Loading…
Name ID Label Description Type Access Class
pres_hi_alert_val 4006 Pres Hi Alert Val Pressure High Alarm Setpoint R/W Float 2048
pres_lo_alert_val 4008 Pres Lo Alert Val Pressure Low Alarm Setpoint R/W Float 2048
sp_urv 404C SP URV Static Pressure Upper Range Value R/W Float 32
sp_lrv 404B SP LRV Static Pressure Lower Range Value R/W Float 32
sp_damp 4083 SP Damp Static Pressure Damping Value R/W Float 8
sp_alert_mode 4085 SP Alert Mode Static Pressure HI/LO Alarm Mode R/W Enum 2048
sp_hi_alert_val 404E SP Hi Alert Val Static Pressure High Alarm Setpoint R/W Float 2048
sp_lo_alert_val 404F SP Lo Alert Val Static Pressure Low Alarm Setpoint R/W Float 2048
et_units 4057 ET Unit Field Device Variable Unit- Digital unit that the variable will be displayed with. Sensor Temperature- Temperature associated with the sensor that is responsible for a process measurement. R/W Enum 8
et_lrv 405C ET LRV External Temperature Lower Range Value R/W Float 32