0 |
ALT6100 |
1 |
Autrol(Duon) |
2 |
Duon System |
3 |
Critical Power Failure |
4 |
Failure |
5 |
Out of Specification |
6 |
Function Check |
7 |
Device Variable Simulation active |
8 |
The device is in simulation mode and the level output is not representative of the process. |
9 |
Non-Volatile memory Defect |
10 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
11 |
Volatile memory Defect |
12 |
The RAM memory check is invalid or maybe corrupt |
13 |
Watchdog reset executed |
14 |
A watchdog reset has been performed |
15 |
Power Supply conditions out of range |
16 |
The power source, supply or voltage is outside its allowable range |
17 |
Environmental conditions out of range |
18 |
An internal or environmental condition is beyond acceptable limits. |
19 |
Electronic Defect |
20 |
A hardware problem not related to the sensor has been detected. |
21 |
Device Configuration Locked |
22 |
Device is in write-protect or is locked |
23 |
Status Simulation Active |
24 |
Discrete Variable Simulation Active |
25 |
Event Notification Overflow |
26 |
Sub-Device List Changed |
27 |
Duplicate Master Detected |
28 |
Sub-Device Mismatch |
29 |
Sub-Device with Duplicate IDs Found |
30 |
Stale Data Notice |
31 |
Capacity Denied |
32 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
33 |
Bandwidth allocation pending |
34 |
Block transfer pending |
35 |
Radio Failure |
36 |
External EEPROM write fail |
37 |
Flash Access violation |
38 |
Flash memory write fail |
39 |
Distance Data Over limit |
40 |
Sensor Data Over limit |
41 |
Sensor error |
42 |
Interface Echo Pulse not found |
43 |
Echo Pulse not found |
44 |
Counter limit over |
45 |
Sensor code error |
46 |
Oscillator Fault |
47 |
Calibration data error |
48 |
Thermometer error |
49 |
External EEPROM read fail |
50 |
Program memory CRC error |
51 |
.3f |
52 |
Lvl Dev fmly |
53 |
Lvl Class |
54 |
Lvl PDQ |
55 |
Lvl LS |
56 |
Lvl Fmly stat |
57 |
8.3f |
58 |
Lvl Update Period |
59 |
|
60 |
s |
61 |
7d |
62 |
Lvl Lower trim |
63 |
Lvl Upper trim |
64 |
Lvl Trim support |
65 |
Lvl Min lower trim |
66 |
Lvl Max lower trim |
67 |
Lvl Min upper trim |
68 |
Lvl Max upper trim |
69 |
Lvl Min trim diff |
70 |
Simulate |
71 |
Level- Level of the process measured with respect to a reference level. |
72 |
Update Period |
73 |
Snsr temp unit |
74 |
Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. |
75 |
Temp Class |
76 |
Temp PDQ |
77 |
Temp LS |
78 |
Temp Dev Stat |
79 |
Temp USL |
80 |
Temp LSL |
81 |
Temp min span |
82 |
Temp Update Period |
83 |
Temp snsr s/n |
84 |
Secondary Variable - Temperature Compensation |
85 |
Level |
86 |
Temperature |
87 |
Select trim mode |
88 |
Trim Mode |
89 |
Point |
90 |
Upper |
91 |
Lower |
92 |
Cleared |
93 |
Current PV value |
94 |
Current trim value |
95 |
8.4f |
96 |
Change current value to apply value for trim |
97 |
Apply trim value |
98 |
Invalid Unit Code |
99 |
Device transmitter variable code |
100 |
Xmtr Variable |
101 |
Pri-Var |
102 |
Sec-Var |
103 |
Tri-Var |
104 |
4th-Var |
105 |
GWR Sensor Type Code |
106 |
Selected Sensor Type |
107 |
Coaxial Probe |
108 |
Single Flexible Rod |
109 |
Single Rigid Rod |
110 |
Twin Flexible Rod |
111 |
Twin Rigid Rod |
112 |
Invalid Transmitter Variable Code |
113 |
LCD mode |
114 |
LCD Display Mode |
115 |
Normal> All Values |
116 |
Normal> PV Only |
117 |
Normal> % Only |
118 |
Normal> mA Only |
119 |
Eng> All Values |
120 |
Eng> PV Only |
121 |
Engr. Xfer Fnctn |
122 |
Linear |
123 |
Sqar Root |
124 |
Decimal Place |
125 |
Auto |
126 |
#.#### (1-4) |
127 |
##.### (2-3) |
128 |
###.## (3-2) |
129 |
####.# (4-1) |
130 |
#####. (5-0) |
131 |
Update Failure |
132 |
Engr. Range Unit |
133 |
User |
134 |
User Defined Unit |
135 |
Engr. LRV |
136 |
Engr. URV |
137 |
User Defined unit |
138 |
Change current PV to zero adjustmet value |
139 |
Adjust value |
140 |
Select Zero Adjust mode |
141 |
Adjust Mode |
142 |
Zero Adj. |
143 |
Cut-Off Value |
144 |
5.2f |
145 |
Cut-OFF Mode |
146 |
Linear |
147 |
Zero |
148 |
PV is |
149 |
Distance |
150 |
Volume |
151 |
Interface Level |
152 |
Interface Distance |
153 |
Upper Thickness |
154 |
Interface Volume |
155 |
Tank Height |
156 |
Probe Length |
157 |
Probe Angle |
158 |
Upper M. DK |
159 |
Two Point Trim |
160 |
Level Adjust |
161 |
Cut PV |
162 |
EEPROM PROTECT |
163 |
Eng. Unit Change |
164 |
Level Value Change |
165 |
More Status Clear |
166 |
Temp Unit |
167 |
Pressure Unit |
168 |
Volumetric flow Unit |
169 |
