Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
device_specific_status_24_latched_value | 128E | Latched Device Specific Status 24 | W | BitEnum | 2049 | |
pressure_units | 138D | Unit | Unidad de variable de dispositivo de campo: Unidad de medición que se mostrará con la representación del valor digital, span mínimo, valor de rango superior, valor de rango inferior, límite inferior del sensor y límite superior del sensor. Presión: Presión del proceso medida con respecto a una presión de referencia | R/W | Enum | 8 |
pressure_value | 138E | Pres | Valor de variable de dispositivo de campo: Valor digital que cambia de magnitud con respecto al tiempo sin intervención del usuario. Presión: Presión del proceso medida con respecto a una presión de referencia. | R | Float | 10 |
pressure_damping_value | 1398 | Pres Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 32 |
pressure_lower_range_limit | 1394 | LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_upper_range_limit | 1393 | USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_minimum_span | 1390 | Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
module_fill_fluid | 139E | Fill fluid | Sensor Fill Fluid- Fluid material in the module | R/W | Enum | 2048 |
flange_type | 139A | Process Conn type | Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor | R/W | Enum | 2048 |
number_of_remote_seals | 139F | Num of RS | Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed | R/W | Enum | 2048 |
Name | ID | Label | Description | Type | Access | Class |