Name ID Label Description Type Access Class
analog_output_saturated1 0FC8 AO saturated Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. R BitEnum 67
analog_output_saturated2 0FC9 AO saturated Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. R BitEnum 67
analog_output_saturated3 0FCA AO saturated Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. R BitEnum 67
analog_output_fixed1 0FCB AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 67
analog_output_fixed2 0FCC AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 67
analog_output_fixed3 0FCD AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 67
xmtr_specific_status_6 0FBB Status group 15 Field Device Specific Status Byte 15- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
xmtr_specific_status_7 0FBC Status group 16 Field Device Specific Status Byte 16- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
xmtr_specific_status_8 0FBD Status group 17 Field Device Specific Status Byte 17- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
xmtr_specific_status_9 0FBE Status group 18 Field Device Specific Status Byte 18- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
Name ID Label Description Type Access Class