0 |
Live Rate |
1 |
Display of Active unaveraged ReadIn rate.(Cps live) |
2 |
.0f |
3 |
.1f |
4 |
.2f |
5 |
.3f |
6 |
.4f |
7 |
.5f |
8 |
cps |
9 |
PV |
10 |
Digital representation of measured process value(PV->Primary Variable). |
11 |
Device Status |
12 |
Represents the Status of the Field Device in accordance to NE107
Normal
Valid output signal.
Maintenance required(M)
Still valid output signal.
Out of specification(S)
Signal out of specified range.
Function check(C)
Temporary non-valid output signal.
Failure(F)
Non-valid output signal. |
13 |
FAILURE |
14 |
OUT OF SPEC. |
15 |
FUNCTION CHECK |
16 |
MAINTENANCE REQ. |
17 |
NORMAL |
18 |
Current AO Status |
19 |
Actual Current Loop Status |
20 |
SIGNALING |
21 |
SATURATED |
22 |
FIXED |
23 |
FIXED & SATURATED |
24 |
Data Quality |
25 |
BAD |
26 |
UNCERTAIN |
27 |
MANUAL |
28 |
GOOD |
29 |
Limit Status |
30 |
Family Status |
31 |
Density Suspension |
32 |
|
33 |
Io Rate |
34 |
Measurement Status |
35 |
Display of actual measurement status. |
36 |
OK |
37 |
No help needed |
38 |
CODE 1 |
39 |
Background >= Calibration point pulse rate |
40 |
CODE 2 |
41 |
Invalid calibration point number |
42 |
CODE 3 |
43 |
Calibration is not monotonic |
44 |
CODE 4 |
45 |
Invalid coefficient value |
46 |
CODE 5 |
47 |
Invalid calibration point value |
48 |
CODE 6 |
49 |
Invalid calibration date |
50 |
CODE 7 |
51 |
Unexpected calibration failure |
52 |
CODE 8 |
53 |
Invalid range values |
54 |
Meas Rate |
55 |
Rate for adjustment of meas point. |
56 |
Operating Hours |
57 |
Operating Hours- The counter value represents the accumulated release time of operation in hours |
58 |
h |
59 |
Date |
60 |
Actual system date (mm/dd/yyyy). |
61 |
Time |
62 |
Actual system time (hh:mm:ss). |
63 |
00:00:00 |
64 |
Operating Mode |
65 |
Displays actual System Operating Mode. |
66 |
INIT |
67 |
STARTUP |
68 |
SHUTDOWN |
69 |
ERROR |
70 |
WARNING |
71 |
HOLD |
72 |
TEST |
73 |
RUN |
74 |
Instruction Code |
75 |
No instruction needed! |
76 |
1.Change
- Electronics
2.Contact BT service |
77 |
1.Restart device
2.Change
- Electronics
3.Contact BT service |
78 |
1.Restart device
2.Check
- PMT connector
- PMT detector unit
- Electronics
3.Contact BT service |
79 |
1.Restart device
2.Check
- EMC environment
3.Contact BT service |
80 |
1.Check
- Detector temperature environment
- Temperature alarm setup |
81 |
1.Check
- Process
- Process alarm setup |
82 |
1.Check
- Detector settings
- PMT connector
- PMT detector unit
- Electronics
2.Restart
3.Contact BT service |
83 |
1.Acknowledge event
2.Retry download
3.Try another file
|
84 |
1.Retry download
2.Use calibration wizard for new configuration
3.Upload new configuration
|
85 |
1.Acknowledge event
2.Restart
3.Check
- Try to set Date/Time
4. Contact BT service |
86 |
1.Wait download... it will be finished automatically.
|
87 |
1.Wait sampling... it will be finished automatically.
|
88 |
1.Wait plateau measurement... it will be finished automatically.
|
89 |
1.Wait calibration... it will be finished automatically.
|
90 |
1.Exit simulation mode
|
91 |
1.Check
- Detector calibration
- Pulse rate
- Range values
- Influence of radiation interference
2.Contact BT service
|
92 |
1.Check
- Detector calibration
2.Contact BT service
|
93 |
1.This is a notifcation to check the activated alarm setup after a new calibration has been performed
1.Check device alarm setup
2.Acknowledge event
|
94 |
1.Calibrate device by using the Quick Start Wizard |
95 |
1.Acknowledge event
2.Check actual measurement configuration
3.Run new calibration |
96 |
1.Acknowledge event
2.Run new calibration
3.Contact BT service |
97 |
1.Reboot device
2.Change electronics |
98 |
1.Check
- Configuration
2.Restart
3.Change electronics |
99 |
1.Restart device
2.Contact BT service |
100 |
1.Run factory reset
2.Run reboot |
101 |
Event Code |
102 |
Event Code which is actually signaled by the Field device. |
103 |
NO EVENT |
104 |
F100 |
105 |
F101 |
106 |
F102 |
107 |
F103 |
108 |
S104 |
109 |
F105 |
110 |
F106 |
111 |
C107 |
112 |
C108 |
113 |
C109 |
114 |
C110 |
115 |
C111 |
116 |
C112 |
117 |
C113 |
118 |
C114 |
119 |
S115 |
120 |
S116 |
121 |
S117 |
122 |
S118 |
123 |
S119 |
124 |
F120 |
125 |
F121 |
126 |
F122 |
127 |
F123 |
128 |
F200 |
129 |
F201 |
130 |
F202 |
131 |
F203 |
132 |
F204 |
133 |
F205 |
134 |
F206 |
135 |
F207 |
136 |
F300 |
137 |
S301 |
138 |
S302 |
139 |
F303 |
140 |
F304 |
141 |
F305 |
142 |
S306 |
143 |
S307 |
144 |
S308 |
145 |
S309 |
146 |
F310 |
147 |
S311 |
148 |
S312 |
149 |
S313 |
150 |
F314 |
151 |
F315 |
152 |
F316 |
153 |
F317 |
154 |
S318 |
155 |
S319 |
156 |
S320 |
157 |
F321 |
158 |
F322 |
159 |
F323 |
160 |
F400 |
161 |
F401 |
162 |
S402 |
163 |
S403 |
164 |
S404 |
165 |
S405 |
166 |
F406 |
167 |
F407 |
168 |
S408 |
169 |
S409 |
170 |
F410 |
171 |
F411 |
172 |
S412 |
173 |
S413 |
174 |
S414 |
175 |
S415 |
176 |
S416 |
177 |
S417 |
178 |
S418 |
179 |
S419 |
180 |
F420 |
181 |
F421 |
182 |
F422 |
183 |
F423 |
184 |
F500 |
185 |
F501 |
186 |
F502 |
187 |
F503 |
188 |
F504 |
189 |
F505 |
190 |
F506 |
191 |
F507 |
192 |
F600 |
193 |
S601 |
194 |
F602 |
195 |
F603 |
196 |
F604 |
197 |
F605 |
198 |
F606 |
199 |
F607 |
200 |
F700 |
201 |
F701 |
202 |
F702 |
203 |
F703 |
204 |
F704 |
205 |
F705 |
206 |
F706 |
207 |
F707 |
208 |
F800 |
209 |
F801 |
210 |
F802 |
211 |
F803 |
212 |
F804 |
213 |
