0 |
AS700 |
1 |
AS800 |
2 |
all measurement values |
3 |
Invalid float format |
4 |
current out of range |
5 |
EEPROM-Access-Error |
6 |
CONFI-DATA-EEPROM cross sum error |
7 |
SENSOR-DATA-EEPROM cross sum error |
8 |
incorrect EEPROM-Marker |
9 |
EEPROM-Restorations counter |
10 |
EEPROM-Restoration |
11 |
5u |
12 |
Counter for incorrect HART-Frames |
13 |
TIME OUT Counter |
14 |
Counter of HART GAP Errors |
15 |
Gap Error Counter |
16 |
Counter for Warmstarts |
17 |
Warmstart Counter |
18 |
Pressure- Measured proccess pressure in relation to a reference pressure. |
19 |
Field Device Variable Unit- unit in which digital value, minimum span, upper range value, lower range value, lower sensor limit, upper sensor limit, lower sensor trim point and upper sensor trim point are displayed. Pressure- Measured process pressure in relation to a reference pressure. |
20 |
Field Device Variable Value- Digital value that can change without user intervention. Pressure- Measured proccess pressure in relation to a reference pressure. |
21 |
Percent of Range- Variable which represents the digital value with respect to the range defined by the lower range value and upper range value. For normal operating modes. This variable is always in percent. Pressure- Measured process pressure in relation to a reference pressure. |
22 |
.1f |
23 |
Upper Sensor Limit Value- Defines the maximum value able to be used for the upper range value. Pressure- Measured proccess pressure in relation to a reference pressure. |
24 |
Lower Sensor Limit Value- Defines the lowest allowable value for the lower range value. Pressure- Pressure of the process with respect to a reference pressure. |
25 |
Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Measured proccess pressure in relation to a reference pressure. |
26 |
Upper Range Value- Defines the endpoint for the analog value and the 100% point of the percent range. The upper range value also defines the operational endpoint from which the alarms for the analog output value as well as the associated digital value are taken. Pressure- Measured proccess pressure in relation to a reference pressure. |
27 |
Lower Range Value- Defines the operational endpoint or the analog output signal and 0% of the percent range. In addition, the lower range value defines an operational endpoint from which the alarm values for the analog output as well as the associated digital value are derived. Pressure- Pressure of the process with respect to a reference pressure. |
28 |
Damping Value- Damping time which affects both the digital and analog output values. The variable is always in seconds. Pressure- Pressure of the process with respect to a reference pressure. |
29 |
.3f |
30 |
6.3f |
31 |
Flange Type- Part next to the sensor which physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. |
32 |
Flange and 1/4 NPT |
33 |
DIN 19213 and 1/4 NPT |
34 |
DIN16288: B-G 1/2A |
35 |
DIN16288: D-G 1/2A |
36 |
NPT1/2 '' male thread |
37 |
NPT1/2 '' fem. thread |
38 |
O Ring Material- Material of the seal between the module and flange. |
39 |
1.4571 |
40 |
1.4571/1.4404 |
41 |
Hastelloy C/1.4571 |
42 |
FEP |
43 |
1.4435/1.4571 |
44 |
Meter Installation- Defines whether or not a meter is installed and what information is able to be seen in the display. |
45 |
analog display |
46 |
3 1/2 digit digital display |
47 |
Remote Seal Type- Type of remote seal connected to the device. This is only true when only 1 remote seal is installed. |
48 |
Flush diaphragm DN 25 |
49 |
Fl. diaphr. ANSI 1'' |
50 |
Fl. diaphragm DN 50 |
51 |
Fl. diaphr. ANSI 2'' |
52 |
Fl. diaphragm DN 80 |
53 |
Fl. diaphr. ANSI 3'' |
54 |
Ext. diaphragm DN 50 |
55 |
Ext.diaphr. ANSI 2'' |
56 |
Ext. diaphragm DN 80 |
57 |
Ext.diaphr. ANSI 3'' |
58 |
Tube RS DN25/ANSI1'' |
59 |
Tube RS DN40/1.5'' |
60 |
Tube RS DN50/2'' |
61 |
Tube RS DN80/3'' |
62 |
RS w. cap screw DN50 |
63 |
RS clamp connect.2'' |
64 |
Miniature RS G 1 A |
65 |
Miniature RS G 1/2 A |
66 |
Sensor Fill Fluid- Fluid in the module. |
67 |
Fluor carbon |
68 |
Destilled water |
69 |
High temperature oil |
