0 |
OXITEC 5000 |
1 |
ENOTEC GmbH |
2 |
Error status |
3 |
Errorstatus of OXITEC 5000 |
4 |
Const out of tolerance |
5 |
Slope out of tolerance |
6 |
Refgas flow too low |
7 |
Calgas flow too low |
8 |
Heating system failure |
9 |
Wirebreak thermoelement |
10 |
Errorcell o o range |
11 |
Error probe heater |
12 |
Alarm status |
13 |
Temp of Elctr. o o spec |
14 |
Probetemp too hi |
15 |
Probetemp too lo |
16 |
Alarm limit1 |
17 |
Alarm limit2 |
18 |
Datafault EEProm |
19 |
Measvalue memory active |
20 |
Error ACAL |
21 |
Calibration Busy |
22 |
Internal comunication |
23 |
Int com failure |
24 |
Calibration status |
25 |
Calibration status of OXITEC 5000 |
26 |
Calibration OK |
27 |
Calibration Fault |
28 |
Calibration Active |
29 |
Calibration Pending |
30 |
.2f |
31 |
8.2f |
32 |
pv PDQ |
33 |
PV LS |
34 |
PV Fmly stat |
35 |
AN CH |
36 |
Number of analigue channels |
37 |
One Analog Ch |
38 |
One Out Channel. |
39 |
SensorSerNo |
40 |
Three byte number |
41 |
PV Quality |
42 |
SV Quality |
43 |
TV Quality |
44 |
PV Limit Status |
45 |
SV Limit Status |
46 |
TV Limit Status |
47 |
Device Family Status |
48 |
More Device Family Status Available |
49 |
PV Var Class |
50 |
SV Var Class |
51 |
TV Var Class |
52 |
PV fmly |
53 |
SV fmly |
54 |
TV fmly |
55 |
.1f |
56 |
8.1f |
57 |
% |
58 |
Gas level |
59 |
Cell temperature |
60 |
Gas Cell temperature- Hardware that measures gas level. |
61 |
degC |
62 |
Cell Temperature |
63 |
Cell Voltage |
64 |
Gas Cell voltage - Hardware that measures gas level. |
65 |
mV |
66 |
Cell voltage |
67 |
Command code |
68 |
Code |
69 |
2d |
70 |
Unit of the parameter |
71 |
Dimention |
72 |
Programmable constant. The value may be determined by the user |
73 |
Constant |
74 |
Slope |
75 |
Alarm levels may be defined in OXITEC 5000. The levels are determined by the user |
76 |
Limit1 |
77 |
Limit2 |
78 |
Limit1 func |
79 |
Min |
80 |
Max |
81 |
Limit2 func |
82 |
Setup |
83 |
Monitor |
84 |
Calibrate |
85 |
Settings |
86 |
Alarm |
87 |
Installation data |
88 |
HART output |
89 |
Revision No |
90 |
Device status |
91 |
One point calibration |
92 |
This menu is used for single point calibration of the detector. |
93 |
Two point calibration |
94 |
This menu is used for two point calibration of the detector. |
95 |
Range values |
96 |
This menu is used for range setting and review. |
97 |
PV Analog Channel Saturated |
98 |
PV Analog Channel Fixed |
99 |
Wireless |
100 |
WirelessHART Device |
101 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
102 |
Primary |
103 |
Primary Analog Channel |
104 |
Secondary |
105 |
Secondary Analog Channel |
106 |
Tertiary |
107 |
Tertiary Analog Channel |
108 |
Quaternary |
109 |
Quaternary Analog Channel |
110 |
Quinary |
111 |
Quinary Analog Channel |
112 |
Critical Power Failure |
113 |
Lock all |
114 |
Trim not supported |
115 |
Configuration cannot be changed |
116 |
Locked by gateway |
117 |
Analog Input Channel |
118 |
Analog Output Channel |
119 |
Secondary Analog Channel Saturated |
120 |
Tertiary Analog Channel Saturated |
121 |
Quaternary Analog Channel Saturated |
122 |
Quinary Analog Channel Saturated |
123 |
Secondary Analog Channel Fixed |
124 |
Tertiary Analog Channel Fixed |
125 |
Quaternary Analog Channel Fixed |
126 |
Quinary Analog Channel Fixed |
127 |
Simulation active |
128 |
