0 |
SVP-V2 |
1 |
Manufacturer- References a specific manufacturer, which is usually a company name, that is responsible for the manufacture of this Field Device. |
2 |
Azbil Corporation |
3 |
Private Distributor |
4 |
Private Distributor- References the company that is responsible for the distribution of this Field Device to customers. |
5 |
Device ID |
6 |
Device ID- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. |
7 |
HART Version |
8 |
HART Version- Revision of the Universal Device Description, that the Field Device conforms to. |
9 |
Device Revision |
10 |
Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to. |
11 |
Software Revision |
12 |
Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device. |
13 |
Device Tag |
14 |
Device Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. |
15 |
Long Tag |
16 |
Polling Address |
17 |
Final Assembly Number |
18 |
Request Preambles Number |
19 |
Request Preambles Number- Number of Preambles required from the Host request by the Field Device. |
20 |
URV (Open) |
21 |
LRV (Shut) |
22 |
.2f |
23 |
STATUS 1-0 |
24 |
STATUS 1-1 |
25 |
STATUS 1-2 |
26 |
STATUS 1-3 |
27 |
STATUS 1-4 |
28 |
STATUS 1-5 |
29 |
STATUS 1-6 |
30 |
STATUS 1-7 |
31 |
STATUS 2-0 |
32 |
STATUS 2-1 |
33 |
STATUS 2-2 |
34 |
STATUS 2-3 |
35 |
SIMULATION MODE |
36 |
EXT SWITCH ACTIVE |
37 |
STATUS 2-6 |
38 |
STATUS 2-7 |
39 |
STATUS 3-0 |
40 |
STATUS 3-1 |
41 |
STATUS 3-2 |
42 |
STATUS 3-3 |
43 |
STATUS 3-4 |
44 |
STATUS 3-5 |
45 |
STATUS 3-6 |
46 |
STATUS 3-7 |
47 |
STATUS 4-0 |
48 |
STATUS 4-1 |
49 |
STATUS 4-2 |
50 |
STATUS 4-3 |
51 |
STATUS 4-4 |
52 |
STATUS 4-5 |
53 |
STATUS 4-6 |
54 |
STATUS 4-7 |
55 |
STATUS 5-0 |
56 |
CUT OFF LO |
57 |
CUT OFF HI |
58 |
STATUS 5-3 |
59 |
STATUS 5-4 |
60 |
STATUS 5-5 |
61 |
STATUS 5-6 |
62 |
STATUS 5-7 |
63 |
STATUS 6-0 |
64 |
STATUS 6-1 |
65 |
STATUS 6-2 |
66 |
STATUS 6-3 |
67 |
STATUS 6-4 |
68 |
STATUS 6-5 |
69 |
STATUS 6-6 |
70 |
STATUS 6-7 |
71 |
VTD FAULT |
72 |
LOW IIN |
73 |
STATUS 15-2 |
74 |
STATUS 15-3 |
75 |
STATUS 15-4 |
76 |
RAM FAULT |
77 |
ROM FAULT |
78 |
STATUS 15-7 |
79 |
OVER TEMP |
80 |
STATUS 16-1 |
81 |
MANUAL MODE |
82 |
FIXED EPM OUT |
83 |
STATUS 16-4 |
84 |
STATUS 16-5 |
85 |
STATUS 16-6 |
86 |
STATUS 16-7 |
87 |
STATUS 17-0 |
88 |
EXT ZERO ACTIVE |
89 |
STATUS 17-2 |
90 |
STATUS 17-3 |
91 |
STATUS 17-4 |
92 |
STATUS 17-5 |
93 |
STATUS 17-6 |
94 |
STATUS 17-7 |
95 |
Total Stroke Alarm |
96 |
Shut-Off Count Alarm |
97 |
Cycle Count Alarm |
98 |
Max Tvl Speed+ Alarm |
99 |
Max Tvl Speed- Alarm |
100 |
Stick Slip Alarm |
101 |
Deviation+ Alarm |
102 |
Deviation- Alarm |
103 |
Temp High Alarm |
104 |
Temp Low Alarm |
105 |
0% Tvl Error + Alarm |
106 |
0% Tvl Error - Alarm |
107 |
STATUS 19-4 |
108 |
STATUS 19-5 |
109 |
STATUS 19-6 |
110 |
STATUS 19-7 |
111 |
STATUS 20-0 |
112 |
STATUS 20-1 |
113 |
STATUS 20-2 |
114 |
STATUS 20-3 |
115 |
STATUS 20-4 |
116 |
STATUS 20-5 |
117 |
STATUS 20-6 |
118 |
STATUS 20-7 |
119 |
STATUS 21-0 |
120 |
STATUS 21-1 |
121 |
STATUS 21-2 |
122 |
STATUS 21-3 |
123 |
STATUS 21-4 |
124 |
STATUS 21-5 |
125 |
STATUS 21-6 |
126 |
STATUS 21-7 |
127 |
STATUS 22-0 |
128 |
STATUS 22-1 |
129 |
STATUS 22-2 |
130 |
STATUS 22-3 |
131 |
STATUS 22-4 |
132 |
STATUS 22-5 |
133 |
STATUS 22-6 |
134 |
STATUS 22-7 |
135 |
STATUS 23-0 |
136 |
STATUS 23-1 |
137 |
STATUS 23-2 |
138 |
STATUS 23-3 |
139 |
STATUS 23-4 |
140 |
STATUS 23-5 |
141 |
STATUS 23-6 |
142 |
STATUS 23-7 |
143 |
STATUS 24-0 |
144 |
STATUS 24-1 |
145 |
STATUS 24-2 |
146 |
STATUS 24-3 |
147 |
STATUS 24-4 |
148 |
STATUS 24-5 |
149 |
STATUS 24-6 |
150 |
STATUS 24-7 |
151 |
STATUS 25-0 |
152 |
STATUS 25-1 |
153 |
STATUS 25-2 |
154 |
STATUS 25-3 |
155 |
STATUS 25-4 |
156 |
STATUS 25-5 |
157 |
STATUS 25-6 |
158 |
STATUS 25-7 |
159 |
Actuator Action |
160 |
Direct |
161 |
Reverse |
162 |
Positioner Action |
163 |
Flow Type |
164 |
Linear |
165 |
Equal Percent |
166 |
Quick Open |
167 |
User-defined |
168 |
cmd133_dummy1 |
169 |
cmd133_dummy2 |
170 |
Valve Action |
171 |
Act. Size/Gland Packing Type |
172 |
Param0 |
173 |
Param1/Heavy |
174 |
Param1/Medium |
175 |
Param1/Light |
176 |
ParamA |
177 |
ParamB |
178 |
ParamC |
179 |
Param2/Heavy |
180 |
Param2/Medium |
181 |
Param2/Light |
182 |
Param3/Heavy |
183 |
Param3/Medium |
184 |
Param3/Light |
185 |
Param4/Heavy |
186 |
Param4/Medium |
187 |
Param4/Light |
188 |
Param5/Heavy |
189 |
Param5/Medium |
190 |
Param5/Light |
191 |
Param6/Heavy |
192 |
Param6/Medium |
193 |
Param6/Light |
194 |
Param7/Heavy |
195 |
Param7/Medium |
196 |
Param7/Light |
197 |
Param8/Heavy |
198 |
Param8/Medium |
199 |
Param8/Light |
200 |
Param9/Heavy |
201 |
Param9/Medium |
202 |
Param9/Light |
203 |
Positioner Status 1 |
204 |
Valve travel detector error. |
205 |
Input signal too low. |
206 |
RAM error. |
207 |
ROM error. |
208 |
Positioner Status 2 |
209 |
The detected internal temperature of the device is below -45 degC or above +85 degC. |
210 |
Dummy input signal operation. |
211 |
Dummy drive signal operation. |
212 |
ALL SETTINGS RESET |
213 |
The settings have been reset to the default settings.