F805 |
214 |
F806 |
215 |
F807 |
216 |
F900 |
217 |
F901 |
218 |
F902 |
219 |
F903 |
220 |
F904 |
221 |
F905 |
222 |
F906 |
223 |
F907 |
224 |
FALSE |
225 |
TRUE |
226 |
Detector Temp. |
227 |
Actual detector temperature value. |
228 |
Detector Temp. Mode |
229 |
Select detector temperature mode. Select 'Fix Value' for test. |
230 |
OFF |
231 |
ON |
232 |
Detector Temp. Min |
233 |
Minimum device temperature since last reset. |
234 |
Detector Temp. Max |
235 |
Maximum device temperature since last reset. |
236 |
HV Setpoint |
237 |
Display of actual HV Setpoint at multiplier. |
238 |
HV Feedback |
239 |
Display of actual HV feedback at multiplier. |
240 |
HV Average |
241 |
Display HV Average as detector raw value. HV Average has a damping value of 10 days. The value is used for error messages 'HV-Error' and 'Change Multiplier'. |
242 |
Display of detector live count rate. |
243 |
Meas Channel |
244 |
Control Channel |
245 |
Auxiliary Channel |
246 |
HV Mode |
247 |
Display actual HV mode |
248 |
AUTO |
249 |
Sensor works with HV auto mode |
250 |
PLATEAU |
251 |
Relay State |
252 |
NO ALARM |
253 |
ALARM |
254 |
Current Mode |
255 |
A fixed current value is simulated. |
256 |
Average Rate |
257 |
The ReadIn rate is newly averaged in every measurement cycle. Standardized to one second. |
258 |
Compensation Date |
259 |
Date of last compensation (mm/dd/yyyy). |
260 |
Remaining Time |
261 |
Time remaining while ReadIn. |
262 |
Background |
263 |
Enter backgound radiation count rate. |
264 |
Cal Rate |
265 |
Rate for adjustment of Cal Point. |
266 |
PB Flag |
267 |
RC Flag |
268 |
LM Flag |
269 |
PN Flag |
270 |
DISABLE |
271 |
ENABLE |
272 |
PV Unit |
273 |
Density Unit |
274 |
g/cm³ |
275 |
kg/m³ |
276 |
lb/gal |
277 |
lb/ft³ |
278 |
g/l |
279 |
Concentration Unit |
280 |
Selected solids content Unit |
281 |
wt% |
282 |
Coefficient 0 |
283 |
.3e |
284 |
.4e |
285 |
.5e |
286 |
.6e |
287 |
.7e |
288 |
.8e |
289 |
.9e |
290 |
Coefficient 1 |
291 |
Coefficient 2 |
292 |
Coefficient 3 |
293 |
cm6/g³ |
294 |
0 |
295 |
1 |
296 |
2 |
297 |
Detector Type |
298 |
Select detector type. |
299 |
CPS Format |
300 |
x |
301 |
x.x |
302 |
x.xx |
303 |
x.xxx |
304 |
x.xxxx |
305 |
x.xxxxx |
306 |
Length Format |
307 |
Temperature Format |
308 |
Voltage Format |
309 |
Dummy Variable PV |
310 |
Dummy Variable PRODUCT |
311 |
Dummy Variable ABS COEFF |
312 |
Dummy Variable COEFF |
313 |
Method Integer Type Variable |
314 |
Method Float Type Variable |
315 |
Download Active |
316 |
Is Online |
317 |
BACKGROUND |
318 |
Read-in background count rate |
319 |
ACTIVE POINT |
320 |
Read-in count rate of active point. |
321 |
IIC Address |
322 |
The IIC Address of the requested module. |
323 |
PV Format |
324 |
CPS Display Format |
325 |
CPS Edit Format |
326 |
Coeff Format |
327 |
x.xxxExxx |
328 |
x.xxxxExxx |
329 |
x.xxxxxExxx |
330 |
x.xxxxxxExxx |
331 |
x.xxxxxxxExxx |
332 |
x.xxxxxxxxExxx |
333 |
x.xxxxxxxxxExxx |
334 |
Density Classification |
335 |
Concentration Classification |
336 |
Solids Content Classification |
337 |
Length Unit |
338 |
Selected length unit used for measuring path |
339 |
Product Unit |
340 |
Selected unit used for slurry solid- and liquid density |
341 |
Temp. Unit |
342 |
Selected detector temperature unit |
343 |
°C |
344 |
°F |
345 |
cm²/g |
346 |
1/cm |
347 |
cm4/g² |
348 |
Device variable family |
349 |
PV Damping Value |
350 |
Shows the active time constant. The value 0.0 leaves the count rate unfiltered. |
351 |
PV UL |
352 |
Calculated Upper Transducer Limit Value- Upper limit in which the measurement is valid, i.e. monotonic. |
353 |
PV LL |
354 |
Calculated Lower Transducer Limit Value- Lower limit in which the measurement is valid, i.e. monotonic. |
355 |
Cal UL |
356 |
Calculated Upper Transducer Limit Value- Upper limit in which the calibration is valid, i.e. monotonic. |
357 |
Cal LL |
358 |
Calculated Lower Transducer Limit Value- Lower limit in which the calibration is valid, i.e. monotonic. |
359 |
Minimum Span |
360 |
PV Mode |
361 |
A fixed PV value is simulated. |
362 |
SIMULATE |
363 |
Pulse Rate Mode |
364 |
A fixed Rate value is simulated. |
365 |
Update Period |
366 |
Liquid Density |
367 |
Density of carrier liquid |
368 |
Solid Density |
369 |
Density of solid in the slurry |
370 |
Abs.Coefficient |
371 |
Abs.Coefficient of slurry |
372 |
R-Squared |
373 |
R-Squared of regression curve. |
374 |
PV Upper Limit |
375 |
PV Lower Limit |
376 |
Hysteresis |
377 |
Relay Assignment |
378 |
Select DO Relay assignment. |
379 |
Relay alarm state depends on Failure(F) events |
380 |
FAILURE OOS |
381 |
Relay alarm state depends on Failure(F) and OutOfSpecification(OOS) events |
382 |
PV ALARM |
383 |
Relay alarm state depends on whether PV Value goes beyond or above configured threshold limits |
384 |
TEMP ALARM |
385 |
Relay alarm state depends on whether Detector temperature goes beyond or above configured threshold limits |
386 |
ReadIn Mode |
387 |
Select Read-in mode. |
388 |
Read-in disabled |
389 |
QUICKSTART RATE |
390 |
Cal Status |
391 |
Display of actual calibration configuration status. |
392 |
3 |
393 |
4 |
394 |
5 |
395 |
6 |
396 |
7 |
397 |
8 |
398 |
No instruction needed |
399 |
Check that background rate is smaller than any calibration point pulse rate! |
400 |
Check validity of calibration points.
