Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
usl_value | 400C | USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 32 |
lsl_value | 400D | LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 32 |
dummy_float | 400E | dummy float | R | Float | 32 | |
dummy_3integer_value | 400F | dummy_3integer_value | R | Unsigned | 2048 | |
dummy_alarm_select | 4010 | AO Alrm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
dummy_transfer_func | 4011 | dummy_transfer_func | R | Enum | 2048 | |
pv_value_a | 4002 | PV | The conductivity value that changes magnitude with respect to time with no user intervention. | R | Float | 34 |
sv_value_a | 4004 | SV | The conductivity value that changes magnitude with respect to time with no user intervention. | R | Float | 34 |
pv_uncomp_a | 4006 | Uncomp. | Conductivity value without temperature compensation. | R | Float | 34 |
pv_value | 4001 | PV | The conductivity value that changes magnitude with respect to time with no user intervention. | R | Float | 34 |
sv_value | 4003 | SV | The conductivity value that changes magnitude with respect to time with no user intervention. | R | Float | 34 |
temp_value | 4013 | Temp | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R/W | Float | 34 |
temp_ref | 4017 | Ref.Temp. | Reference temperature used for temp. compensation | R/W | Float | 34 |
ma_output | 400A | AO1 | Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes | R/W | Float | 66 |
ma_perc | 400B | PV % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 66 |
tc1_perc | 4019 | TC1 perc | Temperature compensation percentage 1 | R/W | Float | 2050 |
tc2_perc | 401A | TC2 perc | Temperature compensation percentage 2 | R/W | Float | 2050 |
perc_conc | 401B | Conc. % | Concentration percentage | R | Float | 2050 |
if_value | 401D | CC | Cell constant | R/W | Float | 2050 |
sensor_offset | 401E | Sens.off. | Sensor offset (value measured during AIRCAL) | R/W | Float | 2050 |
lower_range_val | 401F | LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 64 |
upper_range_val | 4020 | URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 64 |
ma_fixed | 4021 | Hold fix | mA-output value when Hold-Fixed selected | R/W | Float | 64 |
sc_err5_hs | 4024 | Err.5 | Error message configuration. Soft fail will give a flashing FAIL flag. Hard fail will give a steady FAIL flag and, when enabled an updated mA-output value | R/W | Enum | 1024 |
sc_err6_hs | 4025 | Err.6 | Error message configuration. Soft fail will give a flashing FAIL flag. Hard fail will give a steady FAIL flag and, when enabled an updated mA-output value | R/W | Enum | 1024 |
sc_err7_hs | 4026 | Err.7 | Error message configuration. Soft fail will give a flashing FAIL flag. Hard fail will give a steady FAIL flag and, when enabled an updated mA-output value | R/W | Enum | 1024 |
sc_err8_hs | 4027 | Err.8 | Error message configuration. Soft fail will give a flashing FAIL flag. Hard fail will give a steady FAIL flag and, when enabled an updated mA-output value | R/W | Enum | 1024 |
table_0 | 4028 | 0% | mA-output table 0% value (4.0 mA) | R/W | Float | 64 |
table_5 | 4029 | 5% | mA-output table 5% value (4.8 mA) | R/W | Float | 64 |
table_10 | 402A | 10% | mA-output table 10% value (5.6 mA) | R/W | Float | 64 |
table_15 | 402B | 15% | mA-output table 15% value (6.4 mA) | R/W | Float | 64 |
table_20 | 402C | 20% | mA-output table 20% value (7.2 mA) | R/W | Float | 64 |
table_25 | 402D | 25% | mA-output table 25% value (8.0 mA) | R/W | Float | 64 |
table_30 | 402E | 30% | mA-output table 30% value (8.8 mA) | R/W | Float | 64 |
table_35 | 402F | 35% | mA-output table 35% value (9.6 mA) | R/W | Float | 64 |
table_40 | 4030 | 40% | mA-output table 40% value (10.4 mA) | R/W | Float | 64 |
table_45 | 4031 | 45% | mA-output table 45% value (11.2 mA) | R/W | Float | 64 |
table_50 | 4032 | 50% | mA-output table 50% value (12.0 mA) | R/W | Float | 64 |
table_55 | 4033 | 55% | mA-output table 55% value (12.8 mA) | R/W | Float | 64 |
table_60 | 4034 | 60% | mA-output table 60% value (13.6 mA) | R/W | Float | 64 |
table_65 | 4035 | 65% | mA-output table 65% value (14.4 mA) | R/W | Float | 64 |
table_70 | 4036 | 70% | mA-output table 70% value (15.2 mA) | R/W | Float | 64 |
table_75 | 4037 | 75% | mA-output table 75% value (16.0 mA) | R/W | Float | 64 |
table_80 | 4038 | 80% | mA-output table 80% value (16.8 mA) | R/W | Float | 64 |
table_85 | 4039 | 85% | mA-output table 85% value (17.6 mA) | R/W | Float | 64 |
table_90 | 403A | 90% | mA-output table 90% value (18.4 mA) | R/W | Float | 64 |
table_95 | 403B | 95% | mA-output table 95% value (19.2 mA) | R/W | Float | 64 |
table_100 | 403C | 100% | mA-output table 100% value (20.0 mA) | R/W | Float | 64 |
matrix_t1 | 403D | Matrix T1 | Matrix 1st temperature | R/W | Float | 2050 |
matrix_t2 | 403F | Matrix T2 | Matrix 2nd temperature | R/W | Float | 2050 |