Contact appropriate personnel. |
214 |
Positioner Status 3 |
215 |
External zero/span adjustment is being made. |
216 |
HI/LO EPM OUT |
217 |
Electro-pnenumatic module is outside normal range. |
218 |
TRAVEL CUTOFF |
219 |
Travel Cutoff High or Low is working.
The valve should be forced fully opened or closed. |
220 |
azbil S/W Version |
221 |
0.0 |
222 |
0.1 |
223 |
0.2 |
224 |
0.3 |
225 |
0.4 |
226 |
0.5 |
227 |
0.6 |
228 |
0.7 |
229 |
0.8 |
230 |
0.9 |
231 |
0.A |
232 |
0.B |
233 |
0.C |
234 |
0.D |
235 |
0.E |
236 |
0.F |
237 |
1.0 |
238 |
1.1 |
239 |
1.2 |
240 |
1.3 |
241 |
1.4 |
242 |
1.5 |
243 |
1.6 |
244 |
1.7 |
245 |
1.8 |
246 |
1.9 |
247 |
1.A |
248 |
1.B |
249 |
1.C |
250 |
1.D |
251 |
1.E |
252 |
1.F |
253 |
2.0 |
254 |
2.1 |
255 |
2.2 |
256 |
2.3 |
257 |
2.4 |
258 |
2.5 |
259 |
2.6 |
260 |
2.7 |
261 |
2.8 |
262 |
2.9 |
263 |
2.A |
264 |
2.B |
265 |
2.C |
266 |
2.D |
267 |
2.E |
268 |
2.F |
269 |
3.0 |
270 |
3.1 |
271 |
3.2 |
272 |
3.3 |
273 |
3.4 |
274 |
3.5 |
275 |
3.6 |
276 |
3.7 |
277 |
3.8 |
278 |
3.9 |
279 |
3.A |
280 |
3.B |
281 |
3.C |
282 |
3.D |
283 |
3.E |
284 |
3.F |
285 |
4.0 |
286 |
4.1 |
287 |
4.2 |
288 |
4.3 |
289 |
4.4 |
290 |
4.5 |
291 |
4.6 |
292 |
4.7 |
293 |
4.8 |
294 |
4.9 |
295 |
4.A |
296 |
4.B |
297 |
4.C |
298 |
4.D |
299 |
4.E |
300 |
4.F |
301 |
5.0 |
302 |
5.1 |
303 |
5.2 |
304 |
5.3 |
305 |
5.4 |
306 |
5.5 |
307 |
5.6 |
308 |
5.7 |
309 |
5.8 |
310 |
5.9 |
311 |
5.A |
312 |
5.B |
313 |
5.C |
314 |
5.D |
315 |
5.E |
316 |
5.F |
317 |
6.0 |
318 |
6.1 |
319 |
6.2 |
320 |
6.3 |
321 |
6.4 |
322 |
6.5 |
323 |
6.6 |
324 |
6.7 |
325 |
6.8 |
326 |
6.9 |
327 |
6.A |
328 |
6.B |
329 |
6.C |
330 |
6.D |
331 |
6.E |
332 |
6.F |
333 |
7.0 |
334 |
7.1 |
335 |
7.2 |
336 |
7.3 |
337 |
7.4 |
338 |
7.5 |
339 |
7.6 |
340 |
7.7 |
341 |
7.8 |
342 |
7.9 |
343 |
7.A |
344 |
7.B |
345 |
7.C |
346 |
7.D |
347 |
7.E |
348 |
7.F |
349 |
8.0 |
350 |
8.1 |
351 |
8.2 |
352 |
8.3 |
353 |
8.4 |
354 |
8.5 |
355 |
8.6 |
356 |
8.7 |
357 |
8.8 |
358 |
8.9 |
359 |
8.A |
360 |
8.B |
361 |
8.C |
362 |
8.D |
363 |
8.E |
364 |
8.F |
365 |
9.0 |
366 |
9.1 |
367 |
9.2 |
368 |
9.3 |
369 |
9.4 |
370 |
9.5 |
371 |
9.6 |
372 |
9.7 |
373 |
9.8 |
374 |
9.9 |
375 |
9.A |
376 |
9.B |
377 |
9.C |
378 |
9.D |
379 |
9.E |
380 |
9.F |
381 |
A.0 |
382 |
A.1 |
383 |
A.2 |
384 |
A.3 |
385 |
A.4 |
386 |
A.5 |
387 |
A.6 |
388 |
A.7 |
389 |
A.8 |
390 |
A.9 |
391 |
A.A |
392 |
A.B |
393 |
A.C |
394 |
A.D |
395 |
A.E |
396 |
A.F |
397 |
B.0 |
398 |
B.1 |
399 |
B.2 |
400 |
B.3 |
401 |
B.4 |
402 |
B.5 |
403 |
B.6 |
404 |
B.7 |
405 |
B.8 |
406 |
B.9 |
407 |
B.A |
408 |
B.B |
409 |
B.C |
410 |
B.D |
411 |
B.E |
412 |
B.F |
413 |
C.0 |
414 |
C.1 |
415 |
C.2 |
416 |
C.3 |
417 |
C.4 |
418 |
C.5 |
419 |
C.6 |
420 |
C.7 |
421 |
C.8 |
422 |
C.9 |
423 |
C.A |
424 |
C.B |
425 |
C.C |
426 |
C.D |
427 |
C.E |
428 |
C.F |
429 |
D.0 |
430 |
D.1 |
431 |
D.2 |
432 |
D.3 |
433 |
D.4 |
434 |
D.5 |
435 |
D.6 |
436 |
D.7 |
437 |
D.8 |
438 |
D.9 |
439 |
D.A |
440 |
D.B |
441 |
D.C |
442 |
D.D |
443 |
D.E |
444 |
D.F |
445 |
E.0 |
446 |
E.1 |
447 |
E.2 |
448 |
E.3 |
449 |
E.4 |
450 |
E.5 |
451 |
E.6 |
452 |
E.7 |
453 |
E.8 |
454 |
E.9 |
455 |
E.A |
456 |
E.B |
457 |
E.C |
458 |
E.D |
459 |
E.E |
460 |
E.F |
461 |
F.0 |
462 |
F.1 |
463 |
F.2 |
464 |
F.3 |
465 |
F.4 |
466 |
F.5 |
467 |
F.6 |
468 |
F.7 |
469 |
F.8 |
470 |
F.9 |
471 |
F.A |
472 |
F.B |
473 |
F.C |
474 |
F.D |
475 |
F.E |
476 |
F.F |
477 |
S/W Version |
478 |
Fail safe direction |
479 |
IIN_mA |
480 |
5.2f |
481 |
Travel |
482 |
Temperature |
483 |
Drive signal |
484 |
Input (%) |
485 |
%IIN |
486 |
%Duty |
487 |
P |
488 |
1/% |
489 |
.3f |
490 |
I |
491 |
D |
492 |
.4f |
493 |
GE(+/-) |
494 |
GP |
495 |
GI |
496 |
GD |
497 |
0% Travel Angle |
498 |
100% Travel Angle |
499 |
Stroke Time |
500 |
Hysteresis Rate |
501 |
User Data IN1 |
502 |
User Data IN2 |
503 |
User Data IN3 |
504 |
User Data IN4 |
505 |
User Data IN5 |
506 |
User Data IN6 |
507 |
User Data IN7 |
508 |
User Data IN8 |
509 |
User Data IN9 |
510 |
User Data IN10 |
511 |
User Data IN11 |
512 |
User Data IN12 |
513 |
User Data IN13 |
514 |
User Data IN14 |
515 |
User Data IN15 |
516 |
User Data IN16 |
517 |
User Data OUT1 |
518 |
User Data OUT2 |
519 |
User Data OUT3 |
520 |
User Data OUT4 |
521 |
User Data OUT5 |
522 |
User Data OUT6 |
523 |
User Data OUT7 |
524 |
User Data OUT8 |
525 |
User Data OUT9 |
526 |
User Data OUT10 |
527 |
User Data OUT11 |
528 |
User Data OUT12 |
529 |
User Data OUT13 |
530 |
User Data OUT14 |
531 |
User Data OUT15 |
532 |
User Data OUT16 |
533 |
Input (mA) |
534 |
Drive Signal |
535 |
Mode |
536 |
Out of service |
537 |
In service |