Check if calibration points number fits to selected calibration method! |
401 |
Check if calibartion points and curve are monotonic
For SOLIDS CONTENT adapt LRV or URV according the calculated values of LL and UL! |
402 |
Check coefficient values! |
403 |
Check calibration point values! |
404 |
Check system Date & Time! |
405 |
Unexpected calibration failure - Contact Berthold Technologies! |
406 |
Check validity of upper and lower range values (URV,LRV)! |
407 |
Calibration Status |
408 |
Display of actual calibration status. |
409 |
Meas Mode |
410 |
Selected measuring mode.Can be changed using Quick Start Wizard only. |
411 |
DENSITY |
412 |
CONCENTRATION |
413 |
SOLIDS CONTENT |
414 |
Cal Method |
415 |
Used calibration method. |
416 |
DIRECT ENTRY |
417 |
1-POINT |
418 |
Calibration with one point |
419 |
2-POINT |
420 |
Calibration with two points |
421 |
MULTIPOINT |
422 |
Calibration with more than two points |
423 |
Selected calibration method.Can be changed using the Quick Start Wizard only. |
424 |
Cal Mode |
425 |
Select calibration mode. |
426 |
INACTIVE |
427 |
No operation. (Idle mode) |
428 |
RECALL |
429 |
Use measurement parameter for calibration |
430 |
RESTORE |
431 |
CALIBRATE |
432 |
Start calibration calculation |
433 |
PRESET |
434 |
Cal Point No. |
435 |
Active point for the displayed calibration point informations. |
436 |
9 |
437 |
10 |
438 |
11 |
439 |
Max Nbr Cal Points |
440 |
Maxium index of calibration curve. |
441 |
01 |
442 |
02 |
443 |
03 |
444 |
04 |
445 |
05 |
446 |
06 |
447 |
07 |
448 |
08 |
449 |
09 |
450 |
Value 01 |
451 |
Value 02 |
452 |
Value 03 |
453 |
Value 04 |
454 |
Value 05 |
455 |
Value 06 |
456 |
Value 07 |
457 |
Value 08 |
458 |
Value 09 |
459 |
Value 10 |
460 |
Value 11 |
461 |
Cal Value |
462 |
Cal Point value [PV units] |
463 |
Cal Density Unit |
464 |
Rate 01 |
465 |
Rate 02 |
466 |
Rate 03 |
467 |
Rate 04 |
468 |
Rate 05 |
469 |
Rate 06 |
470 |
Rate 07 |
471 |
Rate 08 |
472 |
Rate 09 |
473 |
Rate 10 |
474 |
Rate 11 |
475 |
Selected unit used in density mode |
476 |
Selected unit used in concentration mode |
477 |
Solid Contents Unit |
478 |
Selected unit used in solid contents mode |
479 |
Measuring Path |
480 |
Enter inner diameter of pipe. |
481 |
Cal LRV |
482 |
Lower Range Value.Defines the minimum usable value within the calibration range. |
483 |
Cal URV |
484 |
Upper Range Value.Defines the maximum usable value within the calibration range. |
485 |
PV Factor |
486 |
PV Value is multiplied with this actual constant gain factor. |
487 |
PV Offset |
488 |
This actual constant offset value is added to PV Value. |
489 |
Set by User |
490 |
Coefficients are set by User |
491 |
Channel |
492 |
CHANNEL-1 |
493 |
CHANNEL-2 |
494 |
CHANNEL-3 |
495 |
CHANNEL-4 |
496 |
CHANNEL-5 |
497 |
Receiver |
498 |
Language |
499 |
English |
500 |
Deutsch |
501 |
Français |
502 |
Italiano |
503 |
Español |
504 |
Português |
505 |
Brightness |
506 |
Content |
507 |
CURRENT AO |
508 |
AVG RATE |
509 |
Format |
510 |
Acknowledge Error |
511 |
Download Start |
512 |
Download Stop |
513 |
Upload Start |
514 |
Upload Stop |
515 |
HART Serial No. |
516 |
7d |
517 |
Access Code |
518 |
Type in access code to change access level. |
519 |
8.0f |
520 |
Access Level |
521 |
Actual access level. The access levels are used to control actions that a user is allowed to perform. |
522 |
BASIC |
523 |
STANDARD |
524 |
ADMIN |
525 |
Function Check |
526 |
Enables general field device function check signaling (Cxxx Codes). |
527 |
No Function Check signaling. |
528 |
Device is signaling function check (Cxxx). |
529 |
Primary Master |
530 |
Enables specific function check signaling (Cxxx Codes) as soon as a Primary HART Master communicates with field device. |
531 |
No signaling when secondary master is active. |
532 |
Device is signaling function check (Cxxx) as long a Primary/Secondary HART Master communicates. |
533 |
Secondary Master |
534 |
Enables specific function check signaling (Cxxx Codes) as soon as a Secondary HART Master communicates with field device. |
535 |
Local User Interface |
536 |
Enables specific function check signaling (Cxxx Codes) as soon as a Local User Interface or PC communicates with field device. |
537 |
No signaling when Local User Interface is active. |
538 |
Device is signaling function check (Cxxx) as long a Local User Interface communicates. |
539 |
Module Name |
540 |
Module Ident Number |
541 |
Module Revision |
542 |
Diagnostic Behaviour |
543 |
Define signaling in cases where field device detects process alarm. |
544 |
No signaling when device detects PV alarm. |
545 |
OOS |
546 |
Device signals out of specification event code (Sxxx) as soon as PV threshold is exceeded.
The device continues to measure.
A diagnostic message is generated. |
547 |
Device signals failure event code (Fxxx) as soon as PV threshold is exceeded.
Measurement will be interrupted.
A diagnostic message is generated. |
548 |
Defines signaling in cases where field device detects temperature alarm. |
549 |
No signaling when device detects temperature alarm. |
550 |
Device signals out of specification event code (Sxxx) as soon as temperature threshold is exceeded.
The device continues to measure.
A diagnostic message is generated. |
551 |
Device signals failure event code (Fxxx) as soon as temperature threshold is exceeded.
Measurement will be interrupted.
A diagnostic message is generated. |
552 |
Reset Device |
553 |
Enable device reset mode. |
554 |
REBOOT |
555 |
FACTORY RESET |
556 |
MODIFICATION LOG RESET |
557 |
ERROR LOG RESET |
558 |
Event Group 100 |
559 |
Sytem Event Group |
560 |
Event Group 200 |
561 |
Mainboard Event Group |
562 |
Event Group 300 |
563 |
Detector Event Group |
564 |
Event Group 400 |
565 |
Application Layer(DNS) Event Group |
566 |
Event Group 500 |
567 |
CurrentOut Event Group |
568 |
Event Group 600 |
569 |
DigitalOut Event Group |
570 |
Event Group 700 |
571 |
DataLink Layer(HMI) Event Group |
572 |
Event Group 800 |
573 |
Application Layer(HMI) Event Group |
574 |
Event Group 900 |
575 |
Application Layer(HART) Event Group |
576 |
Event Log Index |
577 |
Active index of log entry. |
578 |
Event Code of log entry. |
579 |
Occurence date of log entry. |
580 |
Occurence time of log entry. |
581 |
Description |
582 |
Description of log entry. |
583 |
Bus Address Source |
584 |
DEFAULT |
585 |
HARDWARE |
586 |
SOFTWARE |
587 |
Bus Address |
588 |
Enter Profibus address of device. |
589 |
Detector Temp. Test |
590 |
Enter test value for detector temperature. |
591 |
Temp. Upper Limit |
592 |
Enter upper temperature limit of device. |
593 |
Temp. Lower Limit |
594 |
Enter lower temperature limit of device. |
595 |
Enter hysteresis for device temperature limit. |
596 |
Temp Extrema |
597 |
Enable reset of detector temperature extrema |
598 |
Reset is inactive. |
599 |
RESET |
600 |
Reset Temperature Extrema now. |
601 |
NaI 40x35 |
602 |
NaI point detector
Size 40x35mm |
603 |
Polymer 50x60 |
604 |
Polymer point detector
Size 50x60mm |
605 |
HV Manual |
606 |
Display and setpoint of HV manual. |
607 |
HV Default |
608 |
Display and setpoint of HV default. |
609 |
HV Start |
610 |
Enter HV start value for plateau measurement beginning. |
611 |
4u |
612 |
HV Stop |
613 |
Enter HV stop value for plateau measurement end. |
614 |
HV Step |
615 |
Enter HV step width for plateau measurement step width. |
616 |
Meas. Time |
617 |
Enter measuring time for each plateau measuring point. |
618 |
Plateau Records |
619 |
Plateau Date |
620 |
Plateau HV |
621 |
HV of Active displayed plateau table entry |
622 |
Plateau Impulses |
623 |
Impulses of Active displayed plateau table entry |
624 |
Error Value |
625 |
Defines current value in case of error |
626 |
Supply Mode |
627 |
