Name ID Label Description Type Access Class
pulse_width_1 406F Pls Width R/W Enum 512
pulse_mode_1 4070 Active mode R/W Enum 2048
pulse_alarm_1 4071 At alarm R/W Enum 2048
pulse_out_2 4072 Pulse/Freq 2 R/W Float 512
freq_out_2 4073 Pulse/Freq 2 R/W Float 514
pulse_width_2 4074 Pls Width R/W Enum 512
pulse_mode_2 4075 Active mode R/W Enum 2048
pulse_alarm_2 4076 At alarm R/W Enum 2048
pulse1_function 4077 Pulse/Stat 1 sel R/W Enum 1024
pulse2_function 4078 Pulse/Stat 2 sel R/W Enum 1024
pulse_rate_1 4079 Pulse 1 rate R/W Float 32
pulse_rate_2 407A Pulse 2 rate R/W Float 32
pulse_units_1 407B Pulse 1 unit R/W Enum 32
pulse_units_2 407C Pulse 2 unit R/W Enum 32
input_level 407D SI active mode Select trigger level for binary input R/W Enum 1024
input_function 407E Input function Select the function of binary input R/W Enum 1024
status1_mode 407F SO 1 active mode R/W Enum 2050
status1_function 4080 SO 1 function R/W Enum 1024
status2_mode 4081 SO 2 active mode R/W Enum 2050
status2_function 4082 SO 2 function R/W Enum 1024
analog_units 4083 Unidade analógica R/W Enum 64
analog_value_1 4084 Analog 1 out R/W Float 66
analog_value_2 4085 Analog 2 out R/W Float 66
percent_range_1 4086 % range 1 out Porcentagem da faixa – Variável que segue a representação do valor digital em relação à faixa definida pelo valor da faixa inferior e valor da faixa superior, para modos de operação normal. As unidades dessa variável são sempre em porcentagem. R Float 34
percent_range_2 4087 % range 2 out Porcentagem da faixa – Variável que segue a representação do valor digital em relação à faixa definida pelo valor da faixa inferior e valor da faixa superior, para modos de operação normal. As unidades dessa variável são sempre em porcentagem. R Float 34
analog_LoLimit_1 4088 Analog 1 low LMT R/W Float 1024
analog_LoLimit_2 4089 Analog 2 low LMT R/W Float 1024
analog_HiLimit_1 408A Analog 1 high LMT R/W Float 1024
analog_HiLimit_2 408B Analog 2 high LMT R/W Float 1024
serial_number 408E Sensor S/N Número de série do sensor – Unicamente indentifica o sensor do qual a representação de valor digital ou variável do dispositivo de campo é primariamente derivada. R/W Unsigned 2048
rota_transfer_function 408F Função Xfer R/W Enum 32
flow_direction 4090 Flow direction R/W Enum 2048
temp_fix_select 4091 Temp fix val sel R/W Enum 2048
temp_fixed_value 4092 Temp fixed value R/W Float 8
temp_gain_adjust 4093 Temp gain adjust R/W Float 2048
temp_offset_adjust 42EA Temp offset adjust Adjust offset of temperature measurement R/W Float 2048
fluid_max_temp_value 4094 Fluid max temp R Float 32
dens_fix_select 4095 Dens fix val sel R/W Enum 2048
dens_fixed_value 4096 Reference dens value R/W Float 8
dens_ref_value 4294 Dens ref value R/W Float 8
mass_flow_fix_select 4097 Mass flo fix sel R/W Enum 2048
mass_flow_fixed_value 4098 Mass flo fixed val R/W Float 8
heat_of_combustion_value 4295 Heat of combustion Heat of combustion value R/W Float 8
heat_of_combustion_units 4296 Heat of combu unit Heat of combustion unit R/W Enum 32
release_date 4297 Device S/W date Device S/W date R HartDate 2048
release_revision 4298 Device S/W version Device S/W version R PackedAscii 2048
burn_out_state 4299 Burn out Burn out State of the Electronic Transmitter R Enum 2048
key_status 4099 Key status R/W Enum 2048
rcct_long_tag 409A Long Tag Long Tag- Text that is associated with the Field Device installation. R/W ASCII 2048
alarm_select_1 409B Alarm 1 select R/W Enum 1024