Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
physical_signaling_code | 00AB | Physicl signl code | Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port | R | Enum | 2048 |
device_flags | 00A0 | Dev flags | Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer | R | BitEnum | 128 |
device_id | 00A1 | Dev id | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. | R | Unsigned | 128 |
polling_address | 00A2 | Poll addr | Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) | W | Unsigned | 128 |
tag | 00A3 | Tag | Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. | R/W | PackedAscii | 2048 |
message | 00A4 | Message | Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. | R/W | PackedAscii | 2048 |
descriptor | 00A5 | Descriptor | Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. | R/W | PackedAscii | 2048 |
date | 00A6 | Date | Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. | R/W | HartDate | 2048 |
write_protect | 00A7 | Write protect | Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. | R | Enum | 2048 |
private_label_distributor | 00A8 | Distributor | Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers | R | Enum | 2048 |
final_assembly_number | 00A9 | Final asmbly num | Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device. | R/W | Unsigned | 2048 |
xmtr_specific_status_0 | 0FB5 | Status group 1 | Field Device Specific Status Byte 1- Data that has Field Device status information relating to: failures / warnings / status of process's. | R | BitEnum | 2051 |
xmtr_specific_status_1 | 0FB6 | Status group 2 | Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's. | R | BitEnum | 2051 |
burst_command_number | 0FFD | Burst option | Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. | W | Enum | 128 |
burst_mode_select | 0FFF | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | W | Enum | 128 |
pressure_units | 138D | Unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 8 |
pressure_value | 138E | Pres | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pressure_percent_range | 138F | % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 34 |
pressure_upper_range_limit | 1393 | USL | Upper Sensor Limit Value- Defines the maximum useable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_lower_range_limit | 1394 | LSL | Lower Sensor Limit Value- Defines the minimum useable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_minimum_span | 1390 | Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_output_transfer_function | 1391 | Transfer function | Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 32 |
pressure_upper_range_value | 1396 | URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 32 |
pressure_lower_range_value | 1397 | LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 32 |
pressure_damping_value | 1398 | Damping | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 8 |
flange_type | 139A | Flange type | Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 2048 |
o_ring_material | 139B | O ring matl | O Ring Material- Construction material of a seal that exists between the module and flange. | R/W | Enum | 2048 |
meter_installation | 139C | Meter type | Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. | R/W | Enum | 256 |
remote_seal_type | 139D | RS type | Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. | R/W | Enum | 2048 |
module_fill_fluid | 139E | Fill fluid | Sensor Fill Fluid- Fluid material in the module. | R/W | Enum | 2048 |
number_of_remote_seals | 139F | Num remote seal | Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed. | R/W | Enum | 2048 |
analog_output_value | 1779 | AO1 Out | Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes. Analog Output- Measureable physical output which changes with respect to time, without user intervention. | R/W | Float | 66 |
analog_output_alarm_select | 177A | AO1 Alrm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. Analog Output- Measureable physical output which changes with respect to time, without user intervention. | R | Enum | 64 |
pressure_sensor_serial_number | 1770 | Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. | R | Unsigned | 2048 |
module_type_code | 177B | Meas typ | Measurement Type- Type of measurement application this Field Device is intended to be used with. | R | Enum | 2048 |
sensor_a_lower_sensor_trim_point | 1774 | Lo snsr trim pt | Lower Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. | R/W | Float | 8 |
sensor_a_upper_sensor_trim_point | 1776 | Up snsr trim pt | Upper Sensor Trim Point- Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. | R/W | Float | 8 |
flange_material | 177C | Flange matl | Flange Material- Construction material of flange type. | R/W | Enum | 2048 |
remote_seal_isolator_material | 177E | RS isoltr matl | Remote Seal Isolator Material- Construction material of a part of the remote seal type that comes in contact with the process material. This is only unambiguous if 1 remote seal is installed. | R/W | Enum | 2048 |
module_isolator_material | 177F | Isoltr matl | Sensor Isolator Material- Construction material of a part of the module type that comes in contact with the process material. | R/W | Enum | 2048 |
local_keys_mode_control_codes | 1781 | Local keys | Local Keys Control Mode- Controls the mode of the User Interface keys on the Field Device. | R/W | Enum | 256 |
drain_vent_material | 1780 | Drain vent matl | Drain Vent Material- Construction material of a removable plug that exists on the flange type that can be opened temporarily to remove unwanted process from the sensor area. | R/W | Enum | 2048 |
dummy_menu_entry | 1B6D | Not Applicable | R | Enum | 0 | |
Name | ID | Label | Description | Type | Access | Class |