Defines if the current loop is supplied by internal or external supply voltage. (Internal Supply->Source Mode / External Supply->Sink Mode) |
628 |
SINK |
629 |
SOURCE |
630 |
Ident No. |
631 |
Identification Number
- Number that is used for identification purposes by Berthold Technologies |
632 |
Serial No. |
633 |
Serial Number
- Number that is used for identification purposes by Berthold Technologies |
634 |
Lower Limit |
635 |
Enter lower limit for current output. According NE43 it is recommended to set Lower Limit value to 3.8mA |
636 |
Current Behaviour |
637 |
Enables or disables function check signaling by current value. |
638 |
Current Value |
639 |
Enter function check current value. This value is set by field device in cases where function check codes are signaled. |
640 |
Upper Limit |
641 |
Enter upper limit for current output. According NE43 it is recommended to set Upper Limit value to 20.5mA |
642 |
Relay |
643 |
Relay Test Value |
644 |
Relay Mode |
645 |
Pulse Rate |
646 |
Cal Time |
647 |
Time of last calibration (hh:mm:ss). |
648 |
Cal Date |
649 |
Date of last calibration (mm/dd/yyyy). |
650 |
Nuclide |
651 |
Select nuclide for decay compensation. |
652 |
Cs-137 |
653 |
Decay compensation will be done with Cs-137 |
654 |
Co-60 |
655 |
Decay compensation will be done with Co-60 |
656 |
Active background radiation count rate only for decay compensation. |
657 |
Read-in Time |
658 |
Enter averaging time for Read-in procedure. |
659 |
Firmware Rev. |
660 |
Firmware Rev- Information to identify the Field Device embedded software by Berthold Technologies |
661 |
Firmware Date |
662 |
Firmware Date- Time of Field Device embedded software build. This information is used by Berthold Technologies |
663 |
Feedback monitor |
664 |
Function to activate current feedback monitor function |
665 |
Plateau Index |
666 |
Active plateau table Index |
667 |
Classification |
668 |
Solids Content Unit |
669 |
Value out of limits |
670 |
Loop Warning |
671 |
Test PV |
672 |
PV simulation ON/OFF |
673 |
Test Rate |
674 |
CPS simulation ON/OFF |
675 |
Change Supply |
676 |
Method to change loop supply mode. |
677 |
post_write_upload_variables |
678 |
Reset Change Flag |
679 |
This method resets the modification flag |
680 |
Reboot |
681 |
This method performs a system reboot. |
682 |
Factory Reset |
683 |
This method performs a factory reset on the device. |
684 |
Master Reset |
685 |
This method performs a master reset on the device. |
686 |
Acknowledge |
687 |
This method allows to acknowledge actual event code |
688 |
Event Description |
689 |
This description refers to actual event code |
690 |
Event Instruction |
691 |
This instruction refers to actual event code |
692 |
Cal Help |
693 |
This help text refers to actual calibration status |
694 |
Cal Instruction |
695 |
This instruction refers to actual calibration status |
696 |
Relay DO |
697 |
Refresh Plateau |
698 |
Refresh graphical views of plateau. |
699 |
Reset |
700 |
Refresh |
701 |
Set Poll Addr |
702 |
Change HV Mode |
703 |
Method to switch HV mode between manuell and automatic |
704 |
Start / Stop |
705 |
Method to start or stop plateau measurement |
706 |
Calibrate |
707 |
The device will be calibrated using the actual configured calibration parameter set. |
708 |
Restore Upload |
709 |
Upload and decay compensation of former calibration data. |
710 |
Recall |
711 |
All calibration parameters will be overwritten with the actual used measurement parameter set. |
712 |
Read-in |
713 |
Clear |
714 |
Select Point |
715 |
Select specific calibration point |
716 |
Reset Calibration Point Index |
717 |
Quick Start Wizard |
718 |
pre_write_upload_variables |
719 |
pre_read_download_variables |
720 |
post_read_download_variables |
721 |
Current |
722 |
mA |
723 |
Rate |
724 |
Temperature |
725 |
Dynamic Variables |
726 |
Cal Table |
727 |
Index |
728 |
Value |
729 |
Meas Table |
730 |
Actually used measurement table |
731 |
Module Info |
732 |
No |
733 |
ID |
734 |
Name |
735 |
Revision |
736 |
PV Meter |
737 |
Primary variable (PV) Meter |
738 |
AO Meter |
739 |
CurrentOut(AO) Meter |
740 |
Plateau Curve |
741 |
Plateau |
742 |
HV |
743 |
V |
744 |
Plateau Table |
745 |
Event Log |
746 |
Event Counter |
747 |
Counter |
748 |
Date1 |
749 |
Time1 |
750 |
Date2 |
751 |
Time2 |
752 |
Date3 |
753 |
Time3 |
754 |
Date4 |
755 |
Time4 |
756 |
Date5 |
757 |
Time5 |
758 |
Offline View |
759 |
Identification |
760 |
Location |
761 |
Device Information |
762 |
Device Revision |
763 |
Setup |
764 |
Sstem |
765 |
Sensors |
766 |
Calibration |
767 |
Signal Condition |
768 |
Outputs |
769 |
Alarms |
770 |
Interfaces |
771 |
Units |
772 |
Formats |
773 |
Detector |
774 |
Cal Parameter |
775 |
Current AO |
776 |
Parameter Setup |
777 |
Sensor Settings |
778 |
Damping |
779 |
Tuning |
780 |
Cal Settings |
781 |
Cal Coeffs |
782 |
Process |
783 |
Diagnostics(NE107) |
784 |
Profibus Setting |
785 |
IR Remote Control |
786 |
Local Display |
787 |
Quick Diagnostics |
788 |
Online Menu |
789 |
Process Variables |
790 |
Device Setup |
791 |
Diagnostics |
792 |
Access |
793 |
User Access |
794 |
HART Master Access |
795 |
HART DO |
796 |
Simulation |
797 |
Admin |
798 |
Device Diagnostic |
799 |
HART Diagnostics |
800 |
HART Change Status |
801 |
Event Overview |
802 |
Event Group 100... |
803 |
Event Group 200... |
804 |
Event Group 300... |
805 |
Event Group 400... |
806 |
Event Group 500... |
807 |
Event Group 600... |
808 |
Event Group 700... |
809 |
Event Group 800... |
810 |
Event Group 900... |
811 |
Process Monitor |
812 |
Charts |
813 |
Trends |
814 |
System Monitor |
815 |
Active Configuration |
816 |
System |
817 |
Date / Time |
818 |
High Voltage |
819 |
Range |
820 |
Process Alarm |
821 |
Temperature Alarm |
822 |
Diagnostics Alarm (NE107) |
823 |
Cal Points |
824 |
Cal Background |
825 |
Cal Limits |
826 |
Cal Product Condition |
827 |
Detector Info |
828 |
Hardware Info |
829 |
Device Reset |
830 |
Meas Parameter |
831 |
Meas Product Condition |
832 |
Meas Coefficients |
833 |
Plateau Graph |
834 |
Plateau Data |
835 |
Plateau Measurement |
836 |
Device |
837 |
Wizard |
838 |
Process Values |
839 |
Process Overview |
840 |
Diagnostic |
841 |
Diagnostic Overview |
842 |
Device Diagnostics |
843 |
HART Device Status |
844 |
HART Communication Status |
845 |
HART Ext. Device Status |
846 |
HART Lock Device Status |
847 |
Error Log |
848 |
Event Group 108... |
849 |
Event Group 116... |
850 |
Event Group 308... |
851 |
Event Group 316... |
852 |
Event Group 408... |
853 |
Event Group 416... |
854 |
PV Simulation |
855 |
CPS Simulation |
856 |
AO Simulation |
857 |
DO Simulation |
858 |
Berthold Device |
859 |
Quick Start Image |
860 |
Device Image |
861 |
HartLogo |
862 |
Diagnostics Link |
863 |
Device Status Image |
864 |
Parameter Upload |
865 |
Parameter Download |
866 |
Device Type |
867 |
LB414 |
868 |
PV out of limits |
869 |
Process applied to the primary variable is outside the operating limits of the field device.
The PV is beyond its operating limit. |
870 |
Non PV out of limits |
871 |
Process applied to the non-primary variable is outside the operating limits of the field device
A device variable not mapped to the PV is beyond its operating limits. |
872 |
PV AO saturated |
873 |
Analog output 1 and its digital representation are outside the operating range limits, and not responding to input
The Loop current has reached its upper or lower endpoint limit and cannot increase or decrease any further. |
874 |
PV AO fixed |
875 |
Analog output 1 and its digital representation are in fixed mode, and not responsive to input changes
The Loop current is being held at a fixed value and is not responding to process variations. |
876 |
More status available |
877 |
Field device has more status available via Command 48.
