0 |
PIR 7x00 |
1 |
Draeger |
2 |
System Error1 |
3 |
CRC Boot System |
4 |
Beyond Remedy ! -> Service / Substitute Device |
5 |
CRC Firmware |
6 |
RAM |
7 |
Remedy: Try Reset Device |
8 |
Last Gas Configuration |
9 |
Remedy: Try Reset Device ...
... and check Configuration |
10 |
E2P Version |
11 |
Lambda |
12 |
Remedy: Reinstall / Update Gas Database |
13 |
GDB Format |
14 |
Delayed |
15 |
System Error2 |
16 |
F1 Version |
17 |
F2 Version |
18 |
TGI2 |
19 |
TGI2 Version |
20 |
Filter Sum |
21 |
0x04 |
22 |
Scan Sum |
23 |
CRC SILlock |
24 |
System Error3 |
25 |
CRC F1 |
26 |
CRC F2 |
27 |
CRC E2PH |
28 |
CRC CG0 |
29 |
Remedy: Configure Gas and/or Fundamental Init. |
30 |
CRC CG1 |
31 |
0x04 |
32 |
0x02 |
33 |
CRC TGI2H |
34 |
System Error4 |
35 |
CRC |
36 |
Remedy: Fundamental Init. ...
... and Configuration etc |
37 |
System Error5 |
38 |
Heater |
39 |
Volt. uC |
40 |
RAM2 |
41 |
Power Volt. |
42 |
Remedy: Check HW Installation |
43 |
Temperatur |
44 |
4-20mA |
45 |
0x02 |
46 |
0x01 |
47 |
System Error6 |
48 |
RCMM |
49 |
0x40 |
50 |
0x20 |
51 |
0x10 |
52 |
0x08 |
53 |
Measurement Error1 |
54 |
Beam Block |
55 |
IR Sensor |
56 |
Meas.Lamp |
57 |
Ref.Lamp |
58 |
Meas.Detect. |
59 |
Ref.Detect. |
60 |
Measurement Error2 |
61 |
Span |
62 |
Remedy: Span Calibration |
63 |
Zero |
64 |
Remedy: Zero Calibration |
65 |
Meas.Val.too low |
66 |
Remedy: Zero Calibration ...
... and may be Span Calibration |
67 |
Measurement Error3 |
68 |
0x80 |
69 |
Measurement Error4 |
70 |
Lamp1 |
71 |
Extreme Dirt ...
... or Extrem Low Lamp Light
Remedy: Clean Beam Path or Substitute Device |
72 |
Clipping Signal Reference Siganal |
73 |
Clipping Signal Measurement Signal |
74 |
Lamp2 |
75 |
Signal inner Lamp too low
Remedy: Substitute Device |
76 |
Meas2 low |
77 |
Ref1 low |
78 |
Ref2 low |
79 |
Measurement Error5 |
80 |
Remote Operation / Operator |
81 |
HART |
82 |
ICom |
83 |
Mag.Key |
84 |
HART prim. Master (1) active |
85 |
Status System |
86 |
RCMM Maint. |
87 |
Busy (Warm up) |
88 |
Preparing Meas. Values |
89 |
Warning1 |
90 |
Measurement Warning |
91 |
Intern.Temp. > 75'C |
92 |
Warm up 1 |
93 |
Warm up 2 |
94 |
Beam Block |
95 |
Warning2 |
96 |
pvGasValue |
97 |
.3f |
98 |
pvGasUnit |
99 |
ppm |
100 |
Gass Dev fmly |
101 |
Gas Classification |
102 |
Gas Process Data Quality |
103 |
Gas limit status |
104 |
Gas Fmly stat |
105 |
USL |
106 |
LSL |
107 |
8.3f |
108 |
7d |
109 |
PVcoll |
110 |
Temperature |
111 |
.1f |
112 |
Temp. limit status |
113 |
Temp Dev Stat |
114 |
|
115 |
SV Var Class |
116 |
Temperatur Dev fmly |
117 |
Conc. |
118 |
Temp. |
119 |
Offline |
120 |
Diagnostic |
121 |
Process Variables |
122 |
Maintenance |
123 |
/Revision #'s |
124 |
Device Settings |
125 |
/Warmup/Timer |
126 |
Remote Operation |
127 |
None |
128 |
Mag.Cal.Zero Entry |
129 |
Mag.Cal.Span Entry |
130 |
Persister |
131 |
