Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
device_specific_status_23_latched_value | 128D | Latched Device Specific Status 23 | W | BitEnum | 2049 | |
device_specific_status_24_latched_value | 128E | Latched Device Specific Status 24 | W | BitEnum | 2049 | |
config_change_counter_latched_value | 128F | Latched Cfg chng count | W | Unsigned | 2048 | |
pressure_units | 138D | Pres Unit | Unità variabile dispositivo di campo - Unità ingegneristica da visualizzare con la rappresentazione del valore digitale, intervallo minimo, valore di campo superiore, valore di campo inferiore, limite sensore inferiore e limite sensore superiore. Pressione - Pressione del processo misurata rispetto a una pressione di riferimento | R/W | Enum | 8 |
pressure_value | 138E | Pres | Valore variabile dispositivo di campo - Valore digitale che cambia magnitudine rispetto al tempo senza l’intervento dell’utente. Pressione - Pressione del processo misurata rispetto a una pressione di riferimento. | R | Float | 10 |
pressure_percent_range | 138F | Pres % | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 34 |
pressure_upper_range_limit | 1393 | Pres USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_lower_range_limit | 1394 | Pres LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_minimum_span | 1390 | Pres Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_output_transfer_function | 1391 | Pres xfer fnctn | Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 32 |
Name | ID | Label | Description | Type | Access | Class |