Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
squawk_control | 0988 | Squawk Control | W | Enum | 2048 | |
xmtr_chk_abort_flag | 415E | R/W | Unsigned | 4096 | ||
static_pressure_value | 4002 | SP | Static Pressure- Pressure of the process measured with respect to the reference pressure equal to 0. | R | Float | 10 |
static_pres_percent | 4003 | SP % | Static pressure percent of range- Static Pressure Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
snsr_temp_value | 4004 | センサー温度 | Sensor temperature- Temperature measured at sensor capsule. | R | Float | 10 |
easy_engr_unit | 40B4 | Engineer Unit Select Code for Easy Setting | R/W | Enum | 256 | |
engr_disp_value | 4005 | Engr Disp | Engineering display- Process variable displayed in user scale and unit. | R | Float | 258 |
engr_exp | 4006 | Engr exp | Engineering display exponents- Exponents for user scale display. | R/W | Enum | 256 |
engr_disp_unit | 4007 | Engr Unit | Engineering unit- Engineering unit for user scale display. | R/W | ASCII | 256 |
p_lower_trim_dev | 4039 | P LTD | Lower pressure trim deviation- Deviation from the original value. | R | Float | 8 |
p_upper_trim_dev | 403A | P UTD | Upper pressure trim deviation- Deviation from the original value. | R | Float | 8 |
sp_lower_trim_point | 403D | SP LTP | Lower static pressure trim point- Applied static pressure at which the last lower static pressure trim was performed. | R | Float | 8 |
sp_upper_trim_point | 403E | SP UTP | Upper static pressure trim point- Applied static pressure at which the last upper static pressure trim was performed. | R | Float | 8 |
sp_lower_trim_dev | 4040 | SP LTD | Lower static pressure trim deviation- Deviation from the original value. | R | Float | 8 |
sp_upper_trim_dev | 4041 | SP UTD | Upper static pressure trim deviation- Deviation from the original value. | R | Float | 8 |
trim_who | 4043 | Trim Who | Trim information- Text that is associated with the trim information. This text can be used by the user in any way. A recommended use is to record who to trim the device. | R/W | PackedAscii | 2048 |
trim_date | 4044 | Trim Date | Trim information- Text that is associated with the trim information. This text can be used by the user in any way. A recommended use is to record when the latest trim is done for the device. | R/W | HartDate | 2048 |
trim_loc | 4045 | Trim Loc | Trim information- Text that is associated with the trim information. This text can be used by the user in any way. A recommended use is to record where the latest trim is done for the device. | R/W | PackedAscii | 2048 |
trim_desc | 4046 | Trim Desc | Trim information- Text that is associated with the trim information. This text can be used by the user in any way, and there is no recommended use. | R/W | PackedAscii | 2048 |
low_cut_point | 4011 | Low cut | Low cut- Sets the range in vicinity of 0% within which the low cut function is activated according to the selected low cut mode. | R/W | Float | 2048 |
low_cut_mode | 4012 | Low cut mode | Low cut mode- Selects the type of the low cut function to be used; LINEAR or ZERO. | R/W | Enum | 2048 |
hl_swap | 4013 | H/L Swap | High/Low swap- Reverses the high pressure side and low pressure side of the transmitter. For example, use this function when assigning the high pressure impulse line connection to the L side of the transmitter. | R/W | Enum | 2048 |
sp_lrv | 4050 | SP LRV | Static Pressure Lower Range Value- Defines the operational endpoint from which the 0% point of the Percent Range are derived. | R/W | Float | 32 |
sp_urv | 4051 | SP URV | Static Pressure Upper Range Value- Defines the operational endpoint from which the 100% point of the Percent Range are derived. | R/W | Float | 32 |
static_pressure_units | 404A | SP Unit | Static Pressure Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit for the Static Pressure. | R/W | Enum | 8 |