UD10 |
1 |
DET-TRONICS |
2 |
Operating Mode |
3 |
Display Status 1 |
4 |
Cal Line Active |
5 |
Cal Sw Active |
6 |
HART Test |
7 |
LON Attached |
8 |
Response Test |
9 |
Manual Self Test |
10 |
Input HART |
11 |
Reserved |
12 |
Display Status 2 |
13 |
Any Fault |
14 |
Cal Active |
15 |
Warm Up Mode |
16 |
Low Relay Active |
17 |
Hi Relay Active |
18 |
Aux Relay Active |
19 |
Current Fixed |
20 |
MB Write Protect |
21 |
Device Status 1 |
22 |
Calibration Active |
23 |
Warm Up |
24 |
Low Alarm |
25 |
Aux Alarm |
26 |
High Alarm |
27 |
Self Test |
28 |
Configuration Change |
29 |
Alignment Mode |
30 |
Device Status 2 |
31 |
Write Protect |
32 |
4-20 Fixed |
33 |
Sensor Removed |
34 |
Sensor End Of Life |
35 |
Loop Test Active |
36 |
TDSA Alarm |
37 |
Quick Alarm |
38 |
Generic Status |
39 |
Display Fault 1 |
40 |
12v Fault |
41 |
5v Fault |
42 |
3v Fault |
43 |
Output Loop Fault |
44 |
Input Loop Fault |
45 |
Display Fault 2 |
46 |
FRAM Fault |
47 |
ADC Ref Voltage Fault |
48 |
24v Fault |
49 |
Flash Fault |
50 |
RAM Fault |
51 |
WDT Fault |
52 |
Device Fault 1 |
53 |
Loop Fault |
54 |
Supply Voltage Fault |
55 |
Calibration Fault |
56 |
Memory Fault |
57 |
ADC Fault |
58 |
Internal Voltage Fault |
59 |
Zero Drift |
60 |
Temperature Sensor Fault |
61 |
Device Fault 2 |
62 |
Wrong Sensor Type |
63 |
Lamp Fault |
64 |
Alignment Fault |
65 |
Blocked Optic Fault |
66 |
Sensor Fault |
67 |
Noise Fault |
68 |
Align ADC Fault |
69 |
Device Fault 3 |
70 |
Align Fault |
71 |
Align Warning |
72 |
DAC Fault |
73 |
High Fault |
74 |
Low Fault |
75 |
Device Warm Up |
76 |
Ref Channel Fault |
77 |
Act Channel Fault |
78 |
Device Fault 4 |
79 |
Incompatible Version |
80 |
Detection Disable Fault |
81 |
Oi Fault |
82 |
Diminished Detect Fault |
83 |
Communication Fault |
84 |
General Fault |
85 |
Gas Value |
86 |
.2f |
87 |
% |
88 |
Percentage Composition |
89 |
PPM |
90 |
PPM units |
91 |
VOL% |
92 |
VOL units |
93 |
%LFL |
94 |
LFL units |
95 |
PPB |
96 |
PPB Units |
97 |
C |
98 |
Degrees C |
99 |
mA |
100 |
milliamperes |
101 |
LFL*M |
102 |
LEL Meters |
103 |
PPM*M |
104 |
PPM Meters |
105 |
VOL*M |
106 |
VOL Meters |
107 |
|
108 |
Not used enumeration |
109 |
No enumeration |
110 |
Unknow enumeration |
111 |
.3f |
112 |
Analog Output |
113 |
8.2f |
114 |
Upper Range Value |
115 |
10.2f |
116 |
Lower Range Value |
117 |
8.3f |
118 |
Serial Number |
119 |
7d |
120 |
Request Index |
121 |
Event Log Request |
122 |
FIRST |
123 |
PREV |
124 |
NEXT |
125 |
LAST |
126 |
Response Index |
127 |
TimeStamp |
128 |
Cal Code |
129 |
Empty Log |
130 |
1 |
131 |
2 |
132 |
Zero_Cal |
133 |
Span_Cal |
134 |
Abort_Cal |
135 |
Failed_Cal |
136 |
7 |
137 |
8 |
138 |
9 |
139 |
10 |
140 |
Clr Cal Flt |
141 |
Event Code |
142 |
No Event |
143 |
Power Up |
144 |
Low Alarm On |
145 |
High Alarm On |
146 |
Aux Alarm On |
147 |
EE Flt On |
148 |
ADC Ref Flt On |
149 |
24v Flt On |
150 |
Flash Flt On |
151 |
RAM Flt On |
152 |
WDT Flt On |
153 |
12V Flt On |
154 |
5V Flt On |
155 |
3 V Flt On |
156 |
Out Loop Flt On |
157 |
In Loop Flt On |
158 |
High Flt On |
159 |