Read Additional Status device specific information. |
878 |
Cold start |
879 |
A reset or self test of the field device has occurred, or power has been removed and reapplied
|
880 |
Configuration changed |
881 |
A modification has been made to the configuration of the field device |
882 |
Device malfunction |
883 |
Field device has malfunctioned due to a hardware error or failure
The device detected a serious error or failure that compromises device operation. |
884 |
Ext. Device Status |
885 |
Write Protect |
886 |
Current AO Mode |
887 |
FIXED VALUE |
888 |
Actual Current is the analogue representation of measured Process Value (usually 4-to-20mA). |
889 |
Alarm Type |
890 |
HIGH |
891 |
Current output in case of failures: 22mA |
892 |
LOW |
893 |
Current output in case of failures: 2 mA |
894 |
VALUE |
895 |
Current output in case of failures: User defined value |
896 |
Transfer Function |
897 |
LINEAR |
898 |
SQUARE |
899 |
CUBIC |
900 |
UNDEFINED |
901 |
PV % Range |
902 |
PV URV |
903 |
Defines the relationship between the Loop Current 20.0mA and the Primary Variable Upper Range Value.Defines the maximum usable value within the measurment range. |
904 |
PV LRV |
905 |
Defines the relationship between the Loop Current 4.0mA and the Primary Variable Lower Range Value.Defines the minimum usable value within the measurment range. |
906 |
Long Tag |
907 |
Communication Status |
908 |
Short Tag |
909 |
Descriptor |
910 |
Message |
911 |
Device ID |
912 |
Poll Addr |
913 |
Final Assembly No. |
914 |
Final Assembly Number
- Number that is used for identification purposes, and is associated with the overall Field Device. This number can be used by the user in any way. There is no specific recommended use. |
915 |
DD Rev. |
916 |
Device Rev. |
917 |
Software Rev. |
918 |
Universal Rev. |
919 |
No. Req Preams |
920 |
No. Resp Preams |
921 |
Modification Counter |
922 |
F200 Runtime failure |
923 |
F201 HW failure |
924 |
F201 Hardware failure detected |
925 |
F202 HW failure |
926 |
F202 Hardware failure detected |
927 |
F203 HW failure |
928 |
F203 Hardware failure detected |
929 |
F204 HW failure |
930 |
F204 Hardware failure detected |
931 |
F205 failure |
932 |
F206 failure |
933 |
F207 failure |
934 |
S416 Alarm Setup notification |
935 |
S416 Check activated Alarm Setup against new measurement configuration |
936 |
S417 OOS |
937 |
S418 OOS |
938 |
S419 OOS |
939 |
F420 failure |
940 |
F421 failure |
941 |
F422 failure |
942 |
F423 failure |
943 |
F100 HW module |
944 |
F100 Hardware module missing or not tested |
945 |
F101 Permanent memory |
946 |
F101 Permanent memory failure |
947 |
F102 Data memory |
948 |
F102 Data memory failure |
949 |
F103 Internal system failure |
950 |
S104 Real time clock OOS |
951 |
S104 Real time clock failure out of specification limits |
952 |
F105 Watchdog reset |
953 |
F105 Watchdog reset failure |
954 |
F106 Up-/Download |
955 |
F106 During up/download the data are not correctly transmitted. |
956 |
C107 Local operation |
957 |
C107 Local operation is active. |
958 |
C108 Download active |
959 |
C108 Parameter download to device is active. |
960 |
C109 Read-in active |
961 |
C109 Read-in is active. |
962 |
C110 Plateau active |
963 |
C110 Plateau measurement is active. |
964 |
C111 Calibration active |
965 |
C111 Calibration is active. |
966 |
C112 Current AO simulation |
967 |
C112 Current AO simulation is active. |
968 |
C113 PV simulation |
969 |
C113 PV simualtion is active. |
970 |
C114 DO simulation |
971 |
C114 DO simulation is active. |
972 |
S115 Real time clock OOS |
973 |
S115 Real time clock out of specification limits |
974 |
S116 Device is not calibrated |
975 |
S117 OOS |
976 |
S118 OOS |
977 |
S119 OOS |
978 |
F120 failure |
979 |
F121 failure |
980 |
F122 failure |
981 |
F123 failure |
982 |
F300 Runtime failure |
983 |
S301 DAC calibration OOS |
984 |
S301 DAC calibration values out of specification limits |
985 |
S302 ADC calibration OOS |
986 |
S302 ADC calibration values out of specification limits |
987 |
S303 Hardware failure |
988 |
S303 Hardware failure detected |
989 |
S304 Hardware failure |
990 |
S304 Hardware failure detected |
991 |
F305 Zero pulse rate measurement channel |
992 |
F305 No impulses in measurement channel |
993 |
S306 Zero pulse rate control channel |
994 |
S306 No impulses in control channel |
995 |
S307 Zero pulse rate auxiliary channel |
996 |
S307 No impulses in auxiliary channel |
997 |
S308 Zero pulse rate in reserved channel |
998 |
S308 No impulses in reserved channel |
999 |
S309 Instable pulse rate |
1000 |
F310 Pulse deviation measurement channel |
1001 |
F310 Pulse rate deviation in measurement channel |
1002 |
S311 Threshold measurement channel OOS |
1003 |
S311 Threshold measurement channel out of specification |
1004 |
S312 Threshold control channel OOS |
1005 |
S312 Threshold control channel out of specification |
1006 |
S313 Threshold auxiliary channel OOS |
1007 |
S313 Threshold auxiliary channel out of specification |
1008 |
S314 Generated HV voltage OOS |
1009 |
S314 Generated HV voltage out of specification |
1010 |
F315 HV voltage monitoring |
1011 |
F315 HV voltage monitoring failure |
1012 |
F316 HV reached its limit value |
1013 |
F317 HV lower limit failure |
1014 |
F317 HV average is 20% below default HV |
1015 |
S318 HV upper limit OOS |
1016 |
S318 HV average is 40% above default HV |
1017 |
S319 Temperature sensor malfunction |
1018 |
S319 Temperature sensor malfunction failure |
1019 |
S320 Temperature closely to max limits OOS |
1020 |
S320 Temperature closely to max limits specifications |
1021 |
F321 Temperature max limit exceeded |
1022 |
F322 Detector malfunction |
1023 |
F322 Detector malfunction failure |
1024 |
F323 Hardware failure |
1025 |
F700 Init failure |
1026 |
F701 Runtime failure |
1027 |
F702 failure |
1028 |
F703 failure |
1029 |
F704 failure |
1030 |
F705 failure |
1031 |
F706 failure |
1032 |
F707 failure |
1033 |
F800 Init failure |
1034 |
F801 Runtime failure |
1035 |
F802 failure |
1036 |
F803 failure |
1037 |
F804 failure |
1038 |
F805 failure |
1039 |
F806 failure |
1040 |
F807 failure |
1041 |
F600 Runtime failure |
1042 |
S601 Digital output malfunction |
1043 |
F602 failure |
1044 |
F603 failure |
1045 |
F604 failure |
1046 |
F605 failure |
1047 |
F606 failure |
1048 |
F607 failure |
1049 |
F400 Runtime failure |
1050 |
F401 Measurement configuration failure |
1051 |
S402 Measurement decay compensation |
1052 |
S402 Measurement decay compensation out of specification |
1053 |
S403 Calibration decay compensation |
1054 |
S403 Calibration decay compensation out of specification |
1055 |
S404 PV upper limit OOS |
1056 |
S404 PV out of upper limit specification |
1057 |
S405 PV lower limit OOS |
1058 |
S405 PV out of lower limit specification |
1059 |
F406 PV Upper limit failure |
1060 |
F406 PV Upper Limit failure |
1061 |
F407 PV Lower limit failure |
1062 |
F407 PV Lower Limit failure |
1063 |
S408 Temperature upper limit OOS |
1064 |
S408 Temperature out of upper limit specification |
1065 |
S409 Temperature lower limit OOS |
1066 |
S409 Temperature out of lower limit specification |
1067 |
F410 Temperature upper limit failure |
1068 |
F411 Temperature lower limit failure |
1069 |
S412 Restore OOS |
1070 |
S412 Configuration is out of specification |