Just./Test Analog |
132 |
getGasInfo |
133 |
Sink/Source Conf. |
134 |
Conf.Gas |
135 |
Conf.Cal.Gas |
136 |
E2P remote |
137 |
Fundamental Init. |
138 |
Conf.GasDetect.Response |
139 |
Mag.Cal.Zero |
140 |
Mag.Cal.Span |
141 |
Calibration |
142 |
PIR 7x00 |
143 |
/Online Info |
144 |
/Meas. Values |
145 |
Temperature> |
146 |
/Device Conf. |
147 |
/Meas. Conf. |
148 |
/Calib. Conf. |
149 |
/Analog. Conf. |
150 |
/Comm. Conf. |
151 |
/Check&SIL lock |
152 |
Refresh List> |
153 |
Meas.Gas |
154 |
MGas1 |
155 |
Cal.Gas |
156 |
CalGas1 |
157 |
Meas.Gas org. Name |
158 |
Cal.Gas org. Name |
159 |
Device is SILlocked |
160 |
LEL Meas.Gas |
161 |
.0f |
162 |
Gas2LEL1 |
163 |
LEL Meas.Gas |
164 |
LEL Meas.Gas org. Value |
165 |
LEL Cal.Gas |
166 |
Cal2LEL1 |
167 |
LEL Cal.Gas org. Value |
168 |
LEL Meas.Gas Max |
169 |
LEL Meas.Gas Min |
170 |
LEL Cal.Gas Max |
171 |
LEL Cal.Gas Min |
172 |
Cal.Conc. |
173 |
-CU- |
174 |
Cal.Conc. Max |
175 |
Cal.Gas Conc. |
176 |
SetPoint |
177 |
-MU- |
178 |
SetPoint Min |
179 |
SetPstd |
180 |
SetPoint Max |
181 |
Index |
182 |
Meas.Unit(-MU-) |
183 |
Cal.Gas Unit(-CU-) |
184 |
Capture Lower Value |
185 |
Capture Value |
186 |
Capture Upper Value |
187 |
Capture Lower Value |
188 |
Capture Upper Value |
189 |
Capture Upper Limit |
190 |
Capture Lower Limit |
191 |
LEL Category |
192 |
NIOSH |
193 |
IEC |
194 |
PTB |
195 |
LEL Category |
196 |
Set LEL Category> |
197 |
Response |
198 |
Normal |
199 |
Fast |
200 |
Lvl2zero |
201 |
Lvl1zero |
202 |
% |
203 |
Lvl1span |
204 |
zero1 |
205 |
Lvl2span |
206 |
Fault |
207 |
mA |
208 |
Maintenance |
209 |
Beam Block Warning |
210 |
Alternate Maintenance |
211 |
obsolet! |
212 |
Alternate Warning |
213 |
Analog Mode |
214 |
Auto |
215 |
Source |
216 |
Sink |
217 |
-hex- |
218 |
Polling Address |
219 |
Temperature Warning |
220 |
Conc. |
221 |
Meas.Gas |
222 |
Meas.Unit |
223 |
HW Part Number |
224 |
HW Serial Number |
225 |
SW Part Number |
226 |
SW Version |
227 |
SW Revision |
228 |
SW Sub Revision |
229 |
Warm-up Phase |
230 |
min |
231 |
d |
232 |
Run-in Phase |
233 |
Zero Timeout in |
234 |
h |
235 |
Zero timeout in |
236 |
GDB No. |
237 |
FVers Meas.Gas |
238 |
Lambda Meas.Gas |
239 |
iVers Meas.Gas |
240 |
Meas.GasCode |
241 |
Cal.GasCode |
242 |
F-Vers Cal.Gas |
243 |
Lambda Cal.Gas |
244 |
iVers Cal.Gas |
245 |
Set Gas> |
246 |
Set Cal.Gas> |
247 |
Set Unit> |
248 |
Set Unit> |
249 |
SIL PIN |
250 |
.... |
251 |
SIL Lock |
252 |
none |
253 |
Configuration only |
254 |
Conf. & Maint. |
255 |
SIL ID |
256 |
Set SIL PIN Admin> |
257 |
Set SIL PIN Maint.> |
258 |
SILlock |
259 |
Conf+Calib |
260 |
Set SIL Lock> |
261 |
Set Test Signal> |
262 |
Trim Analog Output> |
263 |
Span |
264 |
Test |
265 |
CrossVal. |
266 |
Gas is ON |
267 |
Impossible |
268 |
Done |
269 |
OK |
270 |
CAL_VAL |
271 |
.2f |
272 |
Calibrate> |
273 |
