954 SmartServo FlexLine |
1 |
ENRAF |
2 |
Disabled |
3 |
Enabled |
4 |
Critical |
5 |
AO not Calibrated |
6 |
Check Analog Output
Upper Range and Lower
Range configured |
7 |
ROM Failure |
8 |
Power Cycle the device.
Still problem persists,
Replace Electronic Module |
9 |
RAM Failure |
10 |
NOVRAM Failure |
11 |
Power Cycle the device.
Still problem persists,
Contact Service Engineer |
12 |
DAC Read back Failure |
13 |
Lock/Unlock Device |
14 |
Level |
15 |
.3f |
16 |
8.3f |
17 |
7d |
18 |
Length Unit |
19 |
Product Level |
20 |
Device settings |
21 |
Diagnostics |
22 |
Maintenance |
23 |
Offline |
24 |
Operate |
25 |
Re-range |
26 |
Device Image |
27 |
This is an IMAGE |
28 |
Dynamic Variables |
29 |
PV |
30 |
PV Analog Channel Saturated |
31 |
PV Analog Channel Fixed |
32 |
Wireless |
33 |
WirelessHART Device |
34 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
35 |
Primary |
36 |
Primary Analog Channel |
37 |
Secondary |
38 |
Secondary Analog Channel |
39 |
Tertiary |
40 |
Tertiary Analog Channel |
41 |
Quaternary |
42 |
Quaternary Analog Channel |
43 |
Quinary |
44 |
Quinary Analog Channel |
45 |
Critical Power Failure |
46 |
Lock all |
47 |
Trim not supported |
48 |
Configuration cannot be changed |
49 |
Locked by gateway |
50 |
Analog Input Channel |
51 |
Analog Output Channel |
52 |
Secondary Analog Channel Saturated |
53 |
Tertiary Analog Channel Saturated |
54 |
Quaternary Analog Channel Saturated |
55 |
Quinary Analog Channel Saturated |
56 |
Secondary Analog Channel Fixed |
57 |
Tertiary Analog Channel Fixed |
58 |
Quaternary Analog Channel Fixed |
59 |
Quinary Analog Channel Fixed |
60 |
Simulation active |
61 |
The device is in simulation mode and the level output is not representative of the process. |
62 |
Non-Volatile memory failure |
63 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
64 |
Volatile memory error |
65 |
The RAM memory check is invalid or maybe corrupt |
66 |
Watchdog reset executed |
67 |
A watchdog reset has been performed |
68 |
Voltage conditions out of range |
69 |
A voltage condition is outside its allowable range |
70 |
Environmental conditions out of range |
71 |
An internal or environmental condition is beyond acceptable limits. |
72 |
Electronic failure |
73 |
A hardware problem not related to the sensor has been detected. |
74 |
Subdevice list changed |
75 |
Duplicate master detected |
76 |
Capacity Denied |
77 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
78 |
Bandwidth allocation pending |
79 |
Block transfer pending |
80 |
Battery life |
81 |
Percent range |
82 |
Loop current |
83 |
Primary variable |
84 |
Secondary variable |
85 |
Tertiary variable |
86 |
Quaternary variable |
87 |
Read receive time |
88 |
Write date and time |
89 |
Non-Volatile Clock |
90 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
91 |
Clock Uninitialized |
92 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
93 |
None |
94 |
No restrictions |
95 |
SI Only |
96 |
Restricted to SI Unit codes only |
97 |
Process automation device |
98 |
Discrete device |
99 |
Hybrid:Process automation+discrete |
100 |
I/O System |
101 |
WirelessHART Process automation device |
102 |
WirelessHART Discrete device |
103 |
WirelessHART Process automation+discrete |
104 |
WirelessHART Gateway |
105 |
WirelessHART Access point |
106 |
WirelessHART Process adapter |
107 |
WirelessHART Discrete adapter |
108 |
WirelessHART enabled handheld/portable maintenance tool |
109 |
Device Profile |
110 |
|
111 |
US |
112 |
United States of America |
113 |
JP |
114 |
Japan |
115 |
DE |
116 |
Germany |
117 |
FR |
118 |
France |
119 |
ES |
120 |
Spain |
121 |
RU |
122 |
Russian Federation |
123 |
CN |
124 |
People's Republic of China |
125 |
Secondary Master |
126 |
Primary Master |
127 |
Device Diagnostic Status 0 |
128 |
Device Diagnostic Status 1 |
129 |
I/O and Subdevice Status |
130 |
WirelessHART Status |
131 |
Time Set Option |
132 |
Real Time Clock Flags |
133 |
Country |
134 |
Country of intended device installation |
135 |
SI Unit Control |
136 |
Indicates if device should only display SI unit codes |
137 |
8u |
138 |
Dynamic Variables Returned for Device Variables |
139 |
Command Response Truncated |
140 |
Configuration Change Counter Mismatch |
141 |
Status bytes mismatch |
142 |
Device Variable |
143 |
Output Status |
144 |
Output Status Byte |
145 |
Uninitialized |
146 |
Normal - one sensor |
147 |
Normal - two sensors |
148 |
Normal - three sensors |
149 |
Shorted |
150 |
Shorted- shorted field wiring. |
151 |
Limited high |
152 |
Limited high- block can not respond to upward movement of value. |
153 |
Open |
154 |
Open- open field wiring. |
155 |
Limited low |
156 |
Limited low- block can not respond to upward movement of target. |
157 |
Initialization done |
158 |
Initialization done- block initialization is complete. |
159 |
Not selected |
160 |
Not selected- target value provided by block was not selected. |
161 |
No path |
162 |
No path- there is no path to the process. |
163 |
Fail |
164 |
Fail- hardware failure. |
165 |
Bad |
166 |
Bad- block is out of service or has bad input. |
167 |
Not from process |
168 |
Not from process- value is not directly affected by any process information. |
169 |
Local override |
170 |
Local override- block has LO mode. |
171 |
Not Cascade Mode |
172 |
Not RCas Mode |
173 |
Not ROut Mode |
174 |
No communication |
175 |
No communication- (NO_COM). |
176 |
uint16_var_blk_char |
177 |
uint32_var_blk_char |
178 |
uint8_var_blk_char |
179 |
int8_var_blk_char |
180 |
new itest redef1 label |