1071 |
S413 Measurement count rate upper limit OOS |
1072 |
S413 Measurement count rate is out of upper limit specification |
1073 |
S414 Measurement count rate lower limit OOS |
1074 |
S414 Measurement count rate is out of lower limit specification |
1075 |
S415 PV Calculation OOS |
1076 |
S415 PV Calculation is out of limit specification |
1077 |
F500 Runtime failure |
1078 |
F502 CLoop monitoring failure |
1079 |
F502 Current loop monitoring failure |
1080 |
F501 CLoop deviation failure |
1081 |
F503 CLoop malfunction failure |
1082 |
F503 Current loop malfunction failure |
1083 |
F504 failure |
1084 |
F505 failure |
1085 |
F506 failure |
1086 |
F507 failure |
1087 |
F900 Runtime failure |
1088 |
F901 failure |
1089 |
F902 failure |
1090 |
F903 failure |
1091 |
F904 failure |
1092 |
F905 failure |
1093 |
F906 failure |
1094 |
F907 failure |
1095 |
Primary Variable Code |
1096 |
Device Lock Status |
1097 |
Locked |
1098 |
Locked Permanent |
1099 |
Locked by Primary Master |
1100 |
Lock / Unlock |
1101 |
Test Current |
1102 |
DAC Trim |
1103 |
PV Analog Channel Saturated |
1104 |
PV Analog Channel Fixed |
1105 |
Wireless |
1106 |
WirelessHART Device |
1107 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
1108 |
Primary |
1109 |
Primary Analog Channel |
1110 |
Secondary |
1111 |
Secondary Analog Channel |
1112 |
Tertiary |
1113 |
Tertiary Analog Channel |
1114 |
Quaternary |
1115 |
Quaternary Analog Channel |
1116 |
Quinary |
1117 |
Quinary Analog Channel |
1118 |
Critical Power Failure |
1119 |
Lock all |
1120 |
Trim not supported |
1121 |
Configuration cannot be changed |
1122 |
Locked by gateway |
1123 |
Analog Input Channel |
1124 |
Analog Output Channel |
1125 |
Secondary Analog Channel Saturated |
1126 |
Tertiary Analog Channel Saturated |
1127 |
Quaternary Analog Channel Saturated |
1128 |
Quinary Analog Channel Saturated |
1129 |
Secondary Analog Channel Fixed |
1130 |
Tertiary Analog Channel Fixed |
1131 |
Quaternary Analog Channel Fixed |
1132 |
Quinary Analog Channel Fixed |
1133 |
Simulation active |
1134 |
The device is in simulation mode and the level output is not representative of the process. |
1135 |
Non-Volatile memory failure |
1136 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
1137 |
Volatile memory error |
1138 |
The RAM memory check is invalid or maybe corrupt |
1139 |
Watchdog reset executed |
1140 |
A watchdog reset has been performed |
1141 |
Voltage conditions out of range |
1142 |
A voltage condition is outside its allowable range |
1143 |
Environmental conditions out of range |
1144 |
An internal or environmental condition is beyond acceptable limits. |
1145 |
Electronic failure |
1146 |
A hardware problem not related to the sensor has been detected. |
1147 |
Subdevice list changed |
1148 |
Duplicate master detected |
1149 |
Capacity Denied |
1150 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
1151 |
Bandwidth allocation pending |
1152 |
Block transfer pending |
1153 |
Battery life |
1154 |
Percent range |
1155 |
Loop current |
1156 |
Primary variable |
1157 |
Secondary variable |
1158 |
Tertiary variable |
1159 |
Quaternary variable |
1160 |
Read receive time |
1161 |
Write date and time |
1162 |
Non-Volatile Clock |
1163 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
1164 |
Clock Uninitialized |
1165 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
1166 |
None |
1167 |
No restrictions |
1168 |
SI Only |
1169 |
Restricted to SI Unit codes only |
1170 |
Process automation device |
1171 |
Discrete device |
1172 |
Hybrid:Process automation+discrete |
1173 |
I/O System |
1174 |
WirelessHART Process automation device |
1175 |
WirelessHART Discrete device |
1176 |
WirelessHART Process automation+discrete |
1177 |
WirelessHART Gateway |
1178 |
WirelessHART Access point |
1179 |
WirelessHART Process adapter |
1180 |
WirelessHART Discrete adapter |
1181 |
WirelessHART enabled handheld/portable maintenance tool |
1182 |
Device Profile |
1183 |
US |
1184 |
United States of America |
1185 |
JP |
1186 |
Japan |
1187 |
DE |
1188 |
Germany |
1189 |
FR |
1190 |
France |
1191 |
ES |
1192 |
Spain |
1193 |
RU |
1194 |
Russian Federation |
1195 |
CN |
1196 |
People's Republic of China |
1197 |
Device Diagnostic Status 0 |
1198 |
Device Diagnostic Status 1 |
1199 |
I/O and Subdevice Status |
1200 |
WirelessHART Status |
1201 |
Time Set Option |
1202 |
Real Time Clock Flags |
1203 |
Country |
1204 |
Country of intended device installation |
1205 |
SI Unit Control |
1206 |
Indicates if device should only display SI unit codes |
1207 |
8.3f |
1208 |
Time Stamp |
1209 |
Relative time value on network |
1210 |
8u |
1211 |
Dynamic Variables Returned for Device Variables |
1212 |
Command Response Truncated |
1213 |
Configuration Change Counter Mismatch |
1214 |
Status bytes mismatch |
1215 |
Device Variable |
1216 |
WARN - Current AO should be removed from automatic control! |
1217 |
Device is in write protect mode! |
1218 |
Device is in offline mode! |
1219 |
Activate PV simulation... |
1220 |
Deactivate PV simulation... |
1221 |
NOTE - Current AO may be returned to automatic control! |
1222 |
Activate Rate simulation... |
1223 |
Deactivate Rate simulation... |
1224 |
Loop will be switched to SOURCE MODE! |
1225 |
Changing supply mode now? |
1226 |
Cancel;Yes |
1227 |
Loop will be switched to SINK MODE! |
1228 |
WARN - HART communication will be not possible as long the loop isn't supplied externally !!! |
1229 |
Trim was not done. |
1230 |
Reset modification flag now? |
1231 |
Modification Flag is reset! |
1232 |
Reboot device now? |
1233 |
Rebooting... %{l_iProcessPercent}% |
1234 |
Updating parameters... 0% |
1235 |
Updating parameters... 2% |
1236 |
Updating parameters... 4% |
1237 |
Updating parameters... 6% |
1238 |
Updating parameters... 8% |
1239 |
Updating parameters... 10% |
1240 |
Updating parameters... 12% |
1241 |
Updating parameters... 14% |
1242 |
Updating parameters... 16% |
1243 |
Updating parameters... 18% |
1244 |
Updating parameters... 20% |
1245 |
Updating parameters... 22% |
1246 |
Updating parameters... 24% |
1247 |
Updating parameters... 26% |
1248 |
Updating parameters... 28% |
1249 |
Updating parameters... 30% |
1250 |
Updating parameters... 32% |
1251 |
Updating parameters... 34% |
1252 |
Updating parameters... 36% |
1253 |
Updating parameters... 38% |
1254 |
Updating parameters... 40% |
1255 |
Updating parameters... 42% |
1256 |
Updating parameters... 44% |
1257 |
Updating parameters... 46% |
1258 |
Updating parameters... 48% |
1259 |
Updating parameters... 50% |
1260 |
Updating parameters... 52% |
1261 |
Updating parameters... 54% |
1262 |
Updating parameters... 56% |
1263 |
Updating parameters... 58% |
1264 |
Updating parameters... 60% |
1265 |
Updating parameters... 62% |
1266 |
Updating parameters... 64% |
1267 |
Updating parameters... 66% |
1268 |
Updating parameters... 68% |
1269 |
Updating parameters... 70% |
1270 |
Updating parameters... 72% |
1271 |
Updating parameters... 74% |
1272 |
Updating parameters... 76% |
1273 |
Updating parameters... 78% |
1274 |
Updating parameters... 80% |
1275 |
Updating parameters... 82% |
1276 |
Updating parameters... 84% |
1277 |
Updating parameters... 86% |
1278 |
Updating parameters... 88% |
1279 |
Updating parameters... 90% |
1280 |
Updating parameters... 92% |
