0 |
APT3200 |
1 |
Autrol(Duon) |
2 |
Duon System |
3 |
Device Status |
4 |
Primary Variable Out of Limits |
5 |
Nob-Primary Variable Out of Limits |
6 |
Primary Variable Analog Output Saturated |
7 |
Primary Variable Analog Output Fixed |
8 |
More status available |
9 |
Cold Start |
10 |
Configuration Changed |
11 |
Field Device malfunction |
12 |
CPU Memory Access Violation |
13 |
OSC failure |
14 |
Autrol.GP.AP |
15 |
Autrol Setup |
16 |
Engineering |
17 |
This value is lower trim point of two point trim |
18 |
LowTrim |
19 |
7.3f |
20 |
This value is upper trim point of two point trim |
21 |
UpTrim |
22 |
Select trim mode |
23 |
Trim Mode |
24 |
Point |
25 |
Upper |
26 |
Lower |
27 |
Cleared |
28 |
Current PV value |
29 |
Current trim value |
30 |
8.4f |
31 |
Change current value to apply value for trim |
32 |
Apply trim value |
33 |
Invalid Unit Code |
34 |
Device transmitter variable code |
35 |
Xmtr Variable |
36 |
Pri-Var |
37 |
Sec-Var |
38 |
Tri-Var |
39 |
4th-Var |
40 |
Pressure Tranmitter Sensor Type Code |
41 |
Xmtr Sensor Type |
42 |
GP 2 |
43 |
GP 2-1 |
44 |
GP 2-2 |
45 |
GP 3 |
46 |
GP 4 |
47 |
GP 4-1 |
48 |
GP 4-2 |
49 |
GP 4-3 |
50 |
GP 4-4 |
51 |
GV 4 |
52 |
GV 4-1 |
53 |
GV 4-2 |
54 |
GV 4-3 |
55 |
GV 4-4 |
56 |
GP 5 |
57 |
GP 5-1 |
58 |
GV 5 |
59 |
GP 6 |
60 |
GP 6-1 |
61 |
GV 6 |
62 |
GV 6-1 |
63 |
GP 7 |
64 |
GV 7 |
65 |
GP 8 |
66 |
GV 8 |
67 |
GP 9 |
68 |
GV 9 |
69 |
AP 4 |
70 |
AP 4-1 |
71 |
AP 4-2 |
72 |
AP 4-3 |
73 |
AP 4-4 |
74 |
AP 5 |
75 |
AP 5-1 |
76 |
AP 6 |
77 |
#G6 |
78 |
#G4 |
79 |
#G5 |
80 |
#G7 |
81 |
#A4 |
82 |
#A5 |
83 |
#A6 |
84 |
#SG0 |
85 |
#SG1 |
86 |
#SG2 |
87 |
#SG3 |
88 |
#SG4 |
89 |
#SA5 |
90 |
#SA6 |
91 |
#SA7 |
92 |
Invalid Transmitter Variable Code |
93 |
LCD mode |
94 |
LCD Display Mode |
95 |
Normal> All Values |
96 |
Normal> PV Only |
97 |
Normal> % Only |
98 |
Normal> mA Only |
99 |
Eng> All Values |
100 |
Eng> PV Only |
101 |
Eng> [%] Only |
102 |
Eng> [mA]Only] |
103 |
|
104 |
Engr. Xfer Fnctn |
105 |
Linear |
106 |
Sqar Root |
107 |
Decimal Place |
108 |
Auto |
109 |
#.#### (1-4) |
110 |
##.### (2-3) |
111 |
###.## (3-2) |
112 |
####.# (4-1) |
113 |
#####. (5-0) |
114 |
Update Failure |
115 |
Engr. Range Unit |
116 |
User |
117 |
User Defined Unit |
118 |
Engr. LRV |
119 |
Engr. URV |
120 |
User Defined unit |
121 |
Change current PV to zero adjustmet value |
122 |
Adjust value |
123 |
Select Zero Adjust mode |
124 |
Adjust Mode |
125 |
Zero Adj. |
126 |
Cut-Off Value |
127 |
5.2f |
128 |
Cut-OFF Mode |
129 |
Linear |
130 |
Zero |
131 |
Two Point Trim |
132 |
Adjust Value |
133 |
Adjust Clear |
134 |
Sensor Type |
135 |
LCD |
136 |
Cut PV |
137 |
Self Test |
