名称 ID 标签 描述 类型 访问 分类
pressure_minimum_span 1390 最小范围 Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. 浮点 8
pressure_output_transfer_function 1391 传送功能 Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. Pressure- Pressure of the process measured with respect to a reference pressure. 读/写 枚举 32
pressure_upper_range_value 1396 URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. 读/写 浮点 32
pressure_lower_range_value 1397 LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. 读/写 浮点 32
pressure_damping_value 1398 阻尼 Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. 读/写 浮点 8
flange_type 139A 法兰类型 Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. 读/写 枚举 2048
o_ring_material 139B O形环材料 O Ring Material- Construction material of a seal that exists between the module and flange. 读/写 枚举 2048
meter_installation 139C 仪表类型 Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. 读/写 枚举 256
remote_seal_type 139D RS类型 Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. 读/写 枚举 2048
module_fill_fluid 139E 填充液 Sensor Fill Fluid- Fluid material in the module. 读/写 枚举 2048
名称 ID 标签 描述 类型 访问 分类