Spec.Comm. |
274 |
None |
275 |
Regard Compl. |
276 |
Reset> |
277 |
Fundamental Init> |
278 |
Meas.Gas CAS No. |
279 |
Cal.Gas CAS No. |
280 |
BB Return to Meas. |
281 |
BB Return to Meas. Max |
282 |
PV Analog Channel Saturated |
283 |
PV Analog Channel Fixed |
284 |
Wireless |
285 |
WirelessHART Device |
286 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
287 |
Primary |
288 |
Primary Analog Channel |
289 |
Secondary |
290 |
Secondary Analog Channel |
291 |
Tertiary |
292 |
Tertiary Analog Channel |
293 |
Quaternary |
294 |
Quaternary Analog Channel |
295 |
Quinary |
296 |
Quinary Analog Channel |
297 |
Critical Power Failure |
298 |
Lock all |
299 |
Trim not supported |
300 |
Configuration cannot be changed |
301 |
Locked by gateway |
302 |
Analog Input Channel |
303 |
Analog Output Channel |
304 |
Secondary Analog Channel Saturated |
305 |
Tertiary Analog Channel Saturated |
306 |
Quaternary Analog Channel Saturated |
307 |
Quinary Analog Channel Saturated |
308 |
Secondary Analog Channel Fixed |
309 |
Tertiary Analog Channel Fixed |
310 |
Quaternary Analog Channel Fixed |
311 |
Quinary Analog Channel Fixed |
312 |
Simulation active |
313 |
The device is in simulation mode and the level output is not representative of the process. |
314 |
Non-Volatile memory failure |
315 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
316 |
Volatile memory error |
317 |
The RAM memory check is invalid or maybe corrupt |
318 |
Watchdog reset executed |
319 |
A watchdog reset has been performed |
320 |
Voltage conditions out of range |
321 |
A voltage condition is outside its allowable range |
322 |
Environmental conditions out of range |
323 |
An internal or environmental condition is beyond acceptable limits. |
324 |
Electronic failure |
325 |
A hardware problem not related to the sensor has been detected. |
326 |
Subdevice list changed |
327 |
Duplicate master detected |
328 |
Capacity Denied |
329 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
330 |
Bandwidth allocation pending |
331 |
Block transfer pending |
332 |
Battery life |
333 |
Percent range |
334 |
Loop current |
335 |
Primary variable |
336 |
Secondary variable |
337 |
Tertiary variable |
338 |
Quaternary variable |
339 |
Read receive time |
340 |
Write date and time |
341 |
Non-Volatile Clock |
342 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
343 |
Clock Uninitialized |
344 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
345 |
No restrictions |
346 |
SI Only |
347 |
Restricted to SI Unit codes only |
348 |
Process automation device |
349 |
Discrete device |
350 |
Hybrid:Process automation+discrete |
351 |
I/O System |
352 |
WirelessHART Process automation device |
353 |
WirelessHART Discrete device |
354 |
WirelessHART Process automation+discrete |
355 |
WirelessHART Gateway |
356 |
WirelessHART Access point |
357 |