1281 |
Updating parameters... 94% |
1282 |
Updating parameters... 96% |
1283 |
Updating parameters... 98% |
1284 |
Updating parameters... 100% |
1285 |
Reset done. Reconnect the device to the HART - otherwise there might be data inconsistence. |
1286 |
Reset device now? |
1287 |
Resetting... %{l_iProcessPercent}% |
1288 |
Factory Reset done. Reconnect the device to the HART - otherwise there might be data inconsistence. |
1289 |
Master Reset done. Reconnect the device to the HART - otherwise there might be data inconsistence. |
1290 |
No event to acknowledge! |
1291 |
Event is acknowledged! |
1292 |
Event cannot be acknowledged! |
1293 |
No help needed! |
1294 |
Relay is in normal state. |
1295 |
Relay is in alarm state. |
1296 |
Select new relay state... |
1297 |
Normal-State;Alarm-State;Abort |
1298 |
Refresh Plateau data? |
1299 |
No Plateau data available |
1300 |
Refreshing Plateau record No. ... %{i_Rec} |
1301 |
Plateau records refreshed. |
1302 |
Reset Event Log now? |
1303 |
Yes;Cancel |
1304 |
Resetting Event Log... %{l_iProcessPercent}% |
1305 |
******** |
1306 |
Event Log reset done! |
1307 |
Refresh Event Log? |
1308 |
Refreshing Event Log... %{l_iProcessPercent}% |
1309 |
F |
1310 |
S |
1311 |
C |
1312 |
M |
1313 |
100 |
1314 |
101 |
1315 |
102 |
1316 |
103 |
1317 |
104 |
1318 |
105 |
1319 |
106 |
1320 |
107 |
1321 |
108 |
1322 |
109 |
1323 |
110 |
1324 |
111 |
1325 |
112 |
1326 |
113 |
1327 |
114 |
1328 |
115 |
1329 |
116 |
1330 |
117 |
1331 |
118 |
1332 |
119 |
1333 |
120 |
1334 |
121 |
1335 |
122 |
1336 |
123 |
1337 |
200 |
1338 |
201 |
1339 |
202 |
1340 |
203 |
1341 |
204 |
1342 |
205 |
1343 |
206 |
1344 |
207 |
1345 |
300 |
1346 |
301 |
1347 |
302 |
1348 |
303 |
1349 |
304 |
1350 |
305 |
1351 |
306 |
1352 |
307 |
1353 |
308 |
1354 |
309 |
1355 |
310 |
1356 |
311 |
1357 |
312 |
1358 |
313 |
1359 |
314 |
1360 |
315 |
1361 |
316 |
1362 |
317 |
1363 |
318 |
1364 |
319 |
1365 |
320 |
1366 |
321 |
1367 |
322 |
1368 |
323 |
1369 |
400 |
1370 |
401 |
1371 |
402 |
1372 |
403 |
1373 |
404 |
1374 |
405 |
1375 |
406 |
1376 |
407 |
1377 |
408 |
1378 |
409 |
1379 |
410 |
1380 |
411 |
1381 |
412 |
1382 |
413 |
1383 |
414 |
1384 |
415 |
1385 |
416 |
1386 |
417 |
1387 |
418 |
1388 |
419 |
1389 |
420 |
1390 |
421 |
1391 |
422 |
1392 |
423 |
1393 |
500 |
1394 |
501 |
1395 |
502 |
1396 |
503 |
1397 |
504 |
1398 |
505 |
1399 |
506 |
1400 |
507 |
1401 |
600 |
1402 |
601 |
1403 |
602 |
1404 |
603 |
1405 |
604 |
1406 |
605 |
1407 |
606 |
1408 |
607 |
1409 |
700 |
1410 |
701 |
1411 |
702 |
1412 |
703 |
1413 |
704 |
1414 |
705 |
1415 |
706 |
1416 |
707 |
1417 |
800 |
1418 |
801 |
1419 |
802 |
1420 |
803 |
1421 |
804 |
1422 |
805 |
1423 |
806 |
1424 |
807 |
1425 |
900 |
1426 |
901 |
1427 |
902 |
1428 |
903 |
1429 |
904 |
1430 |
905 |
1431 |
906 |
1432 |
907 |
1433 |
Event Log refresh done. |
1434 |
Select event group to refresh:
|
1435 |
Refresh %{var_ds_eErrorCounterGroup} ? |
1436 |
Refreshing %{var_ds_eErrorCounterGroup}... %{l_iProcessPercent}% |
1437 |
%{var_ds_eErrorCounterGroup} refresh done. |
1438 |
Reset event counter now? |
1439 |
Resetting event counter... %{l_iProcessPercent}% |
1440 |
Event counter reset done! |
1441 |
Refresh module table from device? |
1442 |
Refreshing... %{l_iProcessPercent}% |
1443 |
Module table refresh done. |
1444 |
Set Polling Address |
1445 |
Set HV mode to manual? |
1446 |
HV mode has changed |
1447 |
Set HV mode to automatic? |
1448 |
Plateau measurement is running. Abort Plateau measurement? |
1449 |
Plateau measurement aborted |
1450 |
Start Plateau measurement? |
1451 |
Plateau measurement is running...
Parameter HV_Mode is signaling actual status. |
1452 |
WARN - This action will overwrite your measurement configuration! |
1453 |
Performing calibration... 0% |
1454 |
Performing calibration... 7% |
1455 |
Performing calibration... 14% |
1456 |
Performing calibration... 21% |
1457 |
Performing calibration... 28% |
1458 |
Performing calibration... 38% |
1459 |
Performing calibration... 45% |
1460 |
Performing calibration... 52% |
1461 |
Performing calibration... 59% |
1462 |
Performing calibration... 66% |
1463 |
Performing calibration... 72% |
1464 |
Performing calibration... 78% |
1465 |
Performing calibration... 84% |
1466 |
Performing calibration... 90% |
1467 |
Performing calibration... 100% |
1468 |
Calibration aborted.
Code: %{var_ds_eCalibrationStatus}
Check help and instruction! |
1469 |
Calibration was performed successfully! |
1470 |
WARN - Be aware that PV alarm setup must be adapted to changed measurement configuration! |
1471 |
WARN - This action will overwrite your measurement settings! |
1472 |
Performing restore... 0% |
1473 |
Performing restore... 7% |
1474 |
Performing restore... 14% |
1475 |
Performing restore... 21% |
1476 |
Performing restore... 31% |
1477 |
Performing restore... 38% |
1478 |
Performing restore... 45% |
1479 |
Performing restore... 52% |
1480 |
Performing restore... 59% |
1481 |
Performing calibration... 65% |
1482 |
Performing restore... 74% |
1483 |
Performing restore... 82% |
1484 |
Performing restore... 90% |
1485 |
Performing restore... 100% |
1486 |
Restore aborted.
Code: %{var_ds_eCalibrationStatus}
Help: %{var_ls_eCalibrationStatusHelp}.
Instruction: %{var_ls_eCalibrationStatusInstruction}. |
1487 |
Calibration was performed successfully |
1488 |
WARN - All calibration parameters will be overwritten with the actual used measurement parameters! |
1489 |
Performing recall... 0% |
1490 |
Performing recall... 10% |
1491 |
Performing recall... 20% |
1492 |
Performing recall... 30% |
1493 |
Performing recall... 45% |
1494 |
Performing recall... 60% |
1495 |
Performing recall... 80% |
1496 |
Performing recall... 90% |
1497 |
Performing recall... 100% |
1498 |
A Copy of measuring data wa successfully loaded to calibration parameter! |
1499 |
Read-in is still active! |
1500 |
Read-in - calibration point %{l_iCalPoint}
Rate = %{0} cps
Remaining Time = %{1} s |
1501 |
Read-in finished. |
1502 |
Calibration point rate has to be greater than background rate!
|
1503 |
Read-in is still active |
1504 |
Read-in - background rate
Rate = %{1} cps
Remaining Time = %{0} s |
1505 |
Read-in aborted! |
1506 |
Clear calibration table? |
1507 |
Clearing... (Cal Point No.: %{l_iItem}) |
1508 |
Calibration table cleared. |
1509 |
Nothing to edit in this mode! |
1510 |
Select cal. point |
1511 |
Point-1 |
1512 |
Point-1;Point-2 |
1513 |
Point-1;Point-2;Point-3;Point-4;Point-5;Point-6;Point-7;Point-8;Point-9;Point-10;Point-11 |
1514 |
Device is offline! |
1515 |
Refreshing table... 21% |
1516 |
Refreshing table... 28% |
1517 |
Refreshing table... 38% |
1518 |
Refreshing table... 45% |
1519 |
Refreshing table... 52% |
1520 |
Refreshing table... 59% |
1521 |
Refreshing table... 66% |
1522 |
Refreshing table... 68% |
1523 |
Refreshing table... 70% |
1524 |
Refreshing table... 78% |
1525 |
Refreshing table... 84% |
1526 |
Refreshing table... 90% |
1527 |
Refreshing table... 100% |
1528 |
Table update succeeded! |
1529 |
Cleaning up wizard... 0% |
1530 |
Cleaning up wizard... 25% |
1531 |
Cleaning up wizard... 50% |
1532 |
Cleaning up wizard... 75% |
1533 |
Cleaning up wizard... 100% |
1534 |
Cannot run wizard cleanup cause device is in write protect mode! |
1535 |
Unexpected error occured during device configuration!