538 |
Travel Cutoff High |
539 |
Travel Cutoff Low |
540 |
PROM No. |
541 |
Stick slip N |
542 |
5u |
543 |
Stick Slip X |
544 |
.8f |
545 |
Stick Slip Y |
546 |
Stick Slip Count |
547 |
3u |
548 |
Stick Slip Count Threshold |
549 |
Stick Slip XY Threshold |
550 |
Total Stroke |
551 |
Dead Band |
552 |
Total Stroke Threshold |
553 |
Cycle Count |
554 |
Cycle |
555 |
10u |
556 |
Cycle Count High |
557 |
Cycle Count Low |
558 |
Cycle Count Threshold |
559 |
Travel Histogram 1 |
560 |
Travel Histogram 2 |
561 |
Travel Histogram 3 |
562 |
Travel Histogram 4 |
563 |
Travel Histogram 5 |
564 |
Travel Histogram 6 |
565 |
Travel Histogram 7 |
566 |
Travel Histogram 8 |
567 |
Travel Histogram 9 |
568 |
Travel Histogram 10 |
569 |
Travel Histogram 11 |
570 |
Travel Histogram 12 |
571 |
Travel Histogram 13 |
572 |
Travel Histogram 14 |
573 |
Travel Histogram 15 |
574 |
Travel Histogram 16 |
575 |
Travel Segment 1 |
576 |
Travel Segment 2 |
577 |
Travel Segment 3 |
578 |
Travel Segment 4 |
579 |
Travel Segment 5 |
580 |
Travel Segment 6 |
581 |
Travel Segment 7 |
582 |
Travel Segment 8 |
583 |
Travel Segment 9 |
584 |
Travel Segment 10 |
585 |
Travel Segment 11 |
586 |
Travel Segment 12 |
587 |
Travel Segment 13 |
588 |
Travel Segment 14 |
589 |
Travel Segment 15 |
590 |
Travel Segment 16 |
591 |
0% Tvl Error + |
592 |
0% Tvl Error - |
593 |
0% Tvl Error Waiting Time |
594 |
0% travel error |
595 |
Shut-Off Count Threshold |
596 |
Count |
597 |
Shut-Off Count |
598 |
Max Tvl Speed Threshold + |
599 |
%/s |
600 |
Max Tvl Speed Threshold - |
601 |
Max Tvl Speed + |
602 |
Max Tvl Speed - |
603 |
Deviation Threshold + |
604 |
Deviation Threshold - |
605 |
Deviation Waiting Time |
606 |
Deviation |
607 |
Temp Threshold High |
608 |
Temp Threshold Low |
609 |
Temp Wating Time |
610 |
Stick Slip Alarm Enabled |
611 |
Disabled |
612 |
Enabled |
613 |
Total Stroke Alarm Enabled |
614 |
Cycle Count Alarm Enabled |
615 |
cmd188_dummy1 |
616 |
0% Tvl Error Alarm Enabled |
617 |
Shut-Off Count Alarm Enabled |
618 |
Max Tvl Speed Alarm Enabled |
619 |
Deviation Alarm Enabled |
620 |
Temp Alarm Enabled |
621 |
cmd188_dummy2 |
622 |
Valve Status 1 |
623 |
Total Stroke alerts when the totalized distance of the valve plug/stem stroke movement exceeds the threshold value. |
624 |
Shut-Off Count alerts when the totalized number of valve closure exceeds the threshold value. |
625 |
Cycle Count alerts when the number of control valve reverse operation cycles exceeds the threshold value. |
626 |
Max Tvl Speed + Alarm |
627 |
Max Tvl Speed + alerts when the maximum stem movement speed of upward direction in a day exceeds the threshold value. |
628 |
Max Tvl Speed - Alarm |
629 |
Max Tvl Speed - alerts when the maximum stem movement speed of downward direction in a day exceeds the threshold value. |
630 |
Stick Slip alerts when the valve shows stick and slip movement. |
631 |
Deviation + Alarm |
632 |
Deviation + alerts when there is a plus deviation between current travel (%) and input signal (%) . |
633 |
Deviation - Alarm |
634 |
Deviation - alerts when there is a minus deviation between current travel (%) and input signal (%). |
635 |
Valve Status 2 |
636 |
Temp High alerts when measured temperature exceeds high thresholds. |
637 |
Temp Low alerts when measured temperature falls below low thresholds. |
638 |
0% Tvl Error + alerts when there is upward deviation between current 0% travel angle and initial 0% travel angle. |
639 |
0% Tvl Error - alerts when there is downward deviation between current 0% travel angle and initial 0% travel angle. |
640 |
Travel Rate Count 1 |
641 |
Travel Rate Count 2 |
642 |
Travel Rate Count 3 |
643 |
Travel Rate Count 4 |
644 |
Travel Rate Count 5 |
645 |
Travel Rate Count 6 |
646 |
Travel Rate Count 7 |
647 |
Travel Rate Count 8 |
648 |
Travel Rate Count 9 |
649 |
Travel Rate Count 10 |
650 |
Travel Rate Count 11 |
651 |
Travel Rate Count 12 |
652 |
Travel Rate Count 13 |
653 |
Travel Rate Count 14 |
654 |
Travel Rate Count 15 |
655 |
Travel Rate Count 16 |
656 |
cmd172_dummy1 |
657 |
Transducer Unit |
658 |
8u |
659 |
|
660 |
The input current is too high. Please check the input value. |
661 |
The input current is too low. Please check the input value. |
662 |
Auto Setup |
663 |
"Auto Setup" will automatically configure/calibrate following items.
- Zero point (0% Travel Angle) & Span (100% Travel Angle)
- Actuator Size & Gland Packing Type
- Actuator Action
After Auto set up, please check calibration result.
You may be required to re-calibrate span so meet specific actuator design. |
664 |
Dummy Input Signal |
665 |
