0 |
SGOES |
1 |
ESP Safety |
2 |
.1f |
3 |
8.2f |
4 |
8.1f |
5 |
Vol. Concentration |
6 |
Volume Concentration value measured by device variable 0 |
7 |
.2f |
8 |
Concentration unit |
9 |
|
10 |
Conc Class |
11 |
Conc PDQ |
12 |
Conc LS |
13 |
Conc Fmly stat |
14 |
Conc USL |
15 |
Conc LSL |
16 |
Conc min span |
17 |
Conc damp |
18 |
Conc Update Period |
19 |
Conc snsr s/n |
20 |
7d |
21 |
Simulate |
22 |
Conc Lower trim |
23 |
Conc Upper trim |
24 |
Conc Trim support |
25 |
Conc Min lower trim |
26 |
Conc Max lower trim |
27 |
Conc Min upper trim |
28 |
Conc Max upper trim |
29 |
Conc Min trim diff |
30 |
Concentration |
31 |
Second Device Variable (deviceVariables[1]) is concentration. xmtr-mv supports an imaginary set of expanded engineering units in this device variable slot |
32 |
Update Period |
33 |
% LEL Concentration value measured by device variable 1 |
34 |
Snsr temp unit |
35 |
Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. |
36 |
Temperature Class |
37 |
Temperature PDQ |
38 |
Temperature LS |
39 |
Temperature Fmly stat |
40 |
Temp USL |
41 |
Temp LSL |
42 |
Temp min span |
43 |
Temperature Update Period |
44 |
Temp snsr s/n |
45 |
Secondary Variable - Temperature Compensation |
46 |
% LEL concentration threshold from device variable 3 |
47 |
Fourth Device Variable (deviceVariables[3]) is concentration threshold 1. |
48 |
Concentration value measured by device variable 4 |
49 |
Fifth Device Variable (deviceVariables[4]) is concentration threshold 2. |
50 |
Gas Type |
51 |
Gas calibrated for |
52 |
None |
53 |
No gas type assigned |
54 |
Methane |
55 |
Propane |
56 |
Hexane |
57 |
Butane |
58 |
IsoButane |
59 |
Pentane |
60 |
CycloPentane |
61 |
Ethane |
62 |
CO2 |
63 |
Methyl |
64 |
Low Alarm Value |
65 |
High Alarm Value |
66 |
Alarm Select |
67 |
Calib Type |
68 |
Selects one or two span gas concentrations |
69 |
One Cal Gas |
70 |
Select One Calibration Gas |
71 |
Two Cal Gas |
72 |
Select Two Calibration Gases |
73 |
Sensor trim points |
74 |
Gas Sensor |
75 |
Temperature sensor |
76 |
Alarm Levels |
77 |
Sensor trim |
78 |
Sensor trim reset |
79 |
Clear calibration mode |
80 |
PV Analog Channel Saturated |
81 |
PV Analog Channel Fixed |
82 |
Wireless |
83 |
WirelessHART Device |
84 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
85 |
Primary |
86 |
Primary Analog Channel |
87 |
Secondary |
88 |
Secondary Analog Channel |
89 |
Tertiary |
90 |
Tertiary Analog Channel |
91 |
Quaternary |
92 |
Quaternary Analog Channel |
93 |
Quinary |
94 |
Quinary Analog Channel |
95 |
Critical Power Failure |
96 |
Lock all |
97 |
Trim not supported |
98 |
Configuration cannot be changed |
99 |
Locked by gateway |
100 |
Analog Input Channel |
101 |
Analog Output Channel |
102 |
Secondary Analog Channel Saturated |
103 |
Tertiary Analog Channel Saturated |
104 |
Quaternary Analog Channel Saturated |
105 |
Quinary Analog Channel Saturated |
106 |
Secondary Analog Channel Fixed |
107 |
Tertiary Analog Channel Fixed |
108 |
Quaternary Analog Channel Fixed |
109 |
Quinary Analog Channel Fixed |
110 |
Simulation active |
111 |
The device is in simulation mode and the level output is not representative of the process. |
112 |
Non-Volatile memory failure |
113 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
114 |
Volatile memory error |
115 |
The RAM memory check is invalid or maybe corrupt |