138 |
Master reset |
139 |
EEPROM PROTECT |
140 |
Eng. Mode Change |
141 |
Temp Unit |
142 |
Pressure Unit |
143 |
Volumetric flow Unit |
144 |
Velocity Unit |
145 |
Length Unit |
146 |
Time Unit |
147 |
Mass & Mass Flow |
148 |
Mass per volume |
149 |
RngUnit |
150 |
Dynamic Variables |
151 |
.1f |
152 |
.2f |
153 |
.3f |
154 |
.4f |
155 |
.5f |
156 |
8.3f |
157 |
.0f |
158 |
Cnt |
159 |
Count Number of Sensor |
160 |
kCnt |
161 |
k-Count Number of Sensor |
162 |
AO |
163 |
7d |
164 |
FMU860 |
165 |
DT |
166 |
DVC |
167 |
FCX |
168 |
AS800 |
169 |
340T |
170 |
340C |
171 |
344 |
172 |
Siemens Micro K |
173 |
SITRANS L |
174 |
SIPAN PH |
175 |
SITRANS P |
176 |
75SMT |
177 |
UNIDELTA |
178 |
8320 |
179 |
SX5100 |
180 |
TSV175 |
181 |
DMU |
182 |
3780 |
183 |
BM70 |
184 |
8u |
185 |
low |
186 |
high |
187 |
tmp_av |
188 |
Trim Menu |
189 |
Trim Point;Lower Trim;Upper Trim;Factory Recall;Exit |
190 |
Trim Point
Lower : %0
Upper : %1 |
191 |
%0 Trim Point
Lower : %1
Upper : %2 |
192 |
Is pressure stable?
Measured (PV) :
%0[%1] |
193 |
Apply trim point? |
194 |
NO;YES |
195 |
Writing apply value |
196 |
Now processing
Update trim point
Please wait... |
197 |
%0 Trim Value
Current : %1
Applied : %2 |
198 |
Quit Two Point Trim? |
199 |
Is pressure stable?
Measured PV :
%0 [%1] |
200 |
Change Value? |
201 |
Adjust Value? |
202 |
Adjusted Value :
%0 [%1] |
203 |
Clear Zero Adjust Value? |
204 |
Zero Adjust Cleared Value :
%0 [%1] |
205 |
Xmtr Variable? |
206 |
Xmtr Variable
> %0
Sensor Type
> %1 |
207 |
Current LCD mode
%0 |
208 |
Change LCD mode? |
209 |
Select LCD mode |
210 |
Changed LCD mode
%0 |
211 |
Current Decimal Place
%0 |
212 |
Change Decimal Place? |
213 |
Select Decimal Place |
214 |
Cut PV Status
Mode : %0
Value : %1 [%] |
215 |
Change Cut PV ? |
216 |
Select Cut PV mode |
217 |
Write Cut PV Value
Range : 0 - 20 [%] |
218 |
Changed Cut PV
Mode : %0
Value : %1 [%] |
219 |
About to Perform Limited Selftest |
220 |
Performing Selftest |
221 |
Device maybe stuck in Master Reset. |
222 |
Master reset OK |
223 |
Preform Master Reset |
224 |
Master Reset in
progress please wait |
225 |
Current EEPROM Mode |
226 |
Can't change
EEPROM Protect Mode
%0 |
227 |
Changed EEPROM Mode
%0 |
228 |
Change Eng. Mode ? |
229 |
Select unit section |
230 |
Temperature; Pressure; Volumetric Flow; Velocity; Volume; Length; Time; Mass & Mass Flow; Mass per Volume; User Defined Unit |
231 |
Temperature Unit |
232 |
Volumetric Flow |
233 |
Velocity |
234 |
Volume |
235 |
Length |
236 |
Time |
237 |
Mass per Volume |
238 |
Input User Defined Unit |
239 |
Lower range |
240 |
Upper range |
241 |
Transfer function |
242 |
Eng. Mode Changed. |