Name ID Label Description Type Access Class
flow_var_digital_value 4006 Flow value Primary Variable R Float 10
flow_var_digital_units 4007 Flow units select Primary Variable- Digital representation that tracks the Analog Output(if it exists) Number 1, under normal operating modes R/W Enum 8
flow_var_digital_format 4008 Flow format R/W Enum 2048
flow_var_digital_trunc 400A Flow trunc R/W Enum 10
flow_var_sensor_format 400D Sensor format R/W Enum 2048
flow_var_sensor_trunc 4018 Range format R/W Enum 2048
flow_var_digital_damping 4012 Flow damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 32
flow_var_upper_sensor_limit 400F PV USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 32
flow_var_upper_sensor_scale_limit 412F Scale USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 32
flow_var_lower_sensor_limit 4010 PV LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 32