Dummy input signal applies dummy input signal to the positioner for the functional check. |
666 |
Dummy Drive Signal |
667 |
Dummy drive signal applies dummy drive signal to the positioner for the functional check. |
668 |
Save current settings |
669 |
"Save current settings" will save current setting data to the internal back up memory of the positioner. |
670 |
Load saved settings |
671 |
Configuration data is reset at the time of shipment. |
672 |
Change Actuator Size |
673 |
Actuator size parameter will be changed. |
674 |
Change Gland Packing Type |
675 |
Gland packing type parameter will be changed. |
676 |
Calibrate 4mA |
677 |
"Calibrate 4mA" will calibrate 4mA signal that the positioner recognizes to the standard 4mA signal or actual controller output. |
678 |
Calibrate 20mA |
679 |
"Calibrate 20mA" will calibrate 20mA signal that the positioner recognizes to the standard 20mA signal or actual controller output. |
680 |
Angle Adjustment |
681 |
Angle adjustment is the method to calibrate zero/span by designating correction angle to preset 0% or 100% travel angle. |
682 |
Manual Adjustment |
683 |
Manual adjustment is the method to calibrate zero/span by designating actual valve close or open position. |
684 |
Clear Stick Slip Count |
685 |
Stick slip count parameter will be cleared. |
686 |
Clear Max Tvl Speed |
687 |
Max tvl speed parameters will be cleared. |
688 |
Clear Travel Histogram |
689 |
Travel histogram parameters will be cleared. |
690 |
Change Mode |
691 |
Mode parameter will be changed. |
692 |
Update Stick Slip |
693 |
Stick slip parameters will be updated. |
694 |
Update Total Stroke |
695 |
Total stroke parameter will be updated. |
696 |
Update Cycle Count |
697 |
Cycle count parameter will be updated. |
698 |
Update Travel Histogram |
699 |
Travel histogram parameters will be updated. |
700 |
Update Shut-Off Count |
701 |
Shut-Off count parameter will be updated. |
702 |
Update Max Tvl Speed |
703 |
Max tvl speed parameters will be updated. |
704 |
Update |
705 |
Diagnostic parameters will be updated. |
706 |
Process Variables |
707 |
Device |
708 |
Diagnostics |
709 |
Setup |
710 |
Device Information |
711 |
Maintenance |
712 |
Review |
713 |
Positioner Diagnostic Status |
714 |
Valve Diagnostic Status |
715 |
Valve Diagnostic Information |
716 |
Basic Setup |
717 |
Input Range |
718 |
Zero/Span Adjustment |
719 |
Valve System |
720 |
Control Configuration |
721 |
Travel Cutoff |
722 |
ID |
723 |
Revisions |
724 |
Input Calibration |
725 |
Simulation |
726 |
Save/Load |
727 |
Critical Failures |
728 |
Device Status |
729 |
Stick Slip |
730 |
Travel Histogram |
731 |
0% Travel Error |
732 |
Max Travel Speed |
733 |
Deviation Alarm |
734 |
Temperature Alarm |
735 |
PID Parameters |
736 |
User-defined Data |
737 |
Travel Segmentation |
738 |
Monitoring |
739 |
Chart |
740 |
Update Diagnostic Parameters |
741 |
Displays Device Image |
742 |
Displays Device Status |
743 |
Dinamic Data Chart |
744 |
Common Tables |
745 |
Interoperable * |
746 |
Universal |
747 |
Common Practice |
748 |
Pressure Universal |
749 |
Pressure Common |
750 |
Menu |
751 |
Rosemount Magflow |
752 |
Rosemount Pressure |
753 |
Moore Products |
754 |
Siemens Pressure |
755 |
P2 Common |
756 |
PV |
757 |
Wireless |
758 |
Munge |
759 |
Analytical Oxygen/Combustion/Methane/CO |
760 |
Flow Totalizer - Rate Indicator |
761 |
Flow Variable Area |
762 |
Flow Coriolis Mass |
763 |
Flow Ultrasonic - Gas |
764 |
Flow Ultrasonic - Liquid |
765 |
Level Ultrasonic |
766 |
Level Radar - Microwave |
767 |
Pressure Absolute |
768 |
Level Capacitance |
769 |
Pressure Differential |
770 |
Level Hydrostatic |
771 |
Level |
772 |
Pressure Absolute/Relative |
773 |
Level Microwave |
774 |
Level Radar |
775 |
Level Density - Nuclear |
776 |
Flow Electromagnetic |
777 |
Flow Vortex |
778 |
Flow Magmeter - Rack Version |
779 |
Flow High Performance Magmeter |
780 |
Flow Mass |
781 |
Flow Ultrasonic |
782 |
Flow Magnetic |
783 |
Flow Magnetic - Custody Transfer |
784 |
Flow 2-wire Magnetic |
785 |
Flow Coriolis Mass - Custody Transfer |
786 |
Flow 2-wire Vortex |
787 |
Flow Thermal |
788 |
Temperature Head Mounted |
789 |
Temperature Compact |
790 |
Temperature DIN Rail Mounted |
791 |
Analytical pH |
792 |
Analytical Conductivity - Conductive |
793 |
Analytical Conductivity - Inductive |
794 |
Temperature Sensor |
795 |
Level Servo |
796 |
Temperature DIN Rail |
797 |
Analytical ORP |
798 |
Analytical pION |
799 |
Analytical IConc |
800 |
Analytical Electrode Conductivity |
801 |
Analytical Toroidal Conductivity |
802 |
Valve Positioner |
803 |
Valve Controller |
804 |
Pressure |
805 |