Low Flt On |
160 |
Zero Drift Flt On |
161 |
Cal Flt On |
162 |
Optics Flt On |
163 |
Low Voltage On |
164 |
Cal Active Strt On |
165 |
Active ADC Flt On |
166 |
Active ADC Sat Flt On |
167 |
Tx Warmup |
168 |
CGS Loop Flt On |
169 |
CGS Comm Flt |
170 |
High 24v Flt |
171 |
Bank 1 Repaired |
172 |
Bank 2 Repaired |
173 |
Input Loop Cal Failed |
174 |
Mode Changed |
175 |
Input Loop Cal Passed |
176 |
Fire Alm On |
177 |
UV Pre Alm On |
178 |
IR Pre Alm On |
179 |
UV Alm On |
180 |
IR Alm On |
181 |
Misc Alm On |
182 |
Rep Alm On |
183 |
Pwr Flt On |
184 |
Gen Flt On |
185 |
Oi Flt On |
186 |
Oi Pre Flt On |
187 |
High IR1 Flt On |
188 |
High IR2 Flt On |
189 |
Short Ckt Flt On |
190 |
Low Alarm Off |
191 |
High Alarm Off |
192 |
Aux Alarm Off |
193 |
EE Flt Off |
194 |
ADC Ref Flt Off |
195 |
24v Flt Off |
196 |
Flash CRC Flt Off |
197 |
RAM Flt Off |
198 |
Ext WDT Flt Off |
199 |
12v Flt Off |
200 |
5v Flt Off |
201 |
3v Flt Off |
202 |
Outp Loop Flt Off |
203 |
Inp Loop Flt Off |
204 |
High Flt Off |
205 |
Low Flt Off |
206 |
Zero Drift Flt Off |
207 |
Cal Flt Off |
208 |
Optics Flt Off |
209 |
Low Volt Flt Off |
210 |
Cal Active Strt Flt Off |
211 |
Active ADC Flt Off |
212 |
Active ADC Sat Flt Off |
213 |
Sensor OK |
214 |
TX Warmup Off |
215 |
CGS Loop Flt Off |
216 |
Fire Alm Off |
217 |
UV Pre Alm Off |
218 |
IR Pre Alm Off |
219 |
UV Alm Off |
220 |
IR Alm Off |
221 |
Misc Alm Off |
222 |
Pre Alm Off |
223 |
Power Flt Off |
224 |
Gen Flt Off |
225 |
Oi Flt Off |
226 |
Oi Pre Flt Off |
227 |
High IR1 Flt Off |
228 |
High IR2 Flt Off |
229 |
Short Ckt Flt Off |
230 |
Zero Value |
231 |
10.8f |
232 |
Span Value |
233 |
Low Alarm Level |
234 |
Gas level for initiating a low alarm. The low alarm level can not be set lower than 5%LEL*M or higher than the high alarm level. |
235 |
High Alarm Level |
236 |
Gas level for initiating a high alarm. The high alarm level can not be set higher than 60%LEL*M or lower than the low alarm level. |
237 |
Auxilary Alarm Level |
238 |
Gas level for initiating an auxilary alarm. |
239 |
Aux Alarm Latch |
240 |
Selects latching or nonlatching aux alarm. Latched alarms are unlatched with Reset. |
241 |
High Alarm Latch |
242 |
Selects latching or nonlatching high alarm. Latched alarms are unlatched with Reset. |
243 |
Low Alarm Latch |
244 |
Selects latching or nonlatching low alarm. Latched alarms are unlatched with Reset. |
245 |
Password |
246 |
The password is used to validate the command to enable or disable writes in the device. |
247 |
Set Write protect |
248 |
Used to set the write protect mode. |
249 |
Change Password |
250 |
Local Zero Value |
251 |
Local zero value. |
252 |
Max Temp -Time |
253 |
Min Temp -Time |
254 |
Self test will perform all internal checks immediately and return results in variables xmtr flt 1 & xmtr flt 2. |
255 |
This command will reset latched relay outputs |
256 |
Firmware Revision |
257 |
|
258 |
Hardware Revision |
259 |
Response test |
260 |
This test holds the analog output at 4mA and prevents the alarm relays from activating when gas is applied. Gas response is indicated by the PV. |
