Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
flow_calc_mode | 4081 | Flow Calc Mode | Flow Calculation Mode | R/W | Enum | 2048 |
fluid_type | 40B1 | Fluid Type | Fluid Type Code | R/W | Enum | 2048 |
flow_calc_fixed | 40B2 | Flow Calc Fixed | Flow Calc Fixed Variable | R/W | Float | 2048 |
ref_sp | 4055 | Ref SP | Reference Static Press | R/W | Float | 2048 |
ref_temp | 4066 | Ref Temp | Reference Temperature | R/W | Float | 2048 |
temp_k1 | 40B3 | Temp K1 | Temp K1 For Liquid Variable | R/W | Float | 2048 |
joker_passwd_log | 40B4 | Software seal | Software Seal Code | R | Enum | 2048 |
pres_for_trim | 400F | Pres for trim | Pressure Value or % Value for Trim | R | Float | 10 |
sp_for_trim | 4050 | SP for trim | Static Pressure Value or % Value for Trim | R | Float | 10 |
pres_alert_mode | 4004 | Pres Alert mode | Pressure HI/LO Alarm Mode | R/W | Enum | 2048 |
pres_hi_alert_val | 4006 | Pres Hi Alert Val | Pressure High Alarm Setpoint | R/W | Float | 2048 |
pres_lo_alert_val | 4008 | Pres Lo Alert Val | Pressure Low Alarm Setpoint | R/W | Float | 2048 |
sp_urv | 404C | SP URV | Static Pressure Upper Range Value | R/W | Float | 32 |
sp_lrv | 404B | SP LRV | Static Pressure Lower Range Value | R/W | Float | 32 |
sp_damp | 4083 | SP Damp | Static Pressure Damping Value | R/W | Float | 8 |
sp_alert_mode | 4085 | SP Alert Mode | Static Pressure HI/LO Alarm Mode | R/W | Enum | 2048 |
sp_hi_alert_val | 404E | SP Hi Alert Val | Static Pressure High Alarm Setpoint | R/W | Float | 2048 |
sp_lo_alert_val | 404F | SP Lo Alert Val | Static Pressure Low Alarm Setpoint | R/W | Float | 2048 |
et_units | 4057 | ET Unit | Field Device Variable Unit- Digital unit that the variable will be displayed with. Sensor Temperature- Temperature associated with the sensor that is responsible for a process measurement. | R/W | Enum | 8 |
et_lrv | 405C | ET LRV | External Temperature Lower Range Value | R/W | Float | 32 |
et_urv | 405D | ET URV | External Temperature Upper Range Value | R/W | Float | 32 |
et_damp | 4087 | ET Damp | External Temperature Damping Value | R/W | Float | 8 |
et_alert_mode | 4089 | ET Alert Mode | External Temperature HI/LO Alarm Mode | R/W | Enum | 2048 |
et_hi_alert_val | 4060 | ET Hi Alert Val | External Temperature High Alarm Setpoint | R/W | Float | 2048 |
et_lo_alert_val | 4061 | ET Lo Alert Val | External Temperature Low Alarm Setpoint | R/W | Float | 2048 |
Name | ID | Label | Description | Type | Access | Class |