0 |
APT3100 |
1 |
Autrol(Duon) |
2 |
Duon System |
3 |
Device Status |
4 |
PV Out of Limit |
5 |
NPV Out of Limit |
6 |
PV AO Saturated |
7 |
PV AO Fixed |
8 |
More status |
9 |
Cold Start |
10 |
Config. Changed |
11 |
Device malftn |
12 |
Autrol.DP.DG.AP |
13 |
Autrol Setup |
14 |
Engineering |
15 |
This value is lower trim point of two point trim |
16 |
LowTrim |
17 |
7.3f |
18 |
This value is upper trim point of two point trim |
19 |
UpTrim |
20 |
Select trim mode |
21 |
Trim Mode |
22 |
Point |
23 |
Upper |
24 |
Lower |
25 |
Cleared |
26 |
Current PV value |
27 |
Current trim value |
28 |
8.4f |
29 |
Change current value to apply value for trim |
30 |
Apply trim value |
31 |
Invalid Unit Code |
32 |
Device transmitter variable code |
33 |
Xmtr Variable |
34 |
Pri-Var |
35 |
Sec-Var |
36 |
Tri-Var |
37 |
4th-Var |
38 |
Pressure Tranmitter Sensor Type Code |
39 |
Selected Xmtr Sensor |
40 |
(SI)DP-RC 3 |
41 |
(SI)DP-RC 4 |
42 |
(SI)DP-RC 5 |
43 |
(SI)DP-RC 6 |
44 |
(SI)DP-RC 7 |
45 |
(SI)DP-RC 8 |
46 |
(SI)DP-RC 9 |
47 |
(SI)DP-RC 0 |
48 |
(SI)GP-RC 3 |
49 |
(SI)GP-RC 4 |
50 |
(SI)GP-RC 5 |
51 |
(SI)GP-RC 6 |
52 |
(SI)GP-RC 7 |
53 |
(SI)GP-RC 8 |
54 |
(SI)GP-RC 9 |
55 |
(SI)GP-RC 0 |
56 |
(SI)AP-RC 3 |
57 |
(SI)AP-RC 4 |
58 |
(SI)AP-RC 5 |
59 |
(SI)AP-RC 6 |
60 |
(SI)AP-RC 7 |
61 |
(SI)AP-RC 8 |
62 |
(SI)AP-RC 9 |
63 |
(SI)AP-RC 0 |
64 |
(SI)HP-RC 4 |
65 |
(SI)HP-RC 5 |
66 |
(SI)HP-RC 6 |
67 |
(SI)HP-RC 7 |
68 |
(SI)LT-RC 4 |
69 |
(SI)LT-RC 5 |
70 |
(SI)LT-RC 6 |
71 |
(XY)DP-RC 3 |
72 |
(XY)DP-RC 4 |
73 |
(XY)DP-RC 5 |
74 |
(XY)DP-RC 6 |
75 |
(XY)DP-RC 7 |
76 |
(XY)DP-RC 8 |
77 |
(XY)DP-RC 9 |
78 |
(XY)DP-RC 0 |
79 |
(XY)GP-RC 3 |
80 |
(XY)GP-RC 4 |
81 |
(XY)GP-RC 5 |
82 |
(XY)GP-RC 6 |
83 |
(XY)GP-RC 7 |
84 |
(XY)GP-RC 8 |
85 |
(XY)GP-RC 9 |
86 |
(XY)GP-RC 0 |
87 |
(XY)AP-RC 3 |
88 |
(XY)AP-RC 4 |
89 |
(XY)AP-RC 5 |
90 |
(XY)AP-RC 6 |
91 |
(XY)AP-RC 7 |
92 |
(XY)AP-RC 8 |
93 |
(XY)AP-RC 9 |
94 |
(XY)AP-RC 0 |
95 |
(XY)HP-RC 4 |
96 |
(XY)HP-RC 5 |
97 |
(XY)HP-RC 6 |
98 |
(XY)LT-RC 4 |
99 |
(XY)LT-RC 5 |
100 |
(XY)LT-RC 6 |
101 |
Invalid Transmitter Variable Code |
102 |
LCD mode |
103 |
|
104 |
Normal> All Values |
105 |
Normal> PV Only |
106 |
Normal> % Only |
107 |
Normal> mA Only |
108 |
Eng> All Values |
109 |
Eng> PV Only |
110 |
Eng> [%] Only |
111 |
Eng> [mA]Only] |
112 |
XmtrFtn |
113 |
Linear |
114 |
Sqar Root |
115 |
Eng_Rng_Unit |
116 |
LowRng |
117 |
UpRng |
118 |
Update Failure |
119 |
Change current PV to zero adjustmet value |
120 |
Adjust value |
121 |
Cut-Off Value |
122 |
5.2f |
123 |
Cut-OFF Mode |
