0 |
Air in time |
1 |
|
2 |
Air out time |
3 |
device is running or self-tuning |
4 |
device is auto running or self-tuning |
5 |
Manu adjust |
6 |
Automatic operation or self tuning of equipment |
7 |
The device has not been self - tuning, and it can automatically run after self - tuning. |
8 |
Auto tune run |
9 |
Automatic operation of equipment |
10 |
The device is self tuning, please try again later. |
11 |
Factory reset |
12 |
The device is not in automatic running or self-tunning error status |
13 |
Return to uninitial |
14 |
The device is running or self-tuning |
15 |
Loop Current Not Active |
16 |
Given Single Trim |
17 |
Type actuator |
18 |
Linear actuator |
19 |
Part-turn actuator |
20 |
Angle feedback |
21 |
angle_feedback_help |
22 |
33° |
23 |
90° |
24 |
Dead band value |
25 |
dead band value help |
26 |
SET DRCT |
27 |
SET DRCT Help |
28 |
RISE |
29 |
FALL |
30 |
Direction display feedback |
31 |
Direction display feedback help |
32 |
Equipment is running or self-tuning. |
33 |
Parameters Part-turn actuator and 33° cannot be set at the same time |
34 |
Invalid actuator type |
35 |
Invalid Rated angle of rotation of feedback |
36 |
Invalid controller deadband value |
37 |
Invalid setpoint direction |
38 |
Invalid direction of manipulated variable for display and feedback |
39 |
Change device parameter |
40 |
CURTO-CU-DQD-0235 |
41 |
CURTO |
42 |
FLASH Test Error |
43 |
ROM Test Error |
44 |
RAM Test Error |
45 |
CPU Test Error |
46 |
RESERVED |
47 |
Given Signal To High |
48 |
Device Tune Error |
49 |
.1f |
50 |
8.1f |
51 |
Value |
52 |
digital_value_stemPosition_help |
53 |
Unit |
54 |
digital_units_stemPosition_help |
55 |
digital units pstemPosition help |
56 |
Class |
57 |
PDQ |
58 |
LS |
59 |
Family stat |
60 |
Upper sensor limit |
61 |
upper_sensor_limit_stemPosition_help |
62 |
Lower sensor limit |
63 |
lower_sensor_limit_stemPosition_help |
64 |
Minimum span |
65 |
minimum_span_stemPosition_help |
66 |
Damp value |
67 |
seconds_damping_value_stemPosition_help |
68 |
Sensor serial number |
69 |
7d |
70 |
stemPosition |
71 |
stemPosition_help |
72 |
sensor_givenSignal_help |
73 |
Sensor GivenSignal Units- Engineering unit to be displayed with Sensor givenSignal. |
74 |
digital units givenSignal help |
75 |
Family Status |
76 |
USL |
77 |
LSL |
78 |
Current range |
79 |
givenSignal_current_range_help |
80 |
4--20 |
81 |
givenSignal |
82 |
Secondary Variable - Given current signal percentage |
83 |
StemPos |
84 |
GivenSignal |
85 |
Device settings |
86 |
Diagnostics |
87 |
Maintenance |
88 |
Offline |
89 |
Operate |
90 |
Diag calib |
91 |
confige parameter |
92 |
Alarm status |
93 |
Device infor |
94 |
StemPos sensor |
95 |
GivenSignal sensor |
96 |
StemPos info |
97 |
GiveSignal info |
98 |
Positioner Image |
99 |
This is an IMAGE |
100 |
Dynamic Variables |
101 |
PV |
102 |
SV |
103 |
PV Analog Channel Saturated |
104 |
PV Analog Channel Fixed |
105 |
Wireless |
106 |
WirelessHART Device |
107 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
108 |
Primary |
109 |
Primary Analog Channel |
110 |
Secondary |
111 |
Secondary Analog Channel |
112 |
Tertiary |
113 |
Tertiary Analog Channel |
114 |
Quaternary |
115 |
Quaternary Analog Channel |
116 |
Quinary |
117 |
Quinary Analog Channel |
118 |
Critical Power Failure |
119 |
Lock all |
120 |
Trim not supported |
121 |
Configuration cannot be changed |
122 |
Locked by gateway |
123 |
Analog Input Channel |
124 |
Analog Output Channel |
125 |
Secondary Analog Channel Saturated |
126 |
Tertiary Analog Channel Saturated |
127 |
Quaternary Analog Channel Saturated |
128 |
Quinary Analog Channel Saturated |
129 |
Secondary Analog Channel Fixed |
130 |
Tertiary Analog Channel Fixed |
131 |
Quaternary Analog Channel Fixed |
132 |
Quinary Analog Channel Fixed |
133 |
Simulation active |
134 |
The device is in simulation mode and the level output is not representative of the process. |
135 |