Pressure Multivariable |
806 |
Analytical pH/ORP |
807 |
Flow Coriolis |
808 |
Analytical Conductivity |
809 |
Valve Positioner/Pneumatic |
810 |
Valve Actuator - Electrical |
811 |
Temperature Dual Input |
812 |
Valve Actuator |
813 |
Analytical Corrosion |
814 |
Analytical Density - Nuclear |
815 |
Level Continuous Gamma |
816 |
Level Laser Ranging |
817 |
Pressure Safety |
818 |
Flow Vortex/Swirl |
819 |
Flow |
820 |
Analytical 4 Electrode Conductivity |
821 |
Analytical 2 Electrode Conductivity |
822 |
Analytical Troidal Conductivity |
823 |
Analytical pH/ORP/pIon/Ion Conc |
824 |
Analytical Oxygen |
825 |
Pressure P, dP + Multivariable |
826 |
Temperature 2-wire |
827 |
Pressure w/ PID |
828 |
Pressure Saturated Steam |
829 |
Analytical Density - Gamma Ray |
830 |
Level Gamma Ray |
831 |
Analytical Weight - Gamma Ray |
832 |
Level w/ Density - Gamma Ray |
833 |
Analytical Motorized Density |
834 |
Flow Multivariable Mass |
835 |
Temperature Multivariable |
836 |
Specialty HART-to-Analog Signal Conv |
837 |
Flow dP |
838 |
Pressure Low Power |
839 |
Pressure Certified SIL2 |
840 |
Interoperable |
841 |
Analytical Density |
842 |
Valve Positioner/Electropneumatic |
843 |
Flow Magnetic Inductive |
844 |
Analytical |
845 |
Analytical Opacity Monitor |
846 |
Analytical Oxygen/Combustion |
847 |
Analytical 2-wire Conductivity |
848 |
Analytical 2-wire Conductivity w/ pure H20 |
849 |
Analytical 2-wire Conductivity w/ % conc |
850 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
851 |
Analytical 2-wire pH/ORP |
852 |
Analytical 2-wire Contacting/Toroidal |
853 |
Analytical Oxygen - High Temperature |
854 |
Analytical Conductivity w/ % conc |
855 |
Analytical pH/ORP/ISE |
856 |
Analytical Amperometric Analyzer |
857 |
Analytical Dual Input Analyzer |
858 |
Pressure Pressure/Level |
859 |
Analytical Consistency |
860 |
Analytical Microwave-Pulp Consistency |
861 |
Analytical Microwave Consistency |
862 |
Valve Digital Positioner |
863 |
Valve Smart Valve Positioner |
864 |
Temperature Differential |
865 |
Analytical Dissolved Oxygen |
866 |
Analytical pH Controller |
867 |
Analytical Conductivity/Resistivity Controller |
868 |
Analytical Conductivity/Resistivity |
869 |
Level Displacement |
870 |
Temperature w/ PID |
871 |
Valve Universal Positioner |
872 |
Level Radar - Reflex |
873 |
Pressure Gauge |
874 |
Pressure Sealed Gauge |
875 |
Valve Digital Positioner w/ PID |
876 |
Valve Intelligent Positioner |
877 |
Analytical Gas Detector |
878 |
Analytical Infrared Gas Detector |
879 |
Analytical Electrochemical Gas Detector |
880 |
Analytical Measuring Instruments |
881 |
Level Magnostrictive |
882 |
Valve On/Off Valve Controller |
883 |
Level Radar - Pulse |
884 |
Level Continuous Capactive |
885 |
Valve Damper Actuator |
886 |
Valve Electric Damper Actuator |
887 |
Flow Electronic |
888 |
Flow Vortex - Multiparameter Mass |
889 |
Analytical UV Flame Detector |
890 |
Analytical UVIR Flame Detector |
891 |
Analytical IR Flame Detector |
892 |
Analytical Fire Detector |
893 |
Analytical Gas Detector Display Interface |
894 |
Analytical Toxic Gas Detector |
895 |
Analytical Flame Detector |
896 |
Level Nuclear |
897 |
Analytical Microwave |
898 |
Analytical Density - Radiometric |
899 |
Level Radiometric |
900 |
Analytical Gas/Steam |
901 |
Level Nucleonic |
902 |
Analytical Blade Consistency |
903 |
Analytical Rotary Consistency |
904 |
Pressure Absolute/Differential |
905 |
Positioner |
906 |
Analytical Combustible Gas Detector |
907 |
Analytical Point Infrared Gas Detector |
908 |
Analytical Multi-Detector Monitor System |
909 |
Valve Positioner/Electro-hydraulic |
910 |
Valve Monitor |
911 |
Enable on token-passing data link layer only |
912 |
Enable on TDMA data link layer only |
913 |
Enable on both TDMA and token-passing data link layer |
914 |
WirelessHART Device |
915 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
916 |
Primary |
917 |
Primary Analog Channel |
918 |
Secondary |
919 |
Secondary Analog Channel |
920 |
Tertiary |
921 |
Tertiary Analog Channel |
922 |
Quaternary |
923 |
Quaternary Analog Channel |
924 |
Quinary |
925 |
Quinary Analog Channel |
926 |
Critical Power Failure |
927 |
Lock all |
928 |
Trim not supported |
929 |
Configuration cannot be changed |
930 |
Locked by gateway |
931 |
Analog Input Channel |
932 |
Analog Output Channel |
933 |
Secondary Analog Channel Saturated |
934 |
Tertiary Analog Channel Saturated |
935 |
Quaternary Analog Channel Saturated |
936 |
Quinary Analog Channel Saturated |
937 |
Secondary Analog Channel Fixed |
938 |
Tertiary Analog Channel Fixed |
939 |
Quaternary Analog Channel Fixed |
