0 |
APT3200 |
1 |
Autrol(Duon) |
2 |
Duon System |
3 |
External EEPROM write fail |
4 |
Flash Access violation |
5 |
Flash memory write fail |
6 |
Pressure PV Data Over limit |
7 |
Pressure count Over limit |
8 |
Sensor error |
9 |
ADC Counter limit over |
10 |
ADC setting value changed |
11 |
ADC DRDY timeout |
12 |
Oscillator Fault |
13 |
Calibration data error |
14 |
Thermometer error |
15 |
External EEPROM read fail |
16 |
Program memory CRC error |
17 |
.3f |
18 |
Pres Dev fmly |
19 |
Pres Class |
20 |
Pres PDQ |
21 |
Pres LS |
22 |
Pres Fmly stat |
23 |
8.3f |
24 |
Pressure Update Period |
25 |
|
26 |
7d |
27 |
Pres Lower trim |
28 |
Pres Upper trim |
29 |
Pres Trim support |
30 |
Pres Min lower trim |
31 |
Pres Max lower trim |
32 |
Pres Min upper trim |
33 |
Pres Max upper trim |
34 |
Pres Min trim diff |
35 |
Simulate |
36 |
Update Period |
37 |
Snsr temp unit |
38 |
Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. |
39 |
Temp Class |
40 |
Temp PDQ |
41 |
Temp LS |
42 |
Temp Dev Stat |
43 |
Temp USL |
44 |
Temp LSL |
45 |
Temp min span |
46 |
Temp Update Period |
47 |
Temp snsr s/n |
48 |
Secondary Variable - Temperature Compensation |
49 |
Pressure |
50 |
Temperature |
51 |
Select trim mode |
52 |
Trim Mode |
53 |
Point |
54 |
Upper |
55 |
Lower |
56 |
Cleared |
57 |
Current PV value |
58 |
Current trim value |
59 |
8.4f |
60 |
Change current value to apply value for trim |
61 |
Apply trim value |
62 |
Invalid Unit Code |
63 |
Device transmitter variable code |
64 |
Xmtr Variable |
65 |
Pri-Var |
66 |
Sec-Var |
67 |
Tri-Var |
68 |
4th-Var |
69 |
Pressure Tranmitter Sensor Type Code |
70 |
Selected Sensor Type |
71 |
GP 2 |
72 |
GP 2-1 |
73 |
GP 2-2 |
74 |
GP 3 |
75 |
GP 4 |
76 |
GP 4-1 |
77 |
GP 4-2 |
78 |
GP 4-3 |
79 |
GP 4-4 |
80 |
GV 4 |
81 |
GV 4-1 |
82 |
GV 4-2 |
83 |
GV 4-3 |
84 |
GV 4-4 |
85 |
GP 5 |
86 |
GP 5-1 |
87 |
GV 5 |
88 |
GP 6 |
89 |
GP 6-1 |
90 |
GV 6 |
91 |
GV 6-1 |
92 |
GP 7 |
93 |
GV 7 |
94 |
GP 8 |
95 |
GV 8 |
96 |
GP 9 |
97 |
GV 9 |
98 |
AP 4 |
99 |
AP 4-1 |
100 |
AP 4-2 |
101 |
AP 4-3 |
102 |
AP 4-4 |
103 |
AP 5 |
104 |
AP 5-1 |
105 |
AP 6 |
106 |
#G6 |
107 |
#G4 |
108 |
#G5 |
109 |
#G7 |
110 |
#A4 |
111 |
#A5 |
112 |
#A6 |
113 |
#SG0 |
114 |
#SG1 |
115 |
#SG2 |
116 |
#SG3 |
117 |
#SG4 |
118 |
#SA5 |
119 |
#SA6 |
120 |
#SA7 |
121 |
#SG8 |
122 |
#SG9 |
123 |
#SG10 |
124 |
#SG11 |
125 |
Invalid Transmitter Variable Code |
126 |
LCD mode |
127 |
LCD Display Mode |
128 |
Normal> All Values |
129 |
Normal> PV Only |
130 |
Normal> % Only |
131 |
Normal> mA Only |
132 |
Eng> All Values |
133 |
Eng> PV Only |
134 |
Engr. Xfer Fnctn |
135 |
Linear |
136 |
Sqar Root |
137 |
Decimal Place |
138 |
Auto |
139 |
#.#### (1-4) |
140 |
##.### (2-3) |
141 |
###.## (3-2) |
142 |
####.# (4-1) |
143 |
#####. (5-0) |
144 |
Update Failure |
145 |
Engr. Range Unit |
146 |
User |
147 |
User Defined Unit |
148 |
Engr. LRV |
149 |
Engr. URV |
150 |
User Defined unit |
151 |
Change current PV to zero adjustmet value |
152 |
Adjust value |
153 |
Select Zero Adjust mode |
154 |
Adjust Mode |
155 |
Zero Adj. |
156 |
Cut-Off Value |
157 |
5.2f |
158 |
Cut-OFF Mode |
159 |
Linear |
160 |
Zero |
161 |
Two Point Trim |
162 |
Adjust Trim |
163 |
Cut PV |
164 |
Eng. Unit Change |
165 |
More Status Clear |
166 |
Temp Unit |
167 |
Pressure Unit |
168 |
Volumetric flow Unit |
169 |
Velocity Unit |
170 |
Length Unit |
171 |
Time Unit |
172 |
Mass & Mass Flow |
173 |
Mass per volume |
174 |
Autrol.Pressure |
175 |
Device settings |
176 |
Diagnostics |
177 |
Maintenance |
178 |
Offline |
179 |
Temperature sensor |
180 |
Concentration sensor |
181 |
Operate |
182 |
Autrol Setup |
183 |
LCD output |
184 |
Dynamic Variables |
185 |
Device Status |
186 |
PV Analog Channel Saturated |
187 |
PV Analog Channel Fixed |
188 |
Wireless |
189 |
WirelessHART Device |
190 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
191 |
Primary |
192 |
Primary Analog Channel |
193 |
Secondary |
194 |
Secondary Analog Channel |
195 |
Tertiary |
196 |
Tertiary Analog Channel |
197 |
Quaternary |
198 |
Quaternary Analog Channel |
199 |
Quinary |
200 |
Quinary Analog Channel |
201 |
Critical Power Failure |
202 |
Lock all |
203 |
Trim not supported |
204 |
Configuration cannot be changed |
205 |
Locked by gateway |
206 |
Analog Input Channel |
207 |