70 |
Vegetable Oil |
71 |
Number of Remote Seals- Number of remote seals on the device. |
72 |
Send Warning- Sends a unit code warning to the user. |
73 |
Send Warning |
74 |
Sensor Serial Number- Clearly defines the sensor from which the digital value or the field device variable is primarily taken. Pressure Sensor- Hardware that measures pressure with respect to a reference pressure. |
75 |
Lower Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. Pressure Sensor- Measured proccess pressure in relation to a reference pressure. |
76 |
Lower sensor trim point |
77 |
Upper Sensor Trim Point- Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor- Measured proccess pressure in relation to a reference pressure. |
78 |
Upper sensor trim point |
79 |
Analog Output Value- Value that corresponds with the digital variable under normal operating modes. Analog Output- Measureable physical output which can change user intervention. |
80 |
Analog Output Alarm Type- Defines how the analog output responds when the field device detects that the analog output does not correspond with the field device variable. NOTE- The digital value can be undefined. Analog Output- Measureable physical output which can change without user intervention. |
81 |
AO alrm typ |
82 |
Measurement Type- Type of measurement this field device is intended to be used for. |
83 |
S 043 |
84 |
S 090 |
85 |
S 063 |
86 |
S 056 |
87 |
S 036 |
88 |
S 057 |
89 |
S 091 |
90 |
S 062 |
91 |
S 033 |
92 |
S 056 LC (LOW-COST) |
93 |
S 036 LC (LOW-COST) |
94 |
S 057 LC (LOW-COST) |
95 |
Flange Material- Material of flange type. |
96 |
Remote Seal Isolator Material- Remote seal material of the parts which come in contact with the process medium. This is only true so long only 1 remote seal is installed. |
97 |
Sensor Isolator Material- Material of a part of the sensor which comes in contact with the process material. |
98 |
Drain Vent Material- Material of a removable plug in the flange which can be opened to remove unwanted process medium from the sensor area. |
99 |
Local Keys Control Mode- Controls the mode of the User Interface keys on the Field Device. |
100 |
Sensors |
101 |
Pressure Sensor |
102 |
Pres sens info |
103 |
Sens temp sensor |
104 |
Version 1.10 |
105 |
English |
106 |
Language of strings |
107 |
Field Device Variable Unit- Digital unit that the variable is displayed in. Sensor Temperature- Temperature of the sensor which measures the proccess. |
108 |
Snsr temp unit |
109 |
Field Device Variable Value- Digital value that changes with respect to process or ambient temperature over time with no user intervention. Sensor Temperature- Temperature of the sensor wich measures the process. |
110 |
Sensor Temperature -Temperature of the sensor which measures the proccess. |
111 |
Tertiary Variable Unit- Digital unit that the tertiary variable is displayed in. Tertiary Variable-Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. All units are possible. |
112 |
TV unit |
113 |
Tertiary Variable Value- Digital value that changes with respect to process over time with no user intervention. Tertiary Variable-Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. All units are possible. |
114 |
TV Value |
115 |
.2e |
116 |
TV |
117 |
Tertiary Variable- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. All units are possible. |
118 |
Primary Variable- Primary variable of the process. Secondary Variable- Secondary variable of the process. Tertiary Variable- Tertiary variable of the process. |
119 |
Remote Seal Fill Fluid- Type of fluid in the device's remote seal. |
120 |
Module Range Code- code for the measurement range of the transmitter's measurement cell. |
121 |
10mbar |
122 |
60mbar |
123 |
400mbar |
124 |
2.5bar |
125 |
16bar |
126 |
40bar |
127 |
100bar |
128 |
250bar |
129 |
600bar |
130 |
Rated Pressure- Highest operating pressure which may be applied simultaneously to both measuring chambers. |
131 |
Rated Pressure |
132 |
2.5bar |
133 |
6bar |
134 |
25bar |
135 |
400bar |
136 |
63bar |
137 |
64bar |
138 |
160bar |
139 |
150psi |
140 |
300psi |