The device is in simulation mode and the level output is not representative of the process. |
129 |
Non-Volatile memory failure |
130 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
131 |
Volatile memory error |
132 |
The RAM memory check is invalid or maybe corrupt |
133 |
Watchdog reset executed |
134 |
A watchdog reset has been performed |
135 |
Voltage conditions out of range |
136 |
A voltage condition is outside its allowable range |
137 |
Environmental conditions out of range |
138 |
An internal or environmental condition is beyond acceptable limits. |
139 |
Electronic failure |
140 |
A hardware problem not related to the sensor has been detected. |
141 |
Subdevice list changed |
142 |
Duplicate master detected |
143 |
Capacity Denied |
144 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
145 |
Bandwidth allocation pending |
146 |
Block transfer pending |
147 |
Battery life |
148 |
Percent range |
149 |
Loop current |
150 |
Primary variable |
151 |
Secondary variable |
152 |
Tertiary variable |
153 |
Quaternary variable |
154 |
Read receive time |
155 |
Write date and time |
156 |
Non-Volatile Clock |
157 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
158 |
Clock Uninitialized |
159 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
160 |
None |
161 |
No restrictions |
162 |
SI Only |
163 |
Restricted to SI Unit codes only |
164 |
Process automation device |
165 |
Discrete device |
166 |
Hybrid:Process automation+discrete |
167 |
I/O System |
168 |
WirelessHART Process automation device |
169 |
WirelessHART Discrete device |
170 |
WirelessHART Process automation+discrete |
171 |
WirelessHART Gateway |
172 |
WirelessHART Access point |
173 |
WirelessHART Process adapter |
174 |
WirelessHART Discrete adapter |
175 |
WirelessHART enabled handheld/portable maintenance tool |
176 |
Device Profile |
177 |
|
178 |
US |
179 |
United States of America |
180 |
JP |
181 |
Japan |
182 |
DE |
183 |
Germany |
184 |
FR |
185 |
France |
186 |
ES |
187 |
Spain |
188 |
RU |
189 |
Russian Federation |
190 |
CN |
191 |
People's Republic of China |
192 |
Secondary Master |
193 |
Primary Master |
194 |
Device Diagnostic Status 0 |
195 |
Device Diagnostic Status 1 |
196 |
I/O and Subdevice Status |
197 |
WirelessHART Status |
198 |
Time Set Option |
199 |
Real Time Clock Flags |
200 |
Country |
201 |
Country of intended device installation |
202 |
SI Unit Control |
203 |
Indicates if device should only display SI unit codes |
204 |
Time Stamp |
205 |
Relative time value on network |
206 |
8u |
207 |
Dynamic Variables Returned for Device Variables |
208 |
Command Response Truncated |
209 |
Configuration Change Counter Mismatch |
210 |
Status bytes mismatch |
211 |
8.3f |
212 |
.3f |
213 |
Device Variable |
214 |
Do you
want to
calibrate? |
215 |
Aborting method due to last error |
216 |
This will take
some time |
217 |
Calibration not started |
218 |
Process aborted |
219 |
Calibration OK |
220 |
Calibration Fault |
221 |
Calibration active |
222 |
Calibration pending
but not started |
223 |
Unspecified fault |
224 |
Wait while
Calibrate |
225 |
Calibration is
succesfully
completed |
226 |
Calibration Pending |
227 |
This will take
some time. |
228 |
Calibration fault |
229 |
Upper range: %{0} %
Lower range: %{1} % |
230 |
Do you want
to change? |
231 |
Upper range
: |
232 |
Lower range
: |