Non-Volatile memory failure |
136 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
137 |
Volatile memory error |
138 |
The RAM memory check is invalid or maybe corrupt |
139 |
Watchdog reset executed |
140 |
A watchdog reset has been performed |
141 |
Voltage conditions out of range |
142 |
A voltage condition is outside its allowable range |
143 |
Environmental conditions out of range |
144 |
An internal or environmental condition is beyond acceptable limits. |
145 |
Electronic failure |
146 |
A hardware problem not related to the sensor has been detected. |
147 |
Subdevice list changed |
148 |
Duplicate master detected |
149 |
Capacity Denied |
150 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
151 |
Bandwidth allocation pending |
152 |
Block transfer pending |
153 |
Battery life |
154 |
Percent range |
155 |
Loop current |
156 |
Primary variable |
157 |
Secondary variable |
158 |
Tertiary variable |
159 |
Quaternary variable |
160 |
Read receive time |
161 |
Write date and time |
162 |
Non-Volatile Clock |
163 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
164 |
Clock Uninitialized |
165 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
166 |
None |
167 |
No restrictions |
168 |
SI Only |
169 |
Restricted to SI Unit codes only |
170 |
Process automation device |
171 |
Discrete device |
172 |
Hybrid:Process automation+discrete |
173 |
I/O System |
174 |
WirelessHART Process automation device |
175 |
WirelessHART Discrete device |
176 |
WirelessHART Process automation+discrete |
177 |
WirelessHART Gateway |
178 |
WirelessHART Access point |
179 |
WirelessHART Process adapter |
180 |
WirelessHART Discrete adapter |
181 |
WirelessHART enabled handheld/portable maintenance tool |
182 |
Device Profile |
183 |
US |
184 |
United States of America |
185 |
JP |
186 |
Japan |
187 |
DE |
188 |
Germany |
189 |
FR |
190 |
France |
191 |
ES |
192 |
Spain |
193 |
RU |
194 |
Russian Federation |
195 |
CN |
196 |
People's Republic of China |
197 |
Secondary Master |
198 |
Primary Master |
199 |
Device Diagnostic Status 0 |
200 |
Device Diagnostic Status 1 |
201 |
I/O and Subdevice Status |
202 |
WirelessHART Status |
203 |
Time Set Option |
204 |
Real Time Clock Flags |
205 |
Country |
206 |
Country of intended device installation |
207 |
SI Unit Control |
208 |
Indicates if device should only display SI unit codes |
209 |
Time Stamp |
210 |
Relative time value on network |
211 |
8u |
212 |
Dynamic Variables Returned for Device Variables |
213 |
Command Response Truncated |
214 |
Configuration Change Counter Mismatch |
215 |
Status bytes mismatch |
216 |
8.3f |
217 |
.3f |
218 |
Device Variable |
219 |
Confirm that the device is not in auto-running state or auto-tuning state |
220 |
Choose the action to perform |
221 |
AirIn;AirOut;Exit |
222 |
Input AirIn time (*10ms) |
223 |
Input AirOut time (*10ms) |
224 |
Confirm that the device is not in auto-running state or self-tuning state |
225 |
Enter self-tuning state |
226 |
The device is self-tuning |
227 |
equipment failure!!! |
228 |
At the end of self-tuning, the device enters automatic adjustment |
229 |
All parameters will be restored to factory values. Are you sure you want to restore the factory value? |
230 |
Successfully restored factory value! |
231 |
Make sure to return to uninitialized state. |
232 |
Successfully set to uninitialized state. |
233 |
Does the device exit automatic or self tuning state? |
234 |
Set the given signal to 4MA |
235 |
Set the given signal to 20MA |
236 |
Calibration of a given signal current is completed. |
237 |
Are you sure you want to modify the parameters of the device? |
238 |
select type actuator |
239 |
Linear actuator;Part-turn actuator |
240 |
select angle feedback |
241 |
33°;90° |
242 |
set the dead band value |
243 |
select setpoint direction |
244 |
RISE;FALL |
245 |
select Direction display feedback |
246 |
The parameter was successfully modified. |