WirelessHART Process adapter |
358 |
WirelessHART Discrete adapter |
359 |
WirelessHART enabled handheld/portable maintenance tool |
360 |
Device Profile |
361 |
US |
362 |
United States of America |
363 |
JP |
364 |
Japan |
365 |
DE |
366 |
Germany |
367 |
FR |
368 |
France |
369 |
ES |
370 |
Spain |
371 |
RU |
372 |
Russian Federation |
373 |
CN |
374 |
People's Republic of China |
375 |
Secondary Master |
376 |
Primary Master |
377 |
Device Diagnostic Status 0 |
378 |
Device Diagnostic Status 1 |
379 |
I/O and Subdevice Status |
380 |
WirelessHART Status |
381 |
Time Set Option |
382 |
Real Time Clock Flags |
383 |
Country |
384 |
Country of intended device installation |
385 |
SI Unit Control |
386 |
Indicates if device should only display SI unit codes |
387 |
Time Stamp |
388 |
Relative time value on network |
389 |
8u |
390 |
Dynamic Variables Returned for Device Variables |
391 |
Command Response Truncated |
392 |
Configuration Change Counter Mismatch |
393 |
Status bytes mismatch |
394 |
Temperatur: %0 degC. |
395 |
LEL Category: %{0} |
396 |
Select Category;PREV Category;NEXT Category |
397 |
SIL locked ! |
398 |
MeasGas= %{0} [CAS:%{1}]
Version= %{2}
|
399 |
Select Gas;PREV Gas;NEXT Gas |
400 |
CalGas= %{0} [CAS:%{1}]
Version= %{2}
|
401 |
Meas.Unit=%{0} |
402 |
Select Unit;PREV Unit;NEXT Unit |
403 |
Cal.Unit=%{0} |
404 |
Admin.PIN:
|
405 |
PINinput3 |
406 |
new Admin.PIN:
|
407 |
PINinput2 |
408 |
Input PIN is not OK
|
409 |
new Maint.PIN:
|
410 |
SILlock: |
411 |
SIL PIN: |
412 |
pin |
413 |
SILlockID:
%{0} |
414 |
Can't restore SILlock
Check Device !
Check SILlock !
|
415 |
Enable Alarms ? |
416 |
Current Loop about to be manipulated. Disable Alarms |
417 |
Can't read SILLock Information |
418 |
SILlockID: %{0}
SIL PIN: |
419 |
PINinput |
420 |
Use Special Signal |
421 |
Fault;Warning;Maintenance;Beam Block Warning;Fix Current;Exit |
422 |
FixCurrent: |
423 |
Output Set to Fault Signal |
424 |
Output Set to Warning Signal |
425 |
Output Set to Maintenance Signal |
426 |
Output Set to Beam Block Signal |
427 |
Fld dev output is fixed at %{0} mA |
428 |
Is Value out of Alarm Range?
%{2} %{0} %{1} |
429 |
Select Calibration: |
430 |
Zero;Span |
431 |
Entering Zero mode |
432 |
Entering Span mode |
433 |
Calibration already active -.- go ahead to exit and then enter again |
434 |
Calibration already active -.- go ahead toexit and then enter again |
435 |
Cal. impossible: Please calibrate zero
Abort! |
436 |
Cal. impossible
Abort! |
437 |
Apply Zero Gas |
438 |
Apply Test Gas: %0 %1 %2 |
439 |
Value Stabilized?
%{0} %{1} %{2} |
440 |
Zero gas
last Actual: %{1} %{2}
|
441 |
OK;Try again |
442 |
Test gas %{0} %{2}
last Actual: %{1} %{2}
|
443 |
No valid calibration!
|
444 |
Press OK to Reset (Reboot) |
445 |
Press OK to Init ('Format') the Config. Areas |
446 |
Reconnect Handheld Terminal ! |