261 |
Abort response test |
262 |
Return to normal |
263 |
Reset Latched Alarms |
264 |
This command will reset the latched alarms |
265 |
Calibration log |
266 |
Retrieves stored calibration events. The most recent calibration event is shown first. Calibrations are recorded as zero only cal, cal OK & cal failed. Cal OK indicates that both zero and span were completed. |
267 |
Event log |
268 |
Retrieves stored events. The most recent event is shown first. Recorded events include Blocked Optics, warm up, zero drift, low alarm & high alarm. |
269 |
Change Mode |
270 |
DD Build Version |
271 |
Internal DD build version number. |
272 |
Sensor Calibration |
273 |
Detector gas calibration method. Follow prompts to apply and remove calibration gas. |
274 |
Abort Calibration Method. |
275 |
Abort Method. |
276 |
Display History |
277 |
History |
278 |
Display Fault/Status Info |
279 |
Display Info |
280 |
Device Status Menu |
281 |
Device History Info |
282 |
Device Setup |
283 |
Device HART Option |
284 |
Device Info |
285 |
Device Fault/Status |
286 |
Device Info 2 |
287 |
Sensor Info |
288 |
Alarm Setting |
289 |
Display HART Option |
290 |
Main Menu |
291 |
Process Variables |
292 |
Display Status Menu |
293 |
Display Setup |
294 |
Display Test Menu |
295 |
Display General Info |
296 |
Display RTC |
297 |
Write variables |
298 |
Device Cal |
299 |
Extended Fault/Status |
300 |
Seconds |
301 |
RTC seconds value 1-59. |
302 |
Minutes |
303 |
RTC minutes value 1-59. |
304 |
Hours |
305 |
RTC hours value 1-23. |
306 |
Week |
307 |
Month |
308 |
RTC month value 1-12. |
309 |
Invalid |
310 |
Jan |
311 |
Feb |
312 |
Mar |
313 |
Apr |
314 |
May |
315 |
Jun |
316 |
Jul |
317 |
Aug |
318 |
Sep |
319 |
Oct |
320 |
Nov |
321 |
Dec |
322 |
Day |
323 |
RTC day value 1-7. |
324 |
Year |
325 |
RTC year value 1-12. |
326 |
Tx Running Hours |
327 |
Sensitivity |
328 |
Sensor Type |
329 |
Sensor Part Number |
330 |
Sensor Hardware Revision |
331 |
Firmware Rev |
332 |
Normal |
333 |
Calibration in progress |
334 |
Warm up |
335 |
Calibration State |
336 |
Waiting for Zero |
337 |
Apply Clean Air |
338 |
Waiting for Gas |
339 |
Waiting for Span |
340 |
Remove Cal Gas |
341 |
Terminate |
342 |
Complete |
343 |
Hardware Rev |
344 |
Revision |
345 |
Universal Rev |
346 |
Fld Dev Rev |
347 |
Software Rev |
348 |
Max Temp |
349 |
3.2f |
350 |
Running Hrs |
351 |
Min Temp |
352 |
Gas Name |
353 |
Cal Gas Concentration |
354 |
Response Factor |
355 |
Manufacturer |
356 |
Dev ID |
357 |
Model |
358 |
GT3000 |
359 |
X3301 |
360 |
OPECL_TX |
361 |
OPECL_RX |
362 |
ECLIPSE |
363 |
PIR |
364 |
Master Adrs Select |
365 |
Primary |
366 |
Secondary |
367 |
Cal Point Zero |
368 |
Cal Point Span |
369 |
F |
370 |
T |
371 |
High Alarm NE/NDE |
372 |
Alarm setting, normally enabled or normally disabled |
373 |
NDE |
374 |
NE |
375 |
Low Alarm NE/NDE |
376 |
Aux Alarm NE/NDE |
377 |
Extended Byte 0 |
378 |
Extended Byte 1 |
379 |
Extended Byte 2 |
380 |
Extended Byte 3 |
381 |
Pre-Alarm |
382 |
Fire Alarm |
383 |
UV Pre-Alarm |
384 |
