0 |
Dynisco |
1 |
IPX |
2 |
8.0f |
3 |
.1f |
4 |
.2f |
5 |
.3f |
6 |
.4f |
7 |
Sensor temp |
8 |
Lower trim point |
9 |
Lower trim value - always within 10% of zero differential pressure |
10 |
Upper trim point |
11 |
Upper trim point - a value between 90 and 110% of Upper range value |
12 |
ALARM
Alarm flag 0 |
13 |
ALARM
Alarm flag 1 |
14 |
ALARM
Alarm flag 2 |
15 |
ALARM
Alarm flag 3 |
16 |
ALARM
Alarm flag 4 |
17 |
ALARM
Alarm flag 5 |
18 |
ALARM
Alarm flag 6 |
19 |
ALARM
Alarm flag 7 |
20 |
WARNING
Warning flag 0 |
21 |
WARNING
Warning flag 1 |
22 |
WARNING
Warning flag 2 |
23 |
WARNING
Warning flag 3 |
24 |
WARNING
Warning flag 4 |
25 |
WARNING
Warning flag 5 |
26 |
WARNING
Warning flag 6 |
27 |
WARNING
Warning flag 7 |
28 |
Isolator Material - Construction material isolators |
29 |
7d |
30 |
8.3f |
31 |
3.1f |
32 |
Normal |
33 |
Override |
34 |
Temp override |
35 |
3.0f |
36 |
Damping |
37 |
TBD by Dynisco |
38 |
Fast response |
39 |
Moderate damping |
40 |
Slow response |
41 |
Keypad Rerange |
42 |
Rerange |
43 |
Device Info |
44 |
Device Params |
45 |
Sensor trim |
46 |
Upload Variables |
47 |
Full trim |
48 |
Requires trim of sensor at zero and near full scale pressure |
49 |
Instructs transmitter to perform internal self test. |
50 |
Temp. Override |
51 |
TBD by DYNISCO |
52 |
FMU860 |
53 |
DT |
54 |
DVC |
55 |
FCX |
56 |
AS800 |
57 |
340T |
58 |
340C |
59 |
344 |
60 |
Siemens Micro K |
61 |
SITRANS L |
62 |
SIPAN PH |
63 |
SITRANS P |
64 |
75SMT |
65 |
UNIDELTA |
66 |
8320 |
67 |
SX5100 |
68 |
TSV175 |
69 |
DMU |
70 |
3780 |
71 |
BM70 |
72 |
8u |
73 |
Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. |
74 |
Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. |
75 |
.3g |
76 |
.f |
77 |
Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. |
78 |
% |
79 |
3.2f |
80 |
Sensor Limit Units and Minimum Span Units- Engineering unit to be displayed with the Upper Sensor Limit, Lower Sensor Limit, and Minimum Span. Pressure- Pressure of the process measured with respect to a reference pressure. |
81 |
Upper Sensor Limit Value- Defines the maximum useable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. |
82 |
Lower Sensor Limit Value- Defines the minimum useable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. |
83 |
Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. |
84 |
Pres xfer fnctn |
85 |
Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. Pressure- Pressure of the process measured with respect to a reference pressure. |
86 |
Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. |
87 |
Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. |
88 |
Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. |
89 |
Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. |
90 |
s |
91 |
4.2f |
92 |
Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. |
93 |
O Ring Material- Construction material of a seal that exists between the module and flange. |
94 |
Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. |
95 |
Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. |
96 |
Sensor Fill Fluid- Fluid material in the module. |
97 |
Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed. |
98 |
Send warning |
99 |
Send Warning- Yields a units code notice to the User. |
100 |
Variables which use this as the units code will be in the previous units until this value is sent to the device. |
101 |
low |
102 |
high |
103 |
tmp_av |
104 |
Apply process pressure close to zero within +/- %{sens_limit} %{0} |
105 |
Input lower trim value. |
106 |
Apply process pressure between %{low_sens_limit} and %{up_sens_limit} %{0} |
107 |
Input upper trim value. |
108 |
Retry Upper Sensor Trim? |
109 |
Yes;No |
110 |
Sensor upper trim succeeded |
111 |
Selftest complete |
112 |
No Device Problems seen during Selftest |
113 |
Status complete |
114 |
No Device Problems seen during status check. |
115 |
Last Override temp =
%{0} deg C
Do you wish to override? |
116 |
No;Yes |
117 |
Input new temp. value in deg C |
118 |
In override mode
Temp = %{0} deg C
Select choice |
119 |
Stay in override;Normal mode |