0 |
TGAES RX A |
1 |
ESP Safety |
2 |
Device fault |
3 |
Limit 1 active |
4 |
Limit 2 active |
5 |
Device calibrated |
6 |
Sensor zeroed |
7 |
Limit 1 changed |
8 |
Limit 2 changed |
9 |
Gas changed |
10 |
Power failed |
11 |
Lens temperature err |
12 |
Device temperature err |
13 |
Not aligned |
14 |
Check PD |
15 |
Low signal |
16 |
Flash miss |
17 |
Cold start |
18 |
Alrm. typ |
19 |
Channel flags] |
20 |
STX Count |
21 |
ACK Count |
22 |
BACK Count |
23 |
Zero trim |
24 |
Trim reset |
25 |
Concentration |
26 |
% LEL*m Concentration value measured by device variable 0 |
27 |
.2f |
28 |
Concentration unit |
29 |
%LEL*m |
30 |
percent lower explosion level times meter |
31 |
|
32 |
Conc Class |
33 |
Conc PDQ |
34 |
Conc LS |
35 |
Conc Fmly stat |
36 |
Conc USL |
37 |
.1f |
38 |
Conc LSL |
39 |
Conc min span |
40 |
Conc damp |
41 |
8.1f |
42 |
Conc Update Period |
43 |
Conc snsr s/n |
44 |
7d |
45 |
Conc Lower trim |
46 |
.3f |
47 |
Conc Upper trim |
48 |
Conc Trim support |
49 |
Conc Min lower trim |
50 |
Conc Max lower trim |
51 |
Conc Min upper trim |
52 |
Conc Max upper trim |
53 |
Conc Min trim diff |
54 |
Concentration unit |
55 |
Simulate |
56 |
PV-Concentration |
57 |
LEL*m |
58 |
Conc |
59 |
PV is the gas volume concentration in %LEL*m, devvar[0] |
60 |
Sensor Unit |
61 |
PDQ |
62 |
LS |
63 |
Family status |
64 |
Class |
65 |
Device family |
66 |
USL |
67 |
LSL |
68 |
Min span |
69 |
Damp |
70 |
Update Period |
71 |
Snsr s/n |
72 |
Trim unit |
73 |
Lower trim |
74 |
Upper trim |
75 |
Trim support |
76 |
Min lower trim |
77 |
Max lower trim |
78 |
Min upper trim |
79 |
Max upper trim |
80 |
Min trim diff |
81 |
State flags |
82 |
Relay Dev Fault |
83 |
State of device fault relay |
84 |
Relay Thres 1 |
85 |
State of relay 1 (limit 1) |
86 |
Relay Thres 2 |
87 |
State of relay 2 (limit 2) |
88 |
AGC |
89 |
State of AGC |
90 |
Settings |
91 |
Relay Dev Fault Enabled |
92 |
If relay is disabled and not used, it is off in any dev state |
93 |
Relay Dev Fault Locked |
94 |
If locked, the relay remembers any single fault and stays off till unlocked |
95 |
Relay Lev1 Enabled |
96 |
Relay Lev1 Locked |
97 |
Relay Lev2 Enabled |
98 |
Relay Lev2 Locked |
99 |
TGA-RX device root menu |
100 |
TGA-RX diagnostics root menu |
101 |
maintenance_root_menu |
102 |
offline_root_menu |
103 |
TGA-RX process variables root menu |
104 |
TGA-RX root menu |
105 |
Diagnostic root menu |
106 |
Device information |
107 |
Process variables |
108 |
All dev vars |
109 |
Status |
110 |
Output info |
111 |
Analog output |
112 |
HART output |
113 |
Review |
114 |
Revision #'s |
115 |
Sensor trim points |
116 |
Device setup |
117 |
Calibration |
118 |
Tags |
119 |
Other info |
120 |
Sensor setup |
121 |
Output condtion |
122 |
Signal condition |
123 |
Conc sensor |
124 |
Sensor info |
125 |
Align device |
126 |
Conc vol% |
127 |
Signal quality ref |
128 |
Signal quality work |
129 |
Channel ref |
130 |
Channel work |
131 |
Flash misses per min |
132 |
Flash misses |
133 |
Align 1 |
134 |
Align 2 |
135 |
Align 3 |
136 |
Align 4 |
137 |
Lens temperature |
138 |
Device temperature |
139 |
Voltage Supply |
140 |
Lens heat On |
141 |
Device heat On |
142 |
Val range |
143 |
8.2f |
144 |
LEL 2 vol |
145 |
Conc magnet |
146 |
Relay level 1 |
147 |
Relay level 2 |
148 |
Work time |
149 |
Control state |
150 |
LED inversion |
151 |
Stop flag |
152 |
Archive flag |
153 |
Valid adjustment flag |
154 |
Valid METHANE calibration flag |
155 |
Valid zero set flag |
156 |
Relay threshold 1 on |
157 |
Relay threshold 2 on |
158 |
Valid ETHYLENE calibration flag |
159 |
Europe (off), US (on) |
160 |
Show negative concentration (on) |
161 |
Temperature calib table loaded |
162 |
Concentration below zero by more than 10% of the measurement limit, cleared at a concentration >= 0 |
163 |
Valid PROPANE calibration flag |
164 |
Control current block |
165 |
Gas type |
166 |
METHANE |
167 |
PROPANE |
168 |
ETHYLENE |
169 |
BUTANE |
170 |
ISOBUTANE |
171 |
PENTAN |
172 |
CYCLOPENTAN |
173 |
ETHANOL |
174 |
METHYL |
175 |
Device state variables |
176 |
PV Analog Channel Saturated |
