Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
xmtr_specific_status_3 | 0FB8 | Status group 4 | Field Device Specific Status Byte 4- Data that has Field Device status information relating to: failures / warnings / status of process's. | R | BitEnum | 2051 |
xmtr_specific_status_4 | 0FB9 | Status group 5 | Field Device Specific Status Byte 5- Data that has Field Device status information relating to: failures / warnings / status of process's. | R | BitEnum | 2051 |
xmtr_specific_status_5 | 0FBA | Status group 6 | Field Device Specific Status Byte 6- Data that has Field Device status information relating to: failures / warnings / status of process's. | R | BitEnum | 2051 |
xmtr_specific_status_6 | 0FBB | Status group 7 | Field Device Specific Status Byte 7- Data that has Field Device status information relating to: failures / warnings / status of process's | R | BitEnum | 2051 |
xmtr_specific_status_7 | 0FBC | Status group 8 | Field Device Specific Status Byte 8- Data that has Field Device status information relating to: failures / warnings / status of process's | R | BitEnum | 2051 |
xmtr_specific_status_8 | 0FBD | Status group 9 | Field Device Specific Status Byte 9- Data that has Field Device status information relating to: failures / warnings / status of process's | R | BitEnum | 2051 |
burst_mode_select | 0FFF | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | W | Enum | 128 |
burst_command_number | 0FFD | Burst option | Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. | W | Enum | 128 |
pressure_units | 138D | Unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure | R/W | Enum | 8 |
pressure_value | 138E | Pres | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
Name | ID | Label | Description | Type | Access | Class |