141 |
600psi |
142 |
1500psi |
143 |
Performs self test on the AS800. Will reports any errors. |
144 |
Stuck in self test |
145 |
Self test OK |
146 |
Master reset |
147 |
Resets the AS800 electronics. |
148 |
Master reset OK |
149 |
FMU860 |
150 |
DT |
151 |
DVC |
152 |
FCX |
153 |
AS800 |
154 |
340T |
155 |
340C |
156 |
344 |
157 |
Siemens Micro K |
158 |
SITRANS L |
159 |
SIPAN PH |
160 |
SITRANS P |
161 |
75SMT |
162 |
UNIDELTA |
163 |
8320 |
164 |
SX5100 |
165 |
TSV175 |
166 |
DMU |
167 |
3780 |
168 |
BM70 |
169 |
8u |
170 |
Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. |
171 |
Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. |
172 |
.3g |
173 |
.f |
174 |
.2f |
175 |
Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. |
176 |
% |
177 |
3.2f |
178 |
Sensor Limit Units and Minimum Span Units- Engineering unit to be displayed with the Upper Sensor Limit, Lower Sensor Limit, and Minimum Span. Pressure- Pressure of the process measured with respect to a reference pressure. |
179 |
Upper Sensor Limit Value- Defines the maximum useable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. |
180 |
Lower Sensor Limit Value- Defines the minimum useable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. |
181 |
Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. |
182 |
Pres xfer fnctn |
183 |
Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. Pressure- Pressure of the process measured with respect to a reference pressure. |
184 |
Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. |
185 |
Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. |
186 |
Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. |
187 |
Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. |
188 |
s |
189 |
4.2f |
190 |
Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. |
191 |
O Ring Material- Construction material of a seal that exists between the module and flange. |
192 |
Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. |
193 |
Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. |
194 |
Sensor Fill Fluid- Fluid material in the module. |
195 |
Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed. |
196 |
Send warning |
197 |
Send Warning- Yields a units code notice to the User. |
198 |
Variables which use this as the units code will be in the previous units until this value is sent to the device. |
199 |
Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes. Analog Output- Measureable physical output which changes with respect to time, without user intervention. |
200 |
5.3f |
201 |
Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. Analog Output- Measureable physical output which changes with respect to time, without user intervention. |
202 |
Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. |
203 |
Measurement Type- Type of measurement application this Field Device is intended to be used with. |
204 |
Lower Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. |
205 |
6.4f |
206 |
.4f |
207 |
Upper Sensor Trim Point- Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. |
208 |
Flange Material- Construction material of flange type. |
209 |
Remote Seal Isolator Material- Construction material of a part of the remote seal type that comes in contact with the process material. This is only unambiguous if 1 remote seal is installed. |
210 |
Sensor Isolator Material- Construction material of a part of the module type that comes in contact with the process material. |
211 |
Local Keys Control Mode- Controls the mode of the User Interface keys on the Field Device. |
212 |
Drain Vent Material- Construction material of a removable plug that exists on the flange type that can be opened temporarily to remove unwanted process from the sensor area. |
213 |
RAM Failure |
214 |
ROM cross sum error |
215 |
EEPROM-Restoration = |
216 |
TIME OUT Counter = |
217 |
Gap Error Counter = |
218 |
Warmstart Counter = |
219 |
Device maybe stuck in selftest. |
220 |
Please wait ... |
221 |
Master reset OK |
222 |
Variables with this unit maintain their old value until a new unit has been sent to the device. |