Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
device_specific_status_17_latched_value | 1287 | Status group 10 | W | BitEnum | 2049 | |
device_specific_status_18_latched_value | 1288 | Latched Device Specific Status 18 | W | BitEnum | 2049 | |
device_specific_status_19_latched_value | 1289 | Latched Device Specific Status 19 | W | BitEnum | 2049 | |
device_specific_status_20_latched_value | 128A | Latched Device Specific Status 20 | W | BitEnum | 2049 | |
device_specific_status_21_latched_value | 128B | Latched Device Specific Status 21 | W | BitEnum | 2049 | |
device_specific_status_22_latched_value | 128C | Latched Device Specific Status 22 | W | BitEnum | 2049 | |
device_specific_status_23_latched_value | 128D | Latched Device Specific Status 23 | W | BitEnum | 2049 | |
device_specific_status_24_latched_value | 128E | Latched Device Specific Status 24 | W | BitEnum | 2049 | |
pressure_units | 138D | Unit | Unidad de variable de dispositivo de campo: Unidad de medición que se mostrará con la representación del valor digital, span mínimo, valor de rango superior, valor de rango inferior, límite inferior del sensor y límite superior del sensor. Presión: Presión del proceso medida con respecto a una presión de referencia | R/W | Enum | 8 |
pressure_value | 138E | Pres | Valor de variable de dispositivo de campo: Valor digital que cambia de magnitud con respecto al tiempo sin intervención del usuario. Presión: Presión del proceso medida con respecto a una presión de referencia. | R | Float | 10 |
pressure_percent_range | 138F | Pres % | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 34 |
pressure_damping_value | 1398 | Pres Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 32 |
pressure_lower_range_value | 1397 | LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 32 |
pressure_upper_range_value | 1396 | URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 32 |
pressure_lower_range_limit | 1394 | LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_upper_range_limit | 1393 | USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_minimum_span | 1390 | Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_output_transfer_function | 1391 | Xfer fnctn | Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 32 |
module_fill_fluid | 139E | Fill fluid | Sensor Fill Fluid- Fluid material in the module | R/W | Enum | 2048 |
flange_type | 139A | Process Conn type | Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor | R/W | Enum | 2048 |
number_of_remote_seals | 139F | Num of RS | Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed | R/W | Enum | 2048 |
remote_seal_type | 139D | RS type | Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. | R/W | Enum | 2048 |
analog_output_value | 1779 | AO | Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes. Analog Output- Measurable physical output which changes with respect to time, without user intervention. | R/W | Float | 66 |
analog_output_alarm_select | 177A | AO alm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. Analog Output- Measurable physical output which changes with respect to time, without user intervention. | R | Enum | 1026 |
module_type_code | 177B | Module type | Measurement Type- Type of measurement application this Field Device is intended to be used with | R/W | Enum | 2048 |
sensor_a_lower_sensor_trim_point | 1774 | P LTP | Lower Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. | R | Float | 8 |
sensor_a_upper_sensor_trim_point | 1776 | P UTP | Upper Sensor Trim Point- Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. | R | Float | 8 |
flange_material | 177C | Process Conn matl | Flange Material- Construction material of flange type | R/W | Enum | 2048 |
remote_seal_isolator_material | 177E | RS isoltr matl | Remote Seal Isolator Material- Construction material of a part of the remote seal type that comes in contact with the process material. This is only unambiguous if 1 remote seal is installed. | R/W | Enum | 2048 |
module_isolator_material | 177F | Isoltr matl | Sensor Isolator Material- Construction material of a part of the module type that comes in contact with the process material | R/W | Enum | 2048 |
drain_vent_material | 1780 | Drain vent matl | Drain Vent Material- Construction material of a removable plug that exists on the flange type that can be opened temporarily to remove unwanted process from the sensor area | R/W | Enum | 2048 |
pressure_sensor_serial_number | 1770 | Pres snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. | R | Unsigned | 2048 |
Name | ID | Label | Description | Type | Access | Class |