0 |
MagneW |
1 |
Yamatake Corporation |
2 |
.1f |
3 |
EXCIT COIL FAULT |
4 |
A.C. POWER LOSS |
5 |
NVM FAULT |
6 |
RAM FAULT |
7 |
ROM FAULT |
8 |
A/D FAULT |
9 |
BAD CONFIG DATA |
10 |
DI/DO = SATATUS |
11 |
FIXED PULSE MODE |
12 |
OUTPUT MODE |
13 |
LOCAL MODE |
14 |
CORRECTS RESET |
15 |
EXCIT CHECK MODE |
16 |
EMPTY PIPE |
17 |
EXT ZERO ACTIVE |
18 |
TYPE-DIA ERROR |
19 |
HIGH<LOW ERROR |
20 |
SPAN OVER ERROR |
21 |
PLS WEIGHT ERROR |
22 |
PLS WIDTH ERROR |
23 |
HYSTERESIS ERROR |
24 |
Flow Sensor- Hardware that measures flow rate. |
25 |
Pulse output- scaled frequency output from 0-1000 Hz, linear with input. |
26 |
Gross Total- Non-resettable totalizer. |
27 |
Net Total Value- Resettable totalizer. |
28 |
Reverse Total- Non-resettable reverse totalizer. |
29 |
write variables |
30 |
PULSE SPAN DUTY OVER 70% |
31 |
Gross Total- Non-resettable totalizer |
32 |
Net Total Value- Resettable totalizer |
33 |
Reverse Total - Non-resettable reverse totalizer |
34 |
Device Status |
35 |
AO |
36 |
5.1f |
37 |
.5f |
38 |
7.5f |
39 |
Puls out unit |
40 |
m3/P |
41 |
l/P |
42 |
cm3/P |
43 |
t/P |
44 |
kg/P |
45 |
g/P |
46 |
B/P |
47 |
kG/P |
48 |
G/P |
49 |
mG/P |
50 |
lb/P |
51 |
m3/d |
52 |
m3/h |
53 |
m3/m |
54 |
m3/s |
55 |
l/d |
56 |
l/h |
57 |
l/m |
58 |
l/s |
59 |
cm3/d |
60 |
cm3/h |
61 |
cm3/m |
62 |
cm3/s |
63 |
t/d |
64 |
t/h |
65 |
t/m |
66 |
t/s |
67 |
kg/d |
68 |
kg/h |
69 |
kg/m |
70 |
kg/s |
71 |
g/d |
72 |
g/h |
73 |
g/m |
74 |
g/s |
75 |
BPD |
76 |
BPH |
77 |
BPM |
78 |
BPS |
79 |
kGPD |
80 |
kGPH |
81 |
kGPM |
82 |
kGPS |
83 |
GPD |
84 |
GPH |
85 |
GPM |
86 |
GPS |
87 |
mGPD |
88 |
mGPH |
89 |
mGPM |
90 |
mGPS |
91 |
lb/d |
92 |
lb/h |
93 |
lb/m |
94 |
lb/s |
95 |
ms |
96 |
Pulse Width- Width of the frequency output pulse on frequency output number 'X'. |
97 |
.2f |
98 |
6.2f |
99 |
Low Flow Cutoff- Set point that determines when the process variable will indicate 0 rather than some nominally small value. |
100 |
OFF |
101 |
0 % |
102 |
1 % |
103 |
2 % |
104 |
3 % |
105 |
4 % |
106 |
5 % |
107 |
6 % |
108 |
7 % |
109 |
8 % |
110 |
9 % |
111 |
10 % |
112 |
Flow tube size |
113 |
Flow tube size- Nominal inside diameter of the pipe adjacent to the sensor. |
114 |
2.5 A |
115 |
5 A |
116 |
10 A |
117 |
15 A |
118 |
20 A |
119 |
25 A |
120 |
32 A |
121 |
40 A |
122 |
50 A |
123 |
65 A |
124 |
80 A |
125 |
100 A |
126 |
125 A |
127 |
150 A |
128 |
200 A |
129 |
250 A |
130 |
300 A |
131 |
350 A |
132 |
400 A |
133 |
450 A |
134 |
500 A |
135 |
600 A |
136 |
700 A |
137 |
800 A |
138 |
900 A |
139 |
1000 A |
140 |
1100 A |
141 |
1200 A |
142 |
1300 A |
143 |
1350 A |
144 |
1400 A |
145 |
1500 A |
146 |
1600 A |
147 |
1800 A |
148 |
2000 A |
149 |
2200 A |
150 |
2400 A |
151 |
2600 A |
152 |
EX_factor |
153 |
Flow Tube Calibration Number- This number is uniquely associated with the flow tube, and is used to compensate for gain and zero shifts associated with the specific tube. The calibration number is calculated at the factory and is stamped on the flow tube. |
154 |
Puls outp test |
155 |
Pulse Output Test Value- Scaled frequency output from 0-1000 Hz, linear with input. |
156 |