Velocity Unit |
170 |
Length Unit |
171 |
Time Unit |
172 |
Mass & Mass Flow |
173 |
Mass per volume |
174 |
RngUnit |
175 |
Autrol.GWR |
176 |
Autrol Setup |
177 |
LCD output |
178 |
Dynamic Variables |
179 |
Transmitter Status |
180 |
Level Setup |
181 |
PV Analog Channel Saturated |
182 |
PV Analog Channel Fixed |
183 |
Wireless |
184 |
WirelessHART Device |
185 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
186 |
Primary |
187 |
Primary Analog Channel |
188 |
Secondary |
189 |
Secondary Analog Channel |
190 |
Tertiary |
191 |
Tertiary Analog Channel |
192 |
Quaternary |
193 |
Quaternary Analog Channel |
194 |
Quinary |
195 |
Quinary Analog Channel |
196 |
Lock all |
197 |
Trim not supported |
198 |
Configuration cannot be changed |
199 |
Locked by gateway |
200 |
Analog Input Channel |
201 |
Analog Output Channel |
202 |
Secondary Analog Channel Saturated |
203 |
Tertiary Analog Channel Saturated |
204 |
Quaternary Analog Channel Saturated |
205 |
Quinary Analog Channel Saturated |
206 |
Secondary Analog Channel Fixed |
207 |
Tertiary Analog Channel Fixed |
208 |
Quaternary Analog Channel Fixed |
209 |
Quinary Analog Channel Fixed |
210 |
Simulation active |
211 |
Non-Volatile memory failure |
212 |
Volatile memory error |
213 |
Voltage conditions out of range |
214 |
A voltage condition is outside its allowable range |
215 |
Electronic failure |
216 |
Subdevice list changed |
217 |
Duplicate master detected |
218 |
Battery life |
219 |
Percent range |
220 |
Loop current |
221 |
Primary variable |
222 |
Secondary variable |
223 |
Tertiary variable |
224 |
Quaternary variable |
225 |
Read receive time |
226 |
Write date and time |
227 |
Non-Volatile Clock |
228 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
229 |
Clock Uninitialized |
230 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
231 |
None |
232 |
No restrictions |
233 |
SI Only |
234 |
Restricted to SI Unit codes only |
235 |
Process automation device |
236 |
Discrete device |
237 |
Hybrid:Process automation+discrete |
238 |
I/O System |
239 |
WirelessHART Process automation device |
240 |
WirelessHART Discrete device |
241 |
WirelessHART Process automation+discrete |
242 |
WirelessHART Gateway |
243 |
WirelessHART Access point |
244 |
WirelessHART Process adapter |
245 |
WirelessHART Discrete adapter |
246 |
WirelessHART enabled handheld/portable maintenance tool |
247 |
Device Profile |
248 |
US |
249 |
United States of America |
250 |
JP |
251 |
Japan |
252 |
DE |
253 |
Germany |
254 |
FR |
255 |
France |
256 |
ES |
257 |
Spain |
258 |
RU |
259 |
Russian Federation |
260 |
CN |
261 |
People's Republic of China |
262 |
Secondary Master |
263 |
Primary Master |
264 |
Device Diagnostic Status 0 |
265 |
Device Diagnostic Status 1 |
266 |
I/O and Subdevice Status |
267 |
WirelessHART Status |
268 |
Time Set Option |
269 |
Real Time Clock Flags |
270 |
Country |
271 |
Country of intended device installation |
272 |
SI Unit Control |
273 |
Indicates if device should only display SI unit codes |
274 |
8u |
275 |
Dynamic Variables Returned for Device Variables |
276 |
Command Response Truncated |
277 |
Configuration Change Counter Mismatch |
278 |
Status bytes mismatch |
279 |
Output Status |
280 |
Output Status Byte |
281 |
Uninitialized |
282 |
Normal - one sensor |
283 |
Normal - two sensors |
284 |
Normal - three sensors |
285 |
Shorted |
286 |
Shorted- shorted field wiring. |
287 |
Limited high |
288 |
Limited high- block can not respond to upward movement of value. |
289 |
Open |
290 |
Open- open field wiring. |
291 |
Limited low |
292 |
Limited low- block can not respond to upward movement of target. |
293 |
Initialization done |
294 |
Initialization done- block initialization is complete. |
295 |
Not selected |
296 |
Not selected- target value provided by block was not selected. |
297 |
No path |
298 |
No path- there is no path to the process. |
299 |
Fail |
300 |
Fail- hardware failure. |
301 |
Bad |
302 |
Bad- block is out of service or has bad input. |
303 |
Not from process |
304 |
Not from process- value is not directly affected by any process information. |
305 |
Local override |
306 |
Local override- block has LO mode. |
307 |
Not Cascade Mode |
308 |
Not RCas Mode |
309 |
Not ROut Mode |
310 |
No communication |
311 |
No communication- (NO_COM). |
312 |
uint16_var_blk_char |
313 |
uint32_var_blk_char |
314 |
uint8_var_blk_char |
315 |
int8_var_blk_char |
316 |
new itest redef1 label |