device_specific_status_20_mask 1279 Device Specific Status 20 Mask R/W BitEnum 2049
device_specific_status_0_latched_value 127E Latched Device Specific Status 0 W BitEnum 2049
device_specific_status_1_latched_value 127F Latched Device Specific Status 1 W BitEnum 2049
device_specific_status_2_latched_value 1280 Latched Device Specific Status 2 W BitEnum 2049
device_specific_status_3_latched_value 1281 Latched Device Specific Status 3 W BitEnum 2049
device_specific_status_4_latched_value 1282 Latched Device Specific Status 4 W BitEnum 2049
device_specific_status_5_latched_value 1283 Latched Device Specific Status 5 W BitEnum 2049
device_specific_status_14_latched_value 1284 Latched Device Specific Status 14 W BitEnum 2049
device_specific_status_15_latched_value 1285 Latched Device Specific Status 15 W BitEnum 2049
device_specific_status_16_latched_value 1286 Latched Device Specific Status 16 W BitEnum 2049
device_specific_status_17_latched_value 1287 Latched Device Specific Status 17 W BitEnum 2049
device_specific_status_18_latched_value 1288 Latched Device Specific Status 18 W BitEnum 2049
device_specific_status_19_latched_value 1289 Latched Device Specific Status 19 W BitEnum 2049
device_specific_status_20_latched_value 128A Latched Device Specific Status 20 W BitEnum 2049
config_change_counter_latched_value 128F Latched Cfg chng count W Unsigned 2048
update_period 12BE Update Period Update period for burst message R/W Time 2048
max_update_period 12BF Max Update Period Maxium update period for burst message R/W Time 2048
burst_command_number 0FFD Burst Command Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. R/W Enum 128
trigger_level 1268 Burst Trigger Level R/W Float 2048
eventNumber 129B Event Number R/W Index 4096
last_clock_time 115B Set Clock Time Time to set the real time clock in the field device to, or time that the real-time clock was last set R/W Time 2048
last_clock_date 115A Set Clock Date Date to set the real-time clock in the field device to, or date that the real-time clock was last set R/W HartDate 2048
current_time 1159 Current Time Current Time based upon the real-time clock in the field device R Time 2050
current_date 1158 Current Date Current Date based upon the real-time clock in the field device R HartDate 2050
burst_message_number 12E7 Burst Message Number R/W Index 4096
totalizer2_digital_unit 4044 Total 2 digital unit R/W Enum 0
totalizer3_digital_unit 4052 Total 3 digital unit R/W Enum 0
compat_burst_mode_0 4063 Burst mode Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. R/W Enum 2048
compat_burst_vars_0_0 4064 slot0 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_1_0 4065 slot1 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_2_0 4066 slot2 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_3_0 4067 slot3 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_4_0 4068 slot4 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_5_0 4069 slot5 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_6_0 406A slot6 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_7_0 406B slot7 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_cmd_1 406D Burst Command Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. R/W Enum 2048
compat_burst_mode_1 406E Burst mode Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. R/W Enum 2048
compat_update_per_1 406F Update Period Update period for burst message R/W Time 2048
compat_max_update_per_1 4070 Max Update Period Maxium update period for burst message R/W Time 2048
compat_burst_vars_0_1 4071 slot0 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_1_1 4072 slot1 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_2_1 4073 slot2 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_3_1 4074 slot3 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_4_1 4075 slot4 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_5_1 4076 slot5 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_6_1 4077 slot6 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_vars_7_1 4078 slot7 Burst Variable Slot 1- Device variable code assigned to slot 1 to be read in burst mode. R/W Enum 2048
compat_burst_trig_mode_1 4079 Burst Msg Trigger Mode R/W Enum 2048
compat_burst_trig_class_1 407A Burst Trigger Class R/W Enum 2048