0 |
ALT6100 |
1 |
Autrol(Duon) |
2 |
Duon System |
3 |
Critical Power Failure |
4 |
Failure |
5 |
Out of Specification |
6 |
Function Check |
7 |
Device Variable Simulation active |
8 |
The device is in simulation mode and the level output is not representative of the process. |
9 |
Non-Volatile memory Defect |
10 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
11 |
Volatile memory Defect |
12 |
The RAM memory check is invalid or maybe corrupt |
13 |
Watchdog reset executed |
14 |
A watchdog reset has been performed |
15 |
Power Supply conditions out of range |
16 |
The power source, supply or voltage is outside its allowable range |
17 |
Environmental conditions out of range |
18 |
An internal or environmental condition is beyond acceptable limits. |
19 |
Electronic Defect |
20 |
A hardware problem not related to the sensor has been detected. |
21 |
Device Configuration Locked |
22 |
Device is in write-protect or is locked |
23 |
Status Simulation Active |
24 |
Discrete Variable Simulation Active |
25 |
Event Notification Overflow |
26 |
Sub-Device List Changed |
27 |
Duplicate Master Detected |
28 |
Sub-Device Mismatch |
29 |
Sub-Device with Duplicate IDs Found |
30 |
Stale Data Notice |
31 |
Capacity Denied |
32 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
33 |
Bandwidth allocation pending |
34 |
Block transfer pending |
35 |
Radio Failure |
36 |
External EEPROM write fail |
37 |
Flash Access violation |
38 |
Flash memory write fail |
39 |
Distance Data Over limit |
40 |
Sensor Data Over limit |
41 |
Sensor error |
42 |
Interface Echo Pulse not found |
43 |
Echo Pulse not found |
44 |
Counter limit over |
45 |
Sensor code error |
46 |
Oscillator Fault |
47 |
Calibration data error |
48 |
Thermometer error |
49 |
External EEPROM read fail |
50 |
Program memory CRC error |
51 |
.3f |
52 |
Lvl Dev fmly |
53 |
Lvl Class |
54 |
Lvl PDQ |
55 |
Lvl LS |
56 |
Lvl Fmly stat |
57 |
8.3f |
58 |
Lvl Update Period |
59 |
|
60 |
7d |
61 |
Lvl Lower trim |
62 |
Lvl Upper trim |
63 |
Lvl Trim support |
64 |
Lvl Min lower trim |
65 |
Lvl Max lower trim |
66 |
Lvl Min upper trim |
67 |
Lvl Max upper trim |
68 |
Lvl Min trim diff |
69 |
Simulate |
70 |
Level- Level of the process measured with respect to a reference level. |
71 |
Update Period |
72 |
Snsr temp unit |
73 |
Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. |
74 |
Temp Class |
75 |
Temp PDQ |
76 |
Temp LS |
77 |
Temp Dev Stat |
78 |
Temp USL |
79 |
Temp LSL |
80 |
Temp min span |
81 |
Temp Update Period |
82 |
Temp snsr s/n |
83 |
Secondary Variable - Temperature Compensation |
84 |
Level |
85 |
Temperature |
86 |
Select trim mode |
87 |
Trim Mode |
88 |
Point |
89 |
Upper |
90 |
Lower |
91 |
Cleared |
92 |
Current PV value |
93 |
Current trim value |
94 |
8.4f |
95 |
Change current value to apply value for trim |
96 |
Apply trim value |
97 |
Invalid Unit Code |
98 |
Device transmitter variable code |
99 |
Xmtr Variable |
100 |
Pri-Var |
101 |
Sec-Var |
102 |
Tri-Var |
103 |
4th-Var |
104 |
GWR Sensor Type Code |
105 |
Selected Sensor Type |
106 |
Coaxial Probe |
107 |
Single Flexible Rod |
108 |
Single Rigid Rod |
109 |
Twin Flexible Rod |
110 |
Twin Rigid Rod |
111 |
Invalid Transmitter Variable Code |
112 |
LCD mode |
113 |
LCD Display Mode |
114 |
Normal> All Values |
115 |
Normal> PV Only |
116 |
Normal> % Only |
117 |
Normal> mA Only |
118 |
Eng> All Values |
119 |
Eng> PV Only |
120 |
Engr. Xfer Fnctn |
121 |
Linear |
122 |
Sqar Root |
123 |
Decimal Place |
124 |
Auto |
125 |
#.#### (1-4) |
126 |
##.### (2-3) |
127 |
###.## (3-2) |
128 |
####.# (4-1) |
129 |
#####. (5-0) |
130 |
Update Failure |
131 |
Engr. Range Unit |
132 |
User |
133 |
User Defined Unit |
134 |
Engr. LRV |
135 |
Engr. URV |
136 |
User Defined unit |
137 |
Change current PV to zero adjustmet value |
138 |
Adjust value |
139 |
Select Zero Adjust mode |
140 |
Adjust Mode |
141 |
Zero Adj. |
142 |
Cut-Off Value |
143 |
5.2f |
144 |
Cut-OFF Mode |
145 |
Linear |
146 |
Zero |
147 |
PV is |
148 |
Distance |
149 |
Volume |
150 |
Interface Level |
151 |
Interface Distance |
152 |
Upper Thickness |
153 |
Interface Volume |
154 |
Tank Height |
155 |
Probe Length |
156 |
Probe Angle |
157 |
Upper M. DK |
158 |
Two Point Trim |
159 |
Level Adjust |
160 |
Cut PV |
161 |
EEPROM PROTECT |
162 |
Eng. Unit Change |
163 |
Level Value Change |
164 |
More Status Clear |
165 |
Temp Unit |
166 |
Pressure Unit |
167 |
Volumetric flow Unit |
168 |
Velocity Unit |
169 |
Length Unit |
170 |
Time Unit |
171 |
Mass & Mass Flow |
172 |
Mass per volume |
173 |
RngUnit |
174 |
Autrol.GWR |
175 |
Autrol Setup |