940 |
Quinary Analog Channel Fixed |
941 |
Simulation active |
942 |
The device is in simulation mode and the level output is not representative of the process. |
943 |
Non-Volatile memory failure |
944 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
945 |
Volatile memory error |
946 |
The RAM memory check is invalid or maybe corrupt |
947 |
Watchdog reset executed |
948 |
A watchdog reset has been performed |
949 |
Voltage conditions out of range |
950 |
A voltage condition is outside its allowable range |
951 |
Environmental conditions out of range |
952 |
An internal or environmental condition is beyond acceptable limits. |
953 |
Electronic failure |
954 |
A hardware problem not related to the sensor has been detected. |
955 |
Subdevice list changed |
956 |
Duplicate master detected |
957 |
Capacity Denied |
958 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
959 |
Bandwidth allocation pending |
960 |
Block transfer pending |
961 |
Continuous |
962 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
963 |
Window |
964 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
965 |
Rising |
966 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
967 |
Falling |
968 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
969 |
On-change |
970 |
The Burst Message is triggered when any value in the message changes. |
971 |
Battery life |
972 |
Percent range |
973 |
Loop current |
974 |
Primary variable |
975 |
Secondary variable |
976 |
Tertiary variable |
977 |
Quaternary variable |
978 |
Off |
979 |
Enable event notification on token-passing data link layer |
980 |
Enable event notification on TDMA data link layer |
981 |
Enable event notification on TDMA and token-passing data link layer |
982 |
Configuration changed event pending |
983 |
Device status event pending |
984 |
More status available event pending |
985 |
Disable |
986 |
Enable single data point trending |
987 |
Enable filtered trending |
988 |
The sample is filtered using a time constant equal to one-third the trend sample period |
989 |
Enable average trending |
990 |
The value obtained by dividing the sum of all samples in the period by the total number of samples |
991 |
Read receive time |
992 |
Write date and time |
993 |
Non-Volatile Clock |
994 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
995 |
Clock Uninitialized |
996 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
997 |
Line Power |
998 |
Device is powered via a hardwired connection to a plant power source. |
999 |
Battery Power |
1000 |
Device operates solely of its (internal) battery. |
1001 |
Recharg.B./Power Sc. |
1002 |
Rechargeable battery power or power scavenging. The device has a short-term supply of energy (must be at least one hour) that is continuously being replenished. The device's power is being replenished by harvesting and converting energy from the environment surrounding the device (e.g. solar, vibration, heat). |
1003 |
Idle |
1004 |
Active search |
1005 |
Looking for neighbors. |
1006 |
Negotiating |
1007 |
Quarantined |
1008 |
Operational |
1009 |
Suspended |
1010 |
Deep sleep |
1011 |
Ultra-low power |
1012 |
Wireless Signal Found |
1013 |
Network packets have been recognized |
1014 |
Wireless Signal Identified |
1015 |
Wireless Time Synchronized |
1016 |
WirelessHart Signal Identified |
1017 |
Network Admission Requested |
1018 |
Set on transmission of first join request |
1019 |
Join Retrying |
1020 |
Set after the first join request retry (i.e. when number of join requests > 2). Cleared when device is authenticated or when Active Search started. |
1021 |
Join Failed |
1022 |
Set on transition from Active Search mode to Deep Sleep mode. Cleared on transition from Deep Sleep to Active Search. |
1023 |
Network Security Clearance Granted |
1024 |
Network Manager Session Established |
1025 |
Network Joined |
1026 |
Network Joined. Normal superframe and links obtained. |
1027 |
Network Bandwidth Requested |
1028 |
Negotiating Network Properties. Gateway session obtained. |
1029 |
Join Complete |
1030 |
Normal operating mode. |
1031 |
None |
1032 |
No restrictions |
1033 |
SI Only |
1034 |
Restricted to SI Unit codes only |
1035 |
Open - accept all devices |
1036 |
Use Whitelist for access |
1037 |
Use Blacklist |
1038 |
Use Whitelist and Blacklist |
1039 |
Lockdown - disable join links |
1040 |
Process automation device |
1041 |
Discrete device |
1042 |
Hybrid:Process automation+discrete |
1043 |
I/O System |
1044 |
WirelessHART Process automation device |
1045 |
WirelessHART Discrete device |
1046 |
WirelessHART Process automation+discrete |
1047 |
WirelessHART Gateway |
