Loading…
Name ID Label Description Type Access Class
descriptor 00A5 Descriptor Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. R/W PackedAscii 2048
date 00A6 Fecha Fecha: Fecha del calendario gregoriano almacenada en el dispositivo de campo. El usuario puede usar esta fecha de cualquier manera. No hay ningún uso específico recomendado. R/W HartDate 2048
write_protect 00A7 Write protect Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. R Enum 2050
private_label_distributor 00A8 Distribuidor Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers R Enum 2048
final_assembly_number 00A9 Final asmbly num Número de ensamblaje final: Número que se utiliza con fines de identificación y está asociado al dispositivo de campo en general. R/W Unsigned 2048
analog_output_saturated3 0FCA AO saturated Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. R BitEnum 67
analog_output_fixed3 0FCD AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 67
xmtr_specific_status_0 0FB5 Status group 1 Estado específico del dispositivo de campo Byte 1: Datos que tiene el estado del dispositivo de campo información relativa a: fallos/advertencias/estado de los procesos. R BitEnum 2051
xmtr_specific_status_1 0FB6 Status group 2 Estado específico del dispositivo de campo Byte 2: Datos que tiene el estado del dispositivo de campo información relativa a: fallos/advertencias/estado de los procesos. R BitEnum 2051
xmtr_specific_status_2 0FB7 Status group 3 Estado específico del dispositivo de campo Byte 3: Datos que tiene el estado del dispositivo de campo información relativa a: fallos/advertencias/estado de los procesos. R BitEnum 2051
Name ID Label Description Type Access Class