% |
157 |
Totalizer Control Code- Controls the operation of all available totalizers. |
158 |
10d |
159 |
si_only |
160 |
An SI-Only device |
161 |
Not an SI-Only device |
162 |
FMU860 |
163 |
DT |
164 |
DVC |
165 |
FCX |
166 |
AS800 |
167 |
340T |
168 |
340C |
169 |
344 |
170 |
Siemens Micro K |
171 |
SITRANS L |
172 |
SIPAN PH |
173 |
SITRANS P |
174 |
75SMT |
175 |
UNIDELTA |
176 |
8320 |
177 |
SX5100 |
178 |
TSV175 |
179 |
DMU |
180 |
3780 |
181 |
BM70 |
182 |
8u |
183 |
Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. |
184 |
?? |
185 |
Pulse Scaling Factor- Magnitude of process variable per pulse. |
186 |
4.2f |
187 |
Puls outp |
188 |
Pulse Output Value- scaled frequency output from 0-1000 Hz, linear with input. |
189 |
Net Total Value- Resettable totalizer value. Counts frequency output pulses while total control is turned on. |
190 |
Gross Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on. This value will be reset to 0 when the pulse scaling, line size, or units are changed. |
191 |
Reverse Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on and flow is in the reverse direction. This value will be reset to 0 when the pulse scaling, line size, or units are changed. |
192 |
7d |
193 |
Coil Drive Frequency- Frequency that the coils operate at. |
194 |
Hz |
195 |
6Hz |
196 |
30Hz |
197 |
gross_total_units |
198 |
Pulse output units- Engineering units that the frequency and totalizer outputs will be displayed with |
199 |
Net Total Value- Counts frequency output pulses while total control is turned on. |
200 |
Pulse Output- Scaled frequency output from 0-1000 Hz, linear with input. |
201 |
Pulse output value- scaled frequency output from 0-1000 Hz, linear with input |
202 |
Totalizer units |
203 |
Gross Total Value- Counts frequency output pulses while total control is turned on. This value will be reset to 0 when the pulse scaling, line size , or units are changed |
204 |
Reverse Total Value- Counts frequency output pulses while total control is turned on and flow is in the reverse direction. This value will be reset to 0 when the pulse scaling, line size, or units are changed |
205 |
Totalizer Variable- Counts pulses from frequency output and scales the value based on the pulse output scaling and units. |
206 |
Puls outp loop test |
207 |
About to enter fixed freq. mode test |
208 |
Set Pulse Output value |
209 |
Select value;exit |
210 |
Enter Pulse Output: |
211 |
The previous error was seen while attempting to set the Pulse Frequency to a fixed value |
212 |
Pulse Output Now Set to %0 |
213 |
Exiting pulse output test |
214 |
Warning Device may have Pulse frequency at a fixed value |
215 |
About to enter auto zero |
216 |
The previous error was seen while trying to initiate auto zero |
217 |
Waiting for auto zero to complete. |
218 |
Device failure. Device may be stuck in Auto Zero. |
219 |
Device failure in Auto Zero. |
220 |
The previous error was seen while trying to burn eeprom |
221 |
Auto zero passed |
222 |
Status |
223 |
Sensor |
224 |
Sensor Config |
225 |
Sensor Info |
226 |
Totalizer |
227 |
Puls outp config |
228 |
Device Info |
229 |
Revision #'s |