Analog Output Channel |
208 |
Secondary Analog Channel Saturated |
209 |
Tertiary Analog Channel Saturated |
210 |
Quaternary Analog Channel Saturated |
211 |
Quinary Analog Channel Saturated |
212 |
Secondary Analog Channel Fixed |
213 |
Tertiary Analog Channel Fixed |
214 |
Quaternary Analog Channel Fixed |
215 |
Quinary Analog Channel Fixed |
216 |
Simulation active |
217 |
The device is in simulation mode and the level output is not representative of the process. |
218 |
Non-Volatile memory failure |
219 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
220 |
Volatile memory error |
221 |
The RAM memory check is invalid or maybe corrupt |
222 |
Watchdog reset executed |
223 |
A watchdog reset has been performed |
224 |
Voltage conditions out of range |
225 |
A voltage condition is outside its allowable range |
226 |
Environmental conditions out of range |
227 |
An internal or environmental condition is beyond acceptable limits. |
228 |
Electronic failure |
229 |
A hardware problem not related to the sensor has been detected. |
230 |
Subdevice list changed |
231 |
Duplicate master detected |
232 |
Capacity Denied |
233 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
234 |
Bandwidth allocation pending |
235 |
Block transfer pending |
236 |
Battery life |
237 |
Percent range |
238 |
Loop current |
239 |
Primary variable |
240 |
Secondary variable |
241 |
Tertiary variable |
242 |
Quaternary variable |
243 |
Read receive time |
244 |
Write date and time |
245 |
Non-Volatile Clock |
246 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
247 |
Clock Uninitialized |
248 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
249 |
None |
250 |
No restrictions |
251 |
SI Only |
252 |
Restricted to SI Unit codes only |
253 |
Process automation device |
254 |
Discrete device |
255 |
Hybrid:Process automation+discrete |
256 |
I/O System |
257 |
WirelessHART Process automation device |
258 |
WirelessHART Discrete device |
259 |
WirelessHART Process automation+discrete |
260 |
WirelessHART Gateway |
261 |
WirelessHART Access point |
262 |
WirelessHART Process adapter |
263 |
WirelessHART Discrete adapter |
264 |
WirelessHART enabled handheld/portable maintenance tool |
265 |
Device Profile |
266 |
US |
267 |
United States of America |
268 |
JP |
269 |
Japan |
270 |
DE |
271 |
Germany |
272 |
FR |
273 |
France |
274 |
ES |
275 |
Spain |
276 |
RU |
277 |
Russian Federation |
278 |
CN |
279 |
People's Republic of China |
280 |
Secondary Master |
281 |
Primary Master |
282 |
Device Diagnostic Status 0 |
283 |
Device Diagnostic Status 1 |
284 |
I/O and Subdevice Status |
285 |
WirelessHART Status |
286 |
Time Set Option |
287 |
Real Time Clock Flags |
288 |
Country |
289 |
Country of intended device installation |
290 |
SI Unit Control |
291 |
Indicates if device should only display SI unit codes |
292 |
Time Stamp |
293 |
Relative time value on network |
294 |
8u |
295 |
Dynamic Variables Returned for Device Variables |
296 |
Command Response Truncated |
297 |
Configuration Change Counter Mismatch |
298 |
Status bytes mismatch |
299 |
Warning - Loop Should be removed from automatic control |
300 |
Warning - This will affect sensor calibration |
301 |
Trim Menu |
302 |
Lower Trim;Upper Trim;Factory Recall;Exit |
303 |
%0 Trim Point
Lower : %1
Upper : %2 |
304 |
Is pressure stable?
Measured (PV) :
%0[%1] |
305 |
Apply trim point? |
306 |
NO;YES |
307 |
Writing apply value |
308 |
Now processing
Update trim point
Please wait... |
309 |
%0 Trim Value
Current : %1
Applied : %2 |
310 |
Adjust Menu |
311 |
Adjust Trim;Adjust Recall;Exit |
312 |
Input to the Adjust Value |
313 |
Complete Level Adjustment.
Current PV : %0 [%1] |
314 |
Complete Adjustment Recall. |
315 |
Cut PV Status
Mode : %0
Value : %1 [%] |
316 |
Change Cut PV ? |
317 |
Select Cut PV mode |
318 |
Write Cut PV Value
Range : 0 - 20 [%] |
319 |
Changed Cut PV
Mode : %0
Value : %1 [%] |
320 |
Select unit section |
321 |
Temperature; Pressure; Volumetric Flow; Velocity; Volume; Length; Time; Mass & Mass Flow; Mass per Volume; User Defined Unit |
322 |
Temperature Unit |
323 |
Volumetric Flow |
324 |
Velocity |
325 |
Volume |
326 |
Length |
327 |
Time |
328 |
Mass per Volume |
329 |
Input User Defined Unit |
330 |
Eng. Unit Changed. |
331 |
Now Clearing ... |
332 |
Complete more status clear |