124 |
Linear |
125 |
Zero |
126 |
Two Point Trim |
127 |
Adjust Value |
128 |
Sensor Type |
129 |
LCD |
130 |
Cut PV |
131 |
Self Test |
132 |
Master reset |
133 |
EEPROM PROTECT |
134 |
Eng. Mode Change |
135 |
Temp Unit |
136 |
Pressure Unit |
137 |
Volumetric flow Unit |
138 |
Velocity Unit |
139 |
Length Unit |
140 |
Time Unit |
141 |
Mass & Mass Flow |
142 |
Mass per volume |
143 |
RngUnit |
144 |
Dynamic Variables |
145 |
Transmitter Status |
146 |
.1f |
147 |
.2f |
148 |
.3f |
149 |
.4f |
150 |
.5f |
151 |
8.3f |
152 |
.0f |
153 |
Cnt |
154 |
Count Number of Sensor |
155 |
kCnt |
156 |
k-Count Number of Sensor |
157 |
AO |
158 |
7d |
159 |
FMU860 |
160 |
DT |
161 |
DVC |
162 |
FCX |
163 |
AS800 |
164 |
340T |
165 |
340C |
166 |
344 |
167 |
Siemens Micro K |
168 |
SITRANS L |
169 |
SIPAN PH |
170 |
SITRANS P |
171 |
75SMT |
172 |
UNIDELTA |
173 |
8320 |
174 |
SX5100 |
175 |
TSV175 |
176 |
DMU |
177 |
3780 |
178 |
BM70 |
179 |
8u |
180 |
low |
181 |
high |
182 |
tmp_av |
183 |
Trim Menu |
184 |
Trim Point;Lower Trim;Upper Trim;Clear(Reset);Exit |
185 |
Trim Point
Lower : %0
Upper : %1 |
186 |
%0 Trim Point
Lower : %1
Upper : %2 |
187 |
Is pressure stable?
Measured (PV) :
%0[%1] |
188 |
Apply trim point? |
189 |
NO;YES |
190 |
Writing apply value |
191 |
Now processing
Update trim point
Please wait... |
192 |
%0 Trim Value
Current : %1
Applied : %2 |
193 |
Quit Two Point Trim? |
194 |
Is pressure stable?
Measured PV :
%0 [%1] |
195 |
Change Value? |
196 |
Adjust Value? |
197 |
Adjusted Value :
%0 [%1] |
198 |
Xmtr Variable? |
199 |
Xmtr Variable
> %0
Sensor Type
> %1 |
200 |
Current LCD mode
%0 |
201 |
Change LCD mode? |
202 |
Select LCD mode |
203 |
Changed LCD mode
%0 |
204 |
Cut PV Status
Mode : %0
Value : %1 [%] |
205 |
Change Cut PV ? |
206 |
Select Cut PV mode |
207 |
Write Cut PV Value
Range : 0 - 20 [%] |
208 |
Changed Cut PV
Mode : %0
Value : %1 [%] |
209 |
About to Perform Limited Selftest |
210 |
Performing Selftest |
211 |
Device maybe stuck in Master Reset. |
212 |
Master reset OK |
213 |
Preform Master Reset |
214 |
Master Reset in
progress please wait |
215 |
Current EEPROM Mode |
216 |
Can't change
EEPROM Protect Mode
%0 |
217 |
Changed EEPROM Mode
%0 |
218 |
Select unit section |
219 |
Temperature; Pressure; Volumetric Flow; Velocity; Volume; Length; Time; Mass & Mass Flow; Mass per Volume |
220 |
Temperature Unit |
221 |
Volumetric Flow |
222 |
Velocity |
223 |
Volume |
224 |
Length |
225 |
Time |
226 |
Mass per Volume |
227 |
Lower range |
228 |
Upper range |
229 |
Transfer function |