116 |
Watchdog reset executed |
117 |
A watchdog reset has been performed |
118 |
Voltage conditions out of range |
119 |
A voltage condition is outside its allowable range |
120 |
Environmental conditions out of range |
121 |
An internal or environmental condition is beyond acceptable limits. |
122 |
Electronic failure |
123 |
A hardware problem not related to the sensor has been detected. |
124 |
Subdevice list changed |
125 |
Duplicate master detected |
126 |
Capacity Denied |
127 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
128 |
Bandwidth allocation pending |
129 |
Block transfer pending |
130 |
Battery life |
131 |
Percent range |
132 |
Loop current |
133 |
Primary variable |
134 |
Secondary variable |
135 |
Tertiary variable |
136 |
Quaternary variable |
137 |
Read receive time |
138 |
Write date and time |
139 |
Non-Volatile Clock |
140 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
141 |
Clock Uninitialized |
142 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
143 |
No restrictions |
144 |
SI Only |
145 |
Restricted to SI Unit codes only |
146 |
Process automation device |
147 |
Discrete device |
148 |
Hybrid:Process automation+discrete |
149 |
I/O System |
150 |
WirelessHART Process automation device |
151 |
WirelessHART Discrete device |
152 |
WirelessHART Process automation+discrete |
153 |
WirelessHART Gateway |
154 |
WirelessHART Access point |
155 |
WirelessHART Process adapter |
156 |
WirelessHART Discrete adapter |
157 |
WirelessHART enabled handheld/portable maintenance tool |
158 |
Device Profile |
159 |
US |
160 |
United States of America |
161 |
JP |
162 |
Japan |
163 |
DE |
164 |
Germany |
165 |
FR |
166 |
France |
167 |
ES |
168 |
Spain |
169 |
RU |
170 |
Russian Federation |
171 |
CN |
172 |
People's Republic of China |
173 |
Secondary Master |
174 |
Primary Master |
175 |
Device Diagnostic Status 0 |
176 |
Device Diagnostic Status 1 |
177 |
I/O and Subdevice Status |
178 |
WirelessHART Status |
179 |
Time Set Option |
180 |
Real Time Clock Flags |
181 |
Country |
182 |
Country of intended device installation |
183 |
SI Unit Control |
184 |
Indicates if device should only display SI unit codes |
185 |
Time Stamp |
186 |
Relative time value on network |
187 |
8u |
188 |
Dynamic Variables Returned for Device Variables |
189 |
Command Response Truncated |
190 |
Configuration Change Counter Mismatch |
191 |
Status bytes mismatch |
192 |
8.3f |
193 |
.3f |
194 |
Device Variable |
195 |
Variable to trim |
196 |
ACK Count |
197 |
Count of ACK messages received by this device |
198 |
BACK Count |
199 |
Count of BACK messages received by this device |
200 |
STX Count |
201 |
Count of STX messages received by this device |
202 |
%[s]{disp_string1}
Current Value %[5.2f]{conc0Value} %{conc0Units} |
203 |
%[s]{disp_string1} |
204 |
Select number of cal gases |
205 |
One;Two |
206 |
Apply input between %[5.1f]{trim_min} %{deviceVariables[device_variable_trim_code].TRIM_POINT_UNITS} and %[5.1f]{trim_max} %{deviceVariables[device_variable_trim_code].TRIM_POINT_UNITS}.
Press OK when stable.
Current Value: %{deviceVariables[device_variable_trim_code].DIGITAL_VALUE} |
207 |
Enter Cal Gas %{deviceVariables[device_variable_trim_code].TRIM_POINT_UNITS} |
208 |
Waiting for cal gas to clear.
Current Value: %{deviceVariables[1].DIGITAL_VALUE} %{deviceVariables[1].DIGITAL_UNITS} |