 |
340T |
186 |
340C |
187 |
344 |
188 |
Siemens Micro K |
189 |
SITRANS L |
190 |
SIPAN PH |
191 |
SITRANS P |
192 |
75SMT |
193 |
UNIDELTA |
194 |
8320 |
195 |
SX5100 |
196 |
TSV175 |
197 |
DMU |
198 |
3780 |
199 |
BM70 |
200 |
8u |
201 |
HART Output |
202 |
About to change the Totaliser mode! |
203 |
Totaliser Control: |
204 |
Stop;Run;Reset |
205 |
Totaliser Stopped |
206 |
Totaliser Running |
207 |
Totaliser Reset |