1048 |
WirelessHART Access point |
1049 |
WirelessHART Process adapter |
1050 |
WirelessHART Discrete adapter |
1051 |
WirelessHART enabled handheld/portable maintenance tool |
1052 |
Don't attempt to join |
1053 |
Join now |
1054 |
Attempt to join immediately on powerup or reset |
1055 |
US |
1056 |
United States of America |
1057 |
JP |
1058 |
Japan |
1059 |
DE |
1060 |
Germany |
1061 |
FR |
1062 |
France |
1063 |
ES |
1064 |
Spain |
1065 |
RU |
1066 |
Russian Federation |
1067 |
CN |
1068 |
People's Republic of China |
1069 |
Nominal |
1070 |
Device Power Status is nominal |
1071 |
Low |
1072 |
Device Power Status is low |
1073 |
Critically Low |
1074 |
Device Power Status is critically low |
1075 |
Recharging - Low |
1076 |
Recharging - High |
1077 |
Secondary Master |
1078 |
Primary Master |
1079 |
PV Analog Channel Saturated |
1080 |
PV Analog Channel Fixed |
1081 |
Device Profile |
1082 |
Device Diagnostic Status 0 |
1083 |
Device Diagnostic Status 1 |
1084 |
I/O and Subdevice Status |
1085 |
WirelessHART Status |
1086 |
Time Set Option |
1087 |
Real Time Clock Flags |
1088 |
Country |
1089 |
Country of intended device installation |
1090 |
SI Unit Control |
1091 |
Indicates if device should only display SI unit codes |
1092 |
Burst Trigger Units |
1093 |
Burst Trigger Class |
1094 |
Wired HART Enabled |
1095 |
Enabled on Wired HART device connection only |
1096 |
Wireless HART Enabled |
1097 |
Enabled on WirelessHART device connection only |
1098 |
Both Wired and WirelessHart Enabled |
1099 |
Enabled on both Wired and WirelessHART connections |
1100 |
Burst Msg Trigger Mode |
1101 |
Event Status |
1102 |
Event Notification Control |
1103 |
Operate mode Mask |
1104 |
Not Defined |
1105 |
Power Source |
1106 |
Power source of the device |
1107 |
Wireless Mode |
1108 |
Join Status |
1109 |
The current location in the joining sequence of operations. |
1110 |
Network Access Mode |
1111 |
Join Mode |
1112 |
Power Status |
1113 |
Power status of the device |
1114 |
Master Mode |
1115 |
This sets the I/O System's Data Link Layer operation on all channels as either primary or secondary master mode. |
1116 |
Trend Units |
1117 |
Trend Device Variable Unit Code |
1118 |
Trend Classification |
1119 |
Trend Device Variable Classification |
1120 |
Trend Control |
1121 |
Device Status Mask |
1122 |
Ext dev status Mask |
1123 |
Device Diagnostic Status 0 Mask |
1124 |
Device Diagnostic Status 1 Mask |
1125 |
Device Diagnostic Status 2 Mask |
1126 |
Device Diagnostic Status 3 Mask |
1127 |
AO saturated Mask |
1128 |
AO fixed Mask |
1129 |
Latched Device Status |
1130 |
Latched Ext dev status |
1131 |
Latched Operate Mode |
1132 |
Latched Device Diagnostic Status 0 |
1133 |
Latched Device Diagnostic Status 1 |
1134 |
Latched Device Diagnostic Status 2 |
1135 |
Latched Device Diagnostic Status 3 |
1136 |
Latched AO saturated |
1137 |
Latched AO fixed |
1138 |
Wireless Module Device Type |
1139 |
Device type of the Wireless Radio |
1140 |
Wireless Module Manufacturer ID |
1141 |
Manufacturer of the Wireless Radio contained in this device |
1142 |
Subdevice Device Type |
1143 |
Device type of the subdevice attached to this system. |
1144 |
Subdevice Manufacturer Id |
1145 |
Manufacturer of the subdevice attached to this system. |
1146 |
8.3f |
1147 |
Device Variable |
1148 |
Aborting method due to last error |
1149 |
Caution!
SVP is now in "In service" mode.
Please change the device mode to "Out of service". |
1150 |
Attention!
Please ensure safety of personnel and process operation before Auto setup. |
1151 |
You are going to initiate Auto setup.
Proceed? |
1152 |
Auto setup is being carried out.
Please wait a while. |
1153 |
Auto setup is completed.
Please verify accurate operation by varying input signal. |
1154 |
Auto setup is not completed.
Try Auto setup again or configure SVP manually. |
1155 |
Caution!
Please ensure safety of personnel and process operation before dummy signal operation. |
1156 |
Dummy Input Signal:
|
1157 |
0%;50%;100%;Other;Clear;Exit |
1158 |
Dummy Input Signal:
Enter dummy input signal value.
|
1159 |
Dummy Drive Signal:
|
1160 |
Dummy Drive Signal:
Enter dummy drive signal value.
|
1161 |
Caution!
Save current settings will erase factory setting data inside SVP. |
1162 |
You are going to initiate Save current settings.
Proceed? |
1163 |
Save current settings was completed. |
1164 |
Caution!
Load saved settings will erase current config data. |
1165 |
You are going to initiate Load saved settings.
Proceed? |
1166 |
Load saved settings is completed.
To update to the latest data, PLEASE RESTART THE HOST APPLICATION.