- Check configuration input parameters
- Check device communcication
- Try again |
1536 |
Unexpected error occured during device calibration!
- Check configuration input parameters
- Check device communcication
- Try again |
1537 |
Unexpected error occured during device recall procedure!
- Check configuration input parameters
- Check device communcication
- Try again |
1538 |
Welcome to the LB414 SmartSeries Wizard!
This wizard automates the most common tasks involving the device setup.
Click "OK" button to proceed... |
1539 |
Wizard loading ... |
1540 |
Loading... |
1541 |
Would you like to run new calibration or recall actual measurement parameter set? |
1542 |
New;Recall;Abort |
1543 |
Change system Date?
%{0} (mm/dd/yyyy)
|
1544 |
Skip;Edit;Back;Abort |
1545 |
System Date (mm/dd/yyyy)
Set day...
|
1546 |
l_iDay |
1547 |
Change system Date %{0} (mm/dd/yyyy)
Edit day...
|
1548 |
System Date (mm/dd/yyyy)
Set month...
|
1549 |
l_iMonth |
1550 |
Change system Date %{0} (mm/dd/yyyy)
Edit month...
|
1551 |
System Date (mm/dd/yyyy)
Set year...
|
1552 |
l_iYear |
1553 |
Change system Date %{0} (mm/dd/yyyy)
Edit year...
|
1554 |
Change system Time?
%{0} (hh:mm:ss)
|
1555 |
Set system Time
%{0} (hh:mm:ss)
|
1556 |
Change detector type?
%{0}
|
1557 |
Edit detector type...
%{0}
|
1558 |
Change nuclide?
%{0}
|
1559 |
Edit nuclide...
%{0}
|
1560 |
Change measurement mode?
%{0}
|
1561 |
Skip;DENSITY;CONCENTRATION;SOLIDS CONTENT;Back;Abort |
1562 |
Change system unit?
%{0}
|
1563 |
Skip;g/cm³;kg/m³;lb/gal;lb/ft³;g/l;SGU;Back;Abort |
1564 |
PV unit is constantly fixed to %{0}
|
1565 |
Continue;Back;Abort |
1566 |
Change calibration method?
%{0}
|
1567 |
Skip;DIRECT;1-POINT;2-POINT;MULTIPOINT;Back;Abort |
1568 |
Skip;DIRECT;1-POINT;MULTIPOINT;Back;Abort |
1569 |
Select number of calibration points? |
1570 |
3-POINTS;4-POINTS;5-POINTS;6-POINTS;7-POINTS;8-POINTS;9-POINTS;10-POINTS;11-POINTS;Back;Abort |
1571 |
2-POINTS;3-POINTS;4-POINTS;5-POINTS;6-POINTS;7-POINTS;8-POINTS;9-POINTS;10-POINTS;11-POINTS;Back;Abort |
1572 |
Change measuring path?
%{0} %{1}
|
1573 |
Invalid Measuring Path value! |
1574 |
Edit measuring path...
%{0} %{1}
|
1575 |
Invalid measuring path value! |
1576 |
Would you like to read-in pulse rates automatically? |
1577 |
Yes;No;Back;Abort |
1578 |
Edit read-in Time...
%{0} s
|
1579 |
Invalid read-in Time! |
1580 |
Change background rate?
%{0} cps
|
1581 |
Edit background rate...
%{var_lf_CountRate} cps
|
1582 |
Invalid background rate! |
1583 |
Ready to start background read-in? |
1584 |
Yes;Skip;Back;Abort |
1585 |
Ready to enter calibration points? |
1586 |
Edit calibration point value #%{0}...
%{1} %{2}
|
1587 |
Edit calibration point rate #%{0}...
%{1} cps
|
1588 |
Calibration point rate has to be greater than background rate! |
1589 |
Ready to start calibration points Read-in? |
1590 |
Change calibration point #%{0}?
%{1} %{2} %{3} cps |
1591 |
Read-in;Skip;Abort |
1592 |
Edit calibration point #%{0}...
%{1} %{2} |
1593 |
Ready to enter coefficients? |
1594 |
Yes;Back;Abort |
1595 |
Ready to enter coefficient? |
1596 |
Enter coefficient directly? |
1597 |
Edit coefficient #%{0}...
%{1}
|
1598 |
l_fValue |
1599 |
Edit coefficient #%{0}...
%{1} cm²/g
|
1600 |
Edit coefficient #%{0}...
%{1} cm4/g²
|
1601 |
Edit coefficient #%{0}...
%{1} 1/cm
|
1602 |
Enter Abs.Coefficient
%{0} cm²/g
|
1603 |
Invalid Abs.Coefficient value! |
1604 |
Edit Abs.Coefficient...
%{var_lf_COEFF_Value} cm²/g
|
1605 |
Enter liquid density
%{0} %{1}
|
1606 |
Invalid liquid density value! |
1607 |
Edit liquid density...
%{0} %{1}
|
1608 |
Enter solid density
%{0} %{1}
|
1609 |
Invalid solid density value! |
1610 |
Edit solid density...
%{0} %{1} |
1611 |
Solid density value has to be greater than liquid density value! |
1612 |
Change lower range value (LRV)?
%{0} %{1}
|
1613 |
Edit lower range value (LRV)...
%{0} %{1}
|
1614 |
Change upper range value (URV)?
%{0} %{1}
|
1615 |
Edit upper range value (URV)...
%{0} %{1}
|
1616 |
Change damping value?
%{0} s
|
1617 |
Invalid damping value! |
1618 |
Edit damping value...
%{0} s
|
1619 |
Unexpected read-in mode. Aborting Quick Start Wizard... |
1620 |
Read-in background rate
Rate = %{1} cps
Remaining Time = %{2} s |
1621 |
Read-in calibration point #%{0}
Rate = %{1} cps
Remaining Time = %{2} s |
1622 |
Read-in background rate
Rate = %{0} cps
Read-in finished. |
1623 |
Read-in - calibration point #%{0}
Rate = %{1} cps
Read-in finished. |
1624 |
Next step will write configuration to device.
Would you like to proceed? |
1625 |
Writing configuration... 0% |
1626 |
Writing configuration... 10% |
1627 |
Writing configuration... 20% |
1628 |
Writing configuration... 30% |
1629 |
Writing configuration... 40% |
1630 |
Writing configuration... 50% |
1631 |
Writing configuration... 60% |
1632 |
Writing configuration... 65% |
1633 |
Writing configuration... 71% |
1634 |
Writing configuration... 70% |
1635 |
Writing configuration... 75% |
1636 |
Writing configuration... 80% |
1637 |
Writing configuration... 90% |
1638 |
Writing configuration... 100% |
1639 |
Writing to device succeeded!
Would you like to proceed? |
1640 |
Calibrate;Exit without Calibration |
1641 |
Quick Start Wizard finished.
Click "OK" button to proceed ... |
1642 |
Performing calibration... 70% |
1643 |
Calibration aborted.
Code: %{var_ds_eCalibrationStatus}
- %{var_ls_eCalibrationStatusHelp}
- %{var_ls_eCalibrationStatusInstruction} |
1644 |
Calibration was performed successfully!
Quick Start Wizard finished.
Click "OK" button to proceed ... |
1645 |
Begin Write to Device |
1646 |
Download aborted, device is in write protect mode. |
1647 |
End Read from Device |
1648 |
Returning Current AO to normal operation mode ... |
1649 |
Select Current AO value ... |
1650 |
4mA;20mA;Other;End |
1651 |
Current AO Value |
1652 |
Aborting method due to last error |
1653 |
Current AO is fixed at %0 mA |
1654 |
Connect ampere meter to Current AO ... |
1655 |
Current AO will be fixed at 4mA ! |
1656 |
Current AO is fixed at 4mA ! |
1657 |
Aborting method due to last error... |
1658 |
Enter ampere meter value... |
1659 |
Is Current AO output correct? (%0 mA) |
1660 |
Yes;No |
1661 |
Current AO will be fixed at 20mA ! |
1662 |
Current AO is fixed at 20mA ! |