177 |
PV Analog Channel Fixed |
178 |
Wireless |
179 |
WirelessHART Device |
180 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
181 |
Primary |
182 |
Primary Analog Channel |
183 |
Secondary |
184 |
Secondary Analog Channel |
185 |
Tertiary |
186 |
Tertiary Analog Channel |
187 |
Quaternary |
188 |
Quaternary Analog Channel |
189 |
Quinary |
190 |
Quinary Analog Channel |
191 |
Critical Power Failure |
192 |
Lock all |
193 |
Trim not supported |
194 |
Configuration cannot be changed |
195 |
Locked by gateway |
196 |
Analog Input Channel |
197 |
Analog Output Channel |
198 |
Secondary Analog Channel Saturated |
199 |
Tertiary Analog Channel Saturated |
200 |
Quaternary Analog Channel Saturated |
201 |
Quinary Analog Channel Saturated |
202 |
Secondary Analog Channel Fixed |
203 |
Tertiary Analog Channel Fixed |
204 |
Quaternary Analog Channel Fixed |
205 |
Quinary Analog Channel Fixed |
206 |
Simulation active |
207 |
The device is in simulation mode and the level output is not representative of the process. |
208 |
Non-Volatile memory failure |
209 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
210 |
Volatile memory error |
211 |
The RAM memory check is invalid or maybe corrupt |
212 |
Watchdog reset executed |
213 |
A watchdog reset has been performed |
214 |
Voltage conditions out of range |
215 |
A voltage condition is outside its allowable range |
216 |
Environmental conditions out of range |
217 |
An internal or environmental condition is beyond acceptable limits. |
218 |
Electronic failure |
219 |
A hardware problem not related to the sensor has been detected. |
220 |
Subdevice list changed |
221 |
Duplicate master detected |
222 |
Capacity Denied |
223 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
224 |
Bandwidth allocation pending |
225 |
Block transfer pending |
226 |
Battery life |
227 |
Percent range |
228 |
Loop current |
229 |
Primary variable |
230 |
Secondary variable |
231 |
Tertiary variable |
232 |
Quaternary variable |
233 |
Read receive time |
234 |
Write date and time |
235 |
Non-Volatile Clock |
236 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
237 |
Clock Uninitialized |
238 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
239 |
None |
240 |
No restrictions |
241 |
SI Only |
242 |
Restricted to SI Unit codes only |
243 |
Process automation device |
244 |
Discrete device |
245 |
Hybrid:Process automation+discrete |
246 |
I/O System |
247 |
WirelessHART Process automation device |
248 |
WirelessHART Discrete device |
249 |
WirelessHART Process automation+discrete |
250 |
WirelessHART Gateway |
251 |
WirelessHART Access point |
252 |
WirelessHART Process adapter |
253 |
WirelessHART Discrete adapter |
254 |
WirelessHART enabled handheld/portable maintenance tool |
255 |
Device Profile |
256 |
US |
257 |
United States of America |
258 |
JP |
259 |
Japan |
260 |
DE |
261 |
Germany |
262 |
FR |
263 |
France |
264 |
ES |
265 |
Spain |
266 |
RU |
267 |
Russian Federation |
268 |
CN |
269 |
People's Republic of China |
270 |
Secondary Master |
271 |
Primary Master |
272 |
Device Diagnostic Status 0 |
273 |
Device Diagnostic Status 1 |
274 |
I/O and Subdevice Status |
275 |
WirelessHART Status |
276 |
Time Set Option |
277 |
Real Time Clock Flags |
278 |
Country |
279 |
Country of intended device installation |
280 |
SI Unit Control |
281 |
Indicates if device should only display SI unit codes |
282 |
Time Stamp |
283 |
Relative time value on network |
284 |
8u |
285 |
Dynamic Variables Returned for Device Variables |
286 |
Command Response Truncated |
287 |
Configuration Change Counter Mismatch |
288 |
Status bytes mismatch |
289 |
8.3f |
290 |
Device Variable |
291 |
Variable to trim |
292 |
ACK Count |
293 |
Count of ACK messages received by this device |
294 |
BACK Count |
295 |
Count of BACK messages received by this device |
296 |
STX Count |
297 |
Count of STX messages received by this device |
298 |
Align procedure
WORK %[5.0f]{dataValSignalQualityWorkVal} % REF %[5.0f]{dataValSignalQualityRefVal} %
FLAGS 0x%[08x]{devStateSettingsVal}
Press OK when stable. |