IR Pre-Alarm |
385 |
UV Alarm |
386 |
IR Alarm |
387 |
Misc Alarm |
388 |
Extended Byte 4 |
389 |
Extended Byte 5 |
390 |
Extended Byte 6 |
391 |
Extended Byte 7 |
392 |
X Fault |
393 |
Oi Pre-Fault |
394 |
High IR1 Fault |
395 |
High IR2 Fault |
396 |
Short Circuit Fault |
397 |
Power Fault |
398 |
SV Value |
399 |
SV Units |
400 |
Upper Limit |
401 |
Lower Limit |
402 |
Minimum Span |
403 |
Damping |
404 |
TV Value |
405 |
TV Units |
406 |
QV Value |
407 |
QV Units |
408 |
Error code not defined. |
409 |
The real-time data returned from the field device has not changedsince the last time it was read OR The data sent to the field device has been rounded or truncated dueto limitations within the field device |
410 |
This code indicates that the command was not executedNo Response Data Bytes are returned from the field device. |
411 |
The requested (e.g., loop current) mode is not valid. This code indicates that the command was not executed.No Response Data Bytes are returned from the field device. |
412 |
The requested command is not implemented |
413 |
Tx Write protect error |
414 |
FMU860 |
415 |
DT |
416 |
DVC |
417 |
FCX |
418 |
AS800 |
419 |
340T |
420 |
340C |
421 |
344 |
422 |
Siemens Micro K |
423 |
SITRANS L |
424 |
SIPAN PH |
425 |
SITRANS P |
426 |
75SMT |
427 |
UNIDELTA |
428 |
8320 |
429 |
SX5100 |
430 |
TSV175 |
431 |
DMU |
432 |
3780 |
433 |
BM70 |
434 |
8u |
435 |
Date: %[02d]{day}/%[02d]{month}/%[04d]{year}
Time: %[02d]{hours}:%[02d]{mins}:%[02d]{secs} |
436 |
Self Test Completed Successfully! |
437 |
Performing Reset for Latched Alarms |
438 |
Firmware Revision: %[2d]{msb}.%[02d]{lsb} |
439 |
Hardware Revision: %[2d]{msb}.%[02d]{lsb} |
440 |
Setting fld dev output to 4mA.
Proceed? |
441 |
PV %{0} %{1}
AO %{2} mA |
442 |
Reset the Latched Alarms |
443 |
Processing Calibration Log... |
444 |
Exiting, device is busy. |
445 |
%{1}
Date: %[02d]{2}-%{3}-%[02d]{4} Time: %[02d]{5}:%[02d]{6}:%[02d]{7}
Zero: %[4.2f]{8} Span: %[4.2f]{9} |
446 |
first;previous;next;End |
447 |
Calibration Log
Calcode:%{1} Timestamp:%{2} |
448 |
%{1}
Date: %[02d]{2}-%{3}-%[02d]{4} Time: %[02d]{5}:%[02d]{6}:%[02d]{7} |
449 |
Input Password |
450 |
Input Choice |
451 |
Disable;Enable;Change Password;End |
452 |
Protection Change Success |
453 |
Protection Change Error |
454 |
Input New Password |
455 |
Password Change Success |
456 |
Password Change Error |
457 |
Changing Write Protect/Password State |
458 |
Detector Electronics Corp.
UD10
Build Version: 02.14
Build Date: 22-Oct-2010 |
459 |
Fault: Calibration mode is active. |
460 |
Fault: Warmup mode is active. |
461 |
WARNING!: Entering device calibration mode. Calibration gas is required for successful completion. |
462 |
Starting calibration sequence. |
463 |
Fault: Normal mode active. |
464 |
Fault: Warmup mode active. |
465 |
Cal mode active. |
466 |
Waiting For Zero |
467 |
Waiting For Gas |
468 |
Waiting For Span |
469 |
Calibration Complete |
470 |
WARNING: Fault detected! |
471 |
Abort Calibration in Progress. |
472 |
Please Wait... |
473 |
Calibration Aborted. |
474 |
Aborting Method |