Loading…
Name ID Label Description Type Access Class
sp_hi_alert_val 4072 SP Hi Alert Val Sets threshold value for static pressure high alarm. R/W Float 2048
sp_lo_alert_val 4073 SP Lo Alert Val Sets threshold value for static pressure low alarm. R/W Float 2048
temp_hi_alert_val 4074 Temp Hi Alert Val Sets threshold value for sensor temperature high alarm. R/W Float 8
temp_lo_alert_val 4075 Temp Lo Alert Val Sets threshold value for sensor temperature low alarm. R/W Float 8
do_select 4076 DO Select DO selection- Select alarm(s) whose status should be output via digital output. R/W Enum 1024
do_signal_type 4077 DO Signal type DO signal type- Defines the action of digital output when the alarm is detected. R/W Enum 1024
disp_out_1 4029 Disp Out1 LCD output1- Defines the variable to be shown on LCD. R/W Enum 256
disp_out_2 402A Disp Out2 LCD output2- Defines the variable to be shown on LCD. R/W Enum 256
disp_out_3 402B Disp Out3 LCD output3- Defines the variable to be shown on LCD. R/W Enum 256
disp_out_4 402C Disp Out4 LCD output4- Defines the variable to be shown on LCD. R/W Enum 256
Name ID Label Description Type Access Class