After that please reconfigure the SVP with Auto setup. |
1167 |
Actuator Size
Param0 |
1168 |
Param1;Param2;Param3;Param4;Param5;Param6;Param7;Param8;Param9;ParamA;ParamB;ParamC;Param0 |
1169 |
Actuator Size
Param1 |
1170 |
Actuator Size
ParamA |
1171 |
Actuator Size
ParamB |
1172 |
Actuator Size
ParamC |
1173 |
Actuator Size
Param2 |
1174 |
Actuator Size
Param3 |
1175 |
Actuator Size
Param4 |
1176 |
Actuator Size
Param5 |
1177 |
Actuator Size
Param6 |
1178 |
Actuator Size
Param7 |
1179 |
Actuator Size
Param8 |
1180 |
Actuator Size
Param9 |
1181 |
Actuator Size
Invalid |
1182 |
Actuator Size:Param0
Gland Packing Type
Not applied |
1183 |
Actuator Size:Param1
Gland Packing Type
Heavy |
1184 |
Heavy;Medium;Light |
1185 |
Actuator Size:Param1
Gland Packing Type
Medium |
1186 |
Actuator Size:Param1
Gland Packing Type
Light |
1187 |
Actuator Size:ParamA
Gland Packing Type
Not applied |
1188 |
Actuator Size:ParamB
Gland Packing Type
Not applied |
1189 |
Actuator Size:ParamC
Gland Packing Type
Not applied |
1190 |
Actuator Size:Param2
Gland Packing Type
Heavy |
1191 |
Actuator Size:Param2
Gland Packing Type
Medium |
1192 |
Actuator Size:Param2
Gland Packing Type
Light |
1193 |
Actuator Size:Param3
Gland Packing Type
Heavy |
1194 |
Actuator Size:Param3
Gland Packing Type
Medium |
1195 |
Actuator Size:Param3
Gland Packing Type
Light |
1196 |
Actuator Size:Param4
Gland Packing Type
Heavy |
1197 |
Actuator Size:Param4
Gland Packing Type
Medium |
1198 |
Actuator Size:Param4
Gland Packing Type
Light |
1199 |
Actuator Size:Param5
Gland Packing Type
Heavy |
1200 |
Actuator Size:Param5
Gland Packing Type
Medium |
1201 |
Actuator Size:Param5
Gland Packing Type
Light |
1202 |
Actuator Size:Param6
Gland Packing Type
Heavy |
1203 |
Actuator Size:Param6
Gland Packing Type
Medium |
1204 |
Actuator Size:Param6
Gland Packing Type
Light |
1205 |
Actuator Size:Param7
Gland Packing Type
Heavy |
1206 |
Actuator Size:Param7
Gland Packing Type
Medium |
1207 |
Actuator Size:Param7
Gland Packing Type
Light |
1208 |
Actuator Size:Param8
Gland Packing Type
Heavy |
1209 |
Actuator Size:Param8
Gland Packing Type
Medium |
1210 |
Actuator Size:Param8
Gland Packing Type
Light |
1211 |
Actuator Size:Param9
Gland Packing Type
Heavy |
1212 |
Actuator Size:Param9
Gland Packing Type
Medium |
1213 |
Actuator Size:Param9
Gland Packing Type
Light |
1214 |
Actuator Size:Invalid
Gland Packing Type
Invalid |
1215 |
4mA calibration:
Set current to 4mA.
|
1216 |
Calibrate this current to 4mA.
Proceed?
%[.2f]{fval} mA |
1217 |
4mA calibration is being carried out.
Please wait a while. |
1218 |
4mA calibrated.
%[.2f]{fval} mA |
1219 |
20mA calibration:
Set current to 20mA.
|
1220 |
Calibrate this current to 20mA.
Proceed?
%[.2f]{fval} mA |
1221 |
20mA calibration is being carried out.
Please wait a while. |
1222 |
20mA calibrated.
%[.2f]{fval} mA |
1223 |
Zero/Span adjustment:
|
1224 |
Zero;Span;Exit |
1225 |
Zero adjustment:
Set current to LRV(Shut).
|
1226 |
Please set travel cutoff low less than 0%. |
1227 |
Travel Cutoff Low
|
1228 |
Zero adjustment:
|
1229 |
Exit;Increment / 0.006;Decrement / 0.006;Increment / 0.03;Decrement / 0.03;Increment / 0.3;Decrement / 0.3;Increment / 3;Decrement / 3 |
1230 |
Please reset travel cutoff low more than 0%.
0.5 % is recommended. |
1231 |
Span adjustment:
Set current to URV(Open).
|
1232 |
Please set travel cutoff high more than 100%. |
1233 |
Travel Cutoff High
|
1234 |
Span adjustment:
|
1235 |
Please reset travel cutoff high less than 100%.
If necessary. |
1236 |
Zero adjustment:
Set valve opening at fully closed position manually.
|
1237 |
You are going to set this opening as zero point.
Proceed?
%[.2f]{fval} % |
1238 |
Zero adjustment is completed. |
1239 |
Span adjustment:
Set valve opening at fully open position manually.
|
1240 |
You are going to set this opening as span point.
Proceed?
%[.2f]{fval} % |
1241 |
Span adjustment is completed. |
1242 |
You are going to clear the parameter of "Stick Slip Count".
Proceed? |
1243 |
You are going to clear the parameter of "Max Tvl Speed".
Proceed? |
1244 |
You are going to clear the parameters of "Travel Histogram".
Proceed? |
1245 |
Mode
Out of service |
1246 |
Out of service;In service |
1247 |
Mode
In service |
1248 |
After the mode parameter is changed, some host applications fail to update the display properly.
In that case, CLOSE THE WINDOW AND OPEN IT AGAIN. |
1249 |
You are going to update the parameters of "Stick Slip X", "Stick Slip Y" and "Stick Slip Count".
Proceed? |
1250 |
You are going to update the parameter of "Total Stroke".
Proceed? |
1251 |
You are going to update the parameter of "Cycle Count".
Proceed? |
1252 |
You are going to update the parameters of "Travel Histogram".
Proceed? |
1253 |
You are going to update the parameter of "Shut-Off Count".
Proceed? |
1254 |
You are going to update the parameters of "Max Tvl Speed".
Proceed? |
1255 |
You are going to update the diagnostic parameters.
Proceed? |