Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
device_status_mask | 08DB | Device Status Mask | R/W | BitEnum | 2048 | |
extended_fld_device_status_mask | 08DC | Extended Device Status Mask | R/W | BitEnum | 2048 | |
standardized_status_0_mask | 08DD | Standardized Status 0 Mask | R/W | BitEnum | 2048 | |
standardized_status_1_mask | 08DE | Standardized Status 1 Mask | R/W | BitEnum | 2048 | |
standardized_status_2_mask | 08DF | Device Diagnostic Status 2 Mask | R/W | BitEnum | 2048 | |
standardized_status_3_mask | 08E0 | Device Diagnostic Status 3 Mask | R/W | BitEnum | 2048 | |
analog_channel_saturated1_mask | 08E1 | AO saturated Mask | R/W | BitEnum | 2048 | |
analog_channel_fixed1_mask | 08E2 | AO fixed Mask | R/W | BitEnum | 2048 | |
device_status_latched_value | 08E3 | Latched Device Status | W | BitEnum | 2049 | |
dev_operating_mode_mask | 08F9 | Operate mode Mask | R/W | BitEnum | 2048 | |
extended_fld_device_status_latched_value | 08E4 | Latched Ext dev status | W | BitEnum | 2049 | |
standardized_status_0_latched_value | 08E5 | Latched Device Diagnostic Status 0 | W | BitEnum | 2049 | |
standardized_status_1_latched_value | 08E6 | Latched Device Diagnostic Status 1 | W | BitEnum | 2049 | |
standardized_status_2_latched_value | 08E7 | Latched Device Diagnostic Status 2 | W | BitEnum | 2049 | |
standardized_status_3_latched_value | 08E8 | Latched Device Diagnostic Status 3 | W | BitEnum | 2049 | |
analog_channel_saturated1_latched_value | 08E9 | Latched AO saturated | W | BitEnum | 2049 | |
analog_channel_fixed1_latched_value | 08EA | Latched AO fixed | W | BitEnum | 2049 | |
dev_operating_mode_latched_value | 08FA | Latched Operate Mode | W | Enum | 2049 | |
lock_device_code | 106F | Lock dev code | Lock Device Code- Indicates whether the device has been placed in a locked position to prevent any changes from being made manually or from another master. | W | Enum | 2048 |
lock_device_status_code | 1070 | Lock dev status | Lock Device Code- Indicates whether the device has been placed in a locked position to prevent any changes from being made manually or from another master. | R | BitEnum | 2048 |
response_code | 0096 | Response code | Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. | R | Enum | 129 |
comm_status | 0098 | Communication status | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. | R | BitEnum | 131 |
request_preambles | 009B | Num req preams | Number of Request Preambles- Number of Preambles required from the Host request by the Field Device | R | Unsigned | 128 |
universal_revision | 009C | Universal rev | Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to | R | Unsigned | 128 |
transmitter_revision | 009D | Fld dev rev | Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to | R | Unsigned | 128 |
software_revision | 009E | Software rev | Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device | R | Unsigned | 2048 |
hardware_revision | 009F | Hardware rev | Hardware Revision- Revision that corresponds to the electronics hardware of the Field Device. | R | Unsigned | 2048 |
device_id | 00A1 | Dev id | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. | R | Unsigned | 2048 |
response_preambles | 0FE2 | Num resp preams | Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host | R | Unsigned | 128 |
max_num_device_variables | 00CE | Max dev vars | Maximum Number of Device Variables- This indicates the last Device Variable code that a host application should expect to be found in the field device (e.g., when identifying the Device Variables using Command 54) | R | Unsigned | 2048 |
config_change_counter | 00CF | Cfg chng count | Configuration Change Counter- This indicates the number of times the devices configuration or calibration has been changed by a host application or from a local operator interface. | R | Unsigned | 2050 |
tag | 00A3 | Tag | Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. | R/W | PackedAscii | 2048 |
longTag | 00D2 | Long tag | Long Tag- Functions exactly like Tag except the size is larger (max of 32 ISO Latin 1 characters). | R/W | ASCII | 2048 |
device_variable_code_1 | 00E1 | R/W | Index | 4096 | ||
device_variable_code_2 | 00E2 | R/W | Index | 4096 | ||
device_variable_code_3 | 00E3 | R/W | Index | 4096 | ||
device_variable_code_4 | 00E4 | R/W | Index | 4096 | ||
device_variable_code_5 | 0100 | R/W | Index | 4096 | ||
device_variable_code_6 | 0101 | R/W | Index | 4096 | ||
device_variable_code_7 | 0102 | R/W | Index | 4096 | ||
device_variable_code_8 | 0103 | R/W | Index | 4096 | ||
time_stamp | 00FE | Time Stamp | Relative time value on network | R | Time | 2050 |
polling_address | 00A2 | Poll addr | Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) | R/W | Unsigned | 128 |
message | 00A4 | Message | Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. | R/W | PackedAscii | 2048 |
descriptor | 00A5 | Descriptor | Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. | R/W | PackedAscii | 2048 |
date | 00A6 | Date | Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. | R/W | HartDate | 2048 |
final_assembly_number | 00A9 | Final asmbly num | Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device. | R/W | Unsigned | 2048 |
device_specific_status_0 | 102B | Status group 0 | Field Device Specific Status Byte 1- Data that has Field Device status information relating to: failures / warnings / status of process's. | R | BitEnum | 2051 |
device_specific_status_1 | 102C | Status group 1 | Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's. | R | BitEnum | 2051 |
device_specific_status_2 | 102D | Status group 2 | Field Device Specific Status Byte 3- Data that has Field Device status information relating to: failures / warnings / status of process's. | R | BitEnum | 2051 |
Name | ID | Label | Description | Type | Access | Class |