176 |
LCD output |
177 |
Dynamic Variables |
178 |
Transmitter Status |
179 |
Level Setup |
180 |
PV Analog Channel Saturated |
181 |
PV Analog Channel Fixed |
182 |
Wireless |
183 |
WirelessHART Device |
184 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
185 |
Primary |
186 |
Primary Analog Channel |
187 |
Secondary |
188 |
Secondary Analog Channel |
189 |
Tertiary |
190 |
Tertiary Analog Channel |
191 |
Quaternary |
192 |
Quaternary Analog Channel |
193 |
Quinary |
194 |
Quinary Analog Channel |
195 |
Lock all |
196 |
Trim not supported |
197 |
Configuration cannot be changed |
198 |
Locked by gateway |
199 |
Analog Input Channel |
200 |
Analog Output Channel |
201 |
Secondary Analog Channel Saturated |
202 |
Tertiary Analog Channel Saturated |
203 |
Quaternary Analog Channel Saturated |
204 |
Quinary Analog Channel Saturated |
205 |
Secondary Analog Channel Fixed |
206 |
Tertiary Analog Channel Fixed |
207 |
Quaternary Analog Channel Fixed |
208 |
Quinary Analog Channel Fixed |
209 |
Simulation active |
210 |
Non-Volatile memory failure |
211 |
Volatile memory error |
212 |
Voltage conditions out of range |
213 |
A voltage condition is outside its allowable range |
214 |
Electronic failure |
215 |
Subdevice list changed |
216 |
Duplicate master detected |
217 |
Battery life |
218 |
Percent range |
219 |
Loop current |
220 |
Primary variable |
221 |
Secondary variable |
222 |
Tertiary variable |
223 |
Quaternary variable |
224 |
Read receive time |
225 |
Write date and time |
226 |
Non-Volatile Clock |
227 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
228 |
Clock Uninitialized |
229 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
230 |
None |
231 |
No restrictions |
232 |
SI Only |
233 |
Restricted to SI Unit codes only |
234 |
Process automation device |
235 |
Discrete device |
236 |
Hybrid:Process automation+discrete |
237 |
I/O System |
238 |
WirelessHART Process automation device |
239 |
WirelessHART Discrete device |
240 |
WirelessHART Process automation+discrete |
241 |
WirelessHART Gateway |
242 |
WirelessHART Access point |
243 |
WirelessHART Process adapter |
244 |
WirelessHART Discrete adapter |
245 |
WirelessHART enabled handheld/portable maintenance tool |
246 |
Device Profile |
247 |
US |
248 |
United States of America |
249 |
JP |
250 |
Japan |
251 |
DE |
252 |
Germany |
253 |
FR |
254 |
France |
255 |
ES |
256 |
Spain |
257 |
RU |
258 |
Russian Federation |
259 |
CN |
260 |
People's Republic of China |
261 |
Secondary Master |
262 |
Primary Master |
263 |
Device Diagnostic Status 0 |
264 |
Device Diagnostic Status 1 |
265 |
I/O and Subdevice Status |
266 |
WirelessHART Status |
267 |
Time Set Option |
268 |
Real Time Clock Flags |
269 |
Country |
270 |
Country of intended device installation |
271 |
SI Unit Control |
272 |
Indicates if device should only display SI unit codes |
273 |
Time Stamp |
274 |
Relative time value on network |
275 |
8u |
276 |
Dynamic Variables Returned for Device Variables |
277 |
Command Response Truncated |
278 |
Configuration Change Counter Mismatch |
279 |
Status bytes mismatch |
280 |
Warning - Loop Should be removed from automatic control |
281 |
Warning - This will affect sensor calibration |
282 |
Trim Menu |
283 |
Lower Trim;Upper Trim;Factory Recall;Exit |
284 |
%0 Trim Point
Lower : %1
Upper : %2 |
285 |
Is pressure stable?
Measured (PV) :
%0[%1] |
286 |
Apply trim point? |
287 |
NO;YES |
288 |
Writing apply value |
289 |
Now processing
Update trim point
Please wait... |
290 |
%0 Trim Value
Current : %1
Applied : %2 |
291 |
Adjust Menu |
292 |
Level Adjust;Adjust Recall;Exit |
293 |
Input to the Adjust Value |
294 |
Complete Level Adjustment.
Current PV : %0 [%1] |
295 |
This Function don't works if the 'PV_is_Mode' value is set to the 'Level'. |
296 |
Complete Adjustment Recall. |
297 |
Cut PV Status
Mode : %0
Value : %1 [%] |
298 |
Change Cut PV ? |
299 |
Select Cut PV mode |
300 |
Write Cut PV Value
Range : 0 - 20 [%] |
301 |
Changed Cut PV
Mode : %0
Value : %1 [%] |
302 |
Current EEPROM Mode |
303 |
Can't change
EEPROM Protect Mode
%0 |
304 |
Changed EEPROM Mode
%0 |
305 |
Select unit section |
306 |
Temperature; Pressure; Volumetric Flow; Velocity; Volume; Length; Time; Mass & Mass Flow; Mass per Volume; User Defined Unit |
307 |
Temperature Unit |
308 |
Volumetric Flow |
309 |
Velocity |
310 |
Length |
311 |
Time |
312 |
Mass per Volume |
313 |
Input User Defined Unit |
314 |
Eng. Unit Changed. |
315 |
Change Level Parameter ? |
316 |
Changed Level Parameters
Tank Height : %0
Probe Length : %1
Probe Angle